2KMD40S - Rectron

2KMD40S
SCHOTTKY BARRIER BRIDGE RECTIFIER
VOLTAGE 40 Volts CURRENT 2.0 Ampere
FEATURES
Low switching noise
Low forward voltage drop
High current capability
High switching capability
High surge capabitity
High reliability
M D-S
MECHANICAL DATA
1
2
3
4
.035(0.9)
.020(0.5)
.108(2.74)
.092(2.34)
.106(2.7)
.091(2.3)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
o
Ratings at 25 C ambient temperature unless otherwise specified.
.193(4.9)
.177(4.5)
.152(3.6)
.260(6.6)
.004(0.10) MAX.
.275(7.0)
Case: Molded plastic
Epoxy: Device has UL flammability classification 94V-O
Lead: MIL-STD-202E method 208C guaranteed
Mounting position: Any
Weight: 0.1 34 gram
M D
*
*
*
*
*
.157(4.0)
*
*
*
*
*
*
.014(0.35)
.006(0.15)
Dimensions in inches and (millimeters)
MAXIMUM RAT INGS (@ TA=25 OC unless otherwise noted)
SYMBOL
2KMD40S
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
40
Volts
Maximum RMS Voltage
VRMS
28
Volts
VDC
40
Volts
IO
2.0
Amps
I FSM
60
Amps
Typical Thermal Resistance (Note 1)
R ΘJ A
R ΘJ L
50
Typical Junction Capacitance (Note 3)
CJ
110
pF
Operating Te mperature Ran g e
TJ
150
0
C
T STG
-55 to + 150
0
C
R ATINGS
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at Derating Lead Te mperature
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Storage Temperature Ran g e
15
0
C/W
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 2.0 A DC
Maximum Average Reverse Current
@T A = 25 o C
at Rated DC Blocking Voltage
@T A = 100 o C
SYMBOL
2KMD40S
UNITS
VF
0.5
Volts
50
uA
IR
NOTES : 1 . Thermal Resistance : At 9.5mm lead lengths, PCB mounted.
2. Measured at 1 MHz and applied reverse voltage of 4.0 volts.
3. "Fully ROHS compliant", "100% Sn plating (Pb-free)".
2
mA
2012-02
REV:O
MINSTANTANEOUS REVERSE CURRENT, (mA)
RATING AND CHARACTERISTICS CURVES ( 2KMD40S )
AVERAGE FORWARD CURRENT, (A)
2.5
2.0
1.5
1.0
Single Phase Half Wave
60Hz Inductive or
Resistive Load
0.5
0
0
50
100
10
O
1.0 TA = 100 C
TA = 75 OC
0.1
TA = 25 OC
0.01
0.001
150
0
O
LEAD TEMPERATURE, ( C)
20
80
100
120
140
FIG.2 TYPICAL REVERSE
CHARACTERISTICS
50
CJ, JUNCTION CAPACITANCE, (pF)
400
10
1.0
TJ = 25 OC
Pulse width=300µS
1% Duty Cycle
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
TJ = 25 OC
200
100
80
60
40
20
10
0.1
0.4
INSTANTANEOUS FORWARD VOLTAGE, (V)
1.0
4
8.3mS Single Half Sine-Wave
JEDEC Method
50
40
30
20
10
1
40
FIG.4 TYPICAL JUNCTION CAPACITANCE
60
0
10
REVERSE VOLTAGE, (V)
FIG.3 TYPICAL INSTANTANEOUS FORWARD
CHARACTERISTICS
PEAK FORWARD SURGE CURRENT, (A)
INSTANTANEOUS FORWARD CURRENT, (A)
60
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
0.1
40
2
5
10
20
50
100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
80100
Marking Description
Rectron Logo
UL Logo
Year – code
(Y:Last digit of year &
A:2010,B:2011… )
2K40
Part No.
VYWW
Voltage-code
Week – code
(WW:01~52)
2-------40V
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.