MD1S THRU MD7S

MD1S
THRU
MD7S
SINGLE-PHASE GLASS PASSIVATED
SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 0.5 Ampere
FEATURES
*
*
*
*
*
*
*
Surge overload rating - 30 amperes peak
Ideal for printed circuit board
Reliable low cost construction utilizing molded
Glass passivated device
Polarity symbols molded on body
Mounting position: Any
Weight: 0.5 gram
MD-S
MECHANICAL DATA
* Epoxy: Device has UL flammability classification 94V-O
* UL listed under the recognized component directory, file #E94233.
1
2
3
4
M D
0.028(0.9)
.004(0.10) MAX.
0.020(0.5)
0.106(2.7)
0.091(2.3)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
0.152(3.6)
0.157(4.0)
0.014(0.35)
0.006(0.15)
0.193(4.9)
0.177(4.5)
For capacitive load, derate current by 20%.
0.145(3.6)
0.193(4.9)
0.177(4.5)
0.260(6.6)
0.092(2.34)
0.157(4.0)
2.756(7.0)
0.108(2.74)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (At T A = 25oC unless otherwise noted)
SYMBOL
MD1S
MD2S
MD3S
MD4S
MD5S
MD6S
MD7S
UNITS
Maximum Recurrent Peak Reverse Voltage
RATINGS
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS Bridge Input Voltage
VRMS
35
70
140
280
420
560
700
Volts
Maximum DC Blocking Voltage
VDC
50
100
200
400
600
800
1000
Maximum Average Forward Output Current at T A = 40 oC
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Thermal Resistance (Note 2)
Operating and Storage Temperature Range
Volts
IO
0.5
Amps
I FSM
30
Amps
R qJA
85
RqJL
20
T J, T STG
-55 to + 150
0
C/W
0
C
o
ELECTRICAL CHARACTERISTICS (At TA = 25 C unless otherwise noted)
CHARACTERISTICS
SYMBOL
Maximum Forward Voltage Drop per Bridge
VF
Element at 0.5A DC
o
Maximum Reverse Current at Rated
@T A = 25 C
DC Blocking Voltage per element
@T A = 125 o C
Note: 1.”Fully ROHS compliant”,”100% Sn plating(Pb-free).
2. Thermal Resistance: PCB mounted.
IR
MD1S
MD2S
MD3S
MD4S
1.05
MD5S
MD6S
MD7S
UNITS
Volts
5.0
mAmps
0.5
mAmps
2007-08
60
8.3mS Single Half Sine-Wave
JEDEC Method
50
40
30
20
10
0
0
2
4
6
10
20
40
60
100
INSTANTANEOUS FORWARD CURRENT, (A)
PEAK FORWARD SURGE CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( MD1S THRU MD7S )
10
1
0.1
0.01
T J = 25 OC
Pulse Width = 300mS
1% Duty Cycle
0
100
FIG. 1 - MAXIMUM NON-REPETITIVE
FORWARD SURGE CURRENT
1.5
TA = 25 OC
10
1.0
0.1
0
20
40
60
80
100
0.5
1.0
1.5
2.0
2.5
INSTANTANEOUS FORWARD VOLTAGE, (V)
AVERAGE FORWARD CURRENT, (A)
INSTANTANEOUS REVERSE CURRENT, (uA)
NUMBER OF CYCLES AT 60Hz
120
140
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
FIG.3 TYPICAL REVERSE CHARACTERISTICS
FIG.2 TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
1.0
0.5
60 Hz RESISTIVE OR
INDUCTIVE LOAD
0
20
40
60
80
100
120
140 150
AMBIENT TEMPERATURE, (OC)
FIG.4 TYPICAL FORWARD CURRENT
DERATING CURVE
Mounting Pad Layout
.276 Max.
(7.0 Max.)
.105 (2.67)
.095 (2.41)
.035 Min.
(0.90 Min.)
Dimensions in inches and (millimeters)
.030 Min.
(0.76 Min.)
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.