SMC700

SMC700
TECHNICAL DATA
Visible LED, SMD
AlGaAs
SMC700 is a AlGaAs LED mounted on a ceramic SMD package and sealed with silicone or epoxy resin for
damp proof. On forward bias, it emits a radiation of typical 3 mW at a peak wavelength of 700 nm.
Specifications
•
•
•
•
Structure: AlGaAs
Peak Wavelength: typ. 700 nm
Optical Output Power: typ. 3 mW
Package: Ceramic SMD, silicone / epoxy resin
Absolute Maximum Ratings (Ta=25°C)
Item
Symbol
Value
Power Dissipation
PD
110
Forward Current
IF
50
Pulse Forward Current**
IFP
200
Reverse Voltage
VR
5
Operating Temperature
Topr
-20 … +80
Storage Temperature
Tstg
-30 … +80
Soldering Temperature *
Tsol
240
Unit
mW
mA
mA
V
°C
°C
°C
(Unit: mm)
* must be completed within 5 seconds
** max duty cycle 1%, max puls width 10µs
Electro-Optical Characteristics
Item
Forward Voltage
Reverse Current
Total Radiated Power*
Radiation Intensity
Peak Wavelength
Half Width
Viewing Half Angle
Rise Time
Fall Time
Symbol
VF
IR
PO
IE
λP
Δλ
Θ1/2
tR
tF
Condition
IF = 20 mA
VR = 5 V
IF = 20 mA
IF = 20 mA
IF = 20 mA
IF = 20 mA
IF = 20 mA
IF = 20 mA
IF = 20 mA
Min.
1.5
1.0
-
Typ.
1.90
3.0
2.0
700
20
±55
80
80
Max.
2.30
10
-
Unit
V
µA
mW
mW/sr
nm
nm
deg.
ns
ns
* Total Radiated Power is measured by Photodyne #500
Notes
• Do not view directly into the emitting area of the LED during operation!
• The above specifications are for reference purpose only and subjected to change without prior notice.
14.11.2013
SMC700
1 of 2
Soldering Conditions
•
•
•
DO NOT apply any stress to the lead particularly when heat.
After soldering the LEDs should be protected from mechanical shock or vibration until the LEDs
return to room temperature.
When it is necessary to clamp the LEDs to prevent soldering failure, it is important to minimize the
mechanical stress on the LEDs.
Temperature Profile
PCB Footprint Layout
(Unit: mm)
Static Electricity
•
LEDs are very sensitive to Static Electricity and surge voltage. It is recommended to always wear
a wrist band or an anti-electrostatic glove when handling the LEDs.
•
All devices, equipment and machinery must be grounded properly. It is recommended that
precautions should be taken against surge voltage to the equipment that mounts the LEDs.
14.11.2013
SMC700