Data Sheets - Skyworks Solutions, Inc.

DATA SHEET
AAT4631/4631-1
High Power Adjustable Current Limited Load Switch with Fault Flag
General Description
Features
The AAT4631/AAT4631-1 SmartSwitch are high power
current limited P-channel MOSFET power switches
designed for high side load switching applications. The
switches operate with inputs ranging from 2.4V to 5.5V,
making them ideal for both 3V and 5V systems. An integrated current-limiting circuit protects the input supply
against large currents which may cause the supply to fall
out of regulation. Reverse current blocking is provided to
protect the load switch from reverse current potentials
while the device is shutdown.
•
•
•
•
The AAT4631/AAT4631-1 are also protected from thermal overload which is limited by power dissipation and
junction temperatures.
Current limit threshold of AAT4631 is programmed from
500mA to 3.1A with a resistor from SET to ground. The
current limit threshold can also be removed to allow up
to 3A continuous and 4A peak current to flow through the
load switch by shorting the SET pin to ground (This function is the same as AAT4631). The ultra-fast current limit
response to a sudden short circuit is a mere 1μs which
reduces the requirements of local supply bypassing.
An open drain fault flag (FLT) in AAT4631/AAT4631-1
signals an over-current or over-temperature condition
after a 5ms blanking time to prevent false reporting.
Quiescent current is a low 10μA and the supply current
decreases to less than 1μA in shutdown mode.
•
•
•
•
•
•
•
•
•
•
•
3A Continuous, 4A Peak Current Capability
Reverse Blocking During Disable
Input Voltage Range: 2.4V to 5.5V
Programmable Over-Current Threshold: 500mA to
3.1A (AAT4631-1 only)
Fast Transient Response:
▪ 1μs Response to Short Circuit (AAT4631-1 only)
Low Quiescent Current
▪ 10μA Typical while Enabled
▪ 1μA Max with Switch Off (TA = 25°C)
90mΩ Typical RDS(ON)
Under-Voltage Lockout
5ms Fault Blanking
Fault Flag Open Drain Output
Active Hi Enable
Over-Temperature Protection
1.5ms Soft Start
10 Pin TDFN2222-10 Package
Temperature Range: -40°C to +85°C
Applications
•
•
•
•
•
Hot Swap Supplies
Notebook Computers
Portable Products
Proprietary Peripheral Ports
USB Ports
The AAT4631/AAT4631-1 are offered in the small
Pb-free, 10-pin TDFN2222-10 package, and are specified
for operation over the -40°C to +85°C ambient temperature range.
Typical Application
Power Supply Input
Output
IN
Power Supply Input
Output
IN
OUT
AAT4631
1μF
EN
EN
0.47μF
100kΩ
GND
FLT
1μF
EN
EN
OUT
AAT4631-1
0.47μF
100kΩ
SET
GND
FLT
Fault Flag
Fault Flag
RSET
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201949B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • June 4, 2012
1
DATA SHEET
AAT4631/4631-1
High Power Adjustable Current Limited Load Switch with Fault Flag
Pin Description
Pin #
AAT4631
AAT4631-1
Symbol
1
1
FLT
2
2
EN
3
SET
4, 5
4, 5
IN
6, 7
6, 7
OUT
8, 9,
3,10
EP
8, 9,
10
EP
NC
GND
Description
Current limit fault flag pin, open-drain output, active low signal. Pull up with a
10kΩ to 100kΩ resistor.
Load switch enable input. Active high signal.
Current limit set pin. Connect a resistor between this pin and ground to program
the desired current limit set point. Short to ground if no current limit setting is
required. SET pin must not be left floating.
Load switch power supply input pin (high side P-channel MOSFET source). Bypass
with a 1μF capacitor from IN to GND.
Current limiting load switch output (high side P-channel MOSFET Drain). Connect
a 0.47μF capacitor from OUT to GND for best load transient response.
No Connection
IC ground connection. Need to connect to GND.
Exposed paddle. Connect to PCB GND plane.
Pin Configuration
TDFN2222-10
(Top View)
FLT
EN
GND
IN
IN
1
10
2
9
3
EP
7
5
6
AAT4631
2
8
4
GND
NC
NC
OUT
OUT
FLT
EN
SET
IN
IN
1
10
2
9
3
EP
8
4
7
5
6
GND
NC
NC
OUT
OUT
AAT4631-1
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201949B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • June 4, 2012
DATA SHEET
AAT4631/4631-1
High Power Adjustable Current Limited Load Switch with Fault Flag
Absolute Maximum Ratings1
Symbol
Description
VIN
VEN,VFLT
VOUT, VSET
IMAX_DC
IMAX_PULSE
VESD
TJ
TLEAD
IN to GND
EN, FLT to GND
OUT, SET to GND
Maximum DC Output Current2
Maximum Pulse Output Current*
ESD Rating, HBM
Maximum Junction Operating temperature
Maximum Soldering Temperature (at leads, 10 sec)
Value
-0.3 to 6
-0.3 to VIN + 0.3
-0.3 to VIN + 0.3
3.5
4
4
-40 to +150
300
Units
V
A
kV
°C
Thermal Information
Symbol
PD
θJA
Description
Maximum Power Dissipation2,3
Maximum Thermal Resistance3
Value
Units
1381
72.43
mW
°C/W
* Pulse duration must be less than 300μs and period longer than 4ms.
1. Stresses above those listed in Absolute Maximum Ratings may cause permanent damage to the device. Functional operation at conditions other than the operating conditions
specified is not implied.
2. Mounted on FR4 circuit board.
3. Derate 13.8mW/°C above 40°C ambient temperature
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201949B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • June 4, 2012
3
DATA SHEET
AAT4631/4631-1
High Power Adjustable Current Limited Load Switch with Fault Flag
Electrical Characteristics
VIN = 5V; TA = -40°C to 85°C unless otherwise noted. Typical values are at TA = 25°C.
Symbol
Description
Conditions
Input Voltage Range
Operation Quiescent Current
Off Supply Current
Off Switch Current
Reverse Blocking Current
Under-Voltage Lockout
Under-Voltage Lockout Hysteresis
VIN = 5V, EN = Active, IOUT = 0
EN = Inactive, VIN = 5.5V. No load
EN = Inactive, VIN = 5.5V, VOUT = 0V
VIN = 3.7V, VOUT = 4.2V, EN = Inactive
Rising edge
RDS(ON)
On-Resistance
VIN = 5.0V, TA = 25°C
VIN = 3.0V, TA = 25°C
TCRDS
IO
ILIM
VEN(L)
On-Resistance Temperature Coefficient
Maximum Continuous Output Current
Current Limit (only for AAT4631-1)
EN Input Low Voltage
VEN(H)
EN Input High Voltage
VIN
IQ
IQ(OFF)
ISD(OFF)
IREVERSE
VUVLO
VUVLO_HYS
IEN(SINK)
tRESP
tD(ON)
tON
tOFF
TSD
tBLANK
VFLT(LO)
IFLT(SINK)
Input Leakage Current
Current Limit Response Time
Output Turn On Delay Time
Turn On Rising Time
Turn Off Time
Over-Temperature Shutdown Threshold
Fault Flag Blanking Time
Fault Flag Logic Low Output
Fault Flag Logic High Leakage Current
Min
Typ
2.4
RSET = 0Ω1
RSET = 1.1kΩ, VOUT = VIN - 0.5V
VIN = 2.7V to 5.5V
VIN = 2.7V to <4.2V
VIN ≥ 4.2V to 5.5V
VEN = 5.5V
VIN = 5V
VIN = 5V, RSET = 0Ω1, RO = 10Ω
VIN = 5V, RSET = 0Ω1, RO = 10Ω
VIN = 5V, RO = 10Ω
TJ Increasing
VIN = 5V, ILOAD > 0.5A
TJ Decreasing
10
0.01
0.01
2.25
1.8
0.1
75
90
2800
3
3
Max
Units
5.5
25
1
1
2
2.4
V
μA
120
150
mΩ
ppm/°C
3.75
0.6
0.01
1
3
1.5
55
140
115
5
IFLT(SINK) = 1mA
0.5
1
100
μs
°C
0.4
1
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201949B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • June 4, 2012
μA
μs
ms
1. RSET = 0 is only for AAT4631-1.
4
A
V
2.0
2.4
1
V
ms
V
μA
DATA SHEET
AAT4631/4631-1
High Power Adjustable Current Limited Load Switch with Fault Flag
Typical Characteristics
20
15
10
5
0
-40
-15
10
35
60
85
Operation Quiescent Current vs Input Voltage
Operation Quiescent Currnet (μA)
Operation Quiescent Currnet (μA)
Operation Quiescent Current vs Temperature
20
16
12
8
4
0
0
1
2
Temperature (°C)
4
5
6
Input Voltage (V)
Output Current vs Output Voltage
RDS(ON) vs Temperature
(RSET = 1.1kΩ) (AAT4631-1 Only)
(ILOAD = 1.0A)
4
110
3.5
100
3
RDS(ON) (mΩ)
Normalized Current Limit (A)
3
2.5
2
1.5
1
90
80
3V
4V
5V
70
0.5
60
0
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
-40
-15
10
Input Voltage (V)
35
60
85
Temperature (°C)
EN Threshold vs Input Voltage
RSET vs ILIMIT
(AAT4361-1 - Only)
Enable Threshold Voltage (V)
8.8
7.8
RSET (Ω)
6.8
5.8
4.8
3.8
2.8
1.8
0.8
0
0.5
1
1.5
2
ILIMIT (A)
2.5
3
3.5
4
2.4
2.2
2
1.8
1.6
1.4
1.2
1
0.8
VEN_HI
0.6
VEN_LO
0.4
2
2.5
3
3.5
4
4.5
5
5.5
Input Voltage (V)
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201949B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • June 4, 2012
5
DATA SHEET
AAT4631/4631-1
High Power Adjustable Current Limited Load Switch with Fault Flag
Typical Characteristics
Turn - On
Turn-Off
(VIN = 5V; RL = 10Ω; CL = 0.47μF)
(VIN = 5V; RL = 10Ω; CL = 0.47μF)
VOUT
2V/div
VOUT
2V/div
0
EN
2V/div
EN
2V/div
0
Time (800μs/div)
Time (800μs/div)
Short Circuit Through 0.3Ω
Thermal Shutdown Response
(RSET = 3.74kΩ)(AAT4631-1 - Only)
(RL = 10Ω, CL = 0.47μF)
VOUT
2V/div
VOUT
2V/div
0
VIN
2V/div
0
IOUT
4A/div
0
0
IOUT
2A/div
Time (2μs/div)
0
Time (500ms/div)
Fault Delay from Short Circuit
(RSET = 3.74kΩ)(AAT4631-1 - Only)
VOUT
5V/div
IOUT
1A/div
FLT
5V/div
Time (1ms/div)
6
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201949B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • June 4, 2012
DATA SHEET
AAT4631/4631-1
High Power Adjustable Current Limited Load Switch with Fault Flag
Functional Block Diagram
Reverse
Blocking
●
IN
●
●
●
OUT
Over-Temp.
Protection
UnderVoltage
Lockout
FLT
EN
Soft Start
Control
4ms Delay
●
1.2V
Reference
Current
Limit
Control
●
SET
Only for AAT4631-1
Only for AAT4631
GND
Functional Description
The AAT4631/AAT4631-1 are single channel load switches. The devices provide a reverse current blocking feature, ON/OFF enable control, soft start, and a fault flag
to notify a system controller of over-current, short-circuit or over-temperature events.
The programmable current limit function in AAT4631-1 is
intended to protect against short-circuit and over-current events by current limiting to a preset level.
In the event of a load current exceeding a user programmed current limit level (ILIM), a high speed current
limit loop limits the current in a microsecond and will
reset to low impedance once the short-circuit condition
is removed.
To eliminate startup inrush current, a soft-start block
prevents the VOUT from reaching the input voltage level
by more than 1ms to limit the inrush current occuring at
the input. The AAT4631/AAT4631-1 are internally protected from thermal damage by an over-temperature
detection circuit. If the die temperature reaches the
internal thermal limit, the power device is switched off
until the die temperature cools down to a level below the
thermal limit threshold. The devices may operate in a
thermal cycling state indefinitely or until the over-current condition is removed.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201949B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • June 4, 2012
7
DATA SHEET
AAT4631/4631-1
High Power Adjustable Current Limited Load Switch with Fault Flag
Application Information
RSET · ILIM = 3.3 -
Setting the Current Limit (AAT4631-1
only)
Normalized Current Limit (A)
In most applications, the variation in ILIM must be taken
into account when determining RSET. The ILIM variation is
due to processing variations from part to part, as well as
variations in the voltages at IN and OUT, plus the operating temperature. Together, these three factors add up to
a ±25% tolerance (see ILIM specification in "Electrical
Characteristics" section). Figure 1 illustrates a cold
device with a statistically higher current limit and a hot
device with a statistically lower current limit, both with
RSET equal to 1.1kΩ. While the chart, "RSET vs. ILIM" indicates an ILIM of 3A with an RSET of 1.1kΩ, this figure
shows that the actual current limit will be at least 2.25A
and no greater than 3.75A.
Output Current vs Output Voltage
(RSET = 1.1kΩ)
4
3.5
3
2.5
2
1.5
1
-40°C
85°C
0.5
0
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
Output Voltage (V)
Figure 1: Current Limit at High and Low
Temperature Using 1.1kΩ.
To determine RSET, start with the application required current limit as the minimum current limit value and multiply
it by 1.33 to derive the typical current limit value.
Next, refer to Table 1 to find the approximate RSET value.
For greater precision, use the small current limit range
linear approximation to calculate RSET value. For example,
for 2.3A current limit requirement, first calculate the
typical current limit: 2.3A · 1.33 = 3.059A. Then using
table 1, the nearest small current limit range is 3A to 3.1A
with 0.1A current limit interval and -0.045kV RSET · ILIM
coefficient interval. Then adopt the method of linear
approximation in small range to calculate the RSET · ILIM
coefficient.
8
(-0.045) · (3.059 - 3)
= 3.327 (kV)
0.1
RSET =
3.327kV
= 1.087 (kΩ)
3.059A
Referring to the standard resistor table, we can select
1.1kΩ ±1% metal film resistor.
Standard RSET
(kΩ)
ILIM Typ.
(A)
RSET · ILIM
Coefficient (kV)
7.68
6.34
5.49
4.75
4.22
3.74
3.4
3.09
2.8
2.55
2.37
2.21
2.05
1.96
1.82
1.74
1.62
1.54
1.47
1.4
1.33
1.28
1.21
1.18
1.13
1.1
1.05
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
3
3.1
3.840
3.804
3.843
3.800
3.798
3.740
3.740
3.708
3.640
3.570
3.555
3.536
3.485
3.528
3.458
3.480
3.402
3.388
3.381
3.360
3.325
3.328
3.267
3.304
3.277
3.300
3.255
Table 1: Current Limit Standard RSET Value.
Input Capacitor
The input capacitor CIN protects the power supply from
current transients generated by the load attached to the
AAT4631/AAT4631-1. When a short circuit is suddenly
applied to the output of the AAT4631/AAT4631-1, a large
current limited only by the RDS(ON) of the MOSFET, will
flow for less than 1μs before the current limit circuitry
activates. In this event, a moderately sized CIN will dramatically reduce the voltage transient seen by the power
supply and by other circuitry upstream from the
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201949B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • June 4, 2012
DATA SHEET
AAT4631/4631-1
High Power Adjustable Current Limited Load Switch with Fault Flag
AAT4631/AAT4631-1. The extremely fast short-circuit
response time of the AAT4631/AAT4631-1 reduces the
size requirement for CIN.
CIN should be located as close to the device IN pin as
practically possible. Ceramic, tantalum, or aluminum
electrolytic capacitors are appropriate for CIN. There is
no specific capacitor ESR requirement for CIN. However,
for higher current operation, ceramic capacitors are recommended for CIN due to their inherent capability over
tantalum capacitors to withstand input current surges
from low impedance sources such as batteries in portable devices.
Output Capacitor
In order to insure stability while current limit is active, a
low capacitance (approximately 0.47μF) is required. No
matter how large the output capacitor, output current is
limited to the value set by the AAT4631/AAT4631-1 current limiting circuitry, so very large output capacitors
can be used. For example, USB ports are specified to
have at least 120μF of capacitance downstream from
their controlling power switch. The current limiting circuit will allow an output capacitance of 1000μF or more
without disturbing the upstream power supply.
Enable Function
In many systems, power planes are controlled by integrated circuits which run at lower voltages than the
power planes themselves. The enable input (EN) of the
AAT4631/AAT4631-1 has low and high threshold voltages that accommodate this condition. The threshold
voltages are compatible with 5V TTL and 2.5V to 5V
CMOS systems.Both active high and active low options
are available for all packages.
Connecting to Capacitive Load
When switching the AAT4631/AAT4631-1 onto a capacitive load, the AAT4631/AAT4631-1 will charge the output capacitive load at a rate no greater than the current
limit setting.
FAULT Output
The FAULT Flag (FLT) is provided to alert the system if an
AAT4631/AAT4631-1 load is not receiving sufficient voltage to operate properly. If current limit or over-temperature circuits in any combination are active for more than
approximately 5ms, the FAULT Flag is pulled to ground
through an approximately 100Ω resistor. The filtering of
voltage or current transients of less than 4ms prevents
capacitive loads connected to the AAT4631/AAT4631-1
output from activating the FAULT Flag when they are initially attached. Pull-up resistances of 1kΩ to 100kΩ are
recommended. Since FLT is an open drain terminal, it
may be pulled up to any unrelated voltage less than the
maximum operating voltage of 5.5V, allowing for level
shifting between circuits.
Thermal Considerations
Since the AAT4631/AAT4631-1 have internal current
limit and over-temperature protection, junction temperature is rarely a concern. However, if the application
requires large currents in a hot environment, it is possible that temperature, rather than current limit, will be
the dominant regulating condition. In these applications,
the maximum current available without risk of an overtemperature condition must be calculated. The maximum internal temperature while current limit is not
active can be calculated using Equation 1.
TJ(MAX) = I2MAX · RDS(ON)(MAX) · RθJA + TA(MAX)
where IMAX is the maximum current required by the load.
RDS(ON)(MAX) is the maximum rated RDS(ON) of the AAT4631/
AAT4631-1 at high temperature. RθJA is the thermal
resistance between the AAT4631/AAT4631-1 die and the
board onto which it is mounted. TA(MAX) is the maximum
temperature that the PCB under the AAT4631/AAT46311 would be if the AAT4631/AAT4631-1 were not dissipating power. The following equation can be rearranged to
solve for IMAX.
IMAX =
TSD(MIN) - TA(MAX)
RDS(ON)(MAX) ∙ RθJA
where TSD(MIN) is the minimum temperature required to activate
AAT4631/AAT4631-1's over-temperature protection. With the
typical specification of 140°C, 115°C is a safe minimum value to
use.
For example, if an application is specified to operate in 50°C
environments, the PCB operates at temperatures as high as
85°C. The application is sealed and its PCB is small, causing
RθJA to be approximately 72.43°C/W. Using the following
equation:
IMAX =
115 - 85
= 1.66(A)
0.15 · 72.43
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201949B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • June 4, 2012
9
DATA SHEET
AAT4631/4631-1
High Power Adjustable Current Limited Load Switch with Fault Flag
Evaluation Board
The PCB layout is shown in Figures 3 and 4. The bill of
materials (BOM) for the board is shown in Table 2 and
Table 3.
The evaluation board schematic is shown in Figure 2.
R1
100KΩ
JP1
U1
1
1
2
3
2
RSET
VIN
3
4
C1
1μF
5
FLT
GND
EN
NC
GND/SET* NC
IN
OUT
IN
OUT
10
9
8
7
VOUT
6
AAT4631/AAT4631-1
C2
0.47μF
*GND is only for AAT4631; SET is only for AAT4631-1.
Figure 2: AAT4631/AAT4631-1 Evaluation Board Schematic.
Component
Part Number
Description
C1
C2
R1
RSET
U1
JP1
GRM188R71A474K
GRM188R71C105K
RC0603JR-07100KL
RC0603-070RL
AAT4631IDH-2-T1
CAP CERAMIC 0.47μF 0603 X7R 10V 10%
CAP CERAMIC 1μF 0603 X7R 16V 10%
100K, 1/16W 5% 0603 SMD
0Ω, 1/16W 5% 0603 SMD
Load Switch
Device Enable/Disable Selector
Manufacture
Murata
Yageo
Skyworks
Table2: AAT4631 Evaluation Board Bill of Materials (BOM).
Component
Part Number
Description
Manufacture
U1
C1
C2
R1
RSET
JP1
AAT4631-1IDH-2-T1
GRM188R71A474K
GRM188R71C105K
RC0603JR-07100KL
RC0603FR-071K1L
Load Switch
CAP CERAMIC 0.47μF 0603 X7R 10V 10%
CAP CERAMIC 1μF 0603 X7R 16V 10%
100K, 1/16W 5% 0603 SMD
1.1K, 1/16W 1% 0603 SMD
Device Enable/Disable Selector
Skyworks
Murata
Yageo
Table3: AAT4631-1 Evaluation Board Bill of Materials (BOM).
10
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201949B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • June 4, 2012
DATA SHEET
AAT4631/4631-1
High Power Adjustable Current Limited Load Switch with Fault Flag
Figure 3: AAT4631/AAT4631-1 Evaluation Board PCB Top Side.
Figure 4: AAT4631/AAT4631-1 Evaluation Board PCB Bottom Side.
PCB Layout Guideline
1. To maximize package thermal dissipation and power
handling capacity, solder the exposed paddle of the IC
onto the thermal landing of the PCB, where the thermal
landing is connected to the ground plane. Also, adding
more thermal vias on the thermal landing helps transfer
heat to the PCB effectively.
2. All of the GND pins of IC need to connect to GND.
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201949B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • June 4, 2012
11
DATA SHEET
AAT4631/4631-1
High Power Adjustable Current Limited Load Switch with Fault Flag
Ordering Information
Package
Marking1
Part Number (Tape and Reel)2
TDFN2222-10
TDFN2222-10
X3XYY
W8XYY
AAT4631IDH-T1
AAT4631IDH-1-T1
Skyworks Green™ products are compliant with
all applicable legislation and are halogen-free.
For additional information, refer to Skyworks
Definition of Green™, document number
SQ04-0074.
Package Information
TDFN2222-10
2.200 ± 0.050
Detail "A"
0.400 ± 0.050
0.180 ± 0.050
1.700 ± 0.050
2.200 ± 0.050
Index Area
0.900 ± 0.050
Top View
0.400 BSC
Bottom View
0.500 ± 0.050
0.203 REF
0.750 ± 0.050
Pin 1 Indicator
(optional)
Detail "A"
Side View
All dimensions in millimeters.
1. XYY = assembly and date code.
2. Sample stock is generally held on part numbers listed in BOLD.
Copyright © 2012 Skyworks Solutions, Inc. All Rights Reserved.
Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a
service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no
responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes.
No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale.
THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR
PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES
NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM
THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper
use or sale.
Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product
design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters.
Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for
identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference.
12
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com
201949B • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • June 4, 2012