SM-25-96 Discontinued Datasheet

25W
SWITCHING POWER SUPPLY MODULES
•
•
•
•
•
•
•
•
•
Single, Dual and Triple Output Models
85-265 VAC Universal Input Voltage Range
Pin-Mount and Chassis-Mount Packages
CE Mark: UL/CSA/EN60950 Approvals
FCC Class A Input Line Filter
0% Minimum Load Requirement
Over-Current/Short-Circuit Protection
2-Year Warranty
Minimum 165,000-Hour MTBF
CHARACTERISTICS
AC Input ....................................Universal input voltage range 85-265
VAC single phase or 118-370 VDC.
Input Line Frequency ................47-440 Hz.
Input Line Protection .................Input line fuse provided. (Note 1.)
EMI Filter...................................Standard. Meets conducted EMI
requirements of FCC Class A.
DC Output .................................See table.
Continuous Output Power.........25W, maximum (see Note 10).
Output Voltage Adjust ...............Chassis-mount models only: Primary
output adjustable ±3%; auxiliary outputs fixed. Dual output models: outputs adjustable ±3% (V1 and V2
move together). See Note 10.
Efficiency...................................60%,minimum (115 or 230 VAC
input, full load conditions).
Hold-Up Time ............................16 ms (115 VAC input), 32 ms (230
VAC input), minimum, nominal load.
Overload Protection ..................Power-limit circuit.
Short-Circuit Protection.............Continuous.
Over-Voltage Protection............Primary output (V1), 120% of rated
output voltage, typical. For dual output models with ±12V or ±15V outputs, 120% of 2V1 or -2V2.
Soft Start ...................................Standard on all models. Prevents
output overshoot and power transformer saturation at turn-on.
Design Topology .......................Flyback converter with current-mode
control.
Frequency of Operation ............65 kHz (fixed).
Hi-Pot Isolation..........................5300 VDC, input-to-output for one
minute.
Noise, Ripple and Spike ...........1% peak-to-peak, max. (Note 3.)
Power-Fail Warning...................Optional—chassis-mount, single output, 5V model only: TTL-compatible
(logic 1, 4 ms, minimum, before loss
of output). To specify the power-fail
option, add the letter “P” to the
model number suffix.
Temperature Range ..................-20°C to +70°C.
Output Power De-Rating...........De-rate output power and current
linearly 2%/°C from +50°C to +70°C.
Temperature Coefficient ............±0.05%/°C over the entire operating
temperature range.
Relative Humidity ......................0 to 95%, non-condensing.
Altitude ......................................0 to 10,000 feet.
Cooling ......................................Convection cooling is adequate.
When operating in a confined area,
moving air is recommended.
Storage Temperature ................-40°C to +85°C.
Storage Humidity ......................0 to 95%, non-condensing.
Mean Time Between Failures ...>165,000 hours. (Note 4.)
06
Model
Output Current Output
Output Voltage Min. Nom. Max. Voltage Line Load CrossOutput (V)
(A) (A)
(A)
Tol. Reg. Reg. Reg.
AC-DC Singles
SM1-25-1DCM
SM1-25-2DCM
SM1-25-3DCM
SM1-25-4DCM
SM1-25-5DCM
SM1-25-6DCM
V1
V1
V1
V1
V1
V1
Chassis-Mount: 85-265 VAC Input
5
9
12
15
24
28
0.00
0.00
0.00
0.00
0.00
0.00
5.00
2.80
2.10
1.70
1.05
0.90
5
9
12
15
24
28
0.00
0.00
0.00
0.00
0.00
0.00
5.00
2.80
2.10
1.70
1.05
0.90
+5
-5
+12
- 12
+15
- 15
0.00
0.00
0.00
0.00
0.00
0.00
4.00
1.00
1.00
1.00
0.80
0.80
+5
-5
+12
- 12
+15
- 15
0.00
0.00
0.00
0.00
0.00
0.00
4.00
1.00
1.00
1.00
0.80
0.80
+5
+12
- 12
+5
+15
- 15
0.00
0.00
0.00
0.00
0.00
0.00
4.00
0.20
0.20
3.80
0.20
0.20
+5
+12
- 12
+5
+15
- 15
0.00
0.00
0.00
0.00
0.00
0.00
4.00
0.20
0.20
3.80
0.20
0.20
AC-DC Singles
SM1-25-1DPM
SM1-25-2DPM
SM1-25-3DPM
SM1-25-4DPM
SM1-25-5DPM
SM1-25-6DPM
V1
V1
V1
V1
V1
V1
SM2-25-2DCM
SM2-25-3DCM
V1
V2
V1
V2
V1
V2
SM2-25-2DPM
SM2-25-3DPM
V1
V2
V1
V2
V1
V2
SM3-25-1DCM
SM3-25-2DCM
SM3-25-1DPM
SM3-25-2DPM
—
—
—
—
—
—
5.00
2.80
2.10
1.70
1.05
0.90
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
0.1%
0.1%
0.1%
0.1%
0.1%
0.1%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
—
—
—
—
—
—
4.00
1.60
1.80
1.80
1.60
1.60
1.0%
4.0%
2.0%
2.0%
2.0%
2.0%
0.1%
0.1%
0.5%
0.5%
0.5%
0.5%
0.5% —
0.3% 0.3%
2.0% —
2.0% 2.0%
2.0% —
2.0% 2.0%
4.00
1.60
1.80
1.80
1.60
1.60
1.0%
4.0%
2.0%
2.0%
2.0%
2.0%
0.1%
0.1%
0.5%
0.5%
0.5%
0.5%
0.5% —
0.3% 0.3%
2.0% —
2.0% 2.0%
2.0% —
2.0% 2.0%
Chassis-Mount: 85-265 VAC Input
AC-DC Triples
V1
V2
V3
V1
V2
V3
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
Pin-Mount: 85-265 VAC Input
AC-DC Triples
V1
V2
V3
V1
V2
V3
0.1%
0.1%
0.1%
0.1%
0.1%
0.1%
Chassis-Mount: 85-265 VAC Input
AC-DC Duals
SM2-25-1DPM
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
Pin-Mount: 85-265 VAC Input
AC-DC Duals
SM2-25-1DCM
5.00
2.80
2.10
1.70
1.05
0.90
4.00
0.30
0.30
4.00
0.30
0.30
1.0%
4.0%
4.0%
1.0%
4.0%
4.0%
0.1%
0.1%
0.1%
0.1%
0.1%
0.1%
0.5%
0.3%
0.3%
0.5%
0.3%
0.3%
—
0.1%
0.1%
—
0.1%
0.1%
Pin-Mount: 85-265 VAC Input
4.00
0.30
0.30
4.00
0.30
0.30
1.0%
4.0%
4.0%
1.0%
4.0%
4.0%
0.1%
0.1%
0.1%
0.1%
0.1%
0.1%
0.5%
0.3%
0.3%
0.5%
0.3%
0.3%
—
0.1%
0.1%
—
0.1%
0.1%
POWER GENERAL 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email [email protected]
25W
SWITCHING POWER SUPPLY MODULES
Pin-Mount Single Output Models
Chassis-Mount Models
Pin-Mount Dual / Triple Output Models
Chassis-Mount Models
Pin
SM1-25
SM2-25
1
AC LIne
AC LIne
2
AC Neutral
AC Neutral
3
-Sense
N/C
4
Return
V1
5
V1
Common
6
+Sense
Common
7
Power Fail
V2
Notes
A. Dimensions shown are in inches.
B. Tolerances = 0.00 ±0.01 inch.
0.000 ±0.005 inch.
C. Terminal “SW” on chassis-mount models is for ac line connection through an external switch: No internal connection.
Pin-Mount Models
Terminal SM1-25
1
AC LIne
2
AC Neutral
3
V1
4
Return
5
N/C
6
N/A
7
N/A
SM2-25
AC LIne
AC Neutral
V2
N/C
Common
N/C
V1
SM3-25
AC LIne
AC Neutral
V3
V1 Return
V2/V3 Common
V1
V2
SM3-25
AC LIne
AC Neutral
V1 Return
V1
V3
V2/V3 Common
V2
1. An external input line fuse is optional: Use a 2A/250V slow-blow fuse.
2. All measurements are made directly at the terminals of the supply.
3. Peak-to-peak and RMS metering equipment must have a 20 MHz frequency response with probes and cables that maintain a frequency
response of 20 Hz to 20 MHz. Output ripple and spikes are measured
directly at the output terminals of the power supply with a 0.1 µF ceramic capacitor. The probe ground band must make contact with the output
return or common terminal to prevent erroneous noise measurements.
4. MTBF is calculated using the parts stress method in MIL-HDBK 217F
(ground benign, TA = +25°C).
5. Output voltage tolerance is measured under nominal load conditions.
6. Line regulation is measured under nominal load conditions as the input
voltage is varied from 85 to 265 VAC.
7. Load regulation is measured at 115 VAC or 230 VAC. The output under
test is brought to 60% of nominal load; load current is then varied ±40%
of nominal while other outputs are held at nominal load conditions.
8. Cross-regulation is tested by changing the load on the primary output
from 50% to 100% of nominal load while measuring the voltage change
on the auxiliary output under test.
9. Remote sensing links are provided for single output, chassis-mount
models for improved load regulation.
10. De-rate output power by 1% for each 1% of remote-sensing compensation or output voltage adjustment.
11. The SM1-25, SM2-25 and SM3-25 series are approved to UL1950 (File
E140439), CSA (File LR52335) and to EN60950/IEC950/DIN VDE 0805
(TÜV License R0097573).
POWER GENERAL 152 Will Drive · Canton, MA 02021 USA · Phone 781-828-6216 · Fax 781-830-1155 · Email [email protected]
7