CINT1175 175W Single Output Industrial Series Features 2” x 4” x 1.3” Package For 1U Applications 175W w/air, 120W convection cooled Universal Input 90-264 VAC Average Efficiency meets Level V Requirements Approved to CSA/EN/IEC/UL60950, 2nd Edition 12V fan output Efficiency 90% typical at Full Load 3 Year Warranty RoHS Compliant Description A highly dense 175Watts AC to DC power supply designed for industrial and ITE applications. With convection rating of 120 Watts, CINT1175 family leads the market in power density and low leakage makes it a perfect solution for lighting applications. With input & output monitoring alarms plus isolated 12V/0.4A fan, it is one the most feature rich supplies and can easily fit in 1U chassis. All 5 models are CE marked to low voltage directive and approved to ITE standards of EN60950, 2nd edition. Model Selection Model Number Volts CINT1175A1206K01 12V 14.6A 10.0A 12Vdc/04.A CINT1175A1506K01 15V 11.7A 8.0A 12Vdc/04.A CINT1175A2406K01 24V 7.3A 5.0A CINT1175A4806K01 48V 3.6A CINT1175A5606K01 56V 3.1A Notes: Output Current w/200LFM air Convection Total Regulation OVP*** Threshold*** ±3% 14.0 ± 1.1V 0.5%RMS, 1.0% pk-pk ±3% 18.5 ± 1.5V 12Vdc/04.A 0.5%RMS, 1.2% pk-pk ±3% 28.0 ± 2.5V 2.5A 12Vdc/04.A 0.5%RMS, 1.0% pk-pk ±3% 55.0 ± 4.0V 2.1A 12Vdc/04.A 0.5%RMS, 1.0% pk-pk ±3% 59.0 ± 1.0V Fan Output Ripple & Noise** 0.5%RMS, 1.2% pk-pk * Total convection power is 120 Watts. ** Measured with noise probe directly across output terminals, and load terminated with 0.1µF ceramic and 10µF low ESR capacitors. *** Output adjustment on 56V model will not exceed 56.2 volts. General Specifications AC Input Input Current Inrush Current www.slpower.com 100-240Vac, ±10%, 47-63Hz, 1∅ 120–370Vdc Turn On Time Less than 2 sec. @115Vac (inversely proportional to input voltage and thermistor temperature) 115Vac: 2A, 230Vac: 1A Hold-up Time 16mS, typical 264Vac, cold start: will not exceed 50A CINT1175 REV 5.4, 6 April-15 Signals AC Power Fail, DC OK 1 CINT1175 175W Single Output Industrial Series General Specifications (continued) Input Fuse Earth Leakage Current Efficiency Output Power Transient Response 4A, 250VAC fuse provided on all models <350µA@264Vac, 60Hz, NC Overload Protection Short Circuit Protection Overvoltage Protection 90% typical at 115Vac 175W continuous, with 200 lfm airflow, 120W convection cooled – See chart for specific voltage model ratings. Switching Frequency 50% load step. ∆i/∆t: <0.2A/µS Max Volt Deviation = 3% Isolation Hiccup Mode Provided - no damage will occur if the output is shorted. OVP firing reduces output voltage to <50% of nominal in <50ms. See chart for trip range. PFC: 65kHz typical Input-Output: 4000Vac Input-Ground: 1800Vac Output-Ground: 1500Vac Ripple and Noise See chart Operating Temperature -10°C to +70°C Start Up at -40°C, full load Output Voltage See chart Temperature Derating Derate output power linearly above 50°C to 50% at 70°C Voltage Adjustability Minimum Load Total Regulation Vibration Dimensions Weight Storage Temperature +/-5% from nominal Altitude Not required Relative Humidity +/- 3%. See chart Operating: 0.003g/Hz, 1.5grms overall, 3 axes, 10 min/axis Non-Operating: 0.026g2/Hz, 5.0grms overall, 3 axes, 1 hr/axis Shock Safety Standards W: 2.0” x L: 4.0” x H: 1.3” MTBF 210g -40°C to +85°C Operating: -500 to 10,000 ft. Non-operating: -500 to 40,000 ft. 5% to 95%, non-condensing Operating: Half-sine, 20gpk, 10ms, 3 axes, 6 shocks total Non-Operating: Half-sine, 40 gpk, 10 ms, 3 axes, 6 shocks total EN/CSA/UL/IEC 60950-1, 2nd Edition 331,105 hours, 175W load, 110Vac input, 25°C ambient Auxiliary Signals AC Power Fail: Inhibit: www.slpower.com During normal operations, stays HIGH. Signal goes LOW with 5mS warning before loss of DC output from AC failure. DC OK: Open collector logic signal goes and stays HIGH 100mS to 500mS after main output reaches regulation. Connect to inhibit pin to output common to inhibit the DC output. CINT1175 REV 5.4, 6 April-15 2 CINT1175 175W Single Output Industrial Series EMI / EMC Compliance Conducted Emissions EN55011/22 Class B, FCC Part 15, Subpart B, Class B Radiated Emissions EN55011/22 Class A, FCC Part 15, Subpart B, Class A w/6db margin Static Discharge Immunity EN61000-4-2, Criteria A, 6kV Contact Discharge, 8kV air discharge Radiated RF Immunity EN61000-4-3, 3V/m. Criteria A EFT/Burst Immunity EN61000-4-4, 2kV/5kHz, Criteria A Line Surge Immunity EN61000-4-5, 1kV differential, 2kV common-mode, Criteria A Conducted RF Immunity EN61000-4-6, 3Vrms, Criteria A Power Frequency Magnetic Field Immunity EN61000-4-8, 3A/m, Criteria A Voltage Dip Immunity EN61000-4-11, 0% Vin, 0.5cycle; 40% Vin, 5 cycles; 70% Vin, 25 cycles; Criteria A Line Harmonic Emissions EN61000-3-2, Class A, B, C, & D Flicker Test EN61000-3-3, Complies (dmax<6%) Mechanical Drawing When installing the power supply into the end-product, a non-conductive Insulator should be placed between the unit and any conductive metal chassis or mounting platform. www.slpower.com CINT1175 REV 5.4, 6 April-15 3 CINT1175 175W Single Output Industrial Series Connector Information Input Connector J100 Ground J101 DC Output Connector J300 Fan Output Connector J500 Signal Connector J600 PIN 1) AC LINE PIN 2) EMPTY PIN 3) AC NEUTRAL .187 x .032 FASTON TAB PIN 1) +Vout PIN 4) -Vout PIN 2) +Vout PIN 5) -Vout PIN 3) +Vout PIN 6) -Vout PIN 1) +12Vfan PIN 2) RTN PIN 1) Inhibit PIN 2) PF/DC OK PIN 3, 4) Common Mating Connector: Molex 09-50-3031 Pins= 08-52-0072 Mating Connector: Molex 01-90020009 Mating Connector: AMP 640250-6 Pins = 640252-1 Mating Connector: Molex 1375820-2 Pins = 1375819 Mating Connector: Molex 1375820-4 Pins = 1375819 Fan Output – J500 J500 provides a [email protected] output to support a system cooling fan. The fan output is always available when AC input is present, so it also can be used for a 12V standby output is so desired. AC Power Failure/DC OK and Inhibit Signals – J600 Timing Sequence www.slpower.com CINT1175 REV 5.4, 6 April-15 4 CINT1175 175W Single Output Industrial Series Isolation Specifications Parameter Conditions/Description Insulation Safety Rating Input/Ground Input/Output Output/Ground Electric Strength Test Voltage Input/Ground Input/Output Output/Ground Min Nom Max Units - - Vac Vac Vac Min Nom Max Units 90 115/230 264 Vac Basic Reinforced n/a 1800 4000 1500 Input Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Parameter Conditions/Description Input Voltage Turn-On Input Voltage Ramping up 82.7 Vac Turn-Off Input Voltage Ramping down 67.0 Vac Input Frequency 47 50/60 63 Hz 264Vac, cold start - - 50 A Power Factor Vi nom, Io nom 0.9 - - Efficiency Vi nom, Io nom CINT1175A1206K01 CINT1175A1506K01 CINT1175A2406K01 CINT1175A4806K01 CINT1175A5606K01 - 90% - % Parameter Conditions/Description Min Nom Max Units Output Voltage Setpoint Accuracy CINT1175A1206K01 Vi nom,, Io1 @ ADC, TC = 25 °C -3 - 3 % Vo nom Output Voltage Setpoint Accuracy CINT1175A1506K01 Vi nom,, Io1 @ ADC, TC = 25 °C -3 - 3 % Vo nom Output Voltage Setpoint Accuracy CINT1175A2406K01 Vi nom,, Io1 @ ADC, TC = 25 °C -3 - 3 % Vo nom Output Voltage Setpoint Accuracy CINT1175A4806K01 Vi nom,, Io1 @ ADC, TC = 25 °C -3 - 3 % Vo nom Output Voltage Setpoint Accuracy CINT1175A5606K01 Vi nom,, Io1 @ ADC, TC = 25 °C -3 - 3 % Vo nom Output Current V1 Output Current V2 CINT1175A1206K01 0 0 10.0 - 14.6 0.4 ADC ADC Output Current V1 Output Current V2 CINT1175A1506K01 0 0 8.0 - 11.7 0.4 ADC ADC Output Current V1 Output Current V2 CINT1175A2406K01 0 0 5.0 - 7.3 0.4 ADC ADC Output Current V1 Output Current V2 CINT1175A4806K01 0 0 2.5 - 3.6 0.4 ADC ADC Output Current V1 Output Current V2 CINT1175A5606K01 0 0 2.1 - 3.1 0.4 ADC ADC Static Line Regulation V1 Vi min-Vi max, Vi nom, 0-100% Io nom -1 - 1 % Vo nom Static Load Regulation V1 (Droop Characteristic) Vi min-Vi max, Vi nom, 0-100% Io nom -3 - 3 % Vo nom Inrush Current Limitation Output Specifications www.slpower.com CINT1175 REV 5.4, 6 April-15 5 CINT1175 175W Single Output Industrial Series Output Specifications (continued) Parameter Conditions/Description Min Nom Max Units Hold-Up Time Starting at Vi = 230 VAC, Po nom - 16 - ms Dynamic Load Regulation Load change =50%, di/dt =0.2A/µS voltage deviation 3% 0 3 % Vo nom Start-Up Time Vi nom, Io nom 0 2 s Max Units 2 KV (CM) - Protection All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted Parameter Conditions/Description Input Fuse Not user accessible Input Transient Protection Output Min Nom 2KV(CM) and 1KV(DM) surge No-load and short circuit proof Hiccup or Latch short circuit proof Hiccup or Latch overload (latch style) Hiccup Overvoltage Protection Latch style Latch Over temperature Protection Automatic power shutdown at TC =155°C Characteristic Curves Output vs. Temperature 120W convection cooled and 175W continuous with 200 LFM airflow, Derating output power to 50% at 70°C. www.slpower.com CINT1175 REV 5.4, 6 April-15 6 CINT1175 175W Single Output Industrial Series Efficiency vs. Loading The high efficiency is achieved by using LLC technology, PFC topology minimizing switching losses. Synchronous SCHOTTKY or ultra-fast diode is used as rectifier in CINT1175 family because of high output voltage level. Noise & Ripple To verify that the output ripple and noise does not exceed the level specified in the product specification. Measured using a scope probe socket with 0.1uF ceramic and a 10uF electrolysis capacitor connected in parallel across it, BW limit with 20MHz. www.slpower.com CINT1175 REV 5.4, 6 April-15 7 CINT1175 175W Single Output Industrial Series Output Transient Response 50% load step within the regulation limits of minimum and maximum load, dI/dt< 0.2A/µSec. Recovery time not specified as there is no laps in regulation with a 50% Load Step. Maximum voltage deviation is 3%, This test is performed on the MAIN OUTPUT ONLY. Output Overload Characteristic Supply shall protect itself against Overload conditions. The Power Supply shall recover from Overload Conditions without operator intervention. Output Overshoot When supply is turned on, off or when the load is stepped 100%, the Power Supply Overshoot/Undershoot shall not exceed minimum or maximum of output voltage regulation. www.slpower.com CINT1175 REV 5.4, 6 April-15 8