MS-332-3 - PIC GmbH

MS-332-3
S W I T C HI N G T HE S M A R T WAY
MS-332-3
Standard Reed Sensor Flatpack
Electrical Characteristics
@ 25 °C
Contact form
Features
A
Contact rating max.
Switching voltage max.
W / VA
10
VDC
200
VAC
140
Switching current max.
A
1
Carry current max.
A
1.2
Breakdown voltage min.
VDC
240
Total resistance max. (initial)
mΩ
200
Ω
10 10
Insulation resistance min.
Magnetical Characteristics (of unmodified Reed Switch)
AT
Pull in range available
AT
5
TC -
014
Customized types available
Approvals
2
Operating Characteristics (of unmodified Reed Switch)
Switching frequency max.
Various sensitivity ranges available
@ 25 °C
Test coil
± AT
Replaces various competitors types
10 - 25
Drop out min.
Test equipment tolerance
Adjustable switching point
@ 25 °C
Hz
500
Resonant frequency typ.
Hz
4000
Operate time max. (incl. bounce)
ms
1
Release time max.
ms
0.4
Operating temperature
°C
-20 to + 85
Vibration (50-2000 Hz)
g
20
Shock (1/2 sin 11 ms)
g
100
Environmental Characteristics
Dimensions in mm
Ordering Information
Packing Unit
50 pcs
Weight per piece
5.8 g
Weight per package
300 g
C
I
P
©
H
b
m
G
Standard AT Ranges
1=
10 to 15 AT
2=
15 to 20 AT
3=
20 to 25 AT
Ordering Example
MS-332-3-2 describes MS-332-3 with 15 to 20 AT.
Page 1 of 2
Rev.:
1.3
ms3323_ds_e_1.3
PIC Proximity Instrumentation Controls
Kontaktbauelemente GmbH
Nibelungenstr. 5 A
90530 Wendelstein, Germany
Phone
Fax
+49 911 99 59 06-0
+49 911 99 59 06-99
[email protected]
www.pic-gmbh.com
MS-332-3
S W I T C HI N G T HE S M A R T WAY
MS-332-3
Standard Reed Sensor Flatpack
Material Information
Material
Colour
Housing
ABS
black
Cable
UL 1007/1569, AWG 24, 4 mm stripped and tinned
black
Potting compound
Epoxy
black
Test Procedure of final Reed Sensor
Test Parameters
Test coil
TC- 324
Test programs
AT range
Test program
1 =
MS-332-3-1
2 =
MS-332-3-2
3 =
MS-332-3-3
Remarks
When mounted onto ferromagnetic parts
switching distance of MS-332-3
may reduce.
Electromagnetical influences and magnetic
fields may change the switching behaviour of
the sensor.
Only non-ferromagnetic screws to be used for
mounting.
Matching actuator MSM-332 available as well.
Test Coil placed in vertical position
Reed Sensor diagonally centered in Test
Coil
Page 2 of 2
Rev.:
1.3
ms3323_ds_e_1.3
PIC Proximity Instrumentation Controls
Kontaktbauelemente GmbH
Nibelungenstr. 5 A
90530 Wendelstein, Germany
Phone
Fax
+49 911 99 59 06-0
+49 911 99 59 06-99
[email protected]