MEDICAL GRADE ISOLATION TRANSFORMERS Features ● Power Rating 50VA to 3000 VA ● Dual Primary and Dual Secondary windings ● Frequency 50-60Hz ● Isolation 5KVrms Primary-Secondary ● Creepage Distance minimum 8mm ● Leakage Current < 100µA ● Tolerance ±3% on load ● Various Mounting Methods available ● Recognized to UL60601-1 (Agency Reference - XORU2.E251176 & XORU8.E251176) ● Inbuilt Thermal Protection ● Magnetic Shield to minimize Strayfield Emission (Optional) ● Class B Insulation System ● Safety requirements conforms to IEC 601-1 Class I & II equipment ● RoHS Compliant : 2011/65/EU/ (RoHS 2) ● REACH Compliant (EC 1907/2006) Ratings Table Transformer Part Number Power 0050MD-X-00Y 0100MD-X-00Y 0200MD-X-00Y 0230MD-X-00Y 0300MD-X-00Y 0350MD-X-00Y 0400MD-X-00Y 0500MD-X-00Y 0600MD-X-00Y 0650MD-X-00Y 0760MD-X-00Y 0800MD-X-00Y (VA) 50 100 200 230 300 350 400 500 600 650 760 800 1000MD-X-00Y 1200MD-X-00Y 1500MD-X-00Y 1800MD-X-00Y 2000MD-X-00Y 2500MD-X-00Y 3000MD-X-00Y 1000 1200 1500 1800 2000 2500 3000 Secondary Ratings 120 VAC 240 VAC A (rms) A (rms) 0.42 0.21 0.83 0.42 1.67 0.83 1.92 0.96 2.50 1.25 2.92 1.46 3.33 1.67 4.17 2.08 5.00 2.50 5.42 2.71 6.33 3.17 6.67 3.33 8.33 10.00 12.50 15.00 16.67 20.83 25.00 4.17 5.00 6.25 7.50 8.33 10.42 12.50 No Load Voltage (V) 2x135.5 2x131.9 2x129.1 2x128.8 2x127.5 2x126.7 2x126.4 2x125.6 2x125.4 2x125.2 2x124.8 2x124.4 2x124.6 2x123.5 2x123.4 2x123.7 2x122.8 2x123.3 2x121.9 Physical Dimensions ** OD HT (mm) (mm) 81 38 99 41 117 56 117 61 127 62 132 58 132 64 134 70 150 70 157 70 160 71 165 72 168 183 200 206 215 240 265 80 81 90 94 105 115 120 Weight ** (KG) 0.8 1.1 2.3 2.4 2.8 3.0 3.4 4.3 4.7 5.1 5.9 6.1 8.2 10.0 11.8 13.6 15.5 21.0 26.0 ** Physical dimensions and weight given are approximate Germany: Int.+49 89 841 00 0 ● Ireland: Int.+35 374 954 8666 ● Czech Rep: Int.+420 377 338 351 ● India: Int.+91 427 2433 000 ● USA: Int. +1 573 303 3675 ext 802 http://www.talema nuvotem.com Initial Release June 2013 MEDICAL GRADE ISOLATION TRANSFORMERS Schematic 002 001 003 004 Schematic Construction Functional Earth 001 Reinforced insulation No No 002 Reinforced insulation No Yes (Internal, in-line) 003 Reinforced insulation Yes No 004 Reinforced insulation Yes Yes (Internal, in-line) Mechanical Specification Thermal Protection Ordering Code Mounting ● Center potted with through hole ● Metal Disc and Insulating pads (Optional) Germany: Int.+49 89 841 00 0 ● Ireland: Int.+35 374 954 8666 ● Czech Rep: Int.+420 377 338 351 ● India: Int.+91 427 2433 000 ● USA: Int. +1 573 303 3675 ext 802 http://www.talema nuvotem.com Initial Release June 2013