Ultra-low Profile Dome Array B3DA Ultra-low Profile Dome Array with Dust-Proof Construction and Crisp Clicking Action ■ No soldering required. Attach directly to PCB to make an ultra-low profile tactile switch. ■ Matrix adhesive used to create highly dust-proof construction with good ventilation. Omron’s unique circular contact action ensures a high level of resistance to foreign matter. ■ Lower profile, lighter weight, and crisp clicking action. ■ Customization of Dome Array available upon request (i.e., silver plating, number of contacts, shpae, etc.) RoHS Compliant Specifications ■ List of Models/Ratings/Characteristics Item Model 4-mm dia. versions Diameter 4 mm dia. Operating force (OF) 1.57±0.49 N {160±50 gf} Releasing force (RF) 0.2 N {20 gf} min. Pretravel (PT) 0.2±0.1 mm Height 0.25±0.1 mm Durability 500,000 operations min. Switching capacity 10 mA, 12 VDC (resistive) Recommended min. load: 1 mA, 3 VDC (resistive) 5-mm dia. versions 5 mm dia. 1,000,000 operations min. Ambient operating temperature −40 to 80°C (at 60% RH max.) with no icing or condensation. Ambient storage humidity 10% to 90% (at 40°C max.) Material Stainless steel Plating Unplated. silver Note: Contact dome specifications not shown in this table are also available. Consult Omron for customization requirements. 1 B3DA ■ B3DA Model Structure Stainless steel contact dome (circular contact) Cover film Matrix adhesive Separator Matrix Adhesive Circular Contact When Dome Arrays are attached to the PCB, any PCB dust or foreign particles will tend to collect in the center of the key when it is pressed. Therefore, poor contact occurs easily in Dome Arrays that provide contact at the center point only. The circular contact construction provides contact along the circumference of a circle, thus preventing poor contact by avoiding the center point. Conventional models The surface structure of this adhesive has grid-shaped slits, as shown in the following cross-sectional diagram. These slits provide both ventilation and dust-proofing, which is required for contact dome operation. Contact dome resistant to foreign matter (circular contact) Cover film 15 μm Matrix (acrylic) adhesive: 25 μm Cylindrical protrusion Slits Contact at center point Dimensions Note: All units are in millimeters, unless otherwise in diated. ■ Recommended Contact 4-mm Diameter Contact Dome 5.2 dia. 1.8 dia. 2.8 dia. Form 5-mm Diameter Contact Dome 6.2 dia. Gold-plated nickel 2.3 dia. Resist (30 to 50 μm) 3.8 dia. 5.2 dia. 1.8 dia. Gold-plated nickel Resist (30 to 50 μm) 6.2 dia. 2.3 dia. 2.8 dia. 3.8 dia. 2 Gold-plated nickel Gold-plated nickel Contact along circle circumference (circular contact) B3DA B3DA Sample for Engineering Reference B3DA-0000 Separator (paper) Sheet thickness (0.05) Contact dome 5 dia. diameter (18 keys) Cover film Operating force (OF) 1.57 ±0.49 N Plating Unplated Two, 2.1 dia. Contact dome (5 dia.) Thickness: 0.06 Four, R5 A-A cross section B enlarged B3DA-0010 Separator (paper) Sheet thickness (0.05) Contact dome 4 dia. diameter (18 keys) Cover film Operating force (OF) 1.57 ±0.49 N Plating Unplated Two, 2.1 dia. Contact dome (4 dia.) Thickness: 0.06 Four, R5 B enlarged A-A cross section Precautions ■ Attaching to the PCB ■ Washing Remove the Dome Array from the sheet using tweezers or a vacuum pick-up tool, and attach it above the contact on the PCB surface, which has been wiped clean in advance. Do not wash the Dome Array. The Dome Array is not water-resistant and must not be exposed to water or other liquids. Do not reuse a Dome Array that has been detached from the PCB. Attach a new Dome Array to the PCB. ■ Do not touch the Dome Array with bare hands, or with unclean gloves. Doing so may damage the Dome Array, which is the part that comes in contact with the PCB. ■ Common Precautions Be sure to read the safety precautions common to all Tactile Switches on pages for correct use. Reflow Soldering The Dome Array cannot withstand heat from reflow soldering. Always perform reflow soldering before attaching the Dome Array to the PCB. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. 3