Datasheet

New Product News
Slim D-Sub Connector
XM3-LS
Space-saving 9-pin Slim D-sub
Connectors for Boards
• Board mounting area is reduced by 33% (compared with
previous models) using depth of 8.4 mm.
• Nine D-sub right-angle DIP terminals.
• Mounting board thickness of either 1.0 mm or 1.6 mm.
Footprint on board reduced by 33% over previous models.
12.6 mm
8.4 mm
Reduced by
4.2 mm.
Previous model
■Ratings and Characteristics
Slim model
■Materials and Finish
Rated current
3A
Rated voltage
300 VAC
Housing
Contact resistance
20 mΩ max. (at 20 mVDC, 100 mA max.)
Insulation resistance
1,000 MΩ min. (at 500 VDC for 1 min)
Withstand voltage
1,000 VAC for 1 min (leakage current: 1 mA max.)
Insertion durability
100 times
Operating temperature
−25 to 105°C
Contacts
Shell
Fiber-glass reinforced PBT resin (UL94V-0)/black
Socket
Phosphor bronze/nickel base, flash gold plated
Plug
Brass/nickel base, flash gold plated
Steel/nickel plated
Anchors
Grounding fixture
Socket
M2.6 × 0.45: Steel/nickel plated
#4-40UNC: Stainless steel
Plug
Stainless steel
Phosphor bronze/tin plated
■Ordering Information
Socket
Plug
Minimum
ordering
quantity
(pieces)
Appearance
No. of contacts
Anchors
M2.6 × 0.45
#4-40 UNC
9
XM3B-0942-112LS
XM3B-0942-132LS
80
Minimum
ordering
quantity
(pieces)
Appearance
No. of contacts
Anchors
M2.6 × 0.45
#4-40 UNC
9
XM3C-0942-112LS
XM3C-0942-132LS
80
1
XM3-LS
Slim D-Sub Connector
■Dimensions
(Unit: mm)
30.8
24.99
16.3
2.74
Mounting Holes
(BOTTOM VIEW)
14.7
Anchors
Nin
e, 1 +0
.1
Tw
o, 3
.
12.5
7.9
2±
1.905
(2.6)
5.85
dia
.
0
0.1
dia
.
Board edge
Note: Applicable board thickness: 1.0 or 1.6 mm.
Plug XM3C-0942-1@2LS
Panel Cutout
14.5
5.8
Anchors
31.0 min.
5.8
Two, R3.2
11.4 min.
6.4 min.
8.3
30.8
24.99
16.92
2.74
12.5
2.84
24.99 ± 0.05
2.74 ± 0.05
4.9 max.
1.905 ± 0.05
2.84
Socket XM3B-0942-1@2LS
Four, R2.5
(2.6)
1.905
5.85
Note: Applicable panel thickness is 1.2 mm max.
Note: The mounting hole and panel cutout dimensions are the same for the Sockets and Plugs.
■Safety Precautions
Precautions for Correct Use
• Insert the connector into the board and then simultaneously
dip-solder the connector terminals and lock pins to the board.
• Pull or push the connector straight in or out when you connect or
disconnect it. Twisting it may cause damage or faulty contact.
• Do not remove the anchors from the connector. Removing the
anchors may cause damage or faulty contact.
Board
(t=1.6 mm)
Lock pin grounding fixture
●Automatic Soldering
Automated Soldering Conditions (Jet Flow)
(1) Soldering temperature: 250 ± 5°C
(2) Continuous soldering time: 5 ± 1 s max.
Board
(t=1.0 mm)
Lock pin grounding fixture
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company
Contact: www.omron.com/ecb
Cat. No. G022-E1-02
0413(1111)(W)