Pull-reset Safety Limit Switch D4N-@R CSM_D4N-_R_DS_E_5_1 A Series of Pull-reset Models Now Available Note: Contact your sales representative for details on models with safety standard certification. • Lineup includes three contact models with 2NC/1NO and 3NC contact forms in addition to the previous contact forms 1NC/ 1NO and 2NC. • M12-connector models are available, saving on labor and simplifying replacement. • Standardized gold-clad contacts provide high contact reliability. Can be used with both standard loads and microloads. • Conforms to EN115, EN81-1 and EN81-2. • Certified standards: UL, EN (TÜV), and CCC Be sure to read the “Safety Precautions” on page 12. Model Number Structure Model Number Legend D4N-@@@@R 1 2 3 1. Conduit size 1: Pg13.5 (1-conduit) 2: G1/2 (1-conduit) 4: M20 (1-conduit) 6: G1/2 (2-conduit) 8: M20 (2-conduit) 9: M12 connector (1-conduit) 2. Built-in Switch A: 1NC/1NO (slow-action) B: 2NC (slow-action) C: 2NC/1NO (slow-action) D: 3NC (slow-action) 3. Actuator 20: Roller lever (resin lever, resin roller) 2G:Adjustable roller lever, form lock (metal lever, resin roller) 2H:Adjustable roller lever, form lock (metal lever, rubber roller) 31: Top plunger 32: Top roller plunger 62: One-way roller arm lever (horizontal) 72: One-way roller arm lever (vertical) 1 D4N-@R Ordering Information List of Models Safety Limit Switches (with Direct Opening Mechanism) Consult with your OMRON representative when ordering any models that are not listed in this table. Built-in switch mechanism Actuator Conduit size 1NC/1NO (Slow-action) Model Roller lever (resin lever, resin roller) 1-conduit 2-conduit Adjustable roller lever, form lock (metal lever, resin roller) 1-conduit 2-conduit Adjustable roller lever, form lock (metal lever, rubber roller) 1-conduit 2-conduit Plunger 1-conduit 2-conduit Roller plunger 1-conduit 2-conduit One-way roller arm lever (horizontal) 1-conduit 2-conduit One-way roller arm lever (vertical) 1-conduit 2-conduit Direct opening 2NC (Slow-action) Model 2NC/1NO (Slow-action) Direct opening Model 3NC (Slow-action) Direct opening Model Pg13.5 D4N-1A20R D4N-1B20R D4N-1C20R D4N-1D20R G1/2 D4N-2A20R D4N-2B20R D4N-2C20R D4N-2D20R M20 D4N-4A20R D4N-4B20R D4N-4C20R D4N-4D20R M12 connector D4N-9A20R D4N-9B20R --- --- G1/2 D4N-6A20R D4N-6B20R D4N-6C20R D4N-6D20R M20 D4N-8A20R D4N-8B20R D4N-8C20R D4N-8D20R Pg13.5 D4N-1A2GR D4N-1B2GR D4N-1C2GR D4N-1D2GR G1/2 D4N-2A2GR D4N-2B2GR D4N-2C2GR D4N-2D2GR M20 D4N-4A2GR D4N-4B2GR D4N-4C2GR D4N-4D2GR M12 connector D4N-9A2GR D4N-9B2GR --- --- G1/2 D4N-6A2GR D4N-6B2GR D4N-6C2GR D4N-6D2GR M20 D4N-8A2GR D4N-8B2GR D4N-8C2GR D4N-8D2GR Pg13.5 D4N-1A2HR D4N-1B2HR D4N-1C2HR D4N-1D2HR G1/2 D4N-2A2HR D4N-2B2HR D4N-2C2HR D4N-2D2HR M20 D4N-4A2HR D4N-4B2HR D4N-4C2HR D4N-4D2HR M12 connector D4N-9A2HR D4N-9B2HR --- --- G1/2 D4N-6A2HR D4N-6B2HR D4N-6C2HR D4N-6D2HR M20 D4N-8A2HR D4N-8B2HR D4N-8C2HR D4N-8D2HR Pg13.5 D4N-1A31R D4N-1B31R D4N-1C31R D4N-1D31R G1/2 D4N-2A31R D4N-2B31R D4N-2C31R D4N-2D31R M20 D4N-4A31R D4N-4B31R D4N-4C31R D4N-4D31R M12 connector D4N-9A31R D4N-9B31R --- --- G1/2 D4N-6A31R D4N-6B31R D4N-6C31R D4N-6D31R M20 D4N-8A31R D4N-8B31R D4N-8C31R D4N-8D31R Pg13.5 D4N-1A32R D4N-1B32R D4N-1C32R D4N-1D32R G1/2 D4N-2A32R D4N-2B32R D4N-2C32R D4N-2D32R M20 D4N-4A32R D4N-4B32R D4N-4C32R D4N-4D32R M12 connector D4N-9A32R D4N-9B32R --- --- G1/2 D4N-6A32R D4N-6B32R D4N-6C32R D4N-6D32R M20 D4N-8A32R D4N-8B32R D4N-8C32R D4N-8D32R Pg13.5 D4N-1A62R D4N-1B62R D4N-1C62R D4N-1D62R G1/2 D4N-2A62R D4N-2B62R D4N-2C62R D4N-2D62R M20 D4N-4A62R D4N-4B62R D4N-4C62R D4N-4D62R M12 connector D4N-9A62R D4N-9B62R --- --- G1/2 D4N-6A62R D4N-6B62R D4N-6C62R D4N-6D62R M20 D4N-8A62R D4N-8B62R D4N-8C62R D4N-8D62R Pg13.5 D4N-1A72R D4N-1B72R D4N-1C72R D4N-1D72R G1/2 D4N-2A72R D4N-2B72R D4N-2C72R D4N-2D72R M20 D4N-4A72R D4N-4B72R D4N-4C72R D4N-4D72R M12 connector D4N-9A72R D4N-9B72R --- --- G1/2 D4N-6A72R D4N-6B72R D4N-6C72R D4N-6D72R M20 D4N-8A72R D4N-8B72R D4N-8C72R D4N-8D72R Direct opening 2 D4N-@R Specifications Standards and EC Directives Certified Standard Ratings Conforms to the following EC Directives: TÜV (EN60947-5-1), CCC (GB14048.5) • • • • • • Machinery Directive Low Voltage Directive EN50047 EN60204-1 EN ISO 14119 GS-ET-15 Rated operating current (Ie) TÜV SÜD AC-15 DC-13 3A 0.27 A Rated operating voltage (Ue) 240 V 250 V Note: Use a 10 A fuse type gI or gG that conforms to IEC60269 as a short-circuit protection device. This fuse is not built into the Switch. Certified Standards Certification body Utilization category Item Standard EN60947-5-1 (certified direct opening) File No. *1 UL *2 UL508, CSA C22.2 No.14 E76675 CQC (CCC) *3 GB14048.5 2004010305105973 *1. Consult your OMRON representative for details. *2. Certification for CSA C22.2 No. 14 is authorized by the UL mark. *3. Ask your OMRON representative for information on certified models. UL/CSA (UL508, CSA C22.2 No. 14) A300 Rated voltage 120 VAC 240 VAC Carry current 10 A Current (A) Make Break 60 6 30 3 Volt-amperes (VA) Make 7,200 Break 720 Q300 Rated voltage 125 VDC 250 VDC Carry current 2.5 A Current (A) Make Break 0.55 0.55 0.27 0.27 Volt-amperes (VA) Make 69 Break 69 3 D4N-@R Characteristics Degree of protection *1 Durability *2 IP67 (EN60947-5-1) Mechanical 1,000,000 operations min. Electrical 500,000 operations min. (3 A resistive load at 250 VAC) *3 300,000 operations min. (10 A resistive load at 250 VAC) Operating speed 1 to 500 mm/s (D4N-1A20R) Operating frequency 30 operations/minute max. Contact resistance 25 mΩ max. Minimum applicable load *4 1 mA resistive load at 5 VDC (N-level reference value) Rated insulation voltage (Ui) 300 V Rated frequency 50/60 Hz Protection against electric shock Class II (double insulation) Pollution degree (operating environment) 3 (EN60947-5-1) Impulse withstand voltage (EN60947-5-1) Between terminals of same polarity 2.5 kV Between terminals of different polarity 4 kV Between each terminal and non-current carrying 6 kV metallic parts Insulation resistance 100 MΩ min. 2 × 2 mm min. Contact gap Vibration resistance Shock resistance Malfunction 10 to 55 Hz, 0.75 mm single amplitude Destruction 1,000 m/s2 Malfunction 300 m/s2 Conditional short-circuit current 100 A (EN60947-5-1) Conventional free air thermal current (Ith) 10 A (EN60947-5-1) Ambient operating temperature −30 to 70°C (with no icing) Ambient operating humidity 95% max. Weight Approx. 92 g (D4N-1A20R) Note: 1. The above values are initial values. 2. Once a contact has been used to switch a standard load, it cannot be used for a load of a smaller capacity. Doing so may result in roughening of the contact surface and contact reliability may be lost. *1. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the D4N-@R in places where foreign material such as dust, dirt, oil, water, or chemicals may penetrate through the head. Otherwise, accelerated wear, Switch damage or malfunctioning may occur. *2. The durability is for an ambient temperature of 5 to 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON representative. *3. Do not pass the 3 A, 250 VAC load through more than 2 circuits. *4. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual load beforehand. 4 D4N-@R Structure and Nomenclature Structure Safety-oriented Lever Setting (Form lock mechanism) Grooves which engage the lever are cut in the lever and rotary shaft to prevent the lever from slipping against the rotary shaft. The actuator locks (self-holding) when it moves to the lock position. Head The direction of the Switch Head can be adjusted to any of the four directions, except for Switches with Roller Plungers, which can be adjusted to either of two directions differing by 90°C. Reset Head (Blue) The direction of the reset head can be adjusted to any of the four directions. Conduit A wide variety of conduits is available. Built-in Switch The built-in switch has a direct opening mechanism that forcibly separates the NC contact even when there is contact deposit. Size Cover The cover, with a hinge on its lower part, can be opened by removing the screw of the cover, which ensures ease of maintenance and wiring. Box 1-conduit model 2-conduit model Pg13.5 Yes --- G1/2 Yes Yes M20 Yes Yes M12 connector Yes --- Note: M12 connector types are not available for Switches with three contacts. Contact Form Model Contact Contact form Zb D4N-@A@R 1NC/1NO 11 12 33 34 Zb D4N-@B@R 2NC 11 12 31 Operating pattern 11-12 33-34 Remarks ON Stroke 11-12 31-32 The terminals 11-12 and 33-34 can be used as unlike poles. ON Stroke 32 Zb D4N-@C@R 2NC/1NO 11 12 21 22 33 34 Zb D4N-@D@R 3NC 11 12 21 22 31 32 11-12 21-22 33-34 ON Stroke 11-12 21-22 31-32 ON Stroke Only NC contacts 11-12 have a certified direct opening mechanism. Only NC contacts 11-12 and 31-32 have a certified direct opening mechanism. The terminals 11-12 and 31-32 can be used as unlike poles. Only NC contacts 11-12 and 21-22 have a certified direct opening mechanism. The terminals 11-12, 21-22, and 33-34 can be used as unlike poles. Only NC contacts 11-12, 21-22, and 31-32 have a certified direct opening mechanism. The terminals 11-12, 21-22, and 31-32 can be used as unlike poles. 5 D4N-@R Direct Opening Mechanism 1NC/1NO Contact (Slow-action) Fixed contact (NC) Contact spring Movable contacts Fixed contact (NO) Plunger Return spring Conforms to EN60947-5-1 Direct Opening (Only NC Contact has a direct opening mechanism.) When contact welding occurs, the contacts are separated from each other by the plunger being pushed in. 2NC Contact (Slow-action) Fixed contact (NC) Movable contact Contact spring Plunger Return spring Conforms to EN60947-5-1 Direct Opening (Both NC Contacts have a direct opening mechanism.) When contact welding occurs, the contacts are separated from each other by the plunger being pushed in. 6 D4N-@R Dimensions and Operating Characteristics (Unit: mm) Switches 1-conduit Models Adjustable Roller Lever, Form Lock (with Metal Lever, Resin Roller) D4N-1@2GR D4N-2@2GR D4N-4@2GR D4N-9@2GR * Roller Lever (Resin Lever, Resin Roller) D4N-1@20R D4N-2@20R D4N-4@20R D4N-9@20R * 47±1 17.5 dia. × 6.8 resin roller Blue (27) 11±0.2 26R Resin lever 40±1 Blue 20.5 × 20.5 14 dia. 17.5 dia. × 6.8 resin roller 20 to 66R 45±1 39.5±1 (31) 11±0.2 20.5 × 20.5 43.5 34 9±0.2 16.7 21.5 2.5 20±0.1 22±0.1 2.15±0.05R mounting holes 47±0.2 14 dia. 25 43.5 34 16.7 9±0.2 55 21.5 2.5 2.15±0.05R mounting holes 22±0.2 31 max. Conduit cap 20±0.1 22±0.1 47±0.2 55 14.2 30 36 Two, 4+0.15 dia. holes 0 Depth: 5 22±0.2 31 max. Resin bearing 14.2 30 Two, 4+0.15 dia. 0 holes Depth: 5 1-conduit M12 Connectors Adjustable Roller Lever, Form Lock (with Metal Lever, Rubber Roller) D4N-1@2HR D4N-2@2HR D4N-4@2HR D4N-9@2HR * 50 dia. × 8 rubber roller Conduit cap D4N-9@@@R 48.2±1 41.3±1 (29.2) (14) Blue M12 × 1 11±0.2 32 to 66R (P:2) 14.2 30 20.5 × 20.5 14 dia. 25 43.5 34 16.7 9±0.2 21.5 2.5 20±0.1 22±0.1 2.15±0.05R mounting holes 47±0.2 55 Stainless steel lever 22±0.2 31 max. 14.2 30 Conduit cap Two, 4+0.15 dia. holes 0 Depth: 5 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. * Refer to the right above diagram for details on 1-conduit M12 connectors. Operating characteristics Model D4N-@@20R D4N-@@2GR D4N-@@2HR *1 Locking force LF max. 6.4 N 5.6 N 5.4 N Locking travel LT max. 55° 55° 55° Pretravel PT 1 *2 18 to 27° 18 to 27° 18 to 27° Pretravel (PT 2) *3 (44°) (44°) (44°) Total travel (TT) *4 80° 80° 80° Direct opening force DOF min. *5 20 N 20 N 20 N 50° 50° 50° Direct opening travel DOT min. *5 Note: Variation occurs in the simultaneity of contact opening/closing operations of 2NC, 2NC/1NO, and 3NC contacts. Check contact operation. *1. The operating characteristics of these Switches were measured with the roller lever set at 32 mm. *2. These PT values are possible when the NC contacts are open (OFF). *3. These PT values are reference values possible when the NO contacts are closed (ON). (1NC/1NO models only) *4. Reference value. *5. For safe use, always make sure that the minimum values or greater are provided. 7 D4N-@R 1-conduit Models Plunger D4N-1@31R D4N-4@31R Roller Plunger D4N-1@32R D4N-2@32R D4N-4@32R D4N-9@32R * D4N-2@31R D4N-9@31R * Blue Blue 20.5 × 20.5 6 dia. 14 dia. OP 9.5 dia. × 5 resin roller 21.5 11±0.2 11±0.2 14 dia. OP 41 (27) 2.5 20±0.1 22±0.1 2.15±0.05R mounting holes 9±0.2 47±0.2 55 Conduit cap 22±0.2 31 max. 2.5 16.7 9±0.2 2.15±0.05R mounting holes 14.2 Two, 4+0.15 dia. 0 30 11±0.2 11±0.2 55 Conduit cap 14.2 Two, 4+0.15 dia. 0 30 holes Depth: 5 35.5±0.2 39.3 2.5 21.5 12 dia. × 5 resin roller 11± 0.2 19R 14.7 20R 14 dia. OP OP 12 Blue 21.5 12 dia. × 5 resin roller 13.5 47±0.2 One-way Roller Arm Lever (Vertical) D4N-1@72R D4N-2@72R D4N-4@72R D4N-9@72R * 14.8 11±0.2 16.7 36 One-way Roller Arm Lever (Horizontal) D4N-1@62R D4N-2@62R D4N-4@62R D4N-9@62R * Operating direction 20±0.1 22±0.1 22±0.2 31 max. holes Depth: 5 36 Blue 21.5 20.5 × 20.5 10.2 10.2 14 dia. 35.5±0.2 9±0.2 16.7 16.7 9±0.2 2.5 20±0.1 22±0.1 2.15±0.05R mounting holes 47±0.2 2.15±0.05R mounting holes 55 20±0.1 22±0.1 47±0.2 55 Operating direction 22±0.2 31 max. Conduit cap 14.2 30 36 22±0.2 31 max. Two, 4+0.15 dia. 0 holes Conduit cap 14.2 Two, 4+0.15 dia. 30 0 36 Depth: 5 holes Depth: 5 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. * Refer to page 7 for details on 1-conduit M12 connectors. Model Operating characteristics D4N-@@31R D4N-@@32R D4N-@@62R D4N-@@72R Locking force LF max. 10.8 N 10.8N 7.5 N 7.9 N Locking travel LT max. 4.5 mm 4.5 mm 7 mm 7 mm Pretravel PT 1 max. *1 2 mm 2 mm 4 mm 4 mm Pretravel (PT 2) *2 (2.9 mm) (2.9 mm) (5.2 mm) Operating position OP 34 ±0.5 mm 44.4 ±0.8 mm 53 ±0.8 mm 27 ±0.8 mm Total travel (TT) *3 (6 mm) (4.3 mm) (6 mm) (9 mm) (9 mm) Direct opening force DOF min. *4 20 N 20 N 20 N 20 N Direct opening travel DOT min. *4 3.2 mm 3.2 mm 5.8 mm 4.8 mm Note: Variation occurs in the simultaneity of contact opening/closing operations of 2NC, 2NC/1NO, and 3NC contacts. Check contact operation. *1. These PT values are possible when the NC contacts are open (OFF). *2. These PT values are reference values possible when the NO contacts are closed (ON). (1NC/1NO models only) *3. Reference value. *4. For safe use, always make sure that the minimum values or greater are provided. 8 D4N-@R 2-conduit Models Roller Lever (Resin Lever, Resin Roller) D4N-6@20R D4N-8@20R 47±1 40±1 17.5 dia. × 6.8 resin roller Blue Adjustable Roller Lever, Form Lock (with Metal Lever, Resin Roller) D4N-6@2GR D4N-8@2GR (27) Blue 26R Resin lever 45±1 39.5±1 17.5 dia. × 6.8 resin roller 11±0.2 (31) 20.5 × 20.5 14 dia. 11±0.2 20 to 66R 20.5 × 20.5 2.5 34 5.4 43.5 9±0.2 20±0.1 22±0.1 40±0.1 42±0.1 2.15±0.05R mounting holes 25 16.7 21.5 42±0.2 56 max. 2.5 2.15±0.05R mounting holes Conduit cap (3) 14.2 30 Two, 4 20±0.1 22±0.1 40±0.1 42±0.1 42±0.2 56 max. 36 +0.15 0 21.5 9±0.2 47 Cap Conduit cap 43.5 34 5.4 20.5 39±0.2 25 dia. 14 dia. dia. holes 20.5 39±0.2 25 dia. 16.7 47 Cap (3) 14.2 30 Two, 4+0.15 dia. holes 0 Depth: 5 Depth: 5 Adjustable Roller Lever, Form Lock (with Metal Lever, Rubber Roller) D4N-6@2HR D4N-8@2HR Blue 48.2±1 41.3±1 Resin bearing 50 dia. × 8 rubber roller (29.2) 11±0.2 32 to 66R (P:2) 25 20.5 × 20.5 Stainless steel lever 14 dia. 43.5 34 5.4 2.5 21.5 9±0.2 2.15±0.05R mounting holes 20±0.1 22±0.1 40±0.1 42±0.1 20.5 39±0.2 25 dia. 47 Cap Conduit cap 42±0.2 56 max. 16.7 (3) 14.2 30 Two, 4+0.15 dia. holes 0 Depth: 5 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Model Operating characteristics D4N-@@20R D4N-@@2GR D4N-@@2HR Locking force LF max. 6.4 N 5.6 N 5.4 N Locking travel LT max. 55° 55° 55° Pretravel PT 1 *1 18° to 27° 18° to 27° 18° to 27° Pretravel (PT 2) *2 (44°) (44°) (44°) Total travel (TT) *3 80° 80° 80° Direct opening force DOF min. *4 20 N 20 N 20 N Direct opening travel DOT min. *4 50° 50° 50° Note: Variation occurs in the simultaneity of contact opening/closing operations of 2NC, 2NC/1NO, and 3NC contacts. Check contact operation. *1. These PT values are possible when the NC contacts are open (OFF). *2. These PT values are reference values possible when the NO contacts are closed (ON). (1NC/ 1NO models only) *3. Reference value. *4. For safe use, always make sure that the minimum values or greater are provided. 9 D4N-@R 2-conduit Models Roller Plunger D4N-6@32R D4N-8@32R Plunger D4N-6@31R D4N-8@31R 9.5 dia. × 5 resin roller 20.5 × 20.5 21.5 OP OP 41 2.5 (27) 5.4 9±0.2 20±0.1 22±0.1 40±0.1 42±0.1 2.15±0.05R mounting holes 9±0.2 20.5 47 42±0.2 56 max. (3) 14.2 30 20±0.1 22±0.1 40±0.1 42±0.1 2.15±0.05R mounting holes Cap Conduit cap Blue 2.5 5.4 16.7 39±0.2 25 dia. 11±0.2 14 dia. 11±0.2 6 dia. 14 dia. 21.5 20.5 × 20.5 16.7 20.5 39±0.2 25 dia. 47 Cap Conduit cap 42±0.2 56 max. Blue (3) 14.2 30 36 36 dia. holes Two, 4+0.15 0 Two, 4+0.15 dia. holes 0 Depth: 5 Depth: 5 One-way Roller Arm Lever (Vertical) D4N-6@72R D4N-8@72R One-way Roller Arm Lever (Horizontal) D4N-6@62R D4N-8@62R Operating direction 14.8 11±0.2 21.5 11±0.2 12 dia. x 5 resin roller 13.5 35.5±0.2 39.3 5.4 10.2 20.5 39±0.2 25 dia. 2.15±0.05R mounting holes 47 9±0.2 42±0.2 56 max. (3) 20±0.1 22±0.1 40±0.1 42±0.1 42±0.2 56 max. 14.2 30 20.5 39±0.2 25 dia. 47 Operating direction Conduit cap Cap 35.5±0.2 2.5 16.7 Conduit cap Blue 14.7 5.4 2.5 20±0.1 22±0.1 40±0.1 42±0.1 11±0.2 14 dia. 10.2 9±0.2 2.15±0.05R mounting holes 21.5 12 dia. × 5 resin roller 19R 20R 14 dia. OP OP 12 11±0.2 (3) Cap 14.2 30 36 36 Two, 4+0.15 dia. holes 0 Depth: 5 Blue Two, 4+0.15 dia. holes 0 Depth: 5 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Model Operating characteristics D4N-@@31R D4N-@@32R D4N-@@62R D4N-@@72R Locking force LF max. 10.8 N 10.8N 7.5 N 7.9 N Locking travel LT max. 4.5 mm 4.5 mm 7 mm 7 mm Pretravel PT 1 max. *1 Pretravel (PT 2) *2 Operating position OP Total travel (TT) *3 Direct opening force DOF min. *4 Direct opening travel DOT min. *4 2 mm 2 mm 4 mm 4 mm (2.9 mm) (2.9 mm) (5.2 mm) (4.3 mm) Note: Variation occurs in the simultaneity of contact opening/ closing operations of 2NC, 2NC/1NO, and 3NC contacts. Check contact operation. *1. These PT values are possible when the NC contacts are open (OFF). 34 ±0.5 mm 44.4 ±0.8 mm 53 ±0.8 mm 27 ±0.8 mm *2. These PT values are reference values possible when the (6 mm) (6 mm) (9 mm) (9 mm) NO contacts are closed (ON). (1NC/1NO models only) 20 N 20 N 20 N 20 N *3. Reference value. 3.2 mm 3.2 mm 5.8 mm 4.8 mm *4. For safe use, always make sure that the minimum values or greater are provided. 10 D4N-@R Levers Refer to the following diagrams for the angles and positions of the dogs. Roller Lever (D4N-@@20R) Adjustable Roller Lever, Form Lock (with Metal Lever, Rubber Roller) (D4N-@@2HR) Adjustable Roller Lever, Form Lock (with Metal Lever, Resin Roller) (D4N-@@2GR) 40±2 30° 10 min. 40±2 10 min. 42±2 Dog 45 min. 10 min. Dog Dog 20 min. 30° 30° 40 min. 25 min. 5 min. 56+10 15 min. 86+10 71+10 30° 71+10 51+10 50 65R 31R 65R 20R Sealed Plunger (D4N-@@31R) Roller Plunger (D4N-@@32R) 0 12.5 −2.5 0 12.5 −2.5 Dog Dog Dog Dog 31 min. 41+10 41 min. 10 min. One-way Roller Arm Lever (Vertical) (D4N-@@72R) One-way Roller Arm Lever (Horizontal) (D4N-@@62R) 0 12.5 −2.5 Dog 0 12.5 −2.5 10 min. 20 min. 30° 47+10 2.5 20 min. 30° 30° 5 min. 5 min. Dog 30 max. 10 min. 22+10 20 min. Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. 11 D4N-@R Safety Precautions ● Be sure to read the precautions for all D4N-@R models in the website at: http://www.ia.omron.com/. !CAUTION Switch Mounting Electric shock may occasionally occur. Do not use metal connectors or metal conduits. Precautions for Safe Use • Do not use the Switch submerged in oil or water, or in locations continuously subject to splashes of oil or water. Doing so may result in oil or water entering the Switch interior. (The IP67 degree of protection specification for the Switch refers to water penetration while the Switch is submersed in water for a specified period of time.) • Always attach the cover after completing wiring and before using the Switch. Also, do not turn ON the Switch with the cover open. Doing so may result in electric shock. • Do not switch circuits for two or more standard loads (250 VAC, 3 A). Doing so may adversely affect insulation performance. • Make sure that the actuator is pushed into the lock position. Not doing so may result in the actuator becoming unlocked, causing an accident. • Always reset the Switch manually. Not doing so may result in damage to the reset function. • Mount the Switch using M4 screws and spring washers and tighten the screws to the specified torque. • For safety, use screws that cannot be easily removed, or use an equivalent measure to ensure that the Switch is secure. • As shown below, two studs with a maximum height of 4.8 mm and a diameter of 4 −0.05 −0.15 mm can be provided, the studs inserted into the holes on the bottom of the Switch, and the Switch secured at four locations to increase the mounting strength. Switch Mounting Holes One-conduit Type 2.5±0.1 Two, M4 20±0.1 22±0.1 47±0.1 Mounting hole Mounting surface Mounting pin insertion hole 4−0.05 −0.15 dia. height, 4.8 max. 22±0.1 −0.05 4 −0.15 dia. height, 4.8 max. Precautions for Correct Use The Switch contacts can be used with either standard loads or microloads. Once the contacts have been used to switch a load, however, they cannot be used to switch smaller loads. The contact surfaces will become rough once they have been used and contact reliability for smaller loads may be reduced. Two-conduit Type Two, M4 2.5±0.1 5.35±0.1 39±0.1 Mounting Method Appropriate Tightening Torque Tighten each of the screws to the specified torque. Loose screws may result in malfunction of the Switch within a short time. 20±0.1 22±0.1 40±0.1 42±0.1 42±0.1 4−0.05 −0.15 dia. height, 4.8 max. 1 Terminal screw 0.6 to 0.8 N·m 2 Cover mounting screw 0.5 to 0.7 N·m 3 Head mounting screw 0.5 to 0.6 N·m Changing the Head Direction 4 Lever mounting screw 1.6 to 1.8 N·m 5 Body mounting screw 0.5 to 0.7 N·m 6 Connector, M12 adaptor 1.8 to 2.2 N·m 7 Cap screw By removing the four screws of the head, the mounting direction of the head can be changed. The head can be mounted in four directions. Be sure that no foreign material will enter the head during a change in direction. 1.3 to 1.7 N·m Changing the Lever 3 The lever mounting screws can be used to set the lever position to any position in a 360° angle at 7.5° increments. Grooves are incised on the lever and rotary shaft that engage to prevent the lever from slipping against the rotary shaft. The screws on adjustable roller lever models can also loosened to change the length of the lever. Remove the screws from the front of the lever before mounting the lever in reverse (front/back), and set the level so that operation will be completed before exceeding a range of 180° on the horizontal. 4 5 1 7 2 6 12 D4N-@R Wiring Wiring Contact Arrangement • When connecting to the terminals via insulating tube and M3.5 crimp terminals, arrange the crimp terminals as shown below so that they do not rise up onto the case or the cover. Applicable lead wire size: AWG20 to AWG18 (0.5 to 0.75 mm2). Use lead wires of an appropriate length, as shown below. Not doing so may result in excess length causing the cover to rise and not fit properly. One-conduit Type (3 Poles) B 11 12 C D E C 21 22 D E 33 34 F D4N-@D@@R (3NC) F 42 mm 33 mm 28 mm D4N-@C@@R (2NC/1NO) 11 12 11 12 21 22 21 22 31 32 33 34 D4N-@B@@R (2NC) AB A • The contact arrangements are shown below. Screw Terminal Type D4N-@A@@R (1NC/1NO) 11 12 11 12 31 32 33 34 Connector Type Tolerance ±2 mm D4N-9B@@R (2NC) Two-conduit Type (3 Poles) Left hand BD F ECA A 11 12 2 B 21 22 D E 33 34 F 42 mm 42 mm 28 mm 28 mm Tolerance ±2 mm Tolerance ±2 mm • Do not push crimp terminals into gaps in the case interior. Doing so may cause damage or deformation of the case. • Use crimp terminals not more than 0.5 mm in thickness. Otherwise, they will interfere with other components inside the case. [Reference] The crimp terminals shown below are not more than 0.5 mm thick. Manufacturer J.S.T. Mfg. Co. t: dz dia.: D dia.: B: L: F: I: Type FN0.5-3.7 (F Type) L l (3) 31 32 (4) Pin No. (Terminal No.) D4N-9A@@R (1NC/1NO) (1) 11 12 (2) (3) 33 34 (4) • Applicable socket: XS2F-D421 series (OMRON). • Refer to the Connector Catalog for details on socket pin numbers and lead wire colors. Socket Tightening (Connector Type) • Turn the socket connector screws by hand and tighten until no space remains between the socket and the plug. • Make sure that the socket connector is tightened securely. Otherwise, the rated degree of protection (IP67) may not be maintained and vibration may loosen the socket connector. Conduit Opening N0.5-3.7 (Straight Type) 0.5 mm 3.7 mm 2.9 mm 6.6 mm 19 mm 7.7 mm 8.0 mm 12 (2) 4 3 ECA BD F C (1) 11 1 Right hand F B D dia. • Connect a recommended connector to the opening of the conduit and tighten the connector to the specified torque. The case may be damaged if an excessive tightening torque is applied. • Use a cable with a suitable diameter for the connector. • Attach and tighten a conduit cap to the unused conduit opening when wiring. Tighten the conduit cap to the specified torque. The conduit cap is provided with the Switch (2-conduit types). dz dia. Crimp terminal Correct Terminal screw Incorrect 13 D4N-@R Recommended Connectors Use connectors with screws not exceeding 9 mm, otherwise the screws will protrude into the case interior, interfering with other components in the case. The connectors listed in the following table have connectors with thread sections not exceeding 9 mm. Use the recommended connectors to ensure conformance to IP67. Size Manufacturer Model Applicable cable diameter G1/2 LAPP ST-PF1/2 5380-1002 6.0 to 12.0 mm Pg13.5 LAPP ST-13.5 5301-5030 6.0 to 12.0 mm M20 LAPP ST-M20 × 1.5 5311-1020 7.0 to 13.0 mm Use LAPP connectors together with seal packing (JPK-16, GP-13.5, or GPM20), and tighten to the specified tightening torque. Seal packing is sold separately. • LAPP is a German manufacturer. Others • When attaching a cover, be sure that the seal rubber is in place and that there is no foreign material present. If the cover is attached with the seal rubber out of place or if foreign material is stuck to the rubber, a proper seal will not be obtained. • Do not use any screws to connect the cover other than the specified ones. The seal characteristics may be reduced. • With rubber roller lever models, the rubber roller may turn white over time, but this will not affect the quality of operation. • Use the following recommended countermeasures to prevent telegraphing when using adjustable or long levers. 1. Make the rear edge of the dog smooth with an angle of 15° to 30° or make it in the shape of a quadratic curve. 2. Design the circuit so that no error signal will be generated. 14 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron’s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2015.4 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2015 All Right Reserved.