Catalog

A6R/A6RV
Rotary DIP Switch
Through-hole mounting Rotary DIP
Switches
● Top/Side-actuated, and Flat/Extended-actuator
models available.
● Actuator with an O-ring sealed structure prevents
the ingress of dirt and dust.
● Two different terminal arrangements allow the
flexibility of circuit design.
RoHS Compliant
■List of Models
Type (actuator color)
Number of Quantity
positions per tube
10
16
48
48
Terminal
arrangement
Top-actuated,
flat (white)
Top-actuated,
extended actuator
(white)
Side-actuated, flat
(white)
Side-actuated,
extended actuator
(white)
A6R-101RF
A6R-101RS
A6RV-101RF
A6RV-101RS
A6R-102RF
A6R-102RS
A6RV-102RF
A6RV-102RS
A6R-161RF
A6R-161RS
A6RV-161RF
A6RV-161RS
A6R-162RF
A6R-162RS
A6RV-162RF
A6RV-162RS
Output code
4×1
3×3
4×1
3×3
BCD Decimal
BCD
Hexadecimal
Note: Order in multiples of the package quantity.
■Ratings/Characteristics
25 mA at 24 VDC, 10 μA (minimum current)
at 3.5 VDC
Ratings
Ambient operating temperature
–25 to +80°C 60%RH max.
(with no icing or condensation)
Ambient operating
humidity
35% to 95% (at +5 to +35°C)
Insulation resistance
100 MΩ min. (at 250 VDC)
Contact resistance
200 mΩ max. (initial value)
Dielectric
strength
Between
terminals
250 VAC for 1 min
Vibration
resistance
Malfunction
10 to 55 Hz, 1.5-mm double amplitude
Shock
resistance
Malfunction
300 m/s2 min.
Durability
Electrical
5,000 steps min.
Operating torque
1.96 × 10−2 N·m {2 gf·m} max.
Weight
Top-actuated: Approx. 0.6 g
Side-actuated: Approx. 0.8 g
(Add 0.13 g for the extended-actuator type of
each model.)
■Output Codes
10-position Models
Code
Position
0
1
2
3
4
5
6
7
8
9
16-position Models
BCD Decimal
code
1
2
4
8
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Code
Position
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
BCD Hexadecimal
code
1
2
4
8
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Note: “●” indicates that the internal switch is ON.
1
A6R/A6RV
A6R/A6RV
■Dimensions
(Unit: mm)
● Top-actuated Flat Models with 4×1 Terminal
Arrangement
● Top-actuated Extended-actuator Models with 4×1
Terminal Arrangement
A6R-101RF
A6R-161RF
A6R-101RS
A6R-161RS
9.8
1
2.9
A6R-161RF
9.8
1
9.9
9.9
A6R-101RF
A6R-161RS
A6R-101RS
4 dia.
4.5
3.25
1.2
3.5
0.55
7.3
0.25
2.54
4.5
7.62±0.5
3.25
3.5
0.55
0.25
2.54
7.62±0.5
● Top-actuated Flat Models with 3×3 Terminal
Arrangement
● Top-actuated Extended-actuator Models with 3×3
Terminal Arrangement
A6R-102RF
A6R-162RF
A6R-102RS
A6R-162RS
9.8
1
2.9
A6R-162RF
9.8
1
9.9
9.9
A6R-162RS
A6R-102RF
A6R-102RS
4 dia.
4.5
3.25
1.2
3.5
0.25
0.55
2.54
7.3
4.5
7.62±0.5
3.25
3.5
0.25
0.55
2.54
7.62±0.5
● Side-actuated Flat Models with 4×1 Terminal
Arrangement
● Side-actuated Extended-actuator Models with 4×1
Terminal Arrangement
A6RV-101RF
A6RV-161RF
A6RV-101RS
A6RV-161RS
1.2
9.8
9.8
1
2.9
1
9.9
A6RV-101RF
3.38
0.25
2.54±0.3
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2
6.64
3.3
2.54
0.55
7.3
9.9 4 dia.
3.3
0.3
A6RV-161RF
6.64
A6RV-161RS
0.25
2.54
0.55
A6RV-101RS
3.38
2.54±0.3
A6R/A6RV
A6R/A6RV
● Side-actuated Flat Models with 3×3 Terminal
Arrangement
● Side-actuated Extended-actuator Models with 3×3
Terminal Arrangement
A6RV-102RF
A6RV-162RF
A6RV-102RS
A6RV-162RS
1.2
9.8
9.8
1
2.9
0.3
0.55
7.3
9.9
9.9 4 dia.
3.3
3.3
0.25
2.54±0.3
2.54
3.38
A6RV-162RF
1
6.64
0.55
6.64
0.25
2.54
3.38
A6RV-102RF
A6RV-162RS
2.54±0.3
A6RV-102RS
■PCB Dimensions
● Top-actuated Models
4×1 Terminal
Arrangement
● Side-actuated Models
4×1 Terminal
3×3 Terminal
Arrangement
Arrangement
3×3 Terminal
Arrangement
Five, 0.9±0.1 dia.
8
C
7.62±0.1
Five, 0.9±0.1 dia.
8
4
2
C
8
1
2.54±0.1
P=2.54±0.1
C
Six, 0.9±0.1 dia.
C
7.62±0.1
Six, 0.9±0.1 dia.
1
2.54±0.1
2.54±0.1
2
2
4
1
8
C
2
1
C
4
4
P=2.54±0.1
2.54±0.1
P: Pole Numbers
2.54±0.1
2.54±0.1
Actuator side
Actuator side
P: Pole Numbers
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
■Internal Connections
Contact Form (Top View)
● Top-actuated Models
4×1 Terminal
3×3 Terminal
Arrangement
Arrangement
C
8
C
● Side-actuated Models
4×1 Terminal
Arrangement
2
C
8
8
4
2
1
1
C
4
2
1
3×3 Terminal
Arrangement
8
C
2
1
C
4
4
■Precautions
Be sure to read the Safety precautions common to all DIP Switches for correct use.
3
A6R/A6RV
A6R/A6RV
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
4
Contact: www.omron.com/ecb
Cat. No. A212-E1-01
0812(0207)(O)