DATA SHEET SKY84632: 3A Slew-Rate Controlled Load Switch with Reverse Blocking Applications Description Smartphones, tablet PCs, and portable devices The SKY84632 SmartSwitch is a slew rate controlled P-channel MOSFET power switch designed for high side load switching applications. This switch operates with inputs ranging from 1.5 V to 5.5 V, making it ideal for 1.8 V, 3 V, and 5 V systems. It connects/disconnects up to 3 A continuous loads powered from the DC power rail with stringent off-state current targets and high load capacitances (up to 100 F) through enable control. The integrated low-impedance PMOSFET switch, together with typical 2.7 ms turn-on slew rate control, prevents large inrush current and excessive voltage drop on power rails. Features 1.5 V to 5.5 V input voltage range 3 A Maximum continuous current capability Typical RDS(ON) 38 m at VIN = 5.5 V 40 m at VIN = 4.5 V 76 m at VIN = 1.8 V 97 m at VIN = 1.5 V The SKY84632 has the reverse blocking feature that blocks unexpected reverse current from OUT to IN during the PMOSFET on and off states. The typical 9 A quiescent current makes it ideal for power saving applications. The exceptional low off-state current drain (maximum 1 A) facilitates compliance with standby power requirements. The switch enable control is active high with an internal pull-down resistor that eliminates the need for an external pull-down resistor. The SKY84632 also includes overtemperature protection and recovers automatically when the fault is removed. Reverse blocking (RB) Input hot plug capability Over-temperature protection Typical 2.7 ms rise time for slew rate/inrush control Low quiescent current (typical 9 A) Less than 1 A off supply current Enable control Logic CMOS IO meets JESD76 standard Active high with internal pull-down resistor Ultra small, low-profile WLCSP (6-bump, 0.5 mm pitch, 0.995 х 1.495 mm) package (MSL1, 260 °C per JEDEC-J-STD-020) The SKY84632 is available in a 6-bump, 0.995 х 1.495 mm, Wafer-Level Chip-Scale Package (WLCSP) with 0.5 mm pin pitch, and is rated over the –40 °C to +85 °C temperature range. A typical application circuit is shown in Figure 1. The pin configuration is shown in Figure 2. Signal pin assignments and functional pin descriptions are provided in Table 1. Skyworks Green™ products are compliant with all applicable legislation and are halogen-free. For additional information, refer to Skyworks Definition of Green™, document number SQ04-0074. VIN: 1.5 V to 5.5 V VOUT OUT IN CIN COUT SKY84632 1 μF to 22 μF ON OFF EN 0.1 μF to 100 μF GND tc1 Figure 1. SKY84632 Typical Application Circuit Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202090D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 30, 2013 1 DATA SHEET • SKY84632 3A SLEW-RATE CONTROLLED LOAD SWITCH WITH REVERSE BLOCKING OUT A1 A2 IN OUT B1 B2 IN GND C1 C2 EN tc2 Figure 2. SKY84632 Pinout – 6-Bump WLCSP (Top View) Table 1. SKY84632 Signal Descriptions Pin # Name A1, B1 OUT A2, B2 IN C1 GND C2 EN Description Load switch output. Put at least 0.1 F output capacitor between OUT and GND. Supply input. Put at least 1 F input capacitor between IN and GND. Ground. Enable input. Active high with internal pull-down resistor. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 2 July 30, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202090D DATA SHEET • SKY84632 3A SLEW-RATE CONTROLLED LOAD SWITCH WITH REVERSE BLOCKING Electrical and Mechanical Specifications The absolute maximum ratings of the SKY84632 are provided in Table 2. The recommended operating conditions are specified in Table 3, and electrical specifications are provided in Table 4. Typical performance characteristics of the SKY84632 are illustrated in Figures 5 through 22. Timing Diagrams Figure 3 shows the tR and tF of VOUT. Figure 4 illustrates the relationship between tD(ON) and tD(OFF). Table 2. SKY84632 Absolute Maximum Ratings (Note 1) Symbol Minimum Maximum Units IN to GND Parameter VIN –0.3 +6 V EN to GND VEN –0.3 VIN + 0.3 V OUT to GND VOUT –0.3 Maximum continuous DC output current (Note 2) ISW Maximum junction operating temperature Maximum soldering temperature (at leads, 10 sec) TJ Typical VIN + 0.3 V 3 –40 A +150 ºC TLEAD 300 ºC Thermal resistance, junction to ambient (Note 3) θJA 136 ºC/W Maximum power dissipation PD 0.9 W Note 1: Exposure to maximum rating conditions for extended periods may reduce device reliability. There is no damage to device with only one parameter set at the limit and all other parameters set at or below their nominal value. Exceeding any of the limits listed may result in permanent damage to the device. Note 2: Support IN high voltage pulse up to 7 V lasting 8 s. Note 3: Mounted on FR4 circuit board. CAUTION: Although this device is designed to be as robust as possible, Electrostatic Discharge (ESD) can damage this device. This device must be protected at all times from ESD. Static charges may easily produce potentials of several kilovolts on the human body or equipment, which can discharge without detection. Industry-standard ESD precautions should be used at all times. Table 3. SKY84632 Recommended Operating Conditions Parameter Input voltage Symbol Minimum Typical Maximum VIN 1.5 Enable threshold VENH 1.15 Disable threshold VENL 0.6 V Continuous switch output current ISW 3 A Operating ambient temperature range TA +85 °C –40 5.5 Units V V Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202090D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 30, 2013 3 DATA SHEET • SKY84632 3A SLEW-RATE CONTROLLED LOAD SWITCH WITH REVERSE BLOCKING Table 4. SKY84632 Electrical Specifications (1 of 2) (Note 1) (VIN = 1.5 V to 5.5 V, TA = –40 °C to 85 °C, Typical Values are at VIN = 4.5 V and TA = 25 °C, Unless Otherwise Noted) Parameter Symbol Test Condition Input voltage VIN Off supply current IQ(OFF) VEN = GND, VOUT = Open Off switch current ISD VEN = GND, VOUT = GND, TA = –40 °C to +85 °C Quiescent current IQ On-resistance Min Typical 1.5 Max 5.5 V 1 A 0.2 4 A 12 A VEN = High, IOUT = 0 A 9 VIN = 5.5 V, IOUT = 3 A 40 VIN = 5.5 V, IOUT = 2 A 39 VIN = 5.5 V, IOUT = 1 A, TA = 25°C 38 VIN = 4.5 V, IOUT = 3 A 42 VIN = 4.5 V, IOUT = 2 A 41 VIN = 4.5 V, IOUT = 1 A, TA = 25°C 40 VIN = 3.3 V, IOUT = 500 mA, TA = 25°C 47 VIN = 2.5 V, IOUT = 500 mA, TA = 25°C 56 VIN = 1.8 V, IOUT = 250 mA, TA = 25°C 76 VIN = 1.5 V, IOUT = 250 mA, TA = 25°C 97 53 m RDS(ON) En input logic high voltage En input logic low voltage VIH Units VIN = 1.5 V to 5.5 V 54 122 1.15 V VIN = 1.8 V to 5.5 V 0.55 VIN = 1.5 V to 1.8 V 0.5 VIL V 1 A 12 m En input leakage current IEN VEN = VIN or GND Pull-down resistance at EN bump REN_PD VEN = VIN = 1.5 V to 5.5 V, TA = –40 °C to +85 °C RB protection trip point VT_RB VOUT – VIN 45 mV RB protection release trip point VR_RB VIN – VOUT 25 mV 70 mV 6 9 Reverse Blocking (RB) RB hysteresis 2 ISD_OUT VEN = 0 V, VOUT = 5.5 V, VIN = GND (Note 2) RB release, device ON tRB_ON VOUT – VIN = 100 mV, EN = High 4 s RB release, device OFF tRB_OFF VOUT – VIN = 100 mV, EN = Low 2.5 s Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 4 A Reverse current at OUT when EN shuts down July 30, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202090D DATA SHEET • SKY84632 3A SLEW-RATE CONTROLLED LOAD SWITCH WITH REVERSE BLOCKING Table 4. SKY84632 Electrical Specifications (2 of 2) (Note 1) (VIN = 1.5 V to 5.5 V, TA = –40 °C to 85 °C, Typical Values are at VIN = 4.5 V and TA = 25 °C, Unless Otherwise Noted) Parameter Symbol Test Condition Min Typical Max Units Dynamic Characteristics Turn-on delay (Note 3) tD(ON) VOUT rise time (Note 3) tR Turn-on time (Note 4) tON Turn-on delay (Note 3) tD(ON) 1.7 VIN = 4.5 V, RL = 5 , CL = 100 F, TA = 25°C 2.7 1.8 VIN = 4.5 V, RL = 150 , CL = 100 F, TA = 25°C VOUT rise time (Note 3) tR Turn-on time (Note 4) tON Turn-off delay (Note 3) tD(OFF) 2 tF Turn-off time (Note 5) tOFF ms 3.8 3 VIN = 4.5 V, RL = 150 , CL = 100 F, TA = 25°C VOUT fall time (Note 3) ms 4.4 35 ms 38 Over-Temperature Protection Over-temperature shutdown threshold TSD Temperature increases Over-temperature shutdown hysteresis TSD_HYS 150 ºC 20 ºC Note 1: Performance is guaranteed only under the conditions listed in this Table. Note 2: This parameter’s performance is only guaranteed in a completely dark environment. Exposing the WLCSP device to direct sunlight causes the parameter to slightly exceed the maximum value. Note 3: Turn-on/turn-off delay, and rise/fall times are defined in Figures 3 and 4. Note 4: tON = tD(ON) + tR Note 5: tOFF = tD(OFF) + tF. tR tF 90% 90% VOUT 10% 10% tc4 Figure 3. Timing Diagram of tR/tF 50% 50% VEN 90% tD(OFF) VOUT 10% tD(ON) tc5 Figure 4. Timing Diagram of tD(ON)/tD(OFF) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202090D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 30, 2013 5 DATA SHEET • SKY84632 3A SLEW-RATE CONTROLLED LOAD SWITCH WITH REVERSE BLOCKING Typical Performance Characteristics 1.0 2.0 1.5 0.8 1.0 ISD (μA) ISD (μA) 0.5 0.0 -0.5 -1.0 0.6 0.4 25 °C 0.2 85 °C VIN = 5.5 V -1.5 −40 °C VIN = 1.5 V 0.0 -2.0 -40 -15 10 35 60 1.5 85 2.0 2.5 3.5 4.0 4.5 5.0 5.5 Input Voltage (V) Temperature (°C) Figure 6. Shutdown Current vs Input Voltage Figure 5. Shutdown Current vs Temperature 15 15 12 12 9 9 IQ (μA) IQ (μA) 3.0 6 VIN = 5.5 V 3 6 25 ºC 3 85 ºC VIN = 1.5 V −40 °C 0 0 -40 -15 10 35 60 1.5 85 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Input Voltage (V) Temperature (°C) Figure 8. Quiescent Current vs Input Voltage Figure 7. Quiescent Current vs Temperature 120 120 100 100 25 °C −40 °C RDS(ON) (mΩ) RDS(ON) (mΩ) 85 °C 80 60 40 80 60 40 VIN = 5.5 V, IOUT = 1000 mA 20 VIN = 3.3 V, IOUT = 500 mA 20 VIN = 1.8 V, IOUT = 250 mA VIN = 1.5 V, IOUT = 250 mA 0 0 -40 -15 10 35 Temperature (°C) Figure 9. RDS(ON) vs Temperature 60 85 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Input Voltage (V) Figure 10. RDS(ON) vs Input Voltage Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 6 July 30, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202090D 5.0 5.5 DATA SHEET • SKY84632 3A SLEW-RATE CONTROLLED LOAD SWITCH WITH REVERSE BLOCKING 1.2 1.2 VIN = 5.5 V 1.1 1.1 VIN = 1.5 V 1.0 VIH (V) VIH (V) 1.0 0.9 0.9 0.8 0.8 0.7 0.7 0.6 25 °C −40 °C 85 °C 0.6 -40 -15 10 35 60 1.5 85 2.0 2.5 Temperature (°C) 3.0 3.5 4.0 4.5 5.0 5.5 Input Voltage (V) Figure 11. EN Input Logic High Voltage vs Temperature Figure 12. EN Input Logic High Voltage vs Input Voltage 1.2 1.2 VIN = 5.5 V 1.1 1.1 VIN = 1.5 V 1.0 VIL (V) VIL (V) 1.0 0.9 0.9 0.8 0.8 0.7 0.7 0.6 0.6 25 °C - 40 °C 85 °C -40 -15 10 35 60 85 1.5 2.0 Temperature (°C) 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Input Voltage (V) Figure 13. EN Input Logic Low Voltage vs Temperature Figure 14. EN Input Logic Low Voltage vs Input Voltage 1.2 VIH & VIL (V) 1.1 EN 2 V/div 0 VOUT 2 V/div 0 1.0 0.9 0.8 VIH 0.7 IOUT 500 mA/div 0 VIL 0.6 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 Input Voltage (V) Figure 15. EN Input Logic High/Low Voltage vs Input Voltage Time (2 ms/div) Figure 16. Output Turn-On Time (VIN = 4.5 V, CIN = 10 F, COUT = 100 F, RL = 5 ) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202090D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 30, 2013 7 DATA SHEET • SKY84632 3A SLEW-RATE CONTROLLED LOAD SWITCH WITH REVERSE BLOCKING EN 2 V/div EN 2 V/div 0 VOUT 2 V/div 0 0 VOUT 2 V/div 0 IOUT 20 mA/div 0 IOUT 0 20 mA/div Time (2 ms/div) Time (10 ms/div) Figure 17. Output Turn-On Time (VIN = 4.5 V, CIN = 10 F, COUT = 100 F, RL = 150) Figure 18. Output Turn-Off Time (VIN = 4.5 V, CIN = 10 F, COUT = 100 F, RL = 150) 4.0 40 35 tD(ON) & tD(OFF) (ms) tD(ON) & tD(OFF) (ms) 3.2 2.4 1.6 0.8 30 25 20 15 10 tR tF tD(ON) 5 tD(OFF) 0.0 0 -40 -15 10 35 60 85 -40 Temperature (°C) -15 10 35 60 85 Temperature (°C) Figure 19. Turn On/Off Delay Time vs Temperature Figure 20. Turn On Rising & Trun-Off Falling Time vs Temperature VIN 2 V/div VIN 2 V/div 0 VOUT 0 2 V/div VOUT 2 V/div 0 0 IOUT 1 A/div 0 IOUT 0 20 mA/div Time (20 μs/div) Figure 21. RB Response Time During On (VIN = VEN = 3.6 V, VOUT = 5.5 V, CIN = 10 F, COUT = 100 F) Time (40 μs/div) Figure 22. RB Response Time During Off (VIN = VEN = 0 V, VOUT = 5.5 V, CIN = 10 F, COUT = 100 F) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 8 July 30, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202090D DATA SHEET • SKY84632 3A SLEW-RATE CONTROLLED LOAD SWITCH WITH REVERSE BLOCKING Reverse Blocking IN OUT EN Control Logic Turn-On Slew Rate Controlled Driver R EN Over-Temp Protection GND tc3 Figure 23. SKY84632 Functional Block Diagram Functional Description ILOAD = Load current in mA The SKY84632 is an integrated low-RDS(ON) P-channel load switch with enable activity and reverse blocking. A wide input voltage range from 1.5 V to 5.5 V allows the SKY84632 to be compatible with GPIO/CMOS input. Logic high at the EN bump activates the device. The reverse blocking feature prevents current flow from output to input at the load switch for both on/off states. The SKY84632 typically consumes 9 A when operating. When switched off, the device draws less than 1 A. The SKY84632 also integrates over-temperature protection for high ambient temperature or junction temperature caused by excess current. A functional block diagram of the SKY84632 is provided in Figure 23. For example, the SKY84632 has a 2.7 ms of slew rate capability under 4.5 V at 100 F of COUT and no load, so inrush current can be minimized under 200 mA as Figure 24 shows. EN 2 V/div 0 VOUT 2 V/div 0 IIN 0 100 mA/div Time (2 ms/div) Application Information Slew Rate and Inrush Current Control To avoid large inrush current when the load switch is turned on, the slew rate controller feature allows the output voltage to rise slowly. The inrush current is dependent on slew rate control capability and output capacitance as expressed by: IINRUSH = ILOAD + COUT × (VIN - VOUT) tR Figure 24: Inrush Current Waveform (VIN = 5.0 V, CIN = 10 F, COUT = 100 F, No Load) High inrush current makes the input voltage drop. The voltage drop value depends on the inrush current, power line equivalent parasitic resistance, and input capacitor. A large input voltage drop can cause system application problems. Reverse Blocking Where: COUT = Output capacitance in F VIN = Input voltage in V tR: = Rise time at VOUT in ms The reverse blocking feature protects the input source against current flow from output to input regardless of whether the load switch is on or off. VINITIAL = Initial voltage at COUT in V Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202090D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 30, 2013 9 DATA SHEET • SKY84632 3A SLEW-RATE CONTROLLED LOAD SWITCH WITH REVERSE BLOCKING Thermal Protection Layout Guidance The SKY84632 includes thermal protection that disables the load switch when the die temperature reaches 140 °C. It automatically restarts when the temperature drops by 15 °C or more. For best performance of the SKY84632, the following guidelines should be followed when designing the PCB layout: When an overload or output short to GND occurs, the power dissipation on device increases rapidly, triggering the thermal protection to prevent damage to the part. Connect the input/output capacitor to GND as close as possible to decrease the effect of parasitic inductance and to get a better noise filtering effect. Make the power trace as short and wide as possible, including the input/output power lines Input Capacitor Select a low Equivalent Series Resistance (ESR) ceramic capacitor with a value of at least 1 F as the input capacitor. The input capacitor should be placed as close to the IN and GND bumps as possible to minimize the stray resistance from the device to the input power source. Evaluation Board Description The SKY84632 Evaluation Board is used to test the performance of the SKY84632. An Evaluation Board schematic diagram is provided in Figure 25. The PCB layout is shown in Figures 26 and 27. Component values for the SKY84632 Evaluation Board are listed in Table 5. Output Capacitor Select a low ESR ceramic capacitor with a value of at least 0.1 F as the output capacitor. The output capacitor should be placed as close to the OUT and GND bumps as possible to minimize the parasitic board inductance against forcing VOUT below GND when the switch is on. Package Information Typical case markings for the 6-bump WLCSP are shown in Figure 28. Package dimensions are shown in Figure 29, and the tape and reel dimensions are provided in Figure 30. IN OUT VIN: 1.5 V to 5.5 V VOUT OUT IN C1 C3 SKY84632 10 F EN IN C2(open) 100 F GND GND tc6 Figure 25. SKY84632 Evaluation Board Schematic Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 10 July 30, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202090D DATA SHEET • SKY84632 3A SLEW-RATE CONTROLLED LOAD SWITCH WITH REVERSE BLOCKING Figure 26. SKY84632 Evaluation Board PCB Top Side Figure 27. SKY84632 Evaluation Board PCB Bottom Side Table 5. SKY84632 Evaluation Board Bill of Materials Component Part Number Description Manufacturer U1 SKY84632 3A Slew-Rate Controlled Load Switch with Reverse Blocking Skyworks C1 GRM188R60J106ME47D Cap Ceramic, 10 F, 0603 X5R, 6.3 V, 20% Murata C2 GRM188R61E104KA01D Cap Ceramic, 0.1 F, 0603 X5R, 25 V, 10% Murata C3 GRM31CR60J107ME39L Cap Ceramic, 100 F, 1206 X5R, 6.3 V, 20% Murata Pin 1 Indicator Skyworks Part # Wafer Batch Number Figure 28. Typical Case Markings (Top View) Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202090D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 30, 2013 11 0.695 + 0.085/–0.084 0.995 0.450 ± 0.06 0.150–0.200 Ref. 0.250 ± 0.005 0.250 ± 0.005 DATA SHEET • SKY84632 3A SLEW-RATE CONTROLLED LOAD SWITCH WITH REVERSE BLOCKING 6X ø0.315 ± 0.047 0.150–0.200 Ref. A Bump A1 Indicator (Min. 0.100 Diam.) A 0 B 0.500 ± 0.005 C 1.495 B C 1 0.500 ± 0.005 2 2 0.247 Ref. 1 0.245 + 0.025/–0.024 0.247 Ref. Bump Side Down Side View Bump Side Up All measurements are in millimeters S3486 Figure 29. SKY84632 6-Bump WLCSP Package Dimensions 4.00 ± 0.10 2.00 ± 0.05 0.254 ± 0.02 ø1.50 ± 0.10 4.00 ± 0.10 5° Max. 1.68 ± 0.05 (Bo) Pin #1 Indicator 0.83 ± 0.05 (Ko) 8.00 + 0.30/–0.10 3.50 ± 0.05 1.75 ± 0.10 ø0.50 ± 0.05 1.18 ± 0.05 (Ao) 5.4± 0.1 0.062± 0.013 Polyester Film Notes: Cross-Section of Cover Tape 1. Carrier tape: Black conductive polycarbonate 2. Cover tape: Transparent conductive material 3. 10 sprocket hole pitch cumulative tolerance: ± 0.20 mm 4. Pocket position relative to sprocket hole measured as true position of pocket 5. All dimensions are in millimeters Y0019 Figure 30. SKY84632 Tape and Reel Dimensions Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 12 July 30, 2013 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • 202090D DATA SHEET • SKY84632 3A SLEW-RATE CONTROLLED LOAD SWITCH WITH REVERSE BLOCKING Ordering Information Model Name SKY84632 Load Switch with Reverse Blocking Manufacturing Part Number (Note 1) Evaluation Board Part Number SKY84632-11-001 SKY84632-11-001-EVB Note 1: Sample stock is generally held on part numbers listed in BOLD. Copyright © 2013 Skyworks Solutions, Inc. All Rights Reserved. Information in this document is provided in connection with Skyworks Solutions, Inc. (“Skyworks”) products or services. These materials, including the information contained herein, are provided by Skyworks as a service to its customers and may be used for informational purposes only by the customer. Skyworks assumes no responsibility for errors or omissions in these materials or the information contained herein. Skyworks may change its documentation, products, services, specifications or product descriptions at any time, without notice. Skyworks makes no commitment to update the materials or information and shall have no responsibility whatsoever for conflicts, incompatibilities, or other difficulties arising from any future changes. No license, whether express, implied, by estoppel or otherwise, is granted to any intellectual property rights by this document. Skyworks assumes no liability for any materials, products or information provided hereunder, including the sale, distribution, reproduction or use of Skyworks products, information or materials, except as may be provided in Skyworks Terms and Conditions of Sale. THE MATERIALS, PRODUCTS AND INFORMATION ARE PROVIDED “AS IS” WITHOUT WARRANTY OF ANY KIND, WHETHER EXPRESS, IMPLIED, STATUTORY, OR OTHERWISE, INCLUDING FITNESS FOR A PARTICULAR PURPOSE OR USE, MERCHANTABILITY, PERFORMANCE, QUALITY OR NON-INFRINGEMENT OF ANY INTELLECTUAL PROPERTY RIGHT; ALL SUCH WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED. SKYWORKS DOES NOT WARRANT THE ACCURACY OR COMPLETENESS OF THE INFORMATION, TEXT, GRAPHICS OR OTHER ITEMS CONTAINED WITHIN THESE MATERIALS. SKYWORKS SHALL NOT BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO ANY SPECIAL, INDIRECT, INCIDENTAL, STATUTORY, OR CONSEQUENTIAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR LOST PROFITS THAT MAY RESULT FROM THE USE OF THE MATERIALS OR INFORMATION, WHETHER OR NOT THE RECIPIENT OF MATERIALS HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Skyworks products are not intended for use in medical, lifesaving or life-sustaining applications, or other equipment in which the failure of the Skyworks products could lead to personal injury, death, physical or environmental damage. Skyworks customers using or selling Skyworks products for use in such applications do so at their own risk and agree to fully indemnify Skyworks for any damages resulting from such improper use or sale. Customers are responsible for their products and applications using Skyworks products, which may deviate from published specifications as a result of design defects, errors, or operation of products outside of published parameters or design specifications. Customers should include design and operating safeguards to minimize these and other risks. Skyworks assumes no liability for applications assistance, customer product design, or damage to any equipment resulting from the use of Skyworks products outside of stated published specifications or parameters. Skyworks, the Skyworks symbol, and “Breakthrough Simplicity” are trademarks or registered trademarks of Skyworks Solutions, Inc., in the United States and other countries. Third-party brands and names are for identification purposes only, and are the property of their respective owners. Additional information, including relevant terms and conditions, posted at www.skyworksinc.com, are incorporated by reference. Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • [email protected] • www.skyworksinc.com 202090D • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice • July 30, 2013 13