1 3 2 4 REVISIONS REV DESCRIPTION DATE APPROVED B Changed Description QBI-00 to QBI-00/02 PER ECO 13-17058 09/19/13 DS C MOVED OUTPUT TERMINAL BLOCK AND ADDED WEIGHT PER ECO 13-17318 103113 L. PITZELE MOVED OUTPUT TERMINAL BLOCK TO MATCH UPDATED PCB; UPDATED DRAWING TITLE PER ECO 13-17526 122013 2.39 [60,6] A 0.28 [7,1] 0.200 1.800 [45,72] D [5,08] A L. PITZELE 1.54 [39,0] 1.100 [27,94] B 0.252 0.552 [14,02] 0.552 [14,02] 0.200 [5,08] 0.100 [2,54] [6,40] 1.600 [40,64] C 1 SCALE 0.750 0.062 [1,57] 0.54 [13,6] NOTES: 1. CONSULT DATASHEET OF THE UNIT THAT THE INTERFACE BOARD IS / WILL BE MOUNTED TO FOR I/O DEFINITIONS, MOUNTING DIMENSIONS AND OPERATING PARAMETERS. 2. ALL DIMENSIONS IN INCHES (MM) TOLERANCES: X.XX ± .02 IN. (X.X ± X.XXX ± .010 IN. (X.XX ± 3. TERMINALS 1, 3, 4, 8: M4 SCREW POST, MAX TORQUE 6 IN-LB (.7 Nm). 4. TERMINAL BLOCKS: WIRE SIZE 16-30 AWG, 13.5A MAX CURRENT PER TERMINAL, MAX TORQUE 4 IN-LB (.5 Nm) 5. FITS BOTH NORMAL AND FLANGED QUARTER BRICKS 6. ADAPTOR WEIGHT: 1.02 oz (29 g) B 3 0.08 [1,9] 1.04 [26,5] TOLERANCES: .5mm) .25mm) Unless otherwise specified: All dimensions in inches .X +/- .025 THIRD ANGLE PROJECTION .XX +/- .010 .XXX +/- .005 Angles +/- 1° SOURCE: PRO/E 020-0000251 155 Swanson Road Boxborough, MA 01719 QBI-00 CONV. INTERFACE ASSY. THROUGH HOLE MOUNTING THIS DRAWING IS THE PROPERTY OF SYNQOR INC. It is not to be reproduced or copied, in whole or in part, or used for furnishing information to others, or for any purpose detrimental to the interests of SynQor. The information shown herein may be protected by patents owned or controlled by SynQor, 2 SIZE A DATE 122013 SCALE: 1.000 3 DWG. NO. DRAWN: LDP 020-0000251 SHEET 1 of 1 CHECK: 4 C REV D