Isolated H-Bridge Transformers for MAX13256 Stamp

Isolated H-Bridge Transformers for MAX13256
◆Outline
・RoHS compliance
・MSL level1
・Operating temperature range : -40℃~+85℃ (Including coil’s self temperature rise)
・Packing : Tape & Reel, 350pcs par reel.
◆Applications
・Isolated H-Bridge Transformer for MAX 13256 reference. Power Meters, Isolated Fieldbus Interfaces,
24V PLC Supply Isolation, Medical Equipment, Motor Controls.
◆ Sumida Type name : CPFC1209
◆ Dimensions (mm)
Stamp
13.5 Max.
10
Stamp·Date Code
6
2.54±0.3
10
6
*1
1
5
10.0 Max.
05220-T009 ~T012
Stamp
(*1)
Inductance
(1-5)
10KHz,0.1Vrm
s
009
DCR
(1-5)
DCR
(6-9) / (7-10)
750mΩ Max.
750mΩ Max.
Turns ratio
Hi pot (1,5) (1-5) : (6-9) : (7-10) (6,7,9,10)
2:1:1
750 µH Min.
05220-T010
010
05220-T011
011
05220-T012
(*2)
05220-T013
*2 (05220-T013 Only)
* Dots indicate the polarity.
◆ Electrical characteristic
05220-T009
5
Coil Connection (Bottom View)
11.0
18.0
Part Number
1
SQ0.5
1.5
2.54
◆ Recommend PCB layout (mm)
sumida
T007
750mΩ Max.
750mΩ Max.
1:1:1
300 µH Min.
750mΩ Max.
650mΩ Max.
3:2:2
012
300 µH Min.
1.2 Ω Max.
1.2 Ω Max.
1:1:1
013
750 µH Min.
700mΩ Max.
(6 - 10)
250mΩ Max.
(1- 5) : (6-10)
3:1
2000Vrms
1 Sec
50/60Hz,
1mA
ET
(1-5)
60.0V. μS
Min.
35.0V. μS
Min.
5000Vrms
1 Sec
50/60Hz,
60.0V. μS
Min.
1mA
Note: This datasheet might be slightly modified without notice in order to improve the quality and reliability of the product. Please
contact an appropriate our sales in your regions for checking final spec before you place an order
Rev. .1.0(2014.04)