HG4138L

HG4138L
Miniature PCB / QC Heavy Duty Power Relay
FEATURES
Improved HG4138 relay by magnetic arc blowout
Up to 45A switching capacity
PCB + QC termination
TYPICAL APPLICATIONS
Power supply devices
Industrial control
Medical equipment
CONTACT RATING
45A, 240VAC
45A, 28VDC
Resistive
1 Form C (1Z)
NO
NC
30A, 240VAC
15A, 240VAC
30A, 28VDC
15A, 28VDC
1 Form B (1D)
1 Form A (1H)
Form
15A, 240VAC
15A, 28VDC
UL /CSA RATING
Voltage
1 Form A (1H)
1 Form B (1D)
240VAC
240VAC
28VDC
240VAC
120VAC
240VAC
120VAC
120VAC
277VAC
125 - 250VAC
45A
45A
30A
3HP
1.5HP
120A/45A
147A/33A
TV8
15A
700VA
20A
20A
15A
0.75HP
0.375HP
Load Type
General Purpose
Resistive
Motor
LRA /FLA
Tungsten
Ballast
Pilot Lamp
1 Form C (1Z)
NO
NC
15A
30A
15A
30A
30A
15A
0.75HP
2HP
1.5HP
0.375HP
45A/15A
75A/30A
30A/10.5A
TV4
4.5A
TV8
15A
TV4
4.5A
CONTACT DATA
AgSnOInO
50 m Ω, max. at 0.1A, 6VDC
Material
Initial Contact Resistance
Service Life
Mechanical
10 7 ops.
Electrical
1.5 x 10 4 ops.
COIL DATA
Coil Voltage
Code
Nominal Voltage
(VDC)
Resistance
(Ω) ±10%
Must Operate
Voltage max.
(VDC)
Must Release
Voltage min.
(VDC)
005
006
009
012
024
048
110
5
6
9
12
24
48
110
27
40
97
155
660
2560
10330
3.75
4.50
6.75
9.00
18.00
36.00
82.50
0.5
0.6
0.9
1.2
2.4
4.8
11.0
CHARACTERISTICS
Operate Time
Release Time
Insulation Resistance
Dielectric Strength
Shock Resistance
Vibration Resistance
Power Consumption
Ambient Temperature
Weight
15 ms. typical
10 ms. typical
1000 M Ω, at 500VDC, 50%RH
1500 Vrms, 1 min. between open contacts
1500 Vrms, 1 min. between coil and contacts
10 g, 11ms, functional; 100 g, destructive
DA 1.5mm, 10 - 55 Hz,
1W, approx.
-55ºC to 85ºC operating
32 g, approx.
HG4138L RoHS May05
1/2
HG4138L
ORDERING DESIGNATION
Example:
HG4138L /
012 -
1Z
0
1
S
F
-P
Model
Coil Voltage Code
Contact Form
1H: 1 Form A; 1D: 1 Form B; 1Z: 1 Form C
Mounting Version
0: PCB
Version
1: Sealed; 2: Dust Cover
Contact Material
S: AgSnOInO
Thermal Class
Nil: UL Class B; F: UL Class F
P: RoHS Compliance (lead-free)
OVERALL DIMENSIONS, MOUNTING HOLES AND WIRING DIAGRAMS (mm)
Overall Dimensions
Mounting Holes (Bottom View)
3 - 6.4 QC
Wiring Diagrams (Top View)
NOTES
1.
2.
3.
4.
All parameters, unless otherwise specified, are measured at ambient temperature 23ºC.
In mounting holes drawing the * hole is not needed for 1 Form A, the ** hole is not needed for 1 Form B.
For optimum electrical life, please remove the tape seal of the sealed version after cleaning process.
Specifications subject to change without prior notice.
Willow Technologies Limited
Shawlands Court, Newchapel Road,
Lingfield, Surrey, England. RH7 6BL
Tel: +44 (0) 1342 835234
Fax: +44 (0) 1342 834306
email: [email protected]
HG4138L RoHS May05