ER134 Series

TELEDYNE RELAYS
CENTIGRID®
ESTABLISHED RELIABILITY RELAY
SERIES
134
SENSITIVE DPDT
SERIES
DESIGNATION
RELAY TYPE
134
DPDT basic relay
134D
DPDT relay with internal diode for coil transient suppression
134DD
DPDT relay with internal diodes for coil transient suppression and
polarity reversal protection
INTERNAL CONSTRUCTION
DESCRIPTION
The sensitive Centigrid® relay retains the same features as the standard Centigrid® with only
a minimal increase in profile height (.375 in.). It provides a .100 in. grid spaced terminal
pattern which precludes the need for spreader pads and, together with the low profile, is
ideal for applications where high packaging density is important.
UPPER
STATIONARY
CONTACT
UNI-FRAME
The following unique construction features and manufacturing techniques provide excellent
resistance to environmental extremes and overall high reliability:
ARMATURE
•
•
•
•
•
LOWER
STATIONARY
CONTACT
MOVING
CONTACT
All welded construction.
Unique uni-frame design providing high magnetic efficiency and mechanical rigidity.
High force/mass ratios for resistance to shock and vibration.
Advanced cleaning techniques provide maximum assurance of internal cleanliness.
Precious metal alloy contact material with gold plating assures excellent high current
and dry circuit switching capabilities.
The 134D and 134DD Series utilizes internal discrete silicon diodes for coil suppression and
polarity reversal protection.
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
Temperature
(Ambient)
-65°C to + 125°C
Vibration
30 g’s to 3000 Hz (Note 1)
Shock
75 g’s for 6 msec. (Note 1)
half-sine
Acceleration
50 g’s (Note 1)
Enclosure
All welded, hermetically sealed
Weight
0.15 oz (4.3 gms.) max.
The sensitive Centigrid® relay features exceptionally high coil resistance thus providing for
extremely low operating power (200 mw typical). The advantages of reduced heat dissipation
and power supply demands are obvious.
By virtue of its inherently low intercontact capacitance and contact circuit losses, the 134
relay has shown itself to be an excellent ultraminiature RF switch for frequency ranges well
into the UHF spectrum. A typical RF application for the Centigrid® relay is in hand held radio
transceivers, wherein the combined features of good RF performance, small size, low coil
power dissipation and high reliability make it a preferred method of Transmit-Receive
switching (see Figure 1).
29
SERIES 134
GENERAL ELECTRICAL SPECIFICATIONS
(-65°C to +125°C unless otherwise noted) (Notes 2 & 7)
Contact Arrangement
Rated Duty
Contact Resistance
Contact Load Rating (DC)
(See Fig. 2 for other DC
resistive voltage/current ratings)
2 Form C (DPDT)
Continuous
0.1 ohms max. before life; 0.2 ohms max. after life at 1A/28VDC, (measured 1/8” from header)
Resistive:
1 Amp/28VDC
Inductive:
200 mA/28VDC (320 mH)
Lamp:
100 mA/28VDC
Low Level:
10 to 50 µA/10 to 50 mV
Resistive:
250 mA/115VAC, 60 and 400Hz (Case not grounded)
100 mA/115VAC, 60 and 400Hz (Case grounded)
10,000,000 cycles (typical) at low level
01,000,000 cycles (typical) at 0.5A/28VDC resistive
00,100,000 cycles min. at all other loads specified above
2A/28VDC Resistive (100 cycles min.)
Contact factory
200 milliwatts typical at nominal rated voltage @ 25°C
4.0 msec max. at nominal rated coil voltage
134 Series: 2.0 msec max.
134D, 134DD Series: 7.5 msec max.
1.5 msec max.
0.4 pf typical
10,000 megohms min. between mutually isolated terminals
Atmospheric pressure: 500 VRMS/60 Hz
70,000 ft.: 125 VRMS/60Hz
100 VDC min.
1.0 VDC max.
Contact Load Ratings (AC)
Contact Life Ratings
Contact Overload Rating
Contact Carry Rating
Coil Operating Power
Operate Time
Release Time
Contact Bounce
lntercontact Capacitance
Insulation Resistance
Dielectric Strength
Diode P.I.V. (134D, 134DD)
Negative Coil Transient (134D,
DETAILED ELECTRICAL SPECIFICATIONS
(-65°C to +125°C unless otherwise noted) (Note 7)
BASE PART
NUMBERS
(See Note 9 for full P/N Example
Coil Voltage (VDC)
➧
134-6
134D-6
134DD-6
134-9
134D-9
134DD-9
134-12
134D-12
134DD-12
134-18
134D-18
134DD-18
134-26
134D-26
134DD-26
5.0
7.5
100
64
56.8
78.1
3.5
3.7
0.12
2.5
0.7
2.6
6.0
10.0
200
125
36.3
48.9
4.5
4.8
0.18
3.2
0.8
3.0
9.0
15.0
400
400
18.1
23.6
6.8
8.0
0.35
4.9
0.9
4.5
12.0
20.0
800
800
12.5
16.0
9.0
11.0
0.41
6.5
1.0
5.8
18.0
30.0
1600
1600
9.6
12.2
13.5
14.5
0.59
10.0
1.1
9.0
26.5
40.0
3200
3200
7.2
9.0
18.0
19.0
0.89
13.0
1.3
13.0
Nom.
Max.
134, 134D
134DD (Note 3)
Coil Resistance
(Ohms ± 10% @ 25°C)
Coil Current (mADC @ 25°C)
(134DD Series)
Min.
Max.
Pick-up Voltage (VDC, Max.)
134, 134D
134DD
Drop-out Voltage (VDC)
Min.
Max.
Min.
Max.
134 &134D
134DD
PERFORMANCE CURVES
(NOTE 2)
134-5
134D-5
134DD-5
TYPICAL RF PERFORMANCE
0
INSE
RTIO
N
.1
.2
TYPICAL DC CONTACT RATING (RESISTIVE)
LOSS
300
LOAD VOLTAGE (VDC)
.3
10
1.92
WR)
SS (VS
20
N LO
RETUR
30
40
ATION
ISOL
50
SS
ACRO
TION
ISOLA
60
1.22
1.07
ACTS
CONT
1.02
OLES
1.01
SS P
ACRO
VSWR
dB
.4
200
150
100
50
1.00
70
250
1.00
.01
0.5
.1
.5
1.0
0
0.1
0.2
0.3
0.4
0.5
0.6
FREQUENCY (GHz)
LOAD CURRENT (AMPS DC)
FIGURE 1
FIGURE 2
30
0.7
0.8
0.9
1.0
SERIES 134
OUTLINE DIMENSIONS
SCHEMATIC DIAGRAMS
TERMINAL LOCATIONS
CASE DETAIL
(Viewed from Terminals. Numbers for Reference only)
.375 (9.53)
SQ. MAX.
.031 ± .003
(.79 ± .08)
.335 (8.51)
SQ. MAX.
.035 ± .010
(.89 ± .25)
.375 (9.53) MAX.
134
WIRE LEAD .750 (19.05) MIN.
PIN: .187 (1.75) ± .010 (.25)
(See Note 5)
.100 ± .010
(2.54 ± .25)
TYP
+.002 (.05)
.017 (.43) –.001 (.03) DIA.
DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS)
134D
SPACER PAD
NOTES:
Relays can be supplied with a spacer pad attached to the
relay header. The pad permits the relay to be spaced away
from the mounting surface facilitating solder joint inspection.
To order add M4 to the part number (e.g. ER134M4-26).
1. Material: Polyester film.
2. Increase contact resistance
by 0.01 ohm.
134DD
.400 MAX
(10.16)
SCHEMATICS ARE VIEWED FROM TERMINALS
NOTES:
1.
2.
3.
4.
5.
Relay contacts will exhibit no chatter in excess of 10 µsec or transfer in excess of 1 µsec.
“Typical” characteristics are based on available data and are best estimates. No on-going verification tests are performed.
For reference only. Coil resistance not directly measurable at relays terminals due to internal series semiconductor. 134DD only.
Screened HI-REL versions available. Contact factory.
Unless otherwise specified, relays will be supplied as follows: Length will be standard 0.75” (19.05) minimum and will be either gold plated
or solder coated. Contact your local representative for ordering information.
6. The slash and characters appearing after the slash are not marked on the relay.
7. Unless otherwise specified, parameters are initial values.
8.
RELIABILITY LEVEL
FAILURE RATE %/10,000 CYCLES
A
1.5
B
0.75
9.
Teledyne Part Numbering System for Established Reliability Relays (See T2R® Program Introduction)
EXAMPLE:
ER 134 D Z M4 – 26
A / SQ
Established
Reliability Designator
Termination Variant
Q = Solder Coated Leads (Notes 5 and 6)
S = .187” Leads (Notes 5 and 6)
Relay Series
Reliability and Screening Level (Note 8)
D = Diode Suppression
DD = Diode Suppression and Polarity Protection
Coil Voltage
Mounting Variant
Ground Pin (See page 112)
M4 = Spacer Pad
M4 = 194-3 Spacer Pad
©1996
TELEDYNE RELAYS
31
12525 Daphne Avenue
Hawthorne, California 90250