MK6

Meder Electronic
MK6 Series
Reed Sensors for
PCB Mounting
DESCRIPTION
MK6 sensors are magnetically operated Reed
proximity switches for direct PCB mounting. The
sensor should be mounted on a fixed surface with
the actuating magnet on the moving surface.
Introduction or removal of the magnetic field
determines the closing and opening of the Reed
Switch. (2.54 mm PCB pin spacing, available with
different distances)
FEATURES
• Form A, B, C and E (Latching) available
• High power switches available
• Various case sizes available
• Five operate sensitivities available
ORDER INFORMATION
APPLICATIONS
• Telecommunications
Telephone hook switch, keyboard applications
• Domestic appliances
Door switch for washing machines, dishwashers,
microwave ovens, baking ovens, refrigerators
• Limit switch for low-power signals
Garage door controls, lever hoists, conveyors
• Lifts / elevators
Position indicators
MAGNETIC SENSITIVITY
SERIES
PACKAGING
SIZE
MAGNETIC
SENSITIVITY
SENSITIVITY
CLASS
PULL IN
AT RANGE
MK6 -
X -
X
A
5 - 10
4
B, C, D, E
B
10 - 15
5
B, C
C, H
15 - 20
6
A, B, C, D, E
D, I
20 - 25
7
A, B, C, D, E
E, K
25 - 30
8 (Form A)
A, B, C, D, E
8 (Form C)
H, I, K
OPTIONS
SERIES
CONTACT
FORM
MK6 - 10 -
X*
Part Number Example
MK6 - 4 - C
4 is the packaging size
C is the magnetic sensitivity
B
Part Number Example
E
MK6 - 10 - E
OPTIONS
E selects the latching option
* See footnote on following page.
www.willow.co.uk
Tel. +44 (0) 1342 835234
Fax. +44 (0) 1342 834306
MK6 Series
Meder Electronic
Reed Sensors for
PCB Mounting
DIMENSIONS
All dimensions in mm [inches]
* MK6-10-E is a magnetic latching sensor which is opened or closed by a passing magnet and remains in that state until a magnet
of opposite polarity or direction passes by again. The E refers to a latching sensor and does not represent the magnetic
sensitivity.
MK6-10-B is a normally closed sensor. The B refers to a latching sensor and does not represent the magnetic sensitivity.
www.willow.co.uk
Tel. +44 (0) 1342 835234
Fax. +44 (0) 1342 834306
Meder Electronic
MK6 Series
Reed Sensors for
PCB Mounting
CONTACT DATA
All data at 20 0 C
Switch Model -->
Contact Form -->
Packaging styles -->
Contact Ratings
Conditions
Contact 71
Form A, B, E
6, 7, 8, 10
Min.
Typ.
Max.
Contact 80
Form A
4
Min.
Typ.
Max.
Units
Contact Rating
Any DC combination of V & A
not to exceed their individual
max.'s
10
10
W
Switching Voltage
DC or peak AC
200
170
V
Switching Current
DC or peak AC
0.5
0.5
A
Carry Current
DC or peak AC
1.25
0.5
A
Static Contact Resistance
w/ 0.5V & 10mA
150
200
mΩ
Dynamic Contact Resistance
Measured w/ 0.5V & 50mA
1.5 ms after closure
200
250
mΩ
Insulation Resistance across
Contacts
100 Volts applied
1010 *
109
Ω
Breakdown Voltage
Voltage applied for 60 sec.
min.
225 *
210
VDC
Operate Time, incl. Bounce
Measured w/ 100% overdrive
0.5
0.6
ms
Reset Time
Measured w/ no coil
suppression
0.1
0.1
ms
Capacitance
@ 10kHz across contact
0.2
0.2
pF
Contact Operation **
Must Operate Condition
Steady state field
10
30
10
30
AT
Must Reset Condition
Steady state field
4
27
4
27
AT
g
Environmental Data
Shock Resistance
1/2 sine wave duration 11ms
50
50
Vibration Resistance
From 10 - 2000 Hz
20
20
0
g
Ambient Temperature
10 C/ minute max. allowable
-20
85
-20
85
0
Storage Temperature
10 0 C/ minute max. allowable
-35
85
-35
85
0
Soldering Temperature
5 sec. dwell
260
0
260
C
C
C
Please note: The indicated electrical data are maximum values and can vary downwards when using a more sensitive switch.
* Insulation resistance of 1012 and breakdown voltage of 480 VDC is available.
** These ranges refer to the uncut / unmodified Reed Switches described in our Reed Switch section. Consult factory if more
detail is required.
www.willow.co.uk
Tel. +44 (0) 1342 835234
Fax. +44 (0) 1342 834306
MK6 Series
Meder Electronic
Reed Sensors for
PCB Mounting
CONTACT DATA
All data 20 0C
Switch Model -->
Contact Form -->
Packaging styles -->
Contact Ratings
Conditions
Contact 81 *
Form A
6, 7, 8
Min.
Typ.
Max.
Contact 87
Form A
5
Min.
Typ.
Max.
Contact 90
Form C
8
Min.
Typ.
Max.
Units
Contact Rating
Any DC combination of V & A
not to exceed their individual
max.'s
5
10
3
W
Switching Voltage
DC or peak AC
90
200
175
V
Switching Current
DC or peak AC
0.5
0.5
0.25
A
Carry Current
DC or peak AC
1.0
0.5
1.2
A
Static Contact Resistance
w/ 0.5V & 10mA
200
150
150
mΩ
Dynamic Contact Resistance
Measured w/ 0.5V & 50mA
1.5 ms after closure
200
200
250
mΩ
Insulation Resistance across
Contacts
100 Volts applied
10 9
10 9
10 9
Ω
Breakdown Voltage across
Contacts
Voltage applied for 60 sec.
min.
100
230
200
VDC
Operate Time, incl. Bounce
Measured w/ 100% overdrive
0.5
0.6
0.7
ms
Reset Time
Measured w/ no coil
suppression
0.1
0.1
1.5
ms
Capacitance
@ 10kHz across contact
0.2
0.2
1.0
pF
Contact Operation **
Must Operate Condition
Steady state field
5
10
10
20
15
30
AT
Must Reset Condition
Steady state field
2
9
4
18
6
27
AT
Environmental Data
Shock Resistance
1/2 sine wave duration 11ms
30
50
50
g
Vibration Resistance
From 10 - 2000 Hz
10
20
20
g
Ambient Temperature
10 0C/ minute max. allowable
-20
85
-20
85
-20
85
0
Storage Temperature
10 0C/ minute max. allowable
-35
85
-35
85
-35
85
0
Soldering Temperature
5 sec. dwell
260
0
260
260
Please note: The indicated electrical data are maximum values and can vary downwards when using a more sensitive switch.
* Switch model 81 is used for sensitivity range A only.
** These ranges refer to the uncut / unmodified Reed Switches described in our Reed Switch section. Consult factory if more detail is required.
www.willow.co.uk
Tel. +44 (0) 1342 835234
Fax. +44 (0) 1342 834306
C
C
C