DX2, DX3 & DX4 series industrial plug-in relay Contacts Contact number & arrangement Contact material * * * * Industry standard footprint, now with terminal blades with no holes for better mounting in sockets. * RoHS Compliant Integral LED (Red for AC, Green for DC coils). Locking Test Lever with press feature. (Blue for DC, Red for AC coils) Welded (not soldered) internal electrical connections for greater reliability. E325835 DPDT (2 C/O), 3PDT (3C/O), 4PDT (4 C/O) Ag alloy Max. switching voltage AC/DC 277VAC, 30VDC Min. breaking capacity W 0.3W Rated load (resistive - cos φ=1) AC1 DPDT: 10A/240VAC, 3PDT: 7A/240VAC, 4PDT: 5A/240VAC DC1 DPDT: 10A/28VDC, 3PDT: 7A/28VDC : 4PDT: 5A/28VDC Initial resistance ≤ 100mΩ Coil Rated voltage DC 6...110V AC 6...220V Must release voltage DC: ≥0.1Un, AC: ≥0.3Un Operating range of supply voltage See coil tables 1, 2 & 3 Rated power consumption DC 0.9W AC 1.2VA Insulation Insulation resistance ≥100MΩ at 500VDC, 50%RH Dielectric strength coil to contact 1500Vrms, 1min (50Hz), 1mA contact to contact 1000Vrms, 1min (50Hz), 1mA between adjacent contacts 1200Vrms, 1min (50Hz), 1mA General Data Operating time (typical) mS ≤ 15 Release time (typical) mS ≤ 10 Electrical Life ops 1 x 105 Mechanical life ops 1 x 107 Dimensions Weight L x W x H 27 x 21 x 35mm ≤ 35g Ambient temperature storage -55 to 70°C operating -40 to 70°C Shock resistance 10G, 11ms Vibration resistance DA 1.0mm 10-55Hz Page 1 of 3 Ref: DX2 102214JHM www.durakoolrelays.com Sales Department Tel: (888) 847-6552 Specifications are subject to change without notice. E&OE. DX2, DX3, DX4 series industrial plug-in relay Coil Data (DC voltage) Green LED Table 1 Coil Voltage Code Nominal Voltage (VDC) Coil Resistance (Ω) ±10% Power Consumption (mW) Must Operate Voltage max. (VDC) Must Release Voltage min. (VDC) Max. Allowable Voltage (VDC) 1006 6 40 900 4.5 0.6 6.6 1012 12 160 900 9.0 1.2 13.2 1024 24 640 900 18.0 2.4 26.4 1048 48 2600 900 36.0 4.8 52.8 1110 110 13600 900 82.5 11.0 121.0 Coil Data (AC voltage 50Hz) Red LED Table 2 Nominal Voltage (VAC) Coil Resistance (Ω) ±10% Power Consumption (VA) Must Operate Voltage max. (VAC) Must Release Voltage min. (VAC) 3006 6 10 1.2 4.8 1.8 6.6 3012 12 40 1.2 9.6 3.6 13.2 3024 24 158 1.2 19.2 7.2 26.4 3048 48 640 1.2 38.4 14.4 52.8 3110 110 3450 1.2 88.0 33.0 121.0 3230 220/230 15400 1.2 176.0 66.0 242.0 Coil Voltage Code Max. Allowable Voltage (VAC) Coil Data (AC voltage 60Hz) Red LED Table 3 Nominal Voltage (VAC) Coil Resistance (Ω) ±10% Power Consumption (VA) Must Operate Voltage max. (VAC) Must Release Voltage min. (VAC) 6006 6 10.5 1.2 4.8 1.8 6.6 6012 12 42 1.2 9.6 3.6 13.2 6024 24 168 1.2 19.2 7.2 26.4 6048 48 672 1.2 38.4 14.4 52.8 6110 110 3550 1.2 88.0 33.0 121.0 6120 120 4200 1.2 96.0 36.0 132.0 6220 220 14120 1.2 176.0 66.0 242.0 Coil Voltage Code Max. Allowable Voltage (VAC) Ordering Codes D X - 2 0 - 2 - - W T L Series 2, 3, 4 - Number of contact sets Contact material 20 - AgNi 90/10 (standard) see Tables 1, 2 & 3 21 - AgNi 90/10 + Au flash 23 - AgNi 90/10 + Au 5μm plated Contact arrangement 12 - DPDT (2 C/O) 13 - 3PDT (3 C/O) 14 - 4PDT (4 C/O) Cover protection category 2 - in cover, IP40 Connection mode 3 - for plug-in sockets only 5 - for pcb mounting (not UL recognized) NIL - without LED and Test Lever (to special order only) WTL - LED indication of coil energization + Test Lever (standard) Options Page 2 of 3 Ref: DX2 102214JHM www.durakoolrelays.com Sales Department Tel: (888) 847-6552 Specifications are subject to change without notice. E&OE. DX2, DX3, DX4 series industrial plug-in relay Wiring Diagrams Fig. 1 Bottom View Overall Dimensions Fig. 2 All dimensions in mm Page 3 of 3 Ref: DX2 102214JHM American Electronic Components Inc., 1101 Lafayette St. Elkhart, IN46516 www.durakoolrelays.com Sales Department Tel: (888) 847-6552 Specifications are subject to change without notice. E&OE.