Datasheet

DX2, DX3 & DX4 series
industrial plug-in relay
Contacts
Contact number & arrangement
Contact material
*
*
*
*
Industry standard footprint, now with terminal blades
with no holes for better mounting in sockets.
*
RoHS Compliant
Integral LED (Red for AC, Green for DC coils).
Locking Test Lever with press feature.
(Blue for DC, Red for AC coils)
Welded (not soldered) internal electrical connections
for greater reliability.
E325835
DPDT (2 C/O), 3PDT (3C/O), 4PDT (4 C/O)
Ag alloy
Max. switching voltage
AC/DC 277VAC, 30VDC
Min. breaking capacity
W 0.3W
Rated load (resistive - cos φ=1)
AC1 DPDT: 10A/240VAC, 3PDT: 7A/240VAC, 4PDT: 5A/240VAC
DC1 DPDT: 10A/28VDC, 3PDT: 7A/28VDC : 4PDT: 5A/28VDC
Initial resistance
≤ 100mΩ
Coil
Rated voltage
DC 6...110V
AC 6...220V
Must release voltage
DC: ≥0.1Un, AC: ≥0.3Un
Operating range of supply voltage
See coil tables 1, 2 & 3
Rated power consumption
DC 0.9W
AC 1.2VA
Insulation
Insulation resistance
≥100MΩ at 500VDC, 50%RH
Dielectric strength
coil to contact 1500Vrms, 1min (50Hz), 1mA
contact to contact 1000Vrms, 1min (50Hz), 1mA
between adjacent contacts 1200Vrms, 1min (50Hz), 1mA
General Data
Operating time (typical)
mS ≤ 15
Release time (typical)
mS ≤ 10
Electrical Life
ops 1 x 105
Mechanical life
ops 1 x 107
Dimensions
Weight
L x W x H 27 x 21 x 35mm
≤ 35g
Ambient temperature
storage -55 to 70°C
operating -40 to 70°C
Shock resistance
10G, 11ms
Vibration resistance
DA 1.0mm 10-55Hz
Page 1 of 3 Ref: DX2 102214JHM
www.durakoolrelays.com
Sales Department Tel: (888) 847-6552
Specifications are subject to change without notice. E&OE.
DX2, DX3, DX4 series
industrial plug-in relay
Coil Data (DC voltage) Green LED
Table 1
Coil Voltage Code
Nominal Voltage
(VDC)
Coil Resistance (Ω)
±10%
Power Consumption
(mW)
Must Operate Voltage
max. (VDC)
Must Release Voltage
min. (VDC)
Max. Allowable
Voltage (VDC)
1006
6
40
900
4.5
0.6
6.6
1012
12
160
900
9.0
1.2
13.2
1024
24
640
900
18.0
2.4
26.4
1048
48
2600
900
36.0
4.8
52.8
1110
110
13600
900
82.5
11.0
121.0
Coil Data (AC voltage 50Hz) Red LED
Table 2
Nominal Voltage
(VAC)
Coil Resistance (Ω)
±10%
Power Consumption
(VA)
Must Operate Voltage
max. (VAC)
Must Release Voltage
min. (VAC)
3006
6
10
1.2
4.8
1.8
6.6
3012
12
40
1.2
9.6
3.6
13.2
3024
24
158
1.2
19.2
7.2
26.4
3048
48
640
1.2
38.4
14.4
52.8
3110
110
3450
1.2
88.0
33.0
121.0
3230
220/230
15400
1.2
176.0
66.0
242.0
Coil Voltage Code
Max. Allowable
Voltage (VAC)
Coil Data (AC voltage 60Hz) Red LED
Table 3
Nominal Voltage
(VAC)
Coil Resistance (Ω)
±10%
Power Consumption
(VA)
Must Operate Voltage
max. (VAC)
Must Release Voltage
min. (VAC)
6006
6
10.5
1.2
4.8
1.8
6.6
6012
12
42
1.2
9.6
3.6
13.2
6024
24
168
1.2
19.2
7.2
26.4
6048
48
672
1.2
38.4
14.4
52.8
6110
110
3550
1.2
88.0
33.0
121.0
6120
120
4200
1.2
96.0
36.0
132.0
6220
220
14120
1.2
176.0
66.0
242.0
Coil Voltage Code
Max. Allowable
Voltage (VAC)
Ordering Codes
D
X
-
2
0
-
2
-
-
W
T
L
Series
2, 3, 4 - Number of contact sets
Contact material
20
-
AgNi 90/10 (standard)
see Tables 1, 2 & 3
21
-
AgNi 90/10 + Au flash
23
-
AgNi 90/10 + Au 5μm plated
Contact arrangement
12
-
DPDT (2 C/O)
13
-
3PDT (3 C/O)
14
-
4PDT (4 C/O)
Cover protection category
2
-
in cover, IP40
Connection mode
3
-
for plug-in sockets only
5
-
for pcb mounting (not UL recognized)
NIL
-
without LED and Test Lever (to special order only)
WTL
-
LED indication of coil energization + Test Lever (standard)
Options
Page 2 of 3 Ref: DX2 102214JHM
www.durakoolrelays.com
Sales Department Tel: (888) 847-6552
Specifications are subject to change without notice. E&OE.
DX2, DX3, DX4 series
industrial plug-in relay
Wiring Diagrams
Fig. 1
Bottom View
Overall Dimensions
Fig. 2
All dimensions in mm
Page 3 of 3
Ref: DX2 102214JHM
American Electronic Components Inc., 1101 Lafayette St. Elkhart, IN46516
www.durakoolrelays.com
Sales Department Tel: (888) 847-6552