Datasheet

GE
Measurement & Control
ZTP-315
Thermometrics
Thermopile IR Sensor
The ZTP-315 thermopile IR sensor is used for noncontact surface temperature monitoring. The ZTP315 model consists of thermoelements, a flat IR filter,
a thermistor for temperature compensation and a
hermetically-sealed small-size package. There is also a
variety of filters available to maximize performance in
specific applications.
Applications
• HVAC
• Occupancy detection
• Automotive
Features
• Non-contact measurement
• Wider surface area measurement
• Small-size sensor package
• Included ambient temperature
(thermistor) sensor for compensation
• High sensitivity
• Fast response time
• Low cost
Thermopile Chip
Thermistor Resistance (R-T Table)
Parameter
Limits
Min
Typ
Units
Condition
Tamb (°C)
Rmin (kΩ
Rcent (kΩ)
Rmax (kΩ)
-40
847.1
885.1
924.7
2
Max
Chip Size
3.6 x 3.6
mm
-35
624.1
650.2
677.2
Diaphragm Size
2.6 x 2.6
mm2
-30
464.0
481.9
500.5
Active Area
1.3 x 1.3
mm2
-25
348.0
360.3
373.1
-20
263.1
271.7
280.5
-15
200,6
206.5
212.7
-10
154.1
158.3
162.5
-5
119.3
122.2
125.2
Internal Resistance
35
50
22
32
Resistance T.C.
Responsivity
Responsivity T.C.
65
kΩ
0.12
%./ °C
42
V/W
-0.11
Noise Voltage
500K, 1Hz
%./ °C
30
nV rms
R.M.S., 25 °C
0
93.03
95.06
97.12
0.94
nW/Hz1/2
500K, 1 Hz
5
73.07
74.48
75.91
1.38 E08
cmHz1/2/W
500K, 1 Hz
10
57.78
58.76
59.75
25
ms
15
46.00
46.67
47.34
20
36.85
37.30
37.76
25
29.70
30.00
30.30
30
23.98
24.27
24.57
35
19.47
19.75
20.03
40
15.89
16.15
16.42
45
13.04
13.28
13.53
50
10.76
10.98
11.20
55
8.914
9.112
9.314
65
6.202
6.362
6.526
70
5.204
5.348
5.495
75
4.383
4.512
4.644
80
3.704
3.820
3.938
85
3.141
3.244
3.350
90
2.670
2.763
2.858
95
2.277
2.359
2.444
100
1.946
2.019
2.095
105
1.667
1.732
1.800
110
1.430
1.489
1.550
115
1.230
1.282
1.336
120
1.058
1.105
1.153
NEP
Detectivity
25 °C
Time Constant
Thermistor
Parameter
Resistance
Beta - Value
Limits
Units
Min
Typ
Max
29.7
30
30.3
3773
3811
3849
kΩ
K
Absolute Maximum Ratings
Operating Temperature
-20°C ~ 100°C
Storage Temperature
-40°C ~ 120°C
Condition
Tol.:1%, @25 °C
Tol.:1%, Defined at
@25 °C/50 °C
Typical Characteristic Data
Sensitivity
Field of View
Parameter
Field of View
Filter Transmission Data
Limits
Min
Typ
Max
70
75
80
Units
Condition
Degree
50% of
Maximum
Output
Outline of Sensor Package and Pin Arrangement [unit: mm]
Pin Arrangement
1. GND Thermistor
2. Thermopile
3. Thermistor
4. GND Thermopile
www.ge-mcs.com
920-590A
© 2012 General Electric Company. All Rights Reserved. Specifications are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product
names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affiliated with GE.