VTD3 series - Vectron International

VTD3 series
Voltage Controlled Temperature Compensated Crystal Oscillator
Features
• CMOS Output
• Output Frequencies to 61.440 MHz
• Fundamental Crystal Design
• Optional VCXO function available
• Product is compliant to RoHS directive
Applications
• Wireless Communications
The VTD3, VCTCXO
• Base Stations
• Point to point radios
• Broadband Access
• Test Equipment
Description
Vectron’s VTD3 Temperature Compensated
Crystal Oscillator (TCXO) is a quartz stabilized,
CMOS squarewave, temperature compensated
oscillator, operating off either a 3.3 or 5.0 volt
supply.
Vectron International: 267 Lowell Road, Suite 102, Hudson NH 03051
Tel: 1-88-VECTRON-1
e-mail: [email protected]
VTD3 Data sheet
Performance Characteristics
Table 1. Electrical Performance
Parameter
Frequency
Supply Voltage
Maximum Supply Voltage
Supply Current,
Output Frequency<22MHz
Output Frequency=>22MHz
2
Output Level
Logic High
Logic Low
Drive High
Drive Low
Output Load
Duty Cycle, @ 50%
Control Voltage Impedance
Control Voltage to reach pull, 5V option
3.3 V option
Pull Range
Ordering option, see last page
Temperature Stability
Ordering option, see last page.
Initial Accuracy, “No Adjust” option
Power Supply Stability
Load Stability
Aging
Operating temperature
Ordering option, see last page
Phase Noise, 10.000MHz
10 Hz offset
100 Hz offset
1 kHz offset
10 kHz offset
100 kHz offset
Start-up time
Symbol
fO
Min
10.000
Typical
Maximum
61.440
3.3V±5%, 5V±5%
7
Units
MHz
VDC
IDD
15
24
VOH
VOL
IOH
IOL
mA
0.9*VDD
V
V
mA
mA
0.1*VDD
-4
4
15pf
40/60
ZVc
100
0.5
0.3
TPR
4.5
3.0
%
Kohm
V
±5, ±8, ±10, ±15
ppm
±1.0 to ±5.0
ppm
±2.0
ppm
±1.0
ppm
±0.3
ppm
±1.0
ppm/year
0/55, -10/60, -20/70, -30/75, -40/85
°C
dBc/Hz
-107
-138
-148
-152
-154
10
ms
1. A 0.01uF and a 0.1uF capacitor should be located as close to the supply as possible (to ground) is recommended.
2. Output is DC coupled.
Vectron International: 267 Lowell Rd, Suite 102, Hudson NH 03051
Tel: 1-88-VECTRON-1
e-mail: [email protected]
VTD3 Data sheet
VCXO Functional Description
VCXO Feature: The VTD3 can be ordered with a VCXO function for applications where it will be used in a
PLL, or the output frequency needs fine tune adjustments. This is high impedance input, 100 kohm, and
can be driven with an op-amp or terminated with adjustable resistors etc. Pin 1 should not be left
floating on the VCXO optional devices.
“No Adjust” Feature: In applications where the VTD3 will not be used in a PLL, or the output frequency
does not need fine tune adjustments, the fixed TCXO/VTD3-x0xx is the best option. By using the “no
adjust” option, the circuit is simplified as Vc does not need to adjusted or set to a predetermined voltage.
Pin 1 can be grounded to reduce the risk of adding noise into the circuit.
Outline Diagrams, Pad Layout and Pin Out
Table 2. Pin out
Pin #
Symbol
1
N/C or VC
2
GND
3
fO
4
VDD
Function
No Connect (VTD3-x0xx) or VCXO Control Voltage
Electrical and Case Ground
Output Frequency
Supply Voltage
2.0 mm
(max)
VTD3
VTD3-XXXX
Frequency
Date Code
Figure 1, Package drawing and Pad Layout
Vectron International: 267 Lowell Rd, Suite 102, Hudson NH 03051
Tel: 1-88-VECTRON-1
e-mail: [email protected]
VTD3 Data sheet
Tape and Reel
Table 3. Tape and Reel Dimensions (mm)
Tape Dimensions
Product
A
VTD3
24
B
C
D
E
11.5
1.5
4
12
Reel Dimensions
F
G
H
2
21
13
I
J
K
L
80
2
25.5
255
# Per
Reel
1K
J
F
D
C
G
B
A
L
I
E
H
K
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can permanently damage the device. Functional
operation is not implied at these or any other conditions in excess of conditions represented in the
operational sections of this data sheet. Exposure to absolute maximum ratings for extended periods may
adversely affect device reliability.
Table 4. Absolute Maximum Ratings
Parameter
Symbol
Storage Temperature
Tstorage
Ratings
-40/85
Unit
°C
Reliability
The VTD3 qualification tests have included:
Table 5. Environmental Compliance
Parameter
Mechanical Shock
Mechanical Vibration
Temperature Cycle
Solderability
Gross and Fine Leak
Resistance to Solvents
Vectron International: 267 Lowell Rd, Suite 102, Hudson NH 03051
Conditions
MIL-STD-883 Method 2002
MIL-STD-883 Method 2007
MIL-STD-883 Method 1010
MIL-STD-883 Method 2003
MIL-STD-883 Method 1014
MIL-STD-883 Method 2015
Tel: 1-88-VECTRON-1
e-mail: [email protected]
VTD3 Data Sheet
Handling Precautions
Although ESD protection circuitry has been designed into the VTD3, proper precautions should be taken
when handling and mounting. VI employs a Human Body Model and a Charged-Device Model (CDM) for
ESD susceptibility testing and design protection evaluation. ESD thresholds are dependent on the circuit
parameters used to define the model. Although no industry wide standard has been adopted for the CDM,
a standard HBM of resistance = 1.5Kohms and capacitance = 100pF is widely used and therefore can be
used for comparison purposes.
Table 6. ESD Ratings
Model
Human Body Model
Charged Device Model
Minimum
1000
500
Conditions
MIL-STD-883 Method 3015
JESD 22-C101
Suggested IR profile
Table 7 shows max temperatures and lower peak temperatures can also be used e.g. peak temperature
of 230-240°C. The VTD3 should not be subjected to a wash process that will immerse it in solvents – a no
clean process is recommended.
Table 7. Reflow Profile
Parameter
PreHeat Time
Ramp Up
o
Time Above 217 C
Time To Peak Temperature
o
Time At 260 C (max)
Time At 240 °C (max)
Ramp Down
Symbol
tS
R UP
tL
t AMB-P
tP
tp2
R DN
Vectron International: 267 Lowell Rd, Suite 102, Hudson NH 03051
5
Value
60 sec Min, 180 sec Max
o
3 C/sec Max
60 sec Min, 150 sec Max
480 sec Max
6 sec Max
60 sec Max
o
6 C/sec Max
Tel: 1-88-VECTRON-1
e-mail [email protected]
VTD3 Data Sheet
Ordering Information
Table 8. Standard Frequency List
10.00
11.00
12.288
14.40
15.36
16.384
20.00
26.88
27.00
VTD3 -
J
12.352
16.80
32.00
0
12.50
19.20
32.768
2
C
12.80
19.44
44.00
-
13.00
19.6608
44.736
14.31818
19.68
50.000
10M00
Product Family
Output Frequency
TCXO, 9.6 x 11.5
In MHz
Voltage Options
Temperature Options
H: +5.0 Vdc ±5%
A: 0 to 55°C
J: +3.3 Vdc ±5%
B: -10 to 60°C
C: -20 to 70°C
Pulling Range
D: -30 to 75°C
0: Fixed TCXO, no adjust
E: -40 to 85°C
1: ±5ppm
2: ±8ppm
Stability Options
3: ±10ppm
1: ±1.0ppm
4: ±15ppm
B: ±1.5ppm
2: ±2.0ppm
C: ±2.5ppm
3: ±3.0 ppm
4: ±4.0ppm
5: ±5.0ppm
Note: Not all combinations are available
USA: Vectron International • 267 Lowell Road, Suite 102, Hudson, NH 03051
For Additional Information, Please Contact:
• Tel: 1-88-VECTRON-1 • Fax: 1-888-FAX-VECTRON
EUROPE: Landstrasse, D-74924, Neckarbischofsheim, Germany •
Tel: 49 (0) 7268 8010 • Fax: 49 (0) 7268 801281
www.vectron.com
ASIA: Vectron International, 68 Yin Cheng Road (C), 22nd Floor
One LuJiaZui, Pudong, Shanghai 200120, China
•Tel: 8621 61946886 • Fax: 8621 61946699
February 12, 2014
Vectron International: 267 Lowell Rd, Suite 102, Hudson NH 03051
6
Tel: 1-88-VECTRON-1
e-mail [email protected]
VTD3 Data Sheet
Revision
1.6
Date
08/13/07
1.7
1.8
1.9
9/23/09
11/4/13
02/12/14
Description
Increase output frequency from 50MHz to 60MHz, update package marking
and reel dimensions
Correct/update phase noise
Updated VI Asia Contact Information
Added new Vectron Logo and updated Hudson Address
Vectron International: 267 Lowell Rd, Suite 102, Hudson NH 03051
7
Tel: 1-88-VECTRON-1
e-mail [email protected]