26 October 1993 Specification for monolithic crystal filter: MQF 21.4-1500/14 1. General 1.1. Package: 1.2. 1.3. Type name: Number of poles: MQF 21.4-1500/14 8 1.4. 1.5. 1.6. Operable temperature range: Operating temperature range: Storage temperature range: -30°C to 80°C -25°C to 70°C -55°C to 80°C 2. Electric values 2.1. Nominal centre frequency fo: 2.2. Pass band 21.4 MHz 2.2.1. Bandwidth between 3 dB - frequencies: 2.2.2. Ripple: ≥ fo ± 7.5 kHz ≤ 2.0 dB at fo ± 6.0 kHz 2.2.3. Insertion loss: ( measured on smallest attenuation in pass band ) ≤ 4.0 dB 2.3. Stop band 2.3.1. fo ± 17.5 kHz 2.3.2. fo ± 25 kHz.........± 300 kHz ≥ 65 dB ≥ 90 dB 2.4. Terminating impedance ( input and output ): 470 Ω // 15 pF 3. Marking on the case: firm, year week MQF 21.4-1500/14 4. Environment conditions: Corresponding to Telefilter CF001 _____________________________________________________________________________________ Edited by: date: ______________________ name: __________________________