UNISONIC TECHNOLOGIES CO., LTD UU642

UNISONIC TECHNOLOGIES CO., LTD
UU642
LINEAR INTEGRATED CIRCUIT
INTERVAL AND WIPE/WASH
WIPER CONTROL IC

DESCRIPTION
The bipolar integrated circuit UTC UU642 is designed as a
wiper for automotive application. It includes wipe, wash and
internal mode.
The UTC UU642 is a cost-effective solution for an accurate
timing function control. Wipe/wash mode has priority over interval
mode. Interval pause and after-wiping time can be set to fixed
values by using resistors in a broad time range. Added value can
be provided with an individual, continuous adjustment of the
interval pause by a potentiometer which may be built into the
stalk. For proper operation, it is mandatory to feed the signal of
the wiper motor’s park switch into UTC UU642.

FEATURES
* After-wiping time: 2s~20s
* Interval pause: 4s~20s
* Wipe/wash mode priority
* Wiper motor’s park switch
* Relay driver with Z-diode
* One external capacitor determines all time sequences
* Interference protection according to VDE 0839 or ISO/TR 637/1
* Load-dump protected

ORDERING INFORMATION
Ordering Number
Lead Free
UU642L-D08-T
UU642L-S08-R
Halogen Free
UU642G-D08-T
UU642G-S08-R
Package
Packing
DIP-8
SOP-8
Tube
Tape Reel
UU642L-D08-T
(1)Packing Type
(1) T: Tube, R: Tape Reel
(2)Package Type
(2) D08: DIP-8, S08: SOP-8
(3)Halogen Free
(3) L: Lead Free, G: Halogen Free
www.unisonic.com.tw
Copyright © 2014 Unisonic Technologies Co., Ltd
1 of 6
QW-R121-023.B
UU642

LINEAR INTEGRATED CIRCUIT
MARKING INFORMATION
PACKAGE
MARKING
SOP-8
DIP-8


PIN CONFIGURATION
GND
1
8
VS
INT
2
7
OUT
CT
3
6
PARK
RT
4
5
WASH
PIN DESCRIPTION
PIN NO.
1
2
3
4
5
6
7
8
PIN NAME
GND
INT
CT
RT
WASH
PARK
OUT
VS
DESCRIPTION
Ground
Interval switch
Timing capacitor C2
After-wiping time resistance
Wipe/wash switch
Park switch for wiper motor
Relay control output
Supply voltage terminal 15
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
2 of 6
QW-R121-023.B
UU642

LINEAR INTEGRATED CIRCUIT
BLOCK DIAGRAM
VS
8
OUT
7
PARK
6
WASH
5
VRef
VRef
Park switch
comparator
VRef
Input
comparator
Load-dump
comparator
Logic
Wipe/wash
comparator
VRef
Interval
comparator
1
GND
A
B
2
INT
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
C
D
3
Ct
E
F
4
Rt
3 of 6
QW-R121-023.B
UU642

LINEAR INTEGRATED CIRCUIT
ABSOLUTE MAXIMUM RATING
PARAMETER
Supply Voltage t=60s, Terminal 15
SYMBOL
VBatt
t=2ms
t=200ms
Supply Current
I8
RATINGS
28
1.5
150
200
1.2
UNIT
V
A
mA
mA
A
RATINGS
120
160
UNIT
K/W
K/W
Relay Control Output Current (DC)
I7
Relay Control Output Current (DC)
t=200ms
Pulse Current (Control Inputs) t=200ms
Park Switch, S1
I6
50
mA
Wipe/Wash Switch, S3
I5
50
mA
Interval Switch, S2
I2
50
mA
Power Dissipation TAMB=90°C
PD
500
mW
Ambient Temperature Range
TA
-40~+85
°C
Storage Temperature Range
TSTG
-55~+125
°C
Note: Absolute maximum ratings are those values beyond which the device could be permanently damaged.
Absolute maximum ratings are stress ratings only and functional device operation is not implied.

THERMAL RESISTANCE
PARAMETER
Junction to Ambient

SYMBOL
DIP-8
SOP-8
θJA
ELECTRICAL CHARACTERISTICS
(VBatt=12V, TA=25°C, reference point is pin 8, unless otherwise specified.)
PARAMETER
SYMBOL
TEST CONDITIONS
Supply Voltage
VBatt
Supply Current
I8
Z-Diode Limitation
V1
Overvoltage
Threshold Current
I1
Threshold Voltage
VBatt
Relay Control Output
I7=100mA
Saturation Voltage
V7
I7=200mA
Leakage Current
I7
Park Switch
Internal Pull-Up Resistance
R6
R6=10kΩ
Switching Threshold Voltage
V6
I6=-10mA
Protection Diode
V6
I6=10mA
Input Ct
Internal Resistance
R3
Interval Input
R2=2.7~30kΩ
I2=-10mA
Protection Diode
V2
I2=30mA/10ms
WASH Input
R5=10kΩ
Switching Threshold/Hysteresis
V5
I5=-10mA
Protection Diode
V
I5=10mA
Switching Characteristics
R4=47kΩ~300kΩ, I4=-150μA
R3=0kΩ
Interval Time
t2
R3=10kΩ
Prewash Delay
tdel
After-Wipe-Time
t5
R4=130kΩ
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
MIN
9
TYP
MAX
16.5
9
7.6
UNIT
V
mA
V
-50
37
mA
V
-1.0
-1.5
100
V
V
μA
41
-3.1
-0.8
7.6
kΩ
V
V
V
100
Ω
-0.8
7.6
V
V
-1.1/-7.1
-0.87
8.7
V
V
V
3.45
10.8
80
4.7
s
s
ms
s
4 of 6
QW-R121-023.B
UU642

LINEAR INTEGRATED CIRCUIT
TYPICAL APPLICATION CIRCUIT
R6 10kΩ R5 10kΩ
8
6
7
UTC UU642
Relay
C1
47µF
10V
2
1
3
4
R1
C2
22µF
R4
510Ω
Rtime=130kΩ
R2 2.7kΩ
R3
S1
Park
switch
5
10kΩ
S2
WIWA
M
M
S3
Wiper motor
Interval switch
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
Water pump
31
15
5 of 6
QW-R121-023.B
UU642
LINEAR INTEGRATED CIRCUIT
TYPICAL CHARACTERISTICS

Interval Time (R3=0Ω)
Interval time (R3=10KΩ)
CH1
CH2
CH2
CH1: 2V/div
CH2: 2Vdiv
CH1: 2V/div
CH2: 2Vdiv
CH1
0
0
0
5
Time (1s/div)
10
0
Prewash Delay
20
After Wipe Time
CH2
CH2
CH1: CH2:
5V/div 5Vdiv
CH1
CH1: CH2:
5V/div 5Vdiv
10
Time (2s/div)
0
0
CH1
0
0
0
100
Time (20ms/div)
200
0
5
Time (1s/div)
10
UTC assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or
other parameters) listed in products specifications of any and all UTC products described or contained
herein. UTC products are not designed for use in life support appliances, devices or systems where
malfunction of these products can be reasonably expected to result in personal injury. Reproduction in
whole or in part is prohibited without the prior written consent of the copyright owner. The information
presented in this document does not form part of any quotation or contract, is believed to be accurate
and reliable and may be changed without notice.
UNISONIC TECHNOLOGIES CO., LTD
www.unisonic.com.tw
6 of 6
QW-R121-023.B