Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD SPECIFICATIONS FOR LCD MODULE CUSTOMER CUSTOMER PART NO. AMPIRE PART NO. AM320240L2TMQW-B0H (Use TMR Polarizer) APPROVED BY DATE ; Approved For Specifications Approved For Specifications & Sample AMPIRE CO., LTD. 2F., No.88, Sec. 1, Sintai 5th Rd., Sijhih City, Taipei County 221, Taiwan (R.O.C.)台北縣汐止市新台五路一段 88 號 2 樓(東方科學園區 D 棟) TEL:886-2-26967269 , FAX:886-2-26967196 or 26967270 APPROVED BY Date : 2008/08/21 CHECKED BY AMPIRE CO., LTD. ORGANIZED BY 1 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD RECORD Revision Date Page 2008/06/26 -- OF REVISION Contents Editor New Release. Kasha (With TMR Polarizer) 2008/8/21 4 Date : 2008/08/21 Revise Functional Block Diagram AMPIRE CO., LTD. Edward 2 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 1 General Description and Features 3.5 inch Amorphous-TFT-LCD (Thin Film Transistor Liquid Crystal Display) module. This module is composed of a 3.5” TFT-LCD panel, a driver circuit and backlight unit. 1.1 Construction: 3.5” a-Si color TFT-LCD, White LED Backlight and PCB. 1.2 Resolution (pixel): 320(R.G.B) X240. 1.3 Number of the Colors: 16M colors (R, G, B 8 bit digital each). 1.4 LCD type: Transmissive Color TFT LCD (normally White). 1.5 View Angle: 6 o’clock. 1.6 24Bit RGB Interface. 1.7 Interface: 54 pin. 1.8 Power Supply Voltage: 3.3V single power input. Built-in power supply circuit. 1.9 LED Type Backlight. 1.10 With OTP function. (Loading initial code automatically). 2 Physical specifications Item Specifications unit 320(W) x 240(H) dot Active area 70.08 x 52.56 mm Screen size 3.5(Diagonal) inch 0.073 (W) x 0.219 (H) mm Display Resolution Dot pitch Color configuration R.G.B – stripe Overall Dimension 77.8(W) x 64.5(H) x3.2(T) Input interface Surface Treatment digital 24-bits RGB Anti - glare(AG) Backlight unit White LED Display Mode Normally White/Transmissive Date : 2008/08/21 mm AMPIRE CO., LTD. 3 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 3 Functional Block Diagram Date : 2008/08/21 AMPIRE CO., LTD. 4 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 4 Electrical Specifications TFT LCD Panel FPC Descriptions No. Symbol I/O 1. 2. 3. 4. 5. 6. 7. 8. VBLVBLVBL+ VBL+ NC SDO NC /RESET I I I I O I 9. /CS I 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. 34. 35. 36. 37. 38. SPCLK SPDAT B0 B1 B2 B3 B4 B5 B6 B7 G0 G1 G2 G3 G4 G5 G6 G7 R0 R1 R2 R3 R4 R5 R6 R7 HSYNC VSYNC DCLK I I I I I I I I I I I I I I I I I I I I I I I I I I I I I Date : 2008/08/21 Description Remark Backlight LED Cathode. Backlight LED Cathode. Backlight LED Anode. Backlight LED Anode. No connection. SPI Interface Data Out. No connection. Hardware Reset Input, Low active. Chip select pin of serial interface. - Leave it OPEN when not used. SPI Interface Data Clock. SPI Interface Data Clock. Blue Data for Digital RGB Interface. Green Data for Digital RGB Interface. Red Data for Digital RGB Interface. Horizontal Sync Input. Vertical Sync Input. Dot Data Clock. AMPIRE CO., LTD. 5 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 39. 40. 41. 42. 43. 44. 45. 46. 47. 48. 49. 50. 51. 52. 53. 54. NC NC VCC VCC NC NC VGL NC VGH NC NC NC NC ENB GND GND I I I - No connection. No connection. Digital Power (3.3V). No connection. For initial Code OTP Use (Keep NC). For initial Code OTP Use (Keep NC). No connection. Data Enable Input. Ground. 5 Basic Display Color and Gray Scale Date : 2008/08/21 AMPIRE CO., LTD. 6 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 6 Absolute Maximum Ratings If the operating condition exceeds the following absolute maximum ratings, the TFT LCD module may be damaged permanently. 6.1 Environmental Absolute max. ratings OPERATING STORAGE Item MIN MAX MIN MAX Temperature -20 70 -30 80 Humidity Note1 Note1 Corrosive Gas Not Acceptable Not Acceptable Remark Note2,3,4,5,6,7,8 Note1 : Ta <= 40℃ : 85% RH max Ta > 40℃ : Absolute humidity must be lower than the humidity of 85%RH at 40℃ Note2 : For storage condition Ta at -30℃ < 48h , at 80℃ < 100h For operating condition Ta at -20℃ < 100h Note3 : Background color changes slightly depending on ambient temperature. This phenomenon is reversible. Note4 : The response time will be slower at low temperature. Note5 : Only operation is guarantied at operating temperature. Contrast , response time, another display quality are evaluated at +25℃ Note6 : When LCM is operated over 40℃ ambient temperature, the I LED of the LED back-light should be follow (1 LED Dice) : BB BB Note7 : This is panel surface temperature, not ambient temperature. Date : 2008/08/21 AMPIRE CO., LTD. 7 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD Note8 : When LCM be operated over than 40℃ , the life time of the LED back-light will be reduced. 6.2 Electrical Absolute max. ratings Item Symbol Condition Power voltage VDD Input voltege V in BB VSS=0 BB Min. Max. Unit -0.3 6.0 V -0.3 VDD+0.3 V Remark Note 1 Note1:Hsync, Vsync, DEN, DCLK, R0~R7, G0~G7, B0~B7 7 Electrical Characteristics 7.1 DC Electrical characteristic of the LCD Typical operting conditions (VSS=0V) Symbol Min. Typ. Item Power supply Max. Unit VDD 3.0 3.3 3.6 V Input Voltage H Level V IH 0.7 VDD - VDD V for logic L Level V IL 0 - 0.3 VDD V 14.78 -- mA Power Supply current BB BB BB BB IDD Remark Note 1 Note 2 Note1:Hsync, Vsync, DEN, DCLK, R0~R7, G0~G7, B0~B7 Note2: fV =60Hz , Ta=25℃ , Display pattern : All Black 7.2 Electrical characteristic of LED Back-light Parameter Symbol Min. Typ. Max. LED voltage V AK 9.6 11 BB LED forward current Condition I LED=40mA,Ta=25℃ BB I LED -- 40 - mA Ta=25℃ I LED -- 30 - mA Ta=60℃ BB BB Date : 2008/08/21 BB Unit V BB BB AMPIRE CO., LTD. 8 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD Life Time Curve/1 LED dice 8 AC Timing characteristic of the LCD Pixel Timing Pixel Timing Table Date : 2008/08/21 AMPIRE CO., LTD. 9 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD (a) Data Transaction Timing in Parallel RGB (24 bit) Interface (SYNC Mode) Date : 2008/08/21 AMPIRE CO., LTD. 10 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD b) Data Transaction Timing in Parallel RGB (24 bit) Interface (DE Mode) Data Transaction Timing in Normal Operating Mode Date : 2008/08/21 AMPIRE CO., LTD. 11 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD Data Transaction Timing in Serial RGB (8 bit) Interface (SYNC Mode) Data Transaction Timing in Serial RGB (8 bit) Interface (DE Mode) Date : 2008/08/21 AMPIRE CO., LTD. 12 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD Date : 2008/08/21 AMPIRE CO., LTD. 13 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD Date : 2008/08/21 AMPIRE CO., LTD. 14 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 9 Optical specification 9.1 Optical characteristic of the LCD Item Symbol Condition Response Time T r+ T f Θ=0° Contrast ratio CR At optimized viewing angle CR≧10 Viewing Angle BB BB BB BB Θx+ ΘxΘy+ Θy- Brightness YL BB BB I LED =20mA ,25℃ I LED =20mA ,25℃ BB BB Min. Typ. Max. Unit Remark 50 80 ms Note 1,2,3,5 - 300 - - 60 60 35 55 - deg. 250 280 - cd/m 2 Note 1,2,4,5 PP Note1,2, 5,6 PP Note 7 XW 0.26 0.34 0.27 0.35 YW XR 0.57 0.61 0.65 Red chromaticity YR 0.32 0.36 0.40 XG Θ=0° 0.31 0.35 0.39 Green chromaticity Θ=0° YG 0.54 0.58 0.62 XB 0.10 0.14 0.20 Blue chromaticity YB 0.03 0.07 0.11 Note 1: Note 1:Ambient temperature=25℃,and lamp current I LED =20mA.To be measured in the dark room. Note 2:To be measured on the center area of panel with a viewing cone of 1°by Topcon luminance meter BM-7,after 10 minutes operation. Note 3.Definition of response time: The output signals of photo detector are measured when the input signals are changed from “black“ to “white”(falling time) and from”white” to “black” (rising time),respectively.The response time is defined as the time interval between the 10% and 90% of amplitudes. Refer to figure as below. White chromaticity BB BB BB Date : 2008/08/21 AMPIRE CO., LTD. BB 15 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD Note 4.Definition of contrast ratio: Contrast ratio is calculated with the following formula. Contrast ratio (CR) = Photo detector output when LCD is at ”White” state Photo detector Output when LCD is at “Black” state Note 5:White V i =V i50 +1.5V Black V i =V i50 +2.0V “±”means that the analog input signal swings in phase with V COM signal. “ “ means that the analog input signal swings out of phase with V COM signal. V i50 : The analog input voltage when transmission is 50%.The 100% Transmission is defined as the transmission of LCD panel when all the Input terminals of module are electrically opened. BB BB BB BB BB BB BB BB BB BB BB BB BB BB Note 6.Definition of viewing angle, Refer to figure as below. Date : 2008/08/21 AMPIRE CO., LTD. 16 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD Note 7.Measured at the center area of the panel when all the input terminals of LCD panel are electrically opened. Ring light Brightness gauge BM-7 (Topcon) LCD module Metal halide lamp Glass fiber LED:OFF, LIGHT:ON LCD Optical Detector Brightness gauge BM-7 (Topcon) LED LED:ON, LIGHT:OFF Date : 2008/08/21 AMPIRE CO., LTD. 17 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 10 QUALITY AND RELIABILITY 10.1 TEST CONDITIONS Tests should be conducted under the following conditions: Ambient temperature: 25 ± 5°C Humidity : 60 ± 25% RH. 10.2 SAMPLING PLAN Sampling method shall be in accordance with MIL-STD-105E, level II, normal single sampling plan . 10.3 ACCEPTABLE QUALITY LEVEL A major defect is defined as one that could cause failure to or materially reduce the usability of the unit for its intended purpose. A minor defect is one that does not materially reduce the usability of the unit for its intended purpose or is an infringement from established standards and has no significant bearing on its effective use or operation. 10.4 APPEARANCE An appearance test should be conducted by human sight at approximately 30 cm distance from the LCD module under fluorescent light. The inspection area of LCD panel shall be within the range of following limits. Date : 2008/08/21 AMPIRE CO., LTD. 18 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 10.5 INSPECTION QUALITY CRITERIA No. Item 1 Non display 2 Irregular operation Criterion for defects Defect type No non display is allowed Major No irregular operation is allowed Major 3 Short No short are allowed Major 4 Open Any segments or common patterns that don’t activate are rejectable. Major 5 6 7 8 9 Black/White spot Black/White line Back Light dot defect Size D (mm) D < 0.15 0.15 < D < 0.20 0.20 < D < 0.30 0.30 < D UU UU UU UU UU Length(mm) 10 < L 5.0 < L < 10 1.0 < L < 5.0 L < 1.0 UU UU UU UU UU UU Acceptable number Ignore 3 2 0 UU Width (mm) 0.03 < W < 0.04 0.04 < W < 0.06 0.06 < W < 0.07 0.07 < W < 0.09 UU UU UU UU UU UU UU UU Acceptable number 5 3 2 1 1. No Lighting is rejectable 2. Flickering and abnormal lighting are rejectable Bright dot N≦1 Dark dot N≦3 Total dot defect (Bright dot + Dark dot) Minimum distance between dark dot and dark dot A+B ≤ 0.30 0 < C 2 Minor Major Minor N≦3 L≧5 mm Unit:mm Display pattern Minor Minor D+E F+G ≤ 0.25 ≤ 0.25 2 2 Note: 1. Acceptable up to 3 damages 2. NG if there’re to two or more pinholes per dot Date : 2008/08/21 AMPIRE CO., LTD. 19 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD Blemish & Foreign matters 10 Size D (mm) D < 0.15 0.15 < D < 0.20 0.20 < D < 0.30 0.30 < D UU Size: A+ B D= 2 Scratch on Polarizer 11 UU UU UU UU Width (mm) W < 0.0 UU UU 3 0.03<W < 0.05 UU UU 0.05<W < 0.08 UU Acceptable number Ignore 3 2 0 UU UU Length (mm) Ignore L < 2.0 L > 2.0 L > 1.0 L < 1.0 Note (1) UU UU UU UU Acceptable number Ignore Ignore 1 1 Ignore Note(1) Minor Minor 0.08<W Note(1) Regard as a blemish Bubble in 12 polarizer Size D (mm) D < 0.20 0.20 < D < 0.50 0.50 < D < 0.80 0.80 < D UU UU UU UU UU UU Acceptable number Ignore 3 2 0 Minor Stains on LCD panel 13 surface Stains that cannot be removed even when wiped lightly with a soft cloth or similar cleaning too are rejectable. Minor 14 Rust which is visible in the bezel is rejectable. Minor Evident crevices which is visible are rejectable. Minor 16 mounting 1. Failure to mount parts 2. Parts not in the specifications are mounted 3. Polarity, for example, is reversed Parts 17 alignment 1. LSI, IC lead width is more than 50% beyond pad outline. 2. Chip component is off center and more than 50% of the leads is off the pad outline. Major Major Major Minor Conductive foreign matter 18 (Solder ball, Solder chips) 1. 0.45<φ ,N≧1 2. 0.30<φ < 0.45 ,N≧1 φ:Average diameter of solder ball (unit: mm) 3. 0.50<L ,N≧1 L: Average length of solder chip (unit: mm) Rust in Bezel Defect of land surface 15 contact (poor soldering) Parts Date : 2008/08/21 UU UU AMPIRE CO., LTD. Minor Major Minor Minor 20 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD Faulty PCB 19 correction 1. Due to PCB copper foil pattern burnout, the pattern is connected, using a jumper wire for repair; 2 or more places are corrected per PCB. 2. Short circuited part is cut, and no resist coating has been performed. Date : 2008/08/21 AMPIRE CO., LTD. Minor Minor 21 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 10.6 RELIABILITY Test Item Test Conditions High Temperature Operation 70±3°C , t=96 hrs Low Temperature Operation -20±3°C , t=96 hrs High Temperature Storage 80±3°C , t=96 hrs 1,2 Low Temperature Storage -30±3°C , t=96 hrs 1,2 40°C , Humidity 90%, 96 hrs 1,2 Humidity Test Thermal Shock Test Vibration Test (Packing) Static Electricity -30°C ~ 25°C ~ 80°C 30 min. 5 min. 30 min. ( 1 cycle ) Total 5 cycle Sweep frequency:10~55~10 Hz/1min Amplitude : 0.75mm Test direction : X.Y.Z/3 axis Duration : 30min/each axis 150pF 330 ohm + 8kV, 10times air discharge UU Note 1,2 2 UU Note 1 : Condensation of water is not permitted on the module. Note 2 : The module should be inspected after 1 hour storage in normal conditions (15-35°C , 45-65%RH). Definitions of life end point : z Current drain should be smaller than the specific value. z Function of the module should be maintained. z Appearance and display quality should not have degraded noticeably. z Contrast ratio should be greater than 50% of the initial value. Date : 2008/08/21 AMPIRE CO., LTD. 22 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 11 USE PRECAUTIONS 11.1 Handling precautions 1) The polarizing plate may break easily so be careful when handling it. Do not touch, press or rub it with a hard-material tool like tweezers. 2) Do not touch the polarizing plate surface with bare hands so as not to make it dirty. If the surface or other related part of the polarizing plate is dirty, soak a soft cotton cloth or chamois leather in benzine and wipe off with it. Do not use chemical liquids such as acetone, toluene and isopropyl alcohol. Failure to do so may bring chemical reaction phenomena and deteriorations. 3) Remove any spit or water immediately. If it is left for hours, the suffered part may deform or decolorize. 4) If the LCD element breaks and any LC stuff leaks, do not suck or lick it. Also if LC stuff is stuck on your skin or clothing, wash thoroughly with soap and water immediately. 11.2 Installing precautions 1) To prevent breaking by static electricity from the human body and clothing, earth the human body properly using the high resistance and discharge static electricity during the operation. In this case, however, the resistance value should be approx. 1MΩ and the resistance should be placed near the human body rather than the ground surface. When the indoor space is dry, static electricity may occur easily so be careful. We recommend the indoor space should be kept with humidity of 60% or more. When a soldering iron or other similar tool is used for assembly, be sure to earth it. 2) When installing the module and ICs, do not bend or twist them. Failure to do so may crack LC element and cause circuit failure. 3) To protect LC element, especially polarizing plate, use a transparent protective plate (e.g., acrylic plate, glass etc) for the product case. 4) Do not use an adhesive like a both-side adhesive tape to make LCD surface (polarizing plate) and product case stick together. Failure to do so may cause the polarizing plate to peel off. Date : 2008/08/21 AMPIRE CO., LTD. 23 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 11.3 Storage precautions 1) Avoid a high temperature and humidity area. Keep the temperature between 0°C and 35°C and also the humidity under 60%. 2) Choose the dark spaces where the product is not exposed to direct sunlight or fluorescent light. 3) Store the products as they are put in the boxes provided from us or in the same conditions as we recommend. 11.4 Operating precautions 1) Do not boost the applied drive voltage abnormally. Failure to do so may break ICs. When applying power voltage, check the electrical features beforehand and be careful. Always turn off the power to the LC module controller before removing or inserting the LC module input connector. If the input connector is removed or inserted while the power is turned on, the LC module internal circuit may break. 2) The display response may be late if the operating temperature is under the normal standard, and the display may be out of order if it is above the normal standard. But this is not a failure; this will be restored if it is within the normal standard. 3) The LCD contrast varies depending on the visual angle, ambient temperature, power voltage etc. Obtain the optimum contrast by adjusting the LC dive voltage. 4) When carrying out the test, do not take the module out of the low-temperature space suddenly. Failure to do so will cause the module condensing, leading to malfunctions. 5) Make certain that each signal noise level is within the standard (L level: 0.2Vdd or less and H level: 0.8Vdd or more) even if the module has functioned properly. If it is beyond the standard, the module may often malfunction. In addition, always connect the module when making noise level measurements. 6) The CMOS ICs are incorporated in the module and the pull-up and pull-down function is not adopted for the input so avoid putting the input signal open while the power is ON. 7) The characteristic of the semiconductor element changes when it is exposed to light emissions, therefore ICs on the LCD may malfunction if they receive light emissions. To prevent these malfunctions, design and assemble ICs so that they are shielded from light emissions. Date : 2008/08/21 AMPIRE CO., LTD. 24 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 8) Crosstalk occurs because of characteristics of the LCD. In general, crosstalk occurs when the regularized display is maintained. Also, crosstalk is affected by the LC drive voltage. Design the contents of the display, considering crosstalk. 11.5 Other 1) Do not disassemble or take the LC module into pieces. The LC modules once disassembled or taken into pieces are not the guarantee articles. 2) The residual image may exist if the same display pattern is shown for hours. This residual image, however, disappears when another display pattern is shown or the drive is interrupted and left for a while. But this is not a problem on reliability. 3) AMIPRE will provide one year warrantee for all products and three months warrantee for all repairing products. Date : 2008/08/21 AMPIRE CO., LTD. 25 Preliminary The contents of this document are confidential and must not be disclosed wholly or in part to any third part without the prior written consent of AMPIRE CO., LTD 修改上鐵件卡孔 晶采 光 電 科技 12 Mechanical Dimensions Date : 2008/08/21 AMPIRE CO., LTD. 26