VRLA Rechargeable Battery Measures HR75-12 FEATURES Technology Values Innovation APPLICATION Maintenance free(no water topping-up required). No free acid(Non-spillable battery). Low self-discharge rate, lower than 3% capacity loss per month. Can be used in any orientation(excluding used inverted). The battery is designed for high rate usage. Absorbent Glass Mat technology for efficient gas recombination. The power density at 5 min~15min discharging rate is 30% higher than BP series. UPS Wheelchairs Golf-Carts SPECIFICATIONS Nominal Voltage Nominal Capacity Approx. Weight Terminals Internal Resistance Max. Discharge Current Max. Charge Current 12 V 73Ah @ 10 hour rate F.V.(1.75V/cell) 24.75Kg(54.57lbs.) B5 (Fitting M6 bolt & nut) I2 is optional 4m (Fully Charged ) 650 A (5 sec.) 21.9 A Operating Temperature Range Charge 0oC~40oC(32oF~104oF) Discharge -20oC~50oC(-4oF~122oF) Storage. -20oC~40oC(-4oF~104oF) Container Material Standard: ABS( UL 94-HB) HR75-12 Optional: Flame Retardant ABS(UL 94-V0) HR75-12FR DIMENSION(mm/inch) OUTER DIMENSIONS TERMINAL TYPE Length 166 2.0 (6.54 0.08) 174 2.0(6.86 0.08) 0.08) Total Height 174±2.0 (6.85±0.08) [M6 BOLT & NUT] o 1.80V 1.70V 1.60V 1.50V 1.40V 1.30V o Unit: W 5 Min 10 Min 15 Min 20 Min 30 Min 40 Min 50 Min 60 Min 120 Min 3019.5 2099.9 1520.7 1297.8 986.3 750.0 625.6 551.3 303.8 3674.6 2344.4 1647.3 1373.0 1027.5 778.5 646.9 563.4 310.1 3936.9 2465.8 1728.8 1425.1 1049.6 796.5 660.0 573.7 315.0 4050.0 2512.6 1766.3 1447.5 1063.2 806.3 667.5 579.4 316.8 4125.0 2547.9 1786.0 1460.4 1070.9 811.5 672.2 585.0 317.7 4162.4 2565.0 1799.9 1470.0 1076.3 815.7 676.7 585.0 318.6 o o Constant current discharge characteristics at 25 C/77 F F.V. (V/cell) Discharge Time 1.80V 1.70V 1.60V 1.50V 1.40V 1.30V [M6 BOLT] Terminal Hardware Initial Torque: B5/ I2(5.5Nm±5%) Constant power discharge characteristics at 25 C/77 F Discharge Time 2.0(0.08) 2.0 (13.78 7.0(0.28) 350 M6x1.0 6.3 (0.25) 19.0(0.75) (6.54±0.08) 7.0(0.28) 21.0 (0.83) Container Height 174±2.0 (6.85±0.08) F.V. (V/cell) Terminal I2 Terminal B5 350±2.0 (13.78±0.08) Width 166±2.0 IEC 61056-1 JIS C 8702-1 GB/T 19639.1 W Unit: A 5 Min 10 Min 15 Min 20 Min 30 Min 40 Min 50 Min 60 Min 120 Min 274.50 184.20 131.55 111.30 83.59 63.08 52.35 45.94 25.31 334.05 205.65 142.50 117.75 87.08 65.48 54.14 46.95 25.84 357.90 216.30 149.55 122.22 88.95 66.99 55.23 47.81 26.25 368.18 220.40 152.79 124.14 90.10 67.81 55.86 48.29 26.40 375.00 223.50 154.50 125.25 90.75 68.25 56.25 48.75 26.48 378.40 225.00 155.70 126.07 91.21 68.60 56.63 48.75 26.55 All data and artworks shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto. A/4 REV. Jun. 2013 Powered by B.B. Battery Co., Ltd.