HR75-12 - BB

VRLA Rechargeable Battery
Measures
HR75-12
FEATURES
Technology
Values
Innovation
APPLICATION
Maintenance free(no water topping-up required).
No free acid(Non-spillable battery).
Low self-discharge rate, lower than 3% capacity loss per month.
Can be used in any orientation(excluding used inverted).
The battery is designed for high rate usage.
Absorbent Glass Mat technology for efficient gas recombination.
The power density at 5 min~15min discharging rate is 30% higher
than BP series.
UPS
Wheelchairs
Golf-Carts
SPECIFICATIONS
Nominal Voltage
Nominal Capacity
Approx. Weight
Terminals
Internal Resistance
Max. Discharge Current
Max. Charge Current
12 V
73Ah @ 10 hour rate F.V.(1.75V/cell)
24.75Kg(54.57lbs.)
B5 (Fitting M6 bolt & nut) I2 is optional
4m (Fully Charged )
650 A (5 sec.)
21.9 A
Operating Temperature Range
Charge 0oC~40oC(32oF~104oF)
Discharge -20oC~50oC(-4oF~122oF)
Storage. -20oC~40oC(-4oF~104oF)
Container Material
Standard: ABS( UL 94-HB) HR75-12
Optional: Flame Retardant ABS(UL 94-V0) HR75-12FR
DIMENSION(mm/inch)
OUTER DIMENSIONS
TERMINAL TYPE
Length
166
2.0 (6.54
0.08)
174 2.0(6.86 0.08)
0.08)
Total Height
174±2.0 (6.85±0.08)
[M6 BOLT & NUT]
o
1.80V
1.70V
1.60V
1.50V
1.40V
1.30V
o
Unit: W
5 Min
10 Min
15 Min
20 Min
30 Min
40 Min
50 Min
60 Min
120 Min
3019.5
2099.9
1520.7
1297.8
986.3
750.0
625.6
551.3
303.8
3674.6
2344.4
1647.3
1373.0
1027.5
778.5
646.9
563.4
310.1
3936.9
2465.8
1728.8
1425.1
1049.6
796.5
660.0
573.7
315.0
4050.0
2512.6
1766.3
1447.5
1063.2
806.3
667.5
579.4
316.8
4125.0
2547.9
1786.0
1460.4
1070.9
811.5
672.2
585.0
317.7
4162.4
2565.0
1799.9
1470.0
1076.3
815.7
676.7
585.0
318.6
o
o
Constant current discharge characteristics at 25 C/77 F
F.V.
(V/cell)
Discharge
Time
1.80V
1.70V
1.60V
1.50V
1.40V
1.30V
[M6 BOLT]
Terminal Hardware Initial Torque: B5/ I2(5.5Nm±5%)
Constant power discharge characteristics at 25 C/77 F
Discharge
Time
2.0(0.08)
2.0 (13.78
7.0(0.28)
350
M6x1.0
6.3 (0.25)
19.0(0.75)
(6.54±0.08)
7.0(0.28)
21.0 (0.83)
Container Height
174±2.0 (6.85±0.08)
F.V.
(V/cell)
Terminal I2
Terminal B5
350±2.0 (13.78±0.08)
Width
166±2.0
IEC 61056-1
JIS C 8702-1
GB/T 19639.1
W
Unit: A
5 Min
10 Min
15 Min
20 Min
30 Min
40 Min
50 Min
60 Min
120 Min
274.50
184.20
131.55
111.30
83.59
63.08
52.35
45.94
25.31
334.05
205.65
142.50
117.75
87.08
65.48
54.14
46.95
25.84
357.90
216.30
149.55
122.22
88.95
66.99
55.23
47.81
26.25
368.18
220.40
152.79
124.14
90.10
67.81
55.86
48.29
26.40
375.00
223.50
154.50
125.25
90.75
68.25
56.25
48.75
26.48
378.40
225.00
155.70
126.07
91.21
68.60
56.63
48.75
26.55
All data and artworks shall be changed without prior notice, BB reserves the right to explain and update the information contained hereinto.
A/4
REV. Jun. 2013
Powered by
B.B. Battery Co., Ltd.