MT9075B E1 Single Chip Transceiver

MT9075B
E1 Single Chip Transceiver
Data Sheet
Features
•
August 2011
Combined PCM 30 framer, Line Interface Unit
(LIU) and link controllers in a 68 pin PLCC or 100
pin MQFP package
Ordering Information
MT9075BPR1 68 Pin PLCC* Tape & Reel
MT9075BP1
68 Pin PLCC* Tubes
MT9075BL1
100 Pin MQFP* Trays
*Pb Free Matte Tin
•
Selectable bit rate data link access with optional
Sa bits HDLC controller (HDLC0) and channel 16
HDLC controller (HDLC1)
•
LIU dynamic range of 20 dB
•
Enhanced performance monitoring and
programmable error insertion functions
•
Low jitter DPLL for clock generation
Applications
•
Operating under synchronized or free run mode
•
E1 add/drop multiplexers and channel banks
•
Two-frame receive elastic buffer with controlled
slip direction indication
•
CO and PBX equipment interfaces
•
Selectable transmit or receive jitter attenuator
•
Primary Rate ISDN nodes
•
Intel or Motorola non-multiplexed parallel
microprocessor interface
•
Digital Cross-connect Systems (DCS)
•
CRC-4 updating algorithm for intermediate path
points of a message-based data link application
•
ST-BUS/GCI 2.048 Mbit/s backplane bus for both
data and signalling
-40C to +85C
National
Bit Buffer
CAS
Buffer
HDLC0,
HDLC1
DG Loop
Receive Framing, Performance Monitoring,
Alarm Detection, 2 Frame Slip Buffer
ST-BUS
Interface
RxDLCLK RxDL
BL/FR
BS/LS
OSC1
OSC2
Jitter Attenuator
& Clock Control
Data Link,
RxMF
LOS
RxFP/Rx64kCK
E2o F0b C4b
Figure 1 - Functional Block Diagram
1
Zarlink Semiconductor Inc.
Zarlink, ZL and the Zarlink Semiconductor logo are trademarks of Zarlink Semiconductor Inc.
Copyright 2002-2011, Zarlink Semiconductor Inc. All Rights Reserved.
TTIP
TRING
MT
Loop
RM
Loop
IEEE
1149.1
PL Loop
Line
Driver
Rx Equalizer
& Data Slicer
DSTo
CSTo
Transmit Framing, Error and
Test Signal Generation
ST Loop
Microprocessor
Interface
Tdi
Tdo
Tms
Tclk
Trst
INT/MOT
IRQ
D7~D0
AC4
~AC0
R/W/WR
CS
DS/RD
ST-BUS
Interface
Clock,Data
Recovery
DSTi
CSTi
TAIS
TxMF
Pulse
Generator
TxDL TxDLCLK
RTIP
RRING
MT9075B
Data Sheet
Description
The MT9075B is a single chip device which integrates an advanced PCM 30 framer with a Line Interface Unit (LIU).
The framer interfaces to a 2.048 Mbit/s backplane and provides selectable rate data link access with optional HDLC
controllers for Sa bits and channel 16. The LIU interfaces the framer functions to the PCM 30 transformer-isolated
four wire line.
The MT9075B meets or supports the latest ITU-T Recommendations including G.703, G.704, G.706, G.732, G.775,
G.796, G.823 for PCM 30, and I.431 for ISDN primary rate. It also meets or supports ETSI ETS 300 011, ETS 300
166 and ETS 300 233 as well as BS 6450.
Change Summary
Changes from the August 2005 issue to the August 2011 issue.
Page
1
Item
Ordering Information
Change
Removed leaded packages as per PCN notice.
2
Zarlink Semiconductor Inc.
LOS
VSS
OSC2
OSC1
VSS
VDD
BL/FR
TxDL
TxDLCK
IC
IC
Data Sheet
9
8
7
6
5
4
3
2
1
68
67
66
65
64
63
62
61
DS/RD
DSTi
DSTo
CSTi
CSTo
VDD
MT9075B
CS
RESET
IRQ
D0
D1
D2
D3
VSS
IC
INT/MOT
VDD
D4
D5
D6
D7
R/W/WR
AC0
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
60
59
58
57
56
55
54
53
52
51
50
49
48
47
46
45
44
F0b
C4b
E2o
RxDL
TxMF
RxMF
BS/LS
NC
NC
NC
NC
NC
NC
DS/RD
DSTi
DSTo
CSTi
CSTo
VDD
VSS
OSC2
OSC1
VSS
VDD
BL/FR
TXDL
TCDLCK
IC
NC
IC
LOS
NC
NC
NC
NC
NC
NC
AC1
AC2
AC3
AC4
GNDARx
RTIP
RRING
VDDARx
VDD
VSS
NC
NC
RxDCLK
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
68 PIN PLCC
TAIS
Trst
Tclk
Tms
Tdo
Tdi
GNDATx
TRING
TTIP
VDDATx
VDD
VSS
IC
RxFP/Rx64KCK
80
78
76
74
72
70
68
66
64
62
60
58
56
54
52 50
82
48
84
46
86
44
88
42
100 PIN MQFP (JEDEC MO-112)
90
40
92
38
94
36
96
34
98
32
100
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
NC
NC
NC
NC
NC
NC
NC
AC1
AC2
AC3
AC4
GNDARx
RTIP
RRING
VDARx
VDD
VSS
IC
IC
RXDLCK
RXDL
TxMF
RxMF
BS/LS
NC
NC
NC
NC
NC
NC
NC
NC
CS
RESET
IRQ
D0
D1
D2
D3
VSS
IC
INT/MOT
VDD
D4
D5
D6
D7
R/W/WR
AC0
NC
Figure 2 - Pin Connections
3
Zarlink Semiconductor Inc.
NC
NC
TAIS
Trst
Tclk
Tms
Tdo
Tdi
GNDATx
TRING
TTIP
VDDATx
VDD
VSS
IC
RxFP/Rx64KCK
F0b
C4b
E2o
NC
MT9075B
Data Sheet
Pin Description
Pin #
Name
Description
PLCC MQFP
1
66
OSC1
Oscillator Input. This pin is either connected via a 20.000 MHz crystal to OSC2 where a
crystal is used, or is directly driven when a 20.000 MHz oscillator is employed (see
Figures 6 and 7). CMOS input switching level.
2
67
OSC2
Oscillator Output. Not suitable for driving other devices.
3
68
VSS
Negative Power Supply (Input). Digital ground.
4
69
VDD
Positive Power Supply (Input). Digital supply (+5V  5%).
5
70
CSTo
Control ST-BUS Output. CSTo carries one of the following two serial streams for CAS
and CCS respectively:
(i) A 2.048 Mbit/s ST-BUS status stream which contains the 30 receive signalling nibbles
(ABCDZZZZ or ZZZZABCD). The most significant nibbles of each ST-BUS time slot are
valid and the least significant nibbles of each ST-BUS time slot are tristated when control
bit MSN (page 01H, address 1AH, bit 1) is set to 1. If MSN=0, the position of the valid
and tristated nibbles is reversed.
(ii) A 64 kb/s output when the 64 KHz common channel signalling option is selected
(page 01H, address 1AH, bit 0, 64KCCS =1) for channel 16.
6
71
CSTi
Control ST-BUS Input. CSTi carries one of the following two serial streams for CAS and
CCS respectively:
(i) A 2.048 Mbit/s ST-BUS control stream which contains the 30 transmit signalling
nibbles (ABCDXXXX or XXXXABCD) when page 01H, address 1AH, bit 3, RPSIG=0.
When RPSIG=1 this pin has no function. The most significant nibbles of each ST-BUS
time slot are valid and the least significant nibbles of each ST-BUS time slot are ignored
when control bit MSN (page 01H, address 1AH, bit 1) is set to 1. If MSN=0, the position
of the valid and ignored nibbles is reversed.
(ii) A 64 kb/s input when the 64 KHz common channel signalling option is selected (page
01H, address 1AH, bit 0, 64KCCS =1) for channel 16.
7
72
DSTo
Data ST-BUS Output. A 2.048 Mbit/s serial stream which contains the 30 PCM or
data channels received on the PCM 30 line.
8
73
DSTi
Data ST-BUS Input. A 2.048 Mbit/s serial stream which contains the 30 PCM or data
channels to be transmitted on the PCM 30 line.
9
74
DS/RD
Data/Read Strobe (Input).
In Motorola mode (DS), this input is the active low data strobe of the microprocessor
interface.
In Intel mode (RD), this input is the active low read strobe of the microprocessor
interface.
10
83
CS
Chip Select (Input). This active low input enables the non-multiplexed parallel
microprocessor interface of the MT9075B. When CS is set to high, the
microprocessor interface is idle and all bus I/O pins will be in a high impedance state.
11
84
RESET
RESET (Input). This active low input puts the MT9075B in a reset condition. RESET
should be set to high for normal operation. The MT9075B should be reset after powerup. The RESET pin must be held low for a minimum of 1sec. to reset the device
properly.
4
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Pin Description (continued)
Pin #
Name
Description
PLCC MQFP
12
85
IRQ
Interrupt Request (Output). A low on this output pin indicates that an interrupt request
is presented. IRQ is an open drain output that should be connected to VDD through a pullup resistor. An active low CS signal is not required for this pin to function.
13 16
8689
D0 - D3
Data 0 to Data 3 (Three-state I/O). These signals combined with D4-D7 form the
bidirectional data bus of the microprocessor interface (D0 is the least significant bit).
17
90
VSS
18
91
IC
19
92
20
93
VDD
21 24
9497
D4 - D7
25
98
R/W/WR Read/Write/Write Strobe (Input).
In Motorola mode (R/W), this input controls the direction of the data bus D[0:7] during
a microprocessor access. When R/W is high, the parallel processor is reading data
from the MT9075B. When low, the microprocessor is writing data to the MT9075B.
For Intel mode (WR), this active low write strobe configures the data bus lines as
output.
26 30
99,
8-11
31
12
32
33
13
14
34
15
35
16
VDD
Positive Power Supply (Input). Digital supply (+5V  5%).
36
17
VSS
Negative Power Supply (Input). Digital ground.
37
18
IC
Internal Connection. Must be left open for normal operation.
38
19
IC
Internal Connection. Must be left open for normal operation.
39
20
40
21
RxDL
Receive Data Link (Output). A 2.048 Mbit/s data stream containing received line data
after HDB3 decoding. This data is clocked out with the rising edge of E2o.
41
22
TxMF
Transmit Multiframe Boundary (Input). An active low input used to set the transmit
multiframe boundary (CAS or CRC multiframe). The MT9075B will generate its own
multiframe if this pin is held high. This input is usually pulled high for most applications.
Negative Power Supply (Input). Digital ground.
Internal Connection. Tie to VSS (Ground) for normal operation.
INT/MOT Intel/Motorola Mode Selection (Input). A high on this pin configures the processor
interface for the Intel parallel non-multiplexed bus type. A low configures the processor
interface for the Motorola parallel non-multiplexed type.
AC0 AC4
Positive Power Supply (Input). Digital supply (+5V  5%).
Data 4 to Data 7 (Three-state I/O). These signals combined with D0-D3 form the
bidirectional data bus of the microprocessor interface (D7 is the most significant bit).
Address/Control 0 to 4 (Inputs). Address and control inputs for the microprocessor
interface. AC0 is the least significant input.
GNDARx Receive Analog Ground (Input). Analog ground for the LIU receiver.
RTIP
RRING
Receive TIP and RING (Inputs). Differential inputs for the receive line signal - must be
transformer coupled (See Figure 4).
VDDARx Receive Analog Power Supply (Input). Analog supply for the LIU receiver (+5V  5%).
RxDLCLK Receive Data Link Clock (Output). A gapped clock signal derived from a 2.048 Mbit/s
clock, available for an external device to clock in RxDL data (at 4, 8, 12, 16 or 20 kHz) on
the rising edge.
5
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Pin Description (continued)
Pin #
Name
Description
PLCC MQFP
42
23
RxMF
Receive Multiframe Boundary (Output). An output pulse delimiting the received
multiframe boundary. The next frame output on the data stream (DSTo) is basic frame
zero on the PCM 30 link. This receive multiframe signal can be related to either the
receive CRC multiframe (page 01H, address 10H, bit 6, MFSEL=1) or the receive
signalling multiframe (MFSEL=0).
43
24
BS/LS
System Bus Synchronous/Line Synchronous Selection (Input). If high, C4b and F0b
will be inputs; if low, C4b and F0b will be outputs.
44
32
E2o
2.048 MHz Extracted Clock (Output). The clock extracted from the received signal
and used internally to clock in data received on RTIP and RRING.
45
33
C4b
4.096 MHz System Clock (Input/Output). C4b is the clock for the ST-BUS sections and
transmit serial PCM data of the MT9075B. In the free-run (BL/FR=0) or line synchronous
mode (BL/FR=1 and BS/LS=0) this signal is an output, while in the system bus
synchronous mode (BS/LS=1) this signal is an input clock.
46
34
F0b
Frame Pulse (Input/Output). This is the ST-BUS or GCI frame synchronization
signal, which delimits the 32 channel frame of CSTi, CSTo, DSTi, DSTo and the
PCM30 link. In the free-run (BL/FR=0) or loop synchronous mode (BL/FR=1 and
BS/LS=0) this signal is an output, while in the Bus Synchronous mode (BL/FR=1 and
BS/LS=0) this signal is an input. The GCI/ST-BUS selection is made under software
control. Page 02H, address 13H, bit 0, GCI/ST=1 selects GCI frame pulse; GCI/ST=0
selects ST-BUS.
47
35
48
36
IC
49
37
VSS
Negative Power Supply (Input). Digital ground.
50
38
VDD
Positive Power Supply (Input). Digital supply (+5V  5%).
51
39
VDDATx Transmit Analog Power Supply (Input). Analog supply for the LIU transmitter (+5V 
5%).
52
53
40
41
TTIP
TRING
54
42
GNDATx Transmit Analog Ground (Input). Analog ground for the LIU transmitter.
55
43
Tdi
IEEE 1149.1 Test Data Input. If not used, this pin should be pulled high.
56
44
Tdo
IEEE 1149.1 Test Data Output. If not used, this pin should be left unconnected.
57
45
Tms
IEEE 1149.1 Test Mode Selection (Input). If not used, this pin should be pulled high.
58
46
Tclk
IEEE 1149.1 Test Clock Signal (Input). If not used, this pin should be pulled high.
59
47
Trst
IEEE 1149.1 Reset Signal (Input). If not used, this pin should be held low.
RxFP/Rx6 Receive Frame Pulse/Receive CCS Clock (Output). An 8 kHz pulse signal, which is
4KCK low for one extracted clock period. This signal is synchronized to the receive PCM 30
basic frame boundary.
When 64KCCS (page 01H, address 1AH, bit 0) is set to 1, this pin outputs a 64 kHz clock
derived by dividing down the extracted 2.048 MHz clock. This clock is used to clock CCS
data out of pin CSTo in the CCS mode.
Internal Connection. Must be left open for normal operation.
Transmit TIP and RING (Outputs). Differential outputs for the transmit line signal - must
be transformer coupled (See Figure 4).
6
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Pin Description (continued)
Pin #
Name
Description
PLCC MQFP
60
48
TAIS
Transmit Alarm Indication Signal (Input). An active low on this input causes the
MT9075B to transmit an AIS (all ones signal) on TTIP and TRING pins. TAIS should be
set to high for normal data transmission.
61
57
LOS
Loss of Signal or Synchronization (Output). When high, and LOS/LOF (page 02H
address 13H bit 2) is zero, this signal indicates that the receive portion of the MT9075B
is either not detecting an incoming signal (bit LLOS on page 03H address 18H is one) or
is detecting a loss of basic frame alignment condition (bit SYNC on page 03H address
10H is one). If LOS/LOF=1, a high on this pin indicates a loss of signal condition.
62
58
IC
Internal Connection. Tie to VSS (Ground) for normal operation.
59
NC
No Connection. Leave open for normal operation.
63
60
IC
Internal Connection. Tie to VSS (Ground) for normal operation.
64
61
65
62
TxDL
Transmit Data Link (Input). An input serial stream of transmit data link data at 4, 8, 12,
16 or 20 kbit/s composed of 488ns-wide bit cells which are multiplexed into selected
national bits of the PCM 30 transmit signal.
66
63
BL/FR
Bus or Line/Freerun (Input). If this pin is set to high, the MT9075B is in the System Bus
or Line Synchronous mode depending on the BS/LS pin. If low, the MT9075B is in the
free run mode.
67
64
VDD
Positive Power Supply (Input). Digital supply (+5V  5%).
68
65
VSS
Negative Power Supply (Input). Digital ground.
1-7,
25-31,
49-56,
75-82,
100
NC
No Connection. Leave open for normal operation.
TxDLCLK Transmit Data Link Clock (Output). A gapped clock signal derived from a gated 2.048
Mbit/s clock for transmit data link at 4, 8, 12, 16 or 20 kHz. The transmit data link data
(TxDL) is clocked in on the rising edge of TxDLCLK. TxDLCLK can also be used to clock
DL data out of an external serial controller.
Device Overview
The MT9075B is an advanced PCM 30 framer with an on-chip Line Interface Unit (LIU) that meets or supports the
latest ITU-T Recommendations for PCM 30 and ISDN primary rate including G.703, G.704, G.706, G.775, G.796,
G.732, G.823 and I.431. It also meets or supports the layer 1 requirements of ETSI ETS 300 011, ETS 300 166,
ETS 300 233 and BS6450.
The Line Interface Unit (LIU) of the MT9075B interfaces the digital framer functions to the PCM 30 transformerisolated four wire line. The transmit portion of the MT9075B LIU consists of a digital buffer, a digital-to-analog
converter and a differential line driver. The receiver portion of the LIU consists of an input signal peak detector, an
optional two-stage equalizer, a smoothing filter, data and clock slicers and a clock extractor. The optional equalizer
allows for error free reception of data with a line attenuation of up to 20 dB.
The LIU also contains a Jitter Attenuator (JA), which can be configured to either the transmit or receive path. The
JA will attenuate jitter from 2.5 Hz and roll-off at a rate of 20 dB/decade. Its intrinsic jitter is less than 0.02 UI.
7
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
The digital portion of the MT9075B connects an incoming stream of time multiplexed PCM channels (at
2.048 Mbit/s) to the transmit payload of the E1 trunk, while the receive payload is connected to the ST-BUS or GCI
2.048 Mbit/s backplane bus for both data and signalling. Control, reporting and conditioning of the line is
implemented via a parallel microprocessor interface. The MT9075B framing algorithm allows automatic
interworking between CRC-4 and non-CRC-4 interfaces.
The Sa bits can be accessed by the MT9075B in the following four ways:
•
Single byte registers;
•
Five byte transmit and receive national bit buffers;
•
Data link pins TxDL, RxDL, RxDLCLK and TxDLCLK;
•
HDLC Controller with a 128 byte FIFO.
The MT9075B operates in either termination or transparent modes selectable via software control. In the
termination mode the CRC-4 calculation is performed as part of the framing algorithm. In the transmit transparent
mode, no framing or signalling is imposed on the data transmit from DSTi on the line. In addition, the MT9075B
optionally allows the data link maintenance channel to be modified and updates the CRC-4 remainder bits to reflect
the modification. All channel, framing and signalling data passes through the device unaltered. This is useful for
intermediate point applications of a PCM 30 link where the data link data is modified, but the error information
transported by the CRC-4 bits must be passed to the terminating end. In the receive transparent mode, the
received line data is channelled to DSTo with framing operations disabled, consequently, the data passes through
the slip buffer and drives DSTo with an arbitrary alignment.
The MT9075B has a comprehensive suite of status, alarm, performance monitoring and reporting features. These
include counters for BPVs, CRC errors, E-bit errors, errored frame alignment signals, BERT, and RAI and
continuous CRC errors. Also, included are transmission error insertion for BPVs, CRC-4 errors, frame and nonframe alignment signal errors, payload errors and loss of signal errors.
A complete set of loopback functions is provided, which includes digital, remote, ST-BUS, payload, metallic, local
and remote time slot.
The MT9075B also contains a comprehensive set of maskable interrupts and an interrupt vector function. Interrupt
sources consist of synchronization status, alarm status, counter indication and overflow, timer status, slip indication,
maintenance functions and receive channel associated signalling bit changes. A special set of maskable interrupts
have been included for sensing changes in the state of the national use bits and nibbles, in compliance to emerging
ETS requirements.
The MT9075B system timing may be slaved to the line, operated in freerun mode, or controlled by an external
timing source.
Functional Description
MT9075B Line Interface Unit (LIU)
Receiver
The receiver portion of the MT9075B LIU consists of an input signal peak detector, an optional two-stage equalizer,
a smoothing filter, adaptive threshold comparators, data and clock slicers, and a clock extractor. Receive
equalization gain can be set via software control or it can be determined automatically by the peak detectors.
The output of the receive equalizer is conditioned by a smoothing filter and is passed on to the clock and data slicer.
The clock slicer output signal drives a phase locked loop, which generates the extracted clock (E2o). This extracted
clock is used to sample the output of the data comparator.
The LOS output pin (pin 61 in PLCC, pin 57 in MQFP) is user selectable, by setting control bit LOS/LOF (page 02H,
register 13H, bit 2), to indicate a loss of signal or loss of basic frame synchronization condition. In addition, a status
8
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
bit, LLOS (bit 4 in page 3, register 18H) is provided to indicate the presence of a loss signal condition. The
occurrence of a loss signal condition is defined as per I.431, i.e., when the incoming signal amplitude is more than
20 dB below the nominal amplitude for a time duration of at least 1 ms.
The receive LIU circuit requires a terminating resistor of either 120  or 75  across the device side of the
receive1:1 transformer as shown in Figure 4. The return loss of the receiver, complying with G.703, is greater
than:
•
12 dB from 51 kHz to 102 kHz;
•
18 dB from 102 kHz to 2048 kHz;
•
14 dB from 2048 kHz to 3072 kHz.
The jitter tolerance of the MT9075B clock extractor circuit exceeds the requirements of G.823 (Figure 3).
Transmitter
The MT9075B differential line driver is designed to drive a 1:2 step-up transformer (see Figure 4). A 0.68 uF
capacitor is required between the TTIP and the transmit transformer. Resistors RT (as shown in Figure 4) are for
termination for transmit return loss. The values of RT may be optimized for 120  lines, 75  lines or set at an
intermediary value to serve both applications. Program the Transmit Pulse Control Word (address 1FH page 1) to
adjust the pulse amplitude accordingly. Alternatively, the pulse level and shape may be discretely programmed by
writing to the Customer Pulse Level registers (addresses 1CH to 1FH, page 2) and setting the Custom Transmit
Pulse bit high (bit 3 of the Transmit Pulse Control Word).
Peak to Peak
Jitter Amplitude
(log scale)
18UI
MT9075B
Tolerance
1.5UI
0.2UI
Jitter Frequency
(log scale)
1.667Hz
20Hz
2.4kHz 18kHz 100kHz
Figure 3 - Typical Jitter Tolerance
9
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Tx
0.68uF
RT
1:2
TTIP
TRING
RT
MT9075B
1:1
RTIP
RRING
120

Rx
Figure 4 - Analog Line Interface
The template for the transmitted pulse, as specified in G703, is shown in Figure 5. The nominal peak voltage of a
mark is 3 volts for 120  twisted pair applications and 2.37 volts for 75  coax applications. The ratio of the
amplitude of the transmit pulses generated by TTP and TRING is between 0.95 and 1.05.
Percentage of
Nominal Peak
269nS
120
110
100
90
80
244nS
194nS
50
10
0
-10
-20
Nominal Pulse
219nS
488nS
Figure 5 - Pulse Template (G.703)
10
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Transformer Recommendation
Table 1 shows a list of recommended transformers for the MT9075B line interface.
Manufacturer
For Tx
For Rx
Filtran
5721-1
5721-2
Pulse Engineering
PE-65351
PE-64934
Midcom
50027
OSEC
02934/A
50026
02935/A
Table 1 - Transformer Manufacturers and Part Numbers
Timing Source
The MT9075B can use either a clock or crystal, connecting to pins OSC1 and OSC2, as the reference timing
source.
Figure 6 shows a 20 MHz clock oscillator, with 50 ppm tolerance, directly connected to the OSC1 pin of the
MT9075B.
+5V
MT9075B
OSC1
20MHz
Vdd
OUT
GND
.1F
OSC2
(open)
Figure 6 - Clock Oscillator Circuit
Alternatively, a crystal oscillator may be used. A complete oscillator circuit made up of a crystal, resistors and
capacitors is shown in Figure 7. The crystal specification is as follows.
Frequency:
Tolerance:
Oscillation Mode:
Resonance Mode:
Load Capacitance:
Maximum Series Resistance:
Approximate Drive Level:
20 MHz
50 ppm
Fundamental
Parallel
32 pF
35 
1 mW
11
Zarlink Semiconductor Inc.
MT9075B
MT9075B
Data Sheet
20MHz
OSC1
56pF
39pF
1M
1H*
100
OSC2
Note: the 1H inductor is optional
Figure 7 - Crystal Oscillator Circuit
Jitter Attenuator (JA)
The MT9075B Jitter Attenuator (JA), which consists of a Phase Locked Loop (PLL) and data FIFO, can be used on
either the transmit or receive side of the interface.
On the transmit side the C4b signal clocks the data into the FIFO, the PLL de-jitters the C4b clock and the resulting
clean C4b signal clocks the data out of the FIFO.
When the JA is selected on the receive side, the extracted clock signal clocks the data into the FIFO. The same
clock feeds the PLL and the resulting de-jittered clock is used to clock the data out of the FIFO.
The JA meets the jitter transfer characteristics as proposed by G.823 and the relevant recommendations as
shown in Figure 8. The JA FIFO depth can be selected to be from 16 to 128 words deep, in multiples of 16 (2bit) words. Its read pointer can be centered by changing the JFC bit (address 18H of page 02H) to provide
maximum jitter tolerance. If the read pointer should come within 4 bits of either end of the FIFO, the read clock
frequency will be increased or decreased by 0.0625 UI to correct the situation. The maximum time needed to
centre is Tmax= 3904Depth ns, where Depth is the selected JA FIFO depth. During this time the JA will not
attenuate jitter.
To ensure normal operation, the JA FIFO depth should be set in software to be larger than the anticipated maximum
UI of input jitter.
Clock Jitter Attenuation Modes
MT9075B has three basic jitter attenuation modes of operation, selected by the BS/LS and BL/FR control pins.
•
System Bus Synchronous Mode
•
Line Synchronous Mode
•
Free-run mode
12
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
dB
JITTER ATTENUATION (dB)
0.5
0
-20 dB/decade
-19.5
10
40
400
10K
Figure 8 - Typical Jitter Attenuation Curve
Mode Name
BS/LS
BL/FR
JAS
JAT/JAR
Note
SysBusSync1
1
1
1
1
JA on Tx side; No JA on Rx side
SysBusSync2
1
1
1
0
JA on Rx side; No JA on Tx side
SysBusSync3
1
1
0
x
No JA on Tx or Rx side
Line
Synchronous
0
1
x
x
By default, JA is on the receive side.
Controls bits need not be selected.
Free-Run
x
0
x
x
In free-run mode JA will be automatically
disconnected
Table 2 - Selection of Clock Jitter Attenuation Modes
Depending on the mode selected, the Jitter Attenuator (JA) can attenuate either transmit clock jitter or receive
clock jitter, or be disconnected. Control bits JAS, JAT/JAR (address 18H of page 02H) determine the JA
selection under certain modes. Table 2 shows the configuration of related control pins and control bits required
to place the MT9075B in the appropriate jitter attenuation mode.
Referring to the mode names given in Table 2, the basic operation of the jitter attenuation modes is summarized
Frequency (Hz)
as follows:
•
In SysBusSync (1-3) modes, pins C4b and F0b are always configured as inputs, while in the Line
Synchronous and Free-Run modes C4b and F0b are configured as outputs.
•
In SysBusSync1 mode, an external clock is applied to C4b. The applied clock is dejittered by the internal
PLL before being used to transmit data. The clock extracted (with no jitter attenuation performed) from the
receive data can be monitored on pin E2o.
13
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
•
In SysBusSync2 mode, the clock applied to pin C4b is assumed to be jitter-free and is directly used to
transmit data. The internal PLL is used to dejitter the extracted receive clock. The dejittered receive clock is
output on pin E2o.
•
In SysBusSync3 mode, no jitter attenuation is applied to either the transmit or receive clocks. The transmit
data is synchronized to clock applied to pin C4b. The extracted receive clock is not dejittered and is supplied
directly to the E2o output.
•
In Line Synchronous mode, the clock extracted from the receive data is dejittered using the internal PLL and
then output on pin C4b. Pin E2o provides the extracted receive clock before it has been dejittered. The
transmit data is synchronous to the clean receive clock.
•
In Free-Run mode the transmit data is synchronized to the internally generated clock. The internal clock is
output on pin C4b. The clock signal extracted from the receive data is not dejittered and is output directly on
pin E2o.
The PCM 30 Interface
PCM 30 (E1) basic frames are 256 bits long and are transmitted at a frame repetition rate of 8000 Hz, which
results in an aggregate bit rate of 256 bits x 8000/sec = 2.048 Mbits/sec. The actual bit rate is 2.048 Mbits/sec
+/-50 ppm encoded in HDB3 format. The HDB3 control bit (page 01H, address 15H, bit 5) selects either HDB3
encoding or alternate mark inversion (AMI) encoding. Basic frames are divided into 32 time slots numbered 0 to
31, see Figure 30. Each time slot is 8 bits in length and is transmitted most significant bit first (numbered bit 1). This
results in a single time slot data rate of 8 bits x 8000/sec. = 64 kbits/sec.
It should be noted that the Zarlink ST-BUS also has 32 channels numbered 0 to 31, but the most significant bit
of an eight bit channel is numbered bit 7 (see Zarlink Application Note MSAN-126). Therefore, ST-BUS bit 7 is
synonymous with PCM 30 bit 1; bit 6 with bit 2: and so on (Figure 31).
PCM 30 time slot 0 is reserved for basic frame alignment, CRC-4 multiframe alignment and the communication
of maintenance information. In most configurations time slot 16 is reserved for either Channel Associated Signalling
(CAS or ABCD bit signalling) or Common Channel Signalling (CCS). The remaining 30 time slots are called
channels and carry either PCM encoded voice signals or digital data. Channel alignment and bit numbering is
consistent with time slot alignment and bit numbering. However, channels are numbered 1 to 30 and relate to time
slots as per Table 3.
PCM 30
Timeslot
0
1 2 3...15
16
17 18 19...31
Voice/Data
Channels
x
1 2 3...15
x
16 17 18...30
Table 3 - Time Slot to Channel Relationship
Basic Frame Alignment
Time slot 0 of every basic frame is reserved for basic frame alignment and contains either a Frame Alignment
Signal (FAS) or a Non-Frame Alignment Signal (NFAS). FAS and NFAS occur in time slot zero of consecutive basic
frames as shown in Table 7. Bit two is used to distinguish between FAS (bit two = 0) and NFAS (bit two = 1).
Basic frame alignment is initiated by a search for the bit sequence 0011011 which appears in the last seven bit
positions of the FAS, see the Frame Algorithm section. Bit position one of the FAS can be either a CRC-4 remainder
bit or an international usage bit.
Bits four to eight of the NFAS (i.e., Sa4 - Sa8) are additional spare bits which may be used as follows:
•
Sa4 to Sa8 may be used in specific point-to-point applications (e.g. transcoder equipments conforming to
G.761).
•
Sa4 may be used as a message-based data link for operations, maintenance and performance monitoring.
14
Zarlink Semiconductor Inc.
MT9075B
•
Data Sheet
Sa5 to Sa8 are for national usage.
A maintenance channel or data link at 4,8,12,16,or 20 kHz for selected Sa bits is provided by the MT9075B to
implement these functions. Note that for simplicity all Sa bits including Sa4 are collectively called national bits
throughout this document.
Bit three (designated as “A”), the Remote Alarm Indication (RAI), is used to indicate the near end basic frame
synchronization status to the far end of a link. Under normal operation, the A (RAI) bit should be set to 0, while in
alarm condition, it is set to 1.
Bit position one of the NFAS can be either a CRC-4 multiframe alignment signal, an E-bit or an international usage
bit. Refer to an approvals laboratory and national standards bodies for specific requirements.
CRC-4 Multiframing
The primary purpose for CRC-4 multiframing is to provide a verification of the current basic frame alignment,
although it can also be used for other functions such as bit error rate estimation. The CRC-4 multiframe consists of
16 basic frames numbered 0 to 15, and has a repetition rate of 16 frames X 125 microseconds/frame = 2 msec.
CRC-4 multiframe alignment is based on the 001011 bit sequence, which appears in bit position one of the first six
NFASs of a CRC-4 multiframe.
The CRC-4 multiframe is divided into two submultiframes, numbered 1 and 2, which are each eight basic frames or
2048 bits in length.
The CRC-4 frame alignment verification functions as follows. Initially, the CRC-4 operation must be activated
and CRC-4 multiframe alignment must be achieved at both ends of the link. At the local end of a link, all the bits
of every transmit submultiframe are passed through a CRC-4 polynomial (multiplied by X4 then divided by X4 +
X + 1), which generates a four bit remainder. This remainder is inserted in bit position one of the four FASs of
the following submultiframe before it is transmitted (see Table 7).
The submultiframe is then transmitted and, at the far end, the same process occurs. That is, a CRC-4 remainder is
generated for each received submultiframe. These bits are compared with the bits received in position one of the
four FASs of the next received submultiframe. This process takes place in both directions of transmission.
When more than 914 CRC-4 errors (out of a possible 1000) are counted in a one second interval, the framing
algorithm will force a search for a new basic frame alignment. See Frame Algorithm section for more details.
The result of the comparison of the received CRC-4 remainder with the locally generated remainder will be
transported to the far end by the E-bits. Therefore, if E1 = 0, a CRC-4 error was discovered in a submultiframe 1
received at the far end; and if E2 = 0, a CRC-4 error was discovered in a submultiframe 2 received at the far end.
No submultiframe sequence numbers or re-transmission capabilities are supported with layer 1 PCM 30 protocol.
See ITU-T G.704 and G.706 for more details on the operation of CRC-4 and E-bits.
There are two CRC multiframe alignment algorithm options selected by the AUTC control bit (address 11H, page
01H). When AUTC is zero and CSYN is zero, automatic CRC-to-non-CRC interworking is selected, if CRC-4
multiframe alignment is not found in 400 msec, the status bit CRCIWK (page 03H, address 10H) is set low and no
further attempt to achieve CRC-4 synchronization is made as long as the device remains in terminal frame
synchronization. When AUTC is one and CSYN is zero, a reframe will be initiated every 8 msec if the MT9075B
achieves terminal frame synchronization, but fails to achieve CRC-4 synchronization. In this case, if ARAI is low,
RAI will flicker high with every reframe. If CRC MFAI is unsuccessful after 400ms, RAI will stay high continuously.
The control bit for transmit E bits (TE, bit 4 at address 16H of page 01H) will have the same function in both states
of AUTC. That is, when CRC-4 synchronization is not achieved the state of the transmit E-bits will be the same as
the state of the TE control bit. When CRC-4 synchronization is achieved the transmit E-bits will function as per ITUT G.704. Table 4 outlines the operation of the AUTC, ARAI and TALM control bits of the MT9075B.
15
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
AUTC
ARAI
TALM
Description
0
0
x
Automatic CRC-interworking is activated. If no valid CRC MFAS is
being received, transmit RAI will flicker high with every reframe (8
msec.), this cycle will continue for 400 msec., then transmit RAI will be
low continuously. The device will stop searching for CRC MFAS,
continue to transmit CRC-4 remainders, stop CRC-4 processing
indicate CRC-to-non-CRC operation and transmit E-bits to be the same
state as the TE control bit (page 01H, address 16H).
0
1
0
Automatic CRC-interworking is activated. Transmit RAI is low
continuously upon loss of synchronization.
0
1
1
Automatic CRC-interworking is activated. Transmit RAI is high
continuously upon loss of synchronization.
1
0
x
Automatic CRC-interworking is de-activated. If no valid CRC MFAS is
being received, transmit RAI flickers high with every reframe (8 msec.),
this cycle continues for 400 msec., then transmit RAI becomes high
continuously. The device continues to search for CRC MFAS and
transmit E-bits are the same state as the TE control bit. When CRCSYN
= 0, the CRC MFAS search is terminated and the transmit RAI goes
low.
1
1
0
Automatic CRC-interworking is de-activated. Transmit RAI is low
continuously upon loss of synchronization.
1
1
1
Automatic CRC-interworking is de-activated. Transmit RAI is high
continuously upon loss of synchronization.
Table 4 - Operation of AUTC, ARAI and TALM Control Bits
CAS Signalling Multiframing
The purpose of the signalling multiframing algorithm is to provide a scheme that will allow the association of a
specific ABCD signalling nibble with the appropriate PCM 30 channel. Time slot 16 is reserved for the
communication of Channel Associated Signalling (CAS) information (i.e., ABCD signalling bits for up to 30
channels). Refer to ITU-T G.704 and G.732 for more details on CAS multiframing requirements.
A CAS signalling multiframe consists of 16 basic frames (numbered 0 to 15), which results in a multiframe repetition
rate of 2 msec. It should be noted that the boundaries of the signalling multiframe may be completely distinct from
those of the CRC-4 multiframe. CAS multiframe alignment is based on a multiframe alignment signal (a 0000 bit
sequence), which occurs in the most significant nibble of time slot 16 of basic frame 0 of the CAS multiframe. Bit 6
of this time slot is the multiframe alarm bit (usually designated Y). When CAS multiframing is acquired on the
receive side, the transmit Y-bit is zero; when CAS multiframing is not acquired, the transmit Y-bit is one. Bits 5, 7
and 8 (usually designated X) are spare bits and are normally set to one if not used.
Time slot 16 of the remaining 15 basic frames of the CAS multiframe (i.e., basic frames 1 to 15) are reserved for the
ABCD signalling bits for the 30 payload channels. The most significant nibbles are reserved for channels 1 to 15
and the least significant nibbles are reserved for channels 16 to 30. That is, time slot 16 of basic frame 1 has ABCD
for channel 1 and 16, time slot 16 of basic frame 2 has ABCD for channel 2 and 17, through to time slot 16 of basic
frame 15 has ABCD for channel 15 and 30.
16
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
MT9075B Access and Control
Register Access
The control and status of the MT9075B is achieved through a non-multiplexed parallel microprocessor port. The
parallel port may be configured for Motorola style control signals (by setting pin INT/MOT low) or Intel style control
signals (by setting pin INT/MOT high).
The controlling microprocessor gains access to specific registers of the MT9075B through a two step process. First,
writing to the internal Command/Address Register (CAR) selects one of the 18 pages of control and status registers
(CAR address: AC4 = 0, AC3-AC0 = don't care, CAR data D7 - D0 = page number). Second, each page has a
maximum of 16 registers that are addressed on a read or write to a non-CAR address (non-CAR: address AC4 = 1,
AC3-AC0 = register address, D7-D0 = data). Once a page of memory is selected, it is only necessary to write to the
CAR when a different page is to be accessed. See Figures 11 and 12 for timing requirements.
Please note that for microprocessors with read/write cycles less than 200 ns, a wait state or a dummy operation (for
C programming) between two successive read/write operations to the HDLC FIFO is required.
Table 5 associates the MT9075B control and status pages with access and page descriptions.
Page Address
D7 - D0
00000001 (01H)
Register Description
Processor
Access
ST-BUS
Access
Master
Control
R/W
00000100 (04H)
Master
Status
R/W
---
00000101 (05H)
Per Channel Transmit Signalling
R/W
CSTi
00000110 (06H)
Per Channel Receive Signalling
R
CSTo
00000111 (07H)
00001000 (08H)
Per Time Slot
Control
00001001 (09H)
1 Second Status
00001010 (0AH)
unused
00001011 (0BH)
HDLC0 Control and Status (TS 0)
R/W
---
00001100 (0CH)
HDLC1 Control and Status (TS 16)
R/W
---
00001101 (0DH)
Transmit National Bit Buffer
R/W
---
00001110 (0EH)
Receive National Bit Buffer
R
---
00001111 (0FH)
Tx message mode Buffer 0
R/W
---
00010000 (10H)
Tx message mode Buffer 1
R/W
---
00010001 (11H)
Rx message mode Buffer 0
R/W
---
00010010 (12H)
Rx message mode Buffer 1
R/W
---
00000010 (02H)
00000011 (03H)
R/W
--
R
R/W
R/W
---
R
-----
Table 5 - Register Summary
ST-BUS Streams
The ST-BUS stream can also be used to access channel associated signalling nibbles. CSTo contains the received
channel associated signalling bits (e.g., ITU-T R1 and R2 signalling), and when control bit RPSIG (page 01H,
address 1AH) is set to 0, CSTi is used to control the transmit channel associated signalling. The DSTi and DSTo
streams contain the transmit and receive voice and digital data.
17
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Identification Code
The MT9075B shall be identified by the code 10101010, read from the identification code status register (page 03H,
address 1FH).
Reset Operation (Initialization)
The MT9075B can be reset using the hardware RESET pin (pin 11 in PLCC, pin 84 in MQFP, see pin description
for external reset circuit requirements) or the software reset bit RST (page 01H, address 11H). When the device
emerges from its reset state it will begin to function with the default settings described in Table 6. A reset
operation takes 1 full frame (125 us) to complete.
Function
Status
Mode
Termination
Loopbacks
Deactivated
Transmit FAS
Cn0011011
Transmit non-FAS
1/Sn1111111
Transmit MFAS (CAS)
00001111
Data Link
Deactivated
CRC Interworking
Activated
Signalling
CAS Registers
ABCD Bit Debounce
Deactivated
Interrupts
Interrupt Mask Word
Zero unmasked, all
others masked;
interrupts not suspended
RxMF Output
Signalling Multiframe
Error Insertion
Deactivated
HDLCs
Deactivated
Counters
Cleared
Tx Message Buffer
All locations set to 54H
Per Time Slot Control
Buffer
All locations cleared
Table 6 - Reset Status
Transmit AIS Operation
The pin TAIS (Transmit AIS, pin 60 in PLCC, pin 48 in MQFP) allows an all ones signal to be transmitted from the
point of power-up without the need to write any control registers. During this time the IRQ pin is tristated. After the
interface has been initialized normal operation can take place by making TAIS high.
National Bit Buffers
Table 7 shows the contents of the transmit and receive Frame Alignment Signals (FAS) and Non-frame Alignment
Signals (NFAS) of time slot zero of a PCM 30 signal. Even numbered frames (CRC Frame # 0, 2, 4,...) are FASs
and odd numbered frames (CRC Frame # 1, 3, 5,...) are NFASs. The bits of each channel are numbered 1 to 8, with
bit 1 being the most significant and bit 8 the least significant.
18
Zarlink Semiconductor Inc.
MT9075B
Sub Multi Frame 1
CR
C
CRC
Frame/
Type
PCM 30 Channel Zero
1
2
3
4
5
6
7
8
0/FAS
C
0
0
1
1
0
1
1
1/NFAS
0
1
A
2/FAS
C
0
0
3/NFAS
0
1
A
4/FAS
C
0
0
5/NFAS
1
1
A
6/FAS
C
0
0
7/NFAS
0
1
A
8/FAS
C
0
0
9/NFAS
1
1
A
0
0
1
A
0
0
1
A
0
0
1
A
10/FAS
Sub Multi Frame 2
Data Sheet
11/NFA
S
12/FAS
13/NFA
S
14/FAS
15/NFA
S
1
2
3
4
1
C
2
1
C
3
E
1
C
4
E
2
S
S
S
S
S
a4
a5
a6
a7
a8
1
1
0
1
1
S
S
S
S
S
a4
a5
a6
a7
a8
1
1
0
1
1
S
S
S
S
S
a4
a5
a6
a7
a8
1
1
0
1
1
S
S
S
S
S
a4
a5
a6
a7
a8
1
1
0
1
1
S
S
S
S
S
a4
a5
a6
a7
a8
1
1
0
1
1
S
S
S
S
S
a4
a5
a6
a7
a8
1
1
0
1
1
S
S
S
S
S
a4
a5
a6
a7
a8
1
1
0
1
1
S
S
S
S
S
a4
a5
a6
a7
a8
Table 7 - FAS and NFAS Structure
indicates position of CRC-4 multiframe alignment signal.
Table 8 illustrates the organization of the MT9075B transmit and receive national bit buffers. Each row is an
addressable byte of the MT9075B national bit buffer, and each column contains the national bits of an odd
numbered frame of each CRC-4 Multiframe. The transmit and receive national bit buffers are located at page 0DH
and 0EH respectively.
19
Zarlink Semiconductor Inc.
MT9075B
Add
ress
able
Byte
s
Data Sheet
Frames 1, 3, 5, 7, 9, 11, 13 & 15 of a CRC-4
Multiframe
F1
F3
F5
F7
F9
F1
1
F1
3
F1
5
NB
B0
Sa4
Sa4
Sa4
Sa4
Sa4
Sa4
Sa4
Sa4
NB
B1
Sa5
Sa5
Sa5
Sa5
Sa5
Sa5
Sa5
Sa5
NB
B2
Sa6
Sa6
Sa6
Sa6
Sa6
Sa6
Sa6
Sa6
NB
B3
Sa7
Sa7
Sa7
Sa7
Sa7
Sa7
Sa7
Sa7
NB
B4
Sa8
Sa8
Sa8
Sa8
Sa8
Sa8
Sa8
Sa8
Table 8 - MT9075B National Bit Buffers
Note that the Data Link (DL) pin functions, if selected, override the transmit national bit buffer function.
The CRC-4 Alignment status CALN (page 03H, address 12H) and maskable interrupt CALNI (page 01H, address
1DH) indicate the beginning of every received CRC-4 multiframe.
Maskable interrupts are available for change of state of Sa5 bits or change of state of Sa6 nibbles. By writing the
proper control bits, an interrupt can be generated on a change of state of any Sa bit (except Sa4 - normally reserved
for the data link), or any nibbles for Sa5 through Sa8. See the description of page 01H, address 19H for more details.
In addition, the transparent transmission of channel 0 is supported to meet the ETS requirement. Selectable on a bit
by bit basis, Sa bits in channel 0 DSTi data can be programmed using register 17H of page 01H to be sent
transparently onto the line.
Data Link Operation
Timeslot 0
The MT9075B has a user defined 4, 8, 12, 16 or 20 kbit/s data link for transport of maintenance and performance
monitoring information across the PCM 30 link. This channel functions using the Sa bits (Sa4~Sa8) of the PCM 30
timeslot zero non-frame alignment signal (NFAS). Since the NFAS is transmitted every other frame - a periodicity of
250 microseconds - the aggregate bit rate is a multiple of 4 kb/s. As there are five Sa bits independently available
for this data link, the bit rate will be 4, 8, 12, 16 or 20 kb/s, depending on the bits selected for the Data Link (DL).
The Sa bits used for the DL are selected by setting the appropriate bits, Sa4~Sa8, to one in the Data Link Select
Word (page 01H, address 10H, bits 4-0). Access to the DL is provided by pins TxDLCLK, TxDL, RxDLCLK and
RxDL, which allow easy interfacing to an external controller.
Data to be transmit onto the line in the Sa bit position is clocked in from the TxDL pad (pin 65 in PLCC, pin 62 in
MQFP) with the clock TxDLCLK (pin 64 in PLCC, pin 61 in MQFP). Although the aggregate clock rate equals the bit
rate, it has a nominal pulse width of 244 ns, and it clocks in the TxDL as if it were a 2.048 Mb/s data stream. The
clock can only be active during bit times 4 to 0 of the STBUS frame. The TxDL input signal is clocked into the
MT9075B by the rising edge of TxDLCLK. If bits are selected to be a part of the DL, all other programmed functions
for those Sa bit positions are overridden.
The RxDLCLK signal (pin 39 in PLCC, pin 20 in MQFP) is derived from the receive extracted clock and is
aligned with the receive data link output RxDL. The HDB3 decoded receive data, at 2.048 Mbit/s, is clocked out
20
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
of the device on pin RxDL (pin 40 in PLCC, pin 21 in MQFP). In order to facilitate the attachment of this data
stream to a Data Link controller, the clock signal RxDLCLK consists of positive pulses, of nominal width of 244
ns, during the Sa bit cell times that are selected for the data link. Again, this selection is made by programming
address 10H of master control page 01H. No DL data will be lost or repeated when a receive frame slip occurs.
See Figures 13-16 for timing requirements.
Timeslot 16
Channel 16 may be used to create a transparent 64 kb/s clear channel. In this event CSTi (pin 6 in PLCC, pin 71 in
MQFP) becomes the data input pin for channel 16 transmit data, and CSTo (pin 5 in PLCC, pin 70 in MQFP)
becomes a 64 kb/s serial output link. The CSTo output link is synchronous to the extracted clock timebase. The pin
Rx64KCK (pin 47 in PLCC, pin 35 in MQFP) provides a 64 kHz clock for use with 64 kb/s data emanating from
CSTo. The 64 kb/s input data from CSTi is clocked in with an internal 64 kHz clock synchronous to the I/O pin C4b
(pin 45 in PLCC, pin 33 in MQFP) timebase. The internal clock toggles coincident with every second ST-BUS
channel boundary, with the first rising edge of a frame occurring at the beginning of ST-BUS channel 2.
Dual HDLC
The MT9075B has two identical HDLC controllers (HDLC0, HDLC1) for the S a bits and channel 16 respectively.
The following features are common to both HDLC controllers:
•
Independent transmit and receive FIFO's;
•
Receive FIFO maskable interrupts for nearly full (programmable interrupt levels) and overflow conditions;
•
Transmit FIFO maskable interrupts for nearly empty (programmable interrupt levels) and underflow
conditions;
•
Maskable interrupts for transmit end-of-packet and receive end-of-packet;
•
Maskable interrupts for receive bad-frame (includes frame abort);
•
Transmit end-of-packet and frame-abort functions.
HDLC0 Functions
When connected to the Data Link (DL) HDLC0 will operate at a selected bit rate of 4, 8, 12, 16 or 20 kbits/sec.
HDLC0 can be selected by setting the control bit HDLC0 (bit 7) to one in page 01H, address 14H. When this bit is
zero all interrupts from HDLC0 are masked. For more information refer to following sections.
HDLC1 Functions
This controller may be connected to time slot 16 under Common Channel Signalling (CCS) mode. It should be
noted that the AIS16S function (page 03H, address 19H) will always be active and the TAIS16 function (page 01H,
address 16H) will override all other transmit signalling.
HDLC1 can be selected by setting the control bit HDLC1 (bit 6) to one in page 01H, address 14H. When this bit is
zero all interrupts from HDLC1 are masked.
HDLC Overview
The HDLC handles the bit oriented packetized data transmission as per X.25 level two protocol defined by CCITT. It
provides flag and abort sequence generation and detection, zero insertion and deletion, and Frame Check
Sequence (FCS) generation and detection. A single byte, dual byte and all call address in the received frame can
be recognized. Access to the receive FCS and inhibiting of transmit FCS for terminal adaptation are also provided.
Each HDLC controller has a 128 byte deep FIFO associated with it. The status and interrupt flags are
programmable for FIFO depths that can vary from 16 to 128 bytes in steps of 16 bytes. These and other features
are enabled through the HDLC control registers on page 0BH and 0CH.
21
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
HDLC Frame Structure
A valid HDLC frame (also referred as “packet”) begins with an opening flag, contains at least 16 bits of data
field, and ends with a 16 bit FCS followed by a closing flag (Table 9).
All HDLC frames start and end with a unique flag sequence “011111102” (7EH). The transmitter generates these
flags and appends them to the packet to be transmitted. The receiver searches the incoming data stream for the
flags on a bit-by-bit basis to establish frame synchronization.
Opening
Flag (7EH)
Data
Field
FCS
Closing
Flag (7EH)
One Byte
01111110
n Bytes
n 
Two
Bytes
One Byte
01111110
Table 9 - HDLC Frame Format
The data field usually consists of an address field, control field and information field. The address field consists of
one or two bytes directly following the opening flag. The control field consists of one byte directly following the
address field. The information field immediately follows the control field and consists of n bytes of data. The HDLC
does not distinguish between the control and information fields and a packet does not need to contain an
information field to be valid.
The FCS field, which precedes the closing flag, consists of two bytes. A cyclic redundancy check utilizing the
CCITT standard polynomial “X16+X12+X5+1” produces the 16-bit FCS. In the transmitter the FCS is calculated on
all bits of the address and data field. The complement of the FCS is transmitted, most significant bit first, in the FCS
field. The receiver calculates the FCS on the incoming packet address, data and FCS field and compares the result
to “F0B8”. If no transmission errors are detected and the packet between the flags is at least 32 bits in length then
the address and data are entered into the receive FIFO minus the FCS which is discarded.
Data Transparency (Zero Insertion/Deletion)
Transparency ensures that the contents of a data packet do not imitate a flag, go-ahead, frame abort or idle
channel. The contents of a transmitted frame, between the flags, is examined on a bit-by-bit basis and a 0 is
inserted after all sequences of 5 contiguous 1s (including the last five bits of the FCS). Upon receiving five
contiguous 1s within a frame the receiver deletes the following 0.
Invalid Frames
A frame is invalid if one of the following four conditions exists:
•
If the FCS pattern generated from the received data does not match the “F0B8” pattern then the last data
byte of the packet is written to the received FIFO with a ‘bad packet’ indication.
•
A short frame exists if there are less than 25 bits between the flags. Short frames are ignored by the receiver
and nothing is written to the receive FIFO.
•
Packets which are at least 25 bits in length but less than 32 bits between the flags are also invalid. In this
case the data is written to the FIFO but the last byte is tagged with a “bad packet” indication.
•
If a frame abort sequence is detected the packet is invalid. Some or all of the current packet will reside in the
receive FIFO, assuming the packet length before the abort sequence was at least 26 bits long.
Frame Abort
The transmitter will abort a current packet by substituting a zero followed by seven contiguous 1s in place of the
normal packet. The receiver will abort upon reception of seven contiguous 1s occurring between the flags of a
packet which contains at least 26 bits.
22
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Note that should the last received byte before the frame abort end with contiguous 1s, these are included in the
seven 1s required for a receiver abort. This means that the location of the abort sequence in the receiver may occur
before the location of the abort sequence in the originally transmitted packet. If this happens then the last data
written to the receive FIFO will not correspond exactly with the last byte sent before the frame abort.
Interframe Time Fill and Link Channel States
When the HDLC transmitter is not sending packets it will wait in one of two states
•
Interframe Time Fill state: This is a continuous series of flags occurring between frames indicating that the
channel is active but that no data is being sent.
•
Idle state: An idle Channel occurs when at least 15 contiguous 1s are transmitted or received.
In both states the transmitter will exit the wait state when data is loaded into the transmitter FIFO.
Go-Ahead
A go-ahead is defined by a 9 bit sequence "011111110" (contiguous 7Fs) and hence is the occurrence of a frame
abort sequence followed by a zero. This feature is used to distinguish a proper in-packet frame abort sequence
from one occurring outside of a packet for some special applications
HDLC Functional Description
The HDLC controller can be reset by either the reset pin (RESET, pin 11 in PLCC or pin 84 in MQFP) or by the
control bit HRST at address 1BH in page 0BH (for HDLC0) or page 0CH (for HDLC1). When reset, the HDLC
Control Registers are cleared, resulting in the transmitter and receiver being disabled. The receiver and transmitter
can be enabled independent of each other through Control Register 1 at address 13H. The transceiver input and
output are enabled when the enable control bits in Control Register 1 are set. Transmit to receive loopback as well
as a receive to transmit loopback are also supported. Transmit and receive bit rates and enables can operate
independently.
Received packets from the serial interface are sectioned into bytes by an HDLC receiver that detects flags, checks
for go-ahead signals, removes inserted zeros, performs a cyclical redundancy check (CRC) on incoming data, and
monitors the address if required. Packet reception begins upon detection of an opening flag. The resulting bytes are
concatenated with two status bits (RQ9 and RQ8 at address 14H) and placed in a receiver first-in-first-out buffer
(RX FIFO). Register 14H also contains control bits that generate status and interrupts for microprocessor read
control.
In conjunction with the control circuitry, the microprocessor writes data bytes into a transmit buffer (TX FIFO)
register that generates status and interrupts. Packet transmission begins when the microprocessor writes a byte to
the TX FIFO. Two status bits are added to the TX FIFO for transmitter control of frame aborts (FA) and end of
packet (EOP) flags. Packets have flags appended, zeros inserted, and an FCS, added automatically during serial
transmission. When the TX FIFO is empty and finished sending a packet, Interframe Time Fill bytes (continuous
flags (7E hex)), or Mark Idle (continuous ones) are transmitted to indicate that the channel is idle.
HDLC Transmitter
Following initialization and enabling, the transmitter is in the Idle Channel state (Mark Idle), continuously sending
ones. Interframe Time Fill state (Flag Idle) is selected by setting the Mark Idle bit in Control Register 1 to one1. The
transmitter remains in either of these two states until data is written to the TX FIFO. Control Register 1 bits EOP
(End Of Packet) and FA (Frame Abort) are set as status bits before the microprocessor loads 8 bits of data into the
1. If the MT9075B HDLC transmitter is set up in the Interframe Time Fill state (bit 2 Mark-Idle =1, page B or C, address 13H), then it will
occasionally (less than 1% of the time) fail to transmit the opening flag when it is changed from the disabled state to the enabled state
(bit 5 TxEN changed from 0 to 1). A missing opening flag will cause the packet to be lost at the receiving end.
This problem only affects the first packet transmitted after the HDLC transmitter is enabled. Subsequent packets are unaffected.
23
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
10 bit wide FIFO (8 bits data and 2 bits status). To change the tag bits being loaded in the FIFO, Control Register 1
must be written to before writing to the FIFO. However, EOP and FA are reset after writing to the TX FIFO. The
Transmit Byte Count Register may also be used to tag an EOP. The register is loaded with the number of bytes in
the packet and decrements after every write to the Tx FIFO. When a count of one is reached, the next byte written
to the FIFO is tagged as an end of packet. The register may be made to cycle through the same count if the packets
are of the same length by setting Control Register 2, bit Cycle (at address 15H of page 0BH for HDLC0 or 0CH for
HDLC1).
If the transmitter is in the Idle Channel state when data is written to the TX FIFO, then an opening flag is sent and
data from TX FIFO follows. Otherwise, data bytes are transmitted as soon as the current flag byte has been sent.
TX FIFO data bytes are continuously transmitted until either the FIFO is empty or an EOP or FA status bit is read by
the transmitter. After the last bit of the EOP byte has been transmitted, a 16-bit FCS is sent followed by a closing
flag. When multiple packets of data are loaded into TX FIFO, only one flag is sent between packets.
Frame Aborts (FA, the transmission of 7F hex), are transmitted by tagging a byte previously written to the TX FIFO.
When a byte has an FA tag, then an FA is sent instead of that tagged byte. That is, all bytes previous to but not
including that byte are sent. After an FA, the transmitter returns to the Mark Idle or Interframe Time Fill state,
depending on the state of the Mark idle control bit.
TX FIFO underrun will occur if the FIFO empties and the last byte did not have either an EOP or FA tag. A frame
abort sequence will be sent when an underrun occurs.
Below is an example of the transmission of a three byte packet (’AA’’03’’77’ hex) (Interframe time fill). TxEN can be
enabled before or after this sequence.
(a) Write’04’ to Control Register 1 - Mark Idle bit set
(b) Write’AA’ to Tx FIFO -Data byte
(c) Write’03’ to Tx FIFO - Data byte
(d) Write’34’ to Control Register 1 - TxEN; EOP; Mark Idle bits set
(e) Write’77’ to Tx FIFO - Final data byte
The transmitter may be enabled independently of the receiver. This is done by setting the TxEN bit of the Control
Register. Enabling happens immediately upon writing to the register. Disabling using TxEN will occur after the
completion of the transmission of the present packet; the contents of the FIFO are not cleared. Disabling will consist
of stopping the transmitter clock. The Status and Interrupt Registers may still be read, and the FIFO and Control
Registers may be written to while the transmitter is disabled. The transmitted FCS may be inhibited using the Tcrci
bit of Control Register 2. In this mode the opening flag followed by the data and closing flag is sent and zero
insertion is still included, but no FCS. That is, the FCS is injected by the microprocessor as part of the data field.
This is used in V.120 terminal adaptation for synchronous protocol sensitive UI frames.
HDLC Receiver
After initialization and enabling, the receiver clocks in serial data, continuously checking for Go-Aheads (0 1111
1110), flags (0111 1110), and Idle Channel states (at least fifteen ones). When a flag is detected, the receiver
synchronizes itself to the serial stream of data bits, automatically calculating the FCS. If the data length between
flags after zero removal is less than 25 bits, then the packet is ignored so no bytes are loaded into Rx FIFO. When
the data length after zero removal is between 25 and 31 bits, a first byte and bad FCS code are loaded into the Rx
FIFO. For an error-free packet, the result in the CRC register should match the HEX pattern of “F0B8” when a
closing flag is detected.
If address recognition is required, the Receiver Address Recognition Registers (address 10H and 11H) are loaded
with the desired address and the Adrec bit in the Control Register 1 (address 13H) is set to one. Bit 0 of the
Address Registers is used as an enable bit for that byte, thus allowing either or both of the first two bytes to be
compared to the expected values. In addition, seven bits of address comparison can be realized on the first byte if
this is a single byte address by setting the Seven bit of Control Register 2 (address 15H).
24
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Two Status Register bits (RQ8 and RQ9) are appended to each data byte as it is written to the Rx FIFO. They
indicate that a good packet has been received (good FCS and no frame abort), or a bad packet with either incorrect
FCS or frame abort. The Status and Interrupt Registers should be read before reading the Rx FIFO since status and
interrupt information correspond to the byte at the output of the FIFO (i.e., the byte about to be read). The Status
Register bits are encoded as follows:
RQ9
1
0
1
0
RQ8
1
1
0
0
Byte status
last byte (bad packet)
bad packet
last byte (good packet)
packet byte
The end-of-packet-detect (EOPD) interrupt indicates that the last byte written to the RX FIFO was an EOP byte.
The end-of-packet-read (EOPR) interrupt indicates that the byte about to be read from the RX FIFO is an EOP byte.
The Status Register should be read to see if the packet is good or bad before the byte is read.
A minimum size packet has an 8-bit address, an 8-bit control byte, and a 16-bit FCS pattern between the opening
and closing flags. Thus, the absence of a data transmission error and a frame length of at least 32 bits results in the
receiver writing a valid packet code with the EOP byte into RX FIFO. The last 16 bits before the closing flag are
regarded as the FCS pattern and will not be transferred to the receiver FIFO. Only data bytes (Address, Control,
Information) are loaded into the Rx FIFO.
In the case of an RX FIFO overflow, no clocking occurs until a new opening flag is received. In other words, the
remainder of the packet is not clocked into the FIFO. Also, the top byte of the FIFO will not be written over. If the
FIFO is read before the reception of the next packet then reception of that packet will occur. If two beginning of
packet conditions (RQ9=0; RQ8=1) are seen in the FIFO, without an intermediate EOP status, then overflow
occurred for the first packet.
The receiver may be enabled independently of the transmitter. This is done by setting the RxEN bit of Control
Register 1. Enabling happens immediately upon writing to the register. Disabling using RxEN will occur after the
present packet has been completely loaded into the FIFO. Disabling can occur during a packet if no bytes have
been written to the FIFO yet. Disabling will consist of disabling the internal receive clock. The FIFO, Status, and
Interrupt Registers may still be read while the receiver is disabled. Note that the receiver requires a flag before
processing a frame, thus if the receiver is enabled in the middle of an incoming packet it will ignore that packet and
wait for the next complete one.
The receive CRC (FCS) can be monitored in the Rx CRC Registers (address 18H and 19H). These registers
contain the actual CRC sent by the other transmitter in its original form, that is, MSB first and bits inverted. These
registers are updated by each end of packet (closing flag) received and therefore should be read when an end of
packet is received so that the next packet does not overwrite the registers.
Slip Buffer
In addition to the elastic buffer in the jitter attenuator(JA), another elastic buffer (two frames deep) is present,
attached between the receive side and the ST-BUS (or GCI Bus) side of the MT9075B. This elastic buffer is
configured as a slip buffer which absorbs wander and low frequency jitter in multi-trunk applications. The received
PCM 30 data is clocked into the slip buffer with the E2o clock and is clocked out of the slip buffer with the C4b clock.
The E2o extracted clock is generated from, and is therefore phase-locked with, the receive PCM 30 data. In normal
operation, the E2o clock will be phase-locked to the C4b clock by an external phase locked loop (PLL). Therefore,
in a single trunk system the receive data is in phase with the E2o clock, the C4b clock is phase-locked to the E2o
clock, and the read and write positions of the slip buffer will remain fixed with respect to each other.
In a multi-trunk slave or loop-timed system (i.e., PABX application) a single trunk will be chosen as a network
synchronizer, which will function as described in the previous paragraph. The remaining trunks will use the system
timing derived from the synchronizer to clock data out of their slip buffers. Even though the PCM 30 signals from the
network are synchronous to each other, due to multiplexing, transmission impairments and route diversity, these
25
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
signals may jitter or wander with respect to the synchronizing trunk signal. Therefore, the E2o clocks of nonsynchronizer trunks may wander with respect to the E2o clock of the synchronizer and the system bus.
Network standards state that, within limits, trunk interfaces must be able to receive error-free data in the presence
of jitter and wander (refer to network requirements for jitter and wander tolerance). The MT9075B will allow a
maximum of 26 channels (208 UI, unit intervals) of wander and low frequency jitter before a frame slip will occur.
The minimum delay through the receive slip buffer is approximately two channels and the maximum delay is
approximately 60 channels (see Figure 9).
When the C4b and the E2o clocks are not phase-locked, the rate at which data is being written into the slip buffer
from the PCM 30 side may differ from the rate at which it is being read out onto the ST-BUS. If this situation
persists, the delay limits stated in the previous paragraph will be violated and the slip buffer will perform a controlled
frame slip. That is, the buffer pointers will be automatically adjusted so that a full PCM 30 frame is either repeated
or lost. All frame slips occur on PCM 30 frame boundaries.
Two status bits, RSLIP and RSLPD (page 03H, address 15H), give indication of a slip occurrence and direction.
RSLIP changes state in the event of a slip. If RSLPD=0, the slip buffer has overflowed and a frame was lost; if
RSLPD=1, a underflow condition occurred and a frame was repeated. A maskable interrupt SLPI (page 01H,
address 1BH) is also provided.
Figure 9 illustrates the relationship between the read and write pointers of the receive slip buffer. Measuring
clockwise from the write pointer, if the read pointer comes within two channels of the write pointer a frame slip will
occur, which will put the read pointer 34 channels from the write pointer. Conversely, if the read pointer moves more
than 60 channels from the write pointer, a slip will occur, which will put the read pointer 28 channels from the write
pointer. This provides a worst case hysteresis of 13 channels peak (26 channels peak-to-peak) or a wander
tolerance of 208 UI.
Write Pointer
60 CH
Read Pointer
512 Bit
Elastic
Store
47 CH
34 CH
Read Pointer
13 CH
2 CH
26 Channels
Read Pointer
15 CH
28 CH
Wander Tolerance
-13 CH
Read Pointer
Figure 9 - Read and Write Pointers in the Slip Buffers
Framing Algorithm
The MT9075B contains three distinct framing algorithms: basic frame alignment, signalling multiframe alignment
and CRC-4 multiframe alignment. Figure 10 is a state diagram that illustrates these algorithms and how they
interact.
After power-up, the basic frame alignment framer will search for a frame alignment signal (FAS) in the PCM 30
receive bit stream. Once the FAS is detected, the corresponding bit 2 of the non-frame alignment signal (NFAS) is
checked. If bit 2 of the NFAS is zero a new search for basic frame alignment is initiated. If bit 2 of the NFAS is one
26
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
and the next FAS is correct, the algorithm declares that basic frame synchronization has been found (i.e., page
03H, address 10H, bit 7, SYNC is zero).
Once basic frame alignment is acquired the signalling and CRC-4 multiframe searches will be initiated. The
signalling multiframe algorithm will align to the first multiframe alignment signal pattern (MFAS = 0000) it receives in
the most significant nibble of channel 16 (page 3, address 10H, bit 6, MFSYNC = 0). Signalling multiframing will be
lost when two consecutive multiframes are received in error.
The CRC-4 multiframe alignment signal is a 001011 bit sequence that appears in PCM 30 bit position one of the
NFAS in frames 1, 3, 5, 7, 9 and 11 (see Table 7). In order to achieve CRC-4 synchronization two CRC-4 multiframe
alignment signals must be received without error (page 03H, address 10H, bit 5, CRCSYN = 0) within 8 msec.
The MT9075B framing algorithm supports automatic interworking of interfaces with and without CRC-4 processing
capabilities. That is, if an interface with CRC-4 capability, achieves valid basic frame alignment, but does not
achieve CRC-4 multiframe alignment by the end of a predefined period, the distant end is considered to be a nonCRC-4 interface. When the distant end is a non-CRC-4 interface, the near end automatically suspends receive
CRC-4 functions, continues to transmit CRC-4 data to the distant end with its E-bits set to zero, and provides a
status indication. Naturally, if the distant end initially achieves CRC-4 synchronization, CRC-4 processing will be
carried out by both ends. This feature is selected when control bit AUTC (page 01H, address 11H) is set to zero.
Notes for Synchronization State Diagram (Figure 10)
1. The basic frame alignment, signalling multiframe alignment, and CRC-4 multiframe alignment functions operate
in parallel and are independent.
2. The receive channel associated signalling bits and signalling multiframe alignment bit will be frozen when multiframe alignment is lost.
3. Manual re-framing of the receive basic frame alignment and signalling multiframe alignment functions can be
performed at any time.
4. The transmit RAI bit will be one until basic frame alignment is established, then it will be zero.
5. E-bits can be optionally set to zero until the equipment interworking relationship is established. When this has
been determined one of the following will take place:
a. CRC-to-non-CRC operation - E-bits = 0,
b. CRC-to-CRC operation - E-bits as per G.704 and I.431.
6. All manual re-frames and new basic frame alignment searches start after the current frame alignment signal
position.
7. After basic frame alignment has been achieved, loss of frame alignment will occur any time three consecutive
incorrect basic frame alignment signals are received. Loss of basic frame alignment will reset the complete
framing algorithm.
8. When CRC-4 multiframing has been achieved, the primary basic frame alignment and resulting multiframe
alignment will be adjusted to the basic frame alignment determined during CRC-4 synchronization. Therefore,
the primary basic frame alignment will not be updated during the CRC-4 multiframing search, but will be updated
when the CRC-4 multiframing search is complete.
27
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Out of synchronization
YES
NO
Search for primary basic frame
alignment signal RAI=1, Es=0.
3 consecutive
incorrect frame
alignment
signals
YES
>914 CRC errors
in one second
NO
Verify Bit 2 of non-frame
alignment signal.
YES
Verify second occurrence of
frame alignment signal.
No CRC
multiframe alignment.
8 msec. timer expired*
NO
YES
CRC-4 multi-frame alignment
Primary basic frame synchronization
acquired. Enable traffic RAI=0, E’s=0. Start
loss of primary basic frame alignment
checking. Notes 7 & 8.
Signalling multi-frame alignment
Search for multiframe
alignment signal.
Note 7.
Start 400 msec timer.
Note 7.
YES
NO
Multiframe synchronization
acquired as per G.732.
Note 7.
RAI = 0
Start 8 msec timer.
Note 7.
Basic frame
alignment acquired
NO
YES
No CRC
multiframe
alignment.
Find two CRC frame
alignment signals.
Note 7.
Check for two consecutive errored
multiframe alignment signals.
Notes 7 & 8.
8 msec
Parallel search for new basic frame
alignment signal.
RAI = 1
Notes 6 & 7.
CRC multiframe
alignment
CRC-to-CRC interworking. Re-align to new basic
frame alignment. Start CRC-4 processing. E-bits set as
per G.704 and I.431. Indicate CRC synchronization
achieved.
Notes 7& 8.
only if CRC-4 synchronization is selected and automatic CRC-4
interworking is de-selected
400 msec timer expired
CRC-to-non-CRC interworking. Maintain primary
basic frame alignment. Continue to send CRC-4
data, but stop CRC processing. E-bits set to ‘0’.
Indicate CRC-to-non-CRC operation. Note 7.
* only if CRC-4 synchronization is selected and automatic CRC-4
interworking is de-selected.
** only if automatic CRC-4 interworking is selected.
Figure 10 - Synchronization State Diagram
28
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Channel Signalling
When control bit TxCCS (page 01H, address 1AH) is set to one, the MT9075B is in Common Channel Signalling
(CCS) mode. When TxCCS is low it is in Channel Associated Signalling mode (CAS). The CAS mode ABCD
signalling nibbles can be passed either via the micro-ports (when page 01H, address 1AH, bit 3, RPSIG = 1) or
through related channels of the CSTo and CSTi serial links (when RPSIG = 0). Memory page 05H contains the
receive ABCD nibbles and page 06H the transmit ABCD nibbles for micro-port CAS access.
In CAS operation an ABCD signalling bit debounce of 14 msec. can be selected by writing a one to DBNCE (page
02H, address 10H, bit 0)). This is consistent with the signalling recognition time of ITU-T Q.422. It should be noted
that there may be as much as 2 msec. added to this duration because signalling equipment state changes are not
synchronous with the PCM 30 multiframe.
If multiframe synchronization is lost (page 03H, address 10H, bit 6, MFSYNC = 1) all receive CAS signalling nibbles
are frozen. Receive CAS nibbles will become unfrozen when multiframe synchronization is acquired.
When the CAS signalling interrupt is unmasked (page 01H, address 1CH, bit 0, SIGI=1), pin IRQ (pin 12 in PLCC,
85 in MQFP) will become active when a signalling nibble state change is detected in any of the 30 receive
channels. The SIGI interrupt vector (page 04H, address 12H) is 01H.
In CCS mode the data transmit on channel 16 is either sourced from channel 16 data on DSTi or from the pin
CSTi. If 64KCCS (page 01H, address 1AH, bit 0) is zero the data is sourced from DSTi. If 64KCCS is high data
destined for channel 16 is clocked in from CSTi (pin 6 in PLCC, pin 71 in MQFP) with an internal 64 KHz clock
divided down from C4b. Data received from channel 16 is clocked out on CSTo (pin 5 in PLCC, pin 70 in
MQFP). By dividing down the extracted 2.048 MHz clock, a 64 kHz receive clock synchronous with the data is
created. This signal is output on Rx64KCK (pin 47 in PLCC, pin 35 in MQFP).
Loopbacks
In order to meet PRI Layer 1 requirements and to assist in circuit fault sectionalization, the MT9075B has six
loopback functions. The control bits for digital, remote, ST-BUS, payload and metallic loopbacks are located on
page 01H, address 15H. The remote and local time slot loopbacks are controlled through control bits 5 and 4 of the
Per Time Slot Control Words on pages 07H and 08H.
a) Digital Loopback (DG Loop) - DSTi to DSTo at the framer LIU interface. Bit DLBK = 0 normal; DLBK = 1
activate.
MT9075B
DSTi
System
DSTo
Tx
PCM30
b) Remote Loopback (RM Loop) - RTIP and RRING to TTIP and TRING respectively at the PCM 30 side. Bit
RLBK = 0 normal; RLBK = 1 activate.
MT9075B
Tx
PCM30
Rx
System
DSTo
c) ST-BUS Loopback (ST Loop) - DSTi to DSTo at the system side. Bit SLBK = 0 normal; SLBK = 1 activate.
29
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
MT9075B
DSTi
System
DSTo
Tx
PCM30
d) Payload Loopback (PL Loop) - RTIP and RRING to TTIP and TRING respectively at the system side with
FAS and NFAS operating normally. Bit PLBK = 0 normal; PLBK = 1 activate. The payload loopback is effectively
a physical connection of DSTo to DSTi within the MT9075B. Channel zero and the DL originate at the point of
loopback.
MT9075B
DSTi
System
DSTo
Tx
Rx PCM30
e) Metallic Loopback (MT Loop) - The external signals RTIP and RRING are isolated from the receiver and the
analog outputs TTIP and TRING are internally connected to the receiver analog input. Bit MLBK = 0 normal;
MLBK = 1 activate.
MT9075B
DSTi
System
DSTo
Tx
Rx PCM30
f) Local and Remote Time Slot Loopback. Remote time slot loopback control bit RTSL = 0 normal; RTSL = 1
activate, will loop around receive PCM 30 time slots to the transmit PCM 30 time slots. Local time slot loopback
bit LTSL = 0 normal; LTSL = 1 activate, will loop around DSTi time slots towards the DSTo time slots.
MT9075B
System
DSTi
Tx
DSTo
Rx
PCM30
Error Counters
The MT9075B has nine error counters, which can be used for maintenance testing, an ongoing measure of the
quality of a PCM 30 link and to assist the designer in meeting specifications such as ITU-T I.431 and G.821. All
counters can be preset or cleared by writing to the appropriate locations. A separate status page - “1 Second
Status” on page 09H - latches the states of the following counters: E-bit Error Counter, Errored Frame Alignment
Signal Counter, Bipolar Violation Counter and CRC Error Counter on a one second interval, coincident with the one
second status bit.
Associated with each counter is a maskable event occurrence interrupt and a maskable counter overflow interrupt.
Overflow interrupts are useful when cumulative error counts are being recorded. For example, every time the frame
error counter overflow (FERO) interrupt occurs, 256 frame errors have been received since the last FERO interrupt.
All counters are cleared and held low by programming the counter clear bit (master control page 01H, address 1AH,
bit 2) high. Counter overflows set bits in the counter overflow latch (page 04H, address 16H); this latch is cleared
when read.
30
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
The overflow reporting latch (page 04H, address 16H) contains a register whose bits are set when individual
counters overflow. These bits stay high until the register is read.
PRBS Error Counter (PS7-0)
There are two 8 bit counters associated with PRBS comparison; one for errors and one for time. Any errors that are
detected in the receive PRBS will increment the PRBS Error Rate Counter of page 04H, address 10H. Writes to this
counter will clear an 8 bit counter, PSM7-0 (page 01H, address 11H) which counts receive CRC-4 multiframes. A
maskable PRBS counter overflow (PRBSO) interrupt (page 1, address 19H) is associated with this counter.
CRC Multiframe Counter for PRBS (PSM7-0)
This eight bit counter counts receive CRC-4 multiframes. It can be directly loaded via the microport. The counter will
also be automatically cleared in the event that the PRBS error counter is written to by the microport. This counter is
located on page 04H, address 11H.
E-bit Counter (EC9-0)
E-bit errors are counted by the MT9075B in order to support compliance with ITU-T requirements. This ten bit
counter is located on page 04H, addresses 13H and 14H respectively. It is incremented by single error events, with
a maximum rate of twice per CRC-4 multiframe.
There are two maskable interrupts associated with the E-bit error measurement. EBI (page 1, address 1CH) is
initiated when the least significant bit of the counter toggles, and EBO (page 01H, address 1DH) is initiated when
the counter overflows.
Jitter FIFO Counter (JFC7-0)
This is an eight bit counter that is incremented when the FIFO read pointer comes within 4 words of an underflow or
overflow condition. During this time the read clock will abruptly speed-up or slow-down to avoid an overflow or
underflow condition. This counter is located on page 04H, address 15H.
Loss of Synchronization Counter (LBF7-0)
This eight bit counter increments with each loss of basic frame alignment. This programmable counter is located on
page 04H, address 17H.
Bit Error Rate Counter (BR7-BR0)
An 8 bit Error Rate (BERT) counter BR7 - BR0 is located on page 04H address 18H, and is incremented once for
every bit detected in error on either the seven frame alignment signal bits.
There are two maskable interrupts associated with the bit error rate measurement. BERI (page 01H, address 1CH)
is initiated when the least significant bit of the BERT counter (BR0) toggles, and BERO (page 01H, address 1DH) is
initiated when the BERT counter value changes from FFH to 00H.
Errored FAS Counter (EFAS7-EFAS0)
An eight bit Frame Alignment Signal Error counter EFAS7 - EFAS0 is located on page 04H address 1AH, and is
incremented once for every receive frame alignment signal that contains one or more errors.
There are two maskable interrupts associated with the frame alignment signal error measurement. FERI (page
01H, address 1BH) is initiated when the least significant bit of the errored frame alignment signal counter toggles,
and FERO (page 01H, address 1DH) is initiated when the counter changes from FFH to 00H.
31
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bipolar Violation Error Counter (BPV15-BPV0)
The bipolar violation error counter will count bipolar violations or encoding errors that are not part of HDB3
encoding. This counter BPV15-BPV0 is 16 bits long (page 04H, addresses 1DH and 1CH) and is incremented once
for every BPV error received. It should be noted that when presetting or clearing the BPV error counter, the least
significant BPV counter address should be written to before the most significant location.
There are two maskable interrupts associated with the bipolar violation error measurement. BPVI (page 01H,
address 1CH) is initiated when the least significant bit of the BPV error counter toggles. BPVO (page 01H, address
1BH) is initiated when the counter changes from FFFFH to 0000H.
CRC Error Counter (CC9-0)
CRC-4 errors are counted by the MT9075B in order to support compliance with ITU-T requirements. This ten bit
counter is located on page 04H, addresses 1EH and 1FH respectively. It is incremented by single error events,
which is a maximum rate of twice per CRC-4 multiframe.
There is a maskable interrupts associated with the CRC error measurement. CRCI (page 01H, address 1CH) is
initiated when the least significant bit of the counter toggles, and CRCO (page 01H, address 1DH) is initiated when
the counter overflows.
Error Insertion
Six types of error conditions can be inserted into the transmit PCM 30 data stream through control bits, which are
located on page 02H, address 10H. These error events include the bipolar violation errors (BPVE), CRC-4 errors
(CRCE), FAS errors (FASE), NFAS errors (NFSE), payload (PERR) and a loss of signal error (LOSE). The LOSE
function overrides the HDB3 encoding function.
Per Time Slot Control
There are two per time slot control pages (page 07H and 08H) occupying a total of 32 unique addresses. Each
address controls a matching timeslot on the 32 transmit channels (onto the line) and the equivalent channel data on
the receive (DSTo) data. For example, address 0 of the first per time slot control page contains program control for
transmit timeslot 0 and DSTo channel 0.
Per Time Slot Looping
Any channel or combination of channels may be looped from transmit (sourced from DSTi) to receive (output on
DSTo) STBUS channels. When bit 4 (LTSL) in the Per Time Slot Control Word is set the data from the equivalent
transmit timeslot is looped back onto the equivalent receive channel.
Any channel or combination of channels may be looped from receive (sourced from the line data) to transmit
(output onto the line) channels. When bit 5 (RTSL) in the Per Time Slot Control Word is set the data from the
equivalent receive timeslot is looped back onto the equivalent transmit channel.
PRBS Testing
If the control bit ADSEQ is zero (from master control page 02H address 13H - Access Control Word), any
channel or combination of transmit channels may be programmed to contain a generated pseudo random bit
sequence (215-1). The channels are selected by setting bit 3 (TTST) in the Per Time Slot Control Word.
1. If the control bit ADSEQ is zero any combination of receive channels may be connected to the PRBS decoder
(215-1). Each error in the incoming sequence causes the PRBS error counter to increment. The receive channels are selected by setting bit 2 (RRST) in the Per Time Slot Control Word.
If the PRBS testing is performed in a metallic or external looparound the Per Time Slot Control Words with TTST
(transmit test, bit 3) set should have RRST (receive test, bit 2) set at the same time.
32
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
A-law Milliwatt
If the control bit ADSEQ is one (from master control page 02H - access control word), the A-law digital milliwatt
sequence (Table 10), defined by G.711, is available to be transmit on any combination of selected channels. The
channels are selected by setting bit 3 (TTST), in the Per Time Slot Control Word.
The same sequence is available to replace received data on any combination of DSTo channels. This is
accomplished by setting bit 2 (RRST) in the Per Time Slot Control Word for the corresponding channel.
Bit
1
Bit
2
Bit
3
Bit
4
Bit
5
Bit
6
Bit
7
Bit
8
0
0
1
1
0
1
0
0
0
0
1
0
0
0
0
1
0
0
1
0
0
0
0
1
0
0
1
1
0
1
0
0
1
0
1
1
0
1
0
0
1
0
1
0
0
0
0
1
1
0
1
0
0
0
0
1
1
0
1
1
0
1
0
0
Table 10 - A-Law Digital Milliwatt Pattern
Message Mode
The transmit data on any of the transmit channels may be sourced either from the equivalent DSTi channel or from
a dual port RAM programmed by the microport. The address of each dual port RAM memory location is uniquely
associated with a transmit channel number. When bit 7 (TXMSG) in the Per Time Slot Control Word for that channel
is set the transmit data for the channel is sourced from within the transmit message page dual port RAM (on page
0FH and 10H).
Receive data may also be read by the microprocessor port. The Rx message mode dual port RAMs (on page
11H and 12H) have a unique address associated with each incoming line channel. When the processor reads
any of the 32 memory locations, it reads the last byte received from the corresponding channel.
Alarms
The following alarms are detected by the receiver. Each may generate a maskable interrupt:
•
Remote Alarm Indication (RAI) - bit 3 (A) of the receive NFAS;
•
Alarm Indication Signal (AIS) - unframed all ones signal for at least a double frame (512 bits) or two double
frames (1024 bits);
•
Channel 16 Alarm Indication Signal - all ones signal in channel 16;
•
Auxiliary pattern - 101010... pattern for at least 512 bits;
•
Loss of Signal - a loss of signal condition occurs when the receive signal is detected with more than 127
consecutive zeros. A loss of signal condition will terminate when an average ones density of at least 12.5%
has been received over a period of 127 contiguous pulse positions starting with a pulse.
•
Remote Signalling Multiframe Alarm - bit 6 (Y-bit) of the multiframe alignment signal.
•
T1 - (T1 timer bit on page 03H address 12H) this status bit (and maskable interrupt) shall be high when a
signal that is not normal has been received for a minimum of 100 msec. This bit will be low when a normal
signal is being received.
33
Zarlink Semiconductor Inc.
MT9075B
•
Data Sheet
T2 - (T2 timer bit on page 03H address 12H) this status bit (and maskable interrupt) shall be high when a
normal signal has been received for a minimum of 10 msec. This bit will be low when an abnormal signal is
being received.
The alarm reporting latch (address 1BH page 04H) contains a register whose bits are set high for selected alarms.
These bits stay high until the register is read. This allows the controller to record intermittent or sporadic alarm
occurrences.
Automatic Alarms
The transmission of RAI and signalling multiframe alarms can be made to function automatically from control bits
ARAI and AUTY (page 01H, address 11H) When ARAI = 0 and basic frame synchronization is lost (page 03H,
address 10H, bit 7, SYNC = 1), the MT9075 will automatically transmit the RAI alarm signal to the far end of the
link. The transmission of this alarm signal will cease when basic frame alignment is acquired.
When AUTY = 0 and signalling multiframe alignment is not acquired (page 03H, address 10H, bit 6, MFSYNC = 1),
the MT9075 will automatically transmit the multiframe alarm (Y-bit) signal to the far end of the link. This
transmission will cease when signalling multiframe alignment is acquired.
Interrupts
The MT9075B has an extensive suite of maskable interrupts, which are divided into eight categories based on the
type of event that caused the interrupt. Each interrupt category has an associated interrupt vector described in
Table 11. When unmasked interrupts occur, IRQ will go low and one or more bits of the interrupt vector IV7-IV0
(page 04H, address 12H) will go high. After the interrupt vector is read it is automatically cleared and IRQ will return
to a high impedance state. The interrupt acknowledgment function can also be accomplished by toggling the INTA
bit (page 01H, address 1AH).
All the interrupts of the MT9075B are maskable. This is accomplished through the corresponding interrupt mask
words on page 01H (except for the HDLC interrupt mask registers which are located on page 0BH and 0CH).
National Use Bit Interrupt Mask Word (address 19H)
Bit 7
---
Bit 0
PRBSO
PRBS
SanibI
SabitI
C8Sa6I
Sa6I
Sa5I
Interrupt Mask Word Zero (address 1BH)
Bit 7
SYNI
Bit 0
RAII
AISI
AISI6I
LOSI
FERI
BPVO
SLPI
Interrupt Mask Word One (address 1CH)
Bit 7
EBI
Bit 0
CRCI
CEFI
BPVI
RCR1
RCR0
BERI
SIGI
Interrupt Mask Word Two (address 1DH)
Bit 7
EBO
Bit 0
CRCO
CALNI
FERO
JAI
BERO
AUXPI
CMFO
34
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Interrupt Mask Word Three (address 1EH)
Bit 7
MFSYI
Bit 0
CSYNI
---
YI
1SEC
T1I
T2I
HDLC Interrupt Masks (page 0BH&0CH, address 16H)
Bit 7
Ga
EOPD
TEOP
EopR
TxFl
FATxU
---
Bit 0
RxFf
RxOv
After a device reset (RESET pin or RST control bit), interrupts from the following interrupt mask words are masked:
•
National use bit interrupt mask word
•
Interrupt mask words one through three.
•
HDLC interrupt mask word.
and the interrupts of mask word zero are unmasked.
All interrupts may be suspended, without changing the interrupt mask words, by making the SPND control bit (page
01H, address 1AH) high. Also, when pin TAIS is held low, all interrupts are suspended automatically. This allows for
system initialization without spurious interrupts.
Interrupt
Category and
Vector
Synchronization
D7
D0
10000000
Alarm
D7
D0
01000000
Counter
Indication
D7
D0
00100000
Counter
Overflow
D7
D0
00010000
One Second
D7
D0
00001000
Interrupt Description
SYNI - Loss of Synchronization.
MFSYI - Loss of Multiframe Sync.
CSYNI - Loss of CRC-4 Sync.
YI - Remote Multiframe Sync. Fail.
RAII - Remote Alarm Indication.
AISI - Alarm Indication Signal.
AIS16I - AIS on Channel 16.
LOSI - Loss of Signal.
AUXPI - Auxiliary Pattern.
EBI - Receive E-bit Error.
CRCI - CRC-4 Error.
CEFI - Consecutive Errored FASs.
FERI - Frame Alignment Signal Error.
BPVI - Bipolar Violation Error.
RCR0 - RAI and CRC Error Active.
RCR1 - RAI and CRC Error End.
BERI - Bit Error.
EBO - Receive E-bit Error.
CRCO - CRC-4 Error.
FERO - Frame Alignment Signal.
BPVO - Bipolar Violation.
BERO - Bit Error.
CMFO - CRC-4 Multiframe.
1SECI - One Second Timer.
CALNI - CRC-4 Multiframe Alignment.
T1I - Timer T1 expires.
T2I - Timer T2 expires.
35
Zarlink Semiconductor Inc.
MT9075B
Interrupt
Category and
Vector
SLIP
D7
D0
00000100
National
Use/HDLC0
D7
D0
00000010
Signalling/HDLC1
D7
Interrupt Description
SLPI - Receive Slip.
JAI - Jitter Attenuator Error.
PRBSO-PRBS Error Counter Overflow
PRBSI - PRBS Single Error
SanibI - Changed Sa5,6,7 or 8 Nibble
SabitI - Changed Sa5,6,7 or 8 Bits
C8SA6I- Sequence of 8 Sa6 nibbles.
SA6I - Changed Sa6 nibbles.
SA5I - Changed Sa5 bits.
HDLC0 - Status
SIGI-Receive Signalling Bit Change.
HDLC1 - Status.
D0
00000001
Table 11 - MT9075B Interrupt Vectors
(IV7 - IV0)
36
Zarlink Semiconductor Inc.
Data Sheet
MT9075B
Data Sheet
Control and Status Registers
Master Control 1 (Page 01H)
Address
(A4A3A2A1A0)
Register
Names
10H (Table 13)
Multiframe, National Bit Buffer and Data ASEL, MFSEL, NBTB & Sa4 - Sa8
Link Selection Word
11H (Table 14)
Mode Selection Control Word
TIU0, CRCM, RST, ARAI, AUTY, TxTRSP,
CSYN & AUTC
12H (Table 15)
Non-Frame Alignment Control Word
TIU1, TALM & TNU4-8
13H (Table 16)
Transmit Multiframe Alignment Signal
TMA1-4, X1, Y, X2 & X3
14H (Table 17)
HDLC Selection Word
HDLC0, HDLC1, RxTRSP
15H (Table 18)
Coding and Loopback Control Word
MLBK, HDB3, MFRF, DLBK, RLBK, SLBK &
PLBK
16H (Table 19)
Transmit Alarm Control Word
TAIS, TAIS0, TAIS16, TE, REFRM, 64KSEL,
DSToDE & CSToDE
17H
Reserved
Set all bits to zero for normal operation.
18H
---
Unused.
19H (Table 20)
National Use Bit Interrupt Mask Word
PRBSO,PRBSI,SanibI,SabitI,C8Sa6I, Sa6I, Sa5I
1AH (Table 21)
Interrupt, Signalling and BERT Control ODE, SPND, INTA, TxCCS, RPSIG, CNTCLR
Word
& MSN, 64KCCS
1BH (Table 22)
Interrupt Mask Word Zero
SYNI, RAII, AISI, AIS16I, LOSI, FERI, BPVO &
SLPI
1CH (Table 23)
Interrupt Mask Word One
EBI, CRCI, CEFI, BPVI, RCR0I, RCR1I, BERI
& SIGI
1DH (Table 24)
Interrupt Mask Word Two
EBOI, CRCOI, CALNI, FEROI, JAI, BEROI,
AUXPI & CMFOI
1EH (Table 25)
Interrupt Mask Word Three
MFSYI, CSYNI, YI, 1SECI, T1I, T2I
1FH (Table 26)
Transmit Pulse Control Word
CTXP, LL0, LL1, LL2
Table 12 - Master Control 1 (Page 01H)
37
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
ASEL
(0)
AIS Select. This bit selects the criteria on which the detection of a valid Alarm
Indication Signal (AIS) is based. If zero, the criteria is less than three zeros in a two
frame period (512 bits). If one, the criteria is less than three zeros in each of two
consecutive double-frame periods (512 bits per double-frame).
6
MFSEL
(0)
Multiframe Select. This bit determines which receive multiframe signal (CRC-4 or
signalling) the RxMF (pin 42 in PLCC, 23 in MQFP) signal is aligned with. If zero,
RxMF is aligned with the receive signalling multiframe. If one, RxMF is aligned with
the receive CRC-4 multiframe.
5
NBTB
(0)
National Bit Transmit Buffer. If one, the transmit NFAS signal originates from the
transmit national bit buffer; if zero, the transmit NFAS signal originates from the
TNU4-8 bits of page 01H, address 12H.
4 - 0 Sa4 - Sa8 A one selects the corresponding Sa bits of the NFA signal for 4, 8, 12, 16 or 20
(00000) kbits/sec. data link channel. Data link (DL) selection will function in termination mode
only; in transmit transparent mode Sa4 is automatically selected - see TxTRSP
control bit of page 01H, address 11H. If zero, the corresponding bits of transmit nonframe alignment signal are programmed by the Non-Frame Alignment Control Word
(page 01H, address 12H).
Table 13 - Multiframe National Bit Buffer and DL Selection Word (Page 01H, Address 10H)
Bit
Name
Functional Description
7
TIU0
(0)
Transmit International Use Zero. When CRC-4 operation is disabled (CSYN=1),
this bit is transmit on the PCM 30 2048 kbit/sec. link in bit position one of time-slot
zero of frame-alignment frames. It is reserved for international use and should
normally be kept at one. If CRC processing is used, i.e., CSYN =0, this bit is ignored.
6
CRCM
(0)
CRC-4 Modification. If one, activates the CRC-4 remainder modification function
when the device is in transparent mode. The received CRC-4 remainder is modified
to reflect only the changes in the transmit DL. If zero, time slot zero data from DSTi
will not be modified in transparent mode.
5
RST
(0)
Reset. When this bit is changed from zero to one the device will reset to its default
mode. See the Reset Operation section for the default settings.
4
ARAI
(0)
Automatic RAI Operation. If zero, the Remote Alarm Indication bit (the A bit) will
function automatically. That is, RAI=0 when basic synchronization has been
acquired and RAI=1 when basic synchronization has not been acquired. If one,
the remote alarm indication bit is controlled through the TALM bit of the transmit
Non-Frame Alignment Control Word.
3
AUTY
(0)
Automatic Y-Bit Operation. If zero, the Y-bit of the transmit multiframe alignment
signal will report the multiframe alignment status to the far end i.e., zero - multiframe
alignment acquired, one - lost. If one, the Y-bit is under the manual control of the
Transmit Multiframe Alignment Control Word.
Table 14 - Mode Selection Control Word
(Page 01H, Address 11H)
38
Zarlink Semiconductor Inc.
MT9075B
2
Data Sheet
TxTRSP Transmit Transparent Mode. If one, the MT9075B is in transmit transparent mode.
No framing or signaling is imposed on the data transmit from DSTi onto the line. If
(0)
zero, it is in termination mode.
1
CSYN
(0)
CRC-4 Synchronization. If zero, basic CRC-4 synchronization processing is
activated, and TIU0 bit and TIU1 bit programming will be overwritten. If one, CRC-4
synchronization is disabled, the first bits of channel 0 are used as international use
bits and are programmed by TIU0 and TIU1.
0
AUTC
(0)
Automatic CRC-interworking. If zero, automatic CRC-interworking is activated. If
one, it is deactivated. See Framing Algorithm section for a detail description.
Table 14 - Mode Selection Control Word
(Page 01H, Address 11H)
Bit
Name
7
TIU1
(1)
6
---
5
TALM
(1)
4 -0
Functional Description
Transmit International Use One. When CRC-4 operation is disabled (CSYN=1), this
bit is transmit on the PCM 30 2048 kbit/sec. link in bit position one of time-slot zero of
non-frame-alignment frames. It is reserved for international use and should normally
be kept at one. If CRC processing is used, i.e., CSYN =0, this bit is ignored.
Unused. Set low for normal operation.
Transmit Remote Alarm. This bit is transmitted on the PCM 30 2048 kbit/sec. link in
bit position three (A bit) of time slot zero of NFAS frames. It is used to signal an alarm
to the remote end of the PCM 30 link (one - alarm, zero - normal). This control bit is
ignored when ARAI is zero (page 01H, address 11H).
TNU4-8 Transmit National Use Four to Eight (Sa4 - Sa8). These bits are transmitted on the
(11111) PCM 30 2048 kbit/sec. link in bit positions four to eight of time slot zero of the NFA
frame, if selected by Sa4 - Sa8 control bits of the DL selection word (page 01H,
address 10H).
Table 15 - NFA Control Word
(page 01H, Address 12H)
39
Zarlink Semiconductor Inc.
MT9075B
Bit
7 -4
Name
Data Sheet
Functional Description
TMA1-4 Transmit Multiframe Alignment Bits One to Four. These bits are
transmitted on the PCM 30 2048 kbit/sec. link in bit positions one to four
(0)
of time slot 16 of frame zero of every signalling multiframe. These bits
are used by the far end to identify specific frames of a signalling
multiframe. TMA1-4 = 0000 for normal operation.
3
X1
(1)
This bit is transmitted on the PCM 30 2048 kbit/sec. link in bit position
five of time slot 16 of frame zero of every multiframe. X1 is normally set
to one.
2
Y
(1)
This bit is transmitted on the PCM 30 2048 kbit/sec. link in bit position six
of time slot 16 of frame zero of every multiframe. It is used to indicate the
loss of multiframe alignment to the remote end of the link. If one - loss of
multiframe alignment; if zero - multiframe alignment acquired. This bit is
ignored when AUTY is zero (page 01H, address 11H).
1-0
X2, X3
(11)
These bits are transmitted on the PCM 30 2048 kbit/sec. link in bit
positions seven and eight respectively, of time slot 16 of frame zero of
every multiframe. X2 and X3 are normally set to one.
Table 16 - Transmit MF Alignment Signal
(Page 01H, Address 13H)
Bit
Name
Functional Description
7
HDLC0
(0)
HDLC0 Select. If one, then HDLC0 is connected to the data link on
selected Sa bits at a rate of 4, 8, 12, 16 or 20 kbits/sec. If zero, HDLC0
is deselected and all HDLC0 interrupts are masked.
6
HDLC1
(0)
HDLC1 Select. If one, then HDLC1 is connected to time slot 16 in CCS
mode. If zero, HDLC1 is deselected and all HDLC1 interrupts are
masked.
5
4-0
RxTRSP Receive Transparent Mode. When this bit is set to one, the framing
function is disabled on the receive side. Data coming from the receive
(0)
line passes through the slip buffer and drives DSTo with an arbitrary
alignment. When zero, the receive framing function operates normally.
---
Unused.
Table 17 - HDLC Selection Word
(Page 01H, Address 14H)
40
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
---
6
MLBK
(0)
Metallic Loopback. If one, then the external RRTIP and RRING signals are
isolated from the receiver, and TTIP and TRING are internally connected to
the receiver analog input instead. If zero, metallic loopback is disabled.
5
HDB3
(0)
High Density Bipolar 3 Encoding. If zero, HDB3 encoding is enabled in
the transmit direction. If one, AMI signal without HDB3 encoding is
transmitted. HDB3 is always decoded in the receive direction.
4
MFRF
(0)
Multiframe Reframe. If one, for at least one frame, and then cleared the
MT9075B will initiate a search for a new signalling multiframe position.
Reframing function is activated on the one-to-zero transition of the MFRF
bit.
3
DLBK
(0)
Digital Loopback. If one, then the digital stream to the transmit LIU is
looped back in place of the digital output of the receive LIU. Data coming out
of DSTo will be a delayed version of DSTi. If zero, this feature is disabled.
2
RLBK
(0)
Remote Loopback. If one, then all bipolar data received on RRTIP/RRING
are directly routed to TTIP/TRING on the PCM 30 side of the MT9075B. If
zero, then this feature is disabled.
1
SLBK
(0)
ST-BUS Loopback. If one, then all time slots of DSTi are connected to
DSTo on the ST-BUS side of the MT9075B. If zero, then this feature is
disabled. See Loopbacks section.
0
PLBK
(0)
Payload Loopback. If one, then all time slots received on RTIP/RRING are
connected to TTIP/TRING on the ST-BUS side of the MT9075B (this
excludes time slot zero). If zero, then this feature is disabled.
Unused.
Table 18 - Coding and Loopback Control Word
(Page 01H, Address 15H)
41
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
TAIS
(0)
Transmit Alarm Indication Signal. If one, an all ones signal is transmitted. TAIS=0 for normal
operation.
6
TAIS0
(0)
Transmit AIS Time Slot Zero. If one, an all ones signal is transmitted in time slot zero. If zero,
time slot zero functions normally.
5
TAIS16
(0)
Transmit AIS Time Slot 16. If one, an all ones signal is transmitted in time slot 16. If zero, time
slot functions normally.
4
TE
(0)
Transmit E bits. When CRC-4 synchronization is achieved, the E-bits transmit the received
CRC-4 comparison results to the distant end of the link, as per G.704. That is, when zero and
CRC-4 synchronization is lost, the transmit E-bits will be zero. If one, and CRC-4
synchronization is lost the transmit E-bits will be one.
3
REFRM
(0)
Reframe. If one for at least one frame, and then cleared, the device will initiate a search for a
new basic frame position. Reframing function is activated on the one-to-zero transition of the
REFRM bit.
2
64KSEL 64 KHz Select. If one, a 64 KHz signal divided down from the extracted received 2048 kbit/sec.
clock is output on RxFP/Rx64KCK (pin 47 in PLCC, 35 in MQFP). If zero that pin outputs an 8
(0)
KHz signal derived from the extracted clock.
1
DSToDE DSTo Data Enable. If zero, DSTo is enabled. If one, DSTo will be tristated if one of the
following conditions exists: LIU loss of signal, loss of terminal frame sync (SYNC=1), loss of
(0)
CRC4 sync (CRCSYN=1) or AIS.
0
CSToDE CSTo Data Enable. If zero, CSTo is enabled. If one, CSTo will be tristated if one of the
following conditions exists: loss of multiframe sync (MFSYNC=1), or AIS16 =1
(0)
Table 19 - Transmit Alarm Control Word
(Page 01H, Address 16H)
42
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
---
6
PRBSO
(0)
PRBS Counter Overflow Interrupt. When unmasked (PRBSO = 1), an
interrupt is initiated on overflow of PRBS counter (page 04H, address 10H)
from FFH to 0H. Interrupt vector = 00000010.
5
PRBSI
(0)
PRBS Interrupt. When unmasked (PRBSI = 1), an interrupt is initiated on a
single PRBS detection error. Interrupt vector = 00000010.
4
SanibI
(0)
Changed Sa Nibble Interrupt. When unmasked (SanibI = 1), an interrupt is
generated upon detection of a change of state in any of received Sa nibbles
(nibble Sa5, nibble Sa6, nibble Sa7 or nibble Sa8). Interrupt vector = 00000010.
3
SabitI
(0)
Changed Sa Bit Interrupt. When unmasked (SabitI = 1), an interrupt is
generated upon detection of a change of state in any of received Sa bits (Sa5,
Sa6, Sa7 or Sa8). Interrupt vector = 00000010.
2
C8Sa6I
(0)
Eight Consecutive Sa6 Nibble Interrupt. When unmasked (C8Sa6I = 1), an
interrupt is generated upon detection of the eighth consecutive Sa6 nibble with
the same pattern. Interrupt vector = 00000010.
1
Sa6I
(0)
Changed Sa6 Nibble Interrupt. When unmasked (Sa6I = 1), an interrupt is
generated upon detection of a change of state in received Sa6 nibbles.
Interrupt vector = 00000010.
0
Sa5I
(0)
Changed Sa5 Bit Interrupt. When unmasked (Sa5I =1), an interrupt is
generated upon detection of a change of state in the received Sa5 bit. Interrupt
vector = 00000010.
Unused.
Table 20 - National Use Bit Interrupt Mask Word
(Page 01H, Address 19H)
43
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
7
ODE
(0)
Output Data Enable. If one, the DSTo and CSTo output drivers
function normally. When low, DSTo and CSTo will be tristated.
Note: When ODE =1, DSTo and CSTo can be individually tristated by
DSToDE and CSToDE (page 01H, address 16H) respectively.
6
SPND
(0)
Suspend Interrupts. If one, the IRQ output (pin 12 in PLCC, 85 in
MQFP) will be in a high-impedance state and all interrupts will be
ignored. If zero, the IRQ output will function normally.
5
INTA
(0)
Interrupt Acknowledge. A zero-to-one or one-to-zero transition will
clear any pending interrupt and make IRQ high.
4
TxCCS
(0)
Transmit Common Channel Signalling. If one, the transmit section of
the device is in common channel signalling (CCS) mode. If zero, it is in
Channel Associated Signalling (CAS) mode.
3
RPSIG
(0)
Register Programmed Signalling. If one, the transmit CAS signalling
will be controlled by programming page 05H. If zero, the transmit CAS
signalling will be controlled through the CSTi stream.
2
CNTCLR
Counter Clear. If one, all status counters are cleared and held low.
Zero for normal operation.
(0)
Functional Description
1
MSN
(0)
Most Significant Signalling Nibble. If one, the CSTo and CSTi
channel associated signalling nibbles will be valid in the most
significant portion of each ST-BUS time slot. If zero, the CSTo and
CSTi channel associated signalling nibbles will be valid in the least
significant portion of each ST-BUS time slot.
0
64KCCS
64 Kbits/s Common Channel Signalling. If one, common channel
signalling information is sourced from CSTi, and common channel
signalling information is clocked out of CSTo. The transmit clock is an
internal clock. This 64 KHz clock is divided down from C4b and is
synchronous with the STBUS channel boundaries. The rising edges of
the clock occur between channels 1 and 2; 5 and 6; 9 and 10; 13 and
14; 17 and 18; 21 and 22; 25 and 26; 29 and 30. The receive clock is
synchronous with the same channel times, but derived from the
extracted clock timebase. The CCS receive clock is driven out on
Rx64KCK (pin 47 in PLCC, 35 in MQFP) when this bit is set. If zero
CSTi and CSTo have 2.048 mb/s bit rates and operate as per Tables
66 to 71.
(0)
Table 21 - Interrupt, Signalling and BERT Control Word (Page 01H, Address 1AH
44
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
SYNI
(0)
Synchronization Interrupt. When unmasked (SYNI = 0) an interrupt is
initiated when a loss of basic frame synchronization condition exists.
Interrupt vector = 10000000.
6
RAII
(0)
Remote Alarm Indication Interrupt. When unmasked (RAII = 0) a
received RAI will initiate an interrupt. Interrupt vector = 01000000.
5
AISI
(0)
Alarm Indication Signal Interrupt. When unmasked (AISI = 0) a received
AIS will initiate an interrupt. Interrupt vector = 01000000.
4
AIS16I
(0)
Channel 16 Alarm Indication Signal Interrupt. When unmasked (AIS16I
= 0), a received AIS16 will initiate an interrupt. Interrupt vector =
01000000.
3
LOSI
(0)
Loss of Signal Interrupt. When unmasked (LOSI = 0) an interrupt is
initiated when a loss of signal condition exists. Interrupt vector =
01000000.
2
FERI
(0)
Frame Error Interrupt. When unmasked (FERI = 0), an interrupt is
initiated when an error in the frame alignment signal occurs. Interrupt
vector = 00100000.
1
BPVO
(0)
Bipolar Violation Counter Overflow Interrupt. When unmasked (BPVO
= 0), an interrupt is initiated when the bipolar violation error counter
changes form FFFFH to 0H. Interrupt vector = 00010000.
0
SLPI
(0)
SLIP Interrupt. When unmasked (SLPI = 0), an interrupt is initiated when
a controlled frame slip occurs. Interrupt vector = 00000100.
Table 22 - Interrupt Mask Word Zero
(Page 01H, Address 1BH)
45
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
EBI
(0)
Receive E-bit Interrupt. When unmasked an interrupt is initiated when a
receive E-bit indicates a remote CRC-4 error. 1 - unmasked, 0 - masked.
Interrupt vector = 00100000.
6
CRCI
(0)
CRC-4 Error Interrupt. When unmasked an interrupt is initiated when a
local CRC-4 error occurs. 1 - unmasked, 0 - masked. Interrupt vector =
00100000.
5
CEFI
(0)
Consecutively Errored FASs Interrupt. When unmasked an interrupt is
initiated when two consecutive errored frame alignment signals are
received. 1 - unmasked, 0 - masked. Interrupt vector = 00100000.
4
BPVI
(0)
Bipolar Violation Interrupt. When unmasked an interrupt is initiated when
a bipolar violation error occurs. 1 - unmasked, 0 - masked. Interrupt vector
= 00100000.
3
RCR0I
(0)
RAI and Continuous CRC Error Interrupt. When unmasked an interrupt
is initiated when the received A bit has been one, and the received E bits
have been zero, continuously for greater than 10 milliseconds (see page
04H, address 19H) 1- unmasked, 0 - masked. Interrupt vector = 00100000.
2
RCR1I
(0)
RAI and Continuous CRC Error Interrupt. When unmasked an interrupt
is initiated when the received A bit had been set, and the received E bits
were low, continuously for greater than 10 milliseconds, but less than 450
milliseconds (see page 04H, address 19H). 1 - unmasked, 0 - masked.
Interrupt vector = 00100000.
1
BERI
(0)
Bit Error Interrupt. When unmasked an interrupt is initiated when a bit
error occurs. 1 - unmasked, 0 - masked. Interrupt vector = 00100000.
0
SIGI
(0)
Signalling (CAS) Interrupt. When unmasked and any of the receive ABCD
bits of any channel changes state an interrupt is initiated. 1 - unmasked, 0 masked. Interrupt vector = 00000001
Table 23 - Interrupt Mask Word One
(Page 01H, Address 1CH)
46
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
EBOI
(0)
Receive E-bit Counter Overflow Interrupt. When unmasked an interrupt
is initiated when the E-bit error counter overflows. 1 - unmasked, 0 masked. Interrupt vector = 00010000.
6
CRCOI
(0)
CRC-4 Error Counter Overflow Interrupt. When unmasked an interrupt is
initiated when the CRC-4 error counter overflows. 1 - unmasked, 0 masked. Interrupt vector = 00010000.
5
CALNI
(0)
CRC-4 Alignment Interrupt. When unmasked an interrupt is initiated when
the CALN status bit of page 03H, address 12H changes state. 1 unmasked, 0 - masked. Interrupt vector = 00001000.
4
FEROI
(0)
Frame Alignment Signal Error Counter Overflow Interrupt. When
unmasked an interrupt is initiated when the frame alignment signal error
counter overflows. 1 - unmasked, 0 - masked. Interrupt vector = 00010000.
3
JAI
(0)
Jitter Attenuation Interrupt. When unmasked, an interrupt will be initiated
when the jitter attenuator FIFO comes within four bytes of an overflow or
underflow condition. 1 - unmasked, 0 - masked. Interrupt vector =
00000100.
2
BEROI
(0)
Bit Error Counter Overflow Interrupt. When unmasked (BERO = 1), an
interrupt is initiated when the bit error counter overflows. Interrupt vector =
00010000.
1
AUXPI
(0)
Auxiliary Pattern Interrupt. When unmasked (AUXPI = 1), an interrupt is
initiated when the AUXP status bit of page 03H, address 15H goes high.
Interrupt vector = 01000000.
0
CMFOI
(0)
Receive CRC-4 Multiframe Counter Overflow Interrupt. When unmasked
(CMFO = 1), an interrupt is initiated when the CRC-4 multiframe counter
overflows. Interrupt vector = 00010000.
Table 24 - Interrupt Mask Word Two
(Page 01H, Address 1DH)
47
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
MFSYI
(0)
Multiframe Synchronization Interrupt. When unmasked (MFSYI = 1), an
interrupt is initiated when multiframe synchronization is lost. Interrupt vector =
10000000.
6
CSYNI
(0)
CRC-4 Multiframe Synchronization Interrupt. When unmasked (CSYNI =
1), an interrupt is initiated when CRC-4 multiframe synchronization is lost.
Interrupt vector = 10000000.
5
---
Unused.
4
YI
(0)
Remote Signalling Multiframe Alarm Interrupt. When unmasked (YI = 1),
an interrupt is initiated when a remote signalling multiframe alarm signal is
received. Interrupt vector = 10000000.
3
1SECI
(0)
One Second Status Interrupt. When unmasked (1SECI = 1), an interrupt is
initiated when the 1SEC status bit (page 03H, address 12H, bit 7) changes
from zero to one. Interrupt vector = 00001000.
2
T1I
(0)
T1 Timer Interrupt. When unmasked (T1I = 1), an interrupt is initiated when
the T1 timer bit (page 03H, address 12H, bit 5) changes from zero to one.
Interrupt vector = 00001000.
1
T2I
(0)
T2 Timer Interrupt. When unmasked (T2I = 1), an interrupt is initiated when
the T2 timer bit (page 03H, address 12H, bit 4) changes from zero to one.
Interrupt vector = 00001000.
0
---
Unused
Table 25 - Interrupt Mask Work Three
(Page 01H, Address 1EH)
48
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7-4
--(0000)
Unused. Set low for normal operation.
3
CTXP
(0)
Custom Transmit Pulse Level. A zero means that the transmit pulse level is
determined by the bits TX2-0 listed in the table entry below. When CPL is a one,
the pulse level is determined by coefficients programmed in registers 1CH - 1Fh
on Page 2.
2-0
TX2-0
(0)
Transmit pulse amplitude. Select the TX2-TX0 bits according to the line type,
value of termination resistors (RT), and transformer turns ratio used
TX2 TX1 TX0 Line() RT() Xfmr
0
0
0 120
0
1:2
0
0
1 120
0
1:1
0*
1
0 120
15
1:2
0
1
1 120/75 12.1
1:2
1
0
0
75
0
1:2
1
0
1
75
0
1:1
1*
1
0
75
9.1
1:2
1
1
1 75/120 12.1
1:2
*These configurations provide the best matching characteristics.
Table 26 - Transmit Pulse Control Word
(Page 01H, Address 1FH)
49
Zarlink Semiconductor Inc.
MT9075B
Register
Address
(A4A3A2A1A0)
Data Sheet
Names
10H (Table 28)
Error and Debounce Selection Word
BPVE, CRCE, FASE, NFSE, LOSE, PERR &
DBNCE
11H
---
Unused.
12H
---
Unused.
13H (Table 29)
Access Control Word
LOS/LOF, ADSEQ & GCI/ST
14H
---
Unused.
15H
---
Unused.
16H
---
Unused.
17H
---
Unused.
18H (Table 30)
Jitter Attenuator Control Word
JAS, JAT/JAR, JFC, JFD2, JFD1, JFD0, JACL
19H (Table 31)
Receive Equalization Control Word
REDBL, REMID, REMAX
1AH
Reserved
Set all bits to zero for normal operation.
1BH
Reserved
Set all bits to zero for normal operation.
1CH (Table 32)
Custom Pulse Level 1
CPLA6 - CPLA0
1DH (Table 33)
Custom Pulse Level 2
CPLB6 - CPLB0
1EH (Table 34)
Customer Pulse Level 3
CPLC6 - CPLC0
1FH (Table 35)
Customer Pulse Level 4
CPLD6 - CPLD0
Table 27 - Master Control 2 (Page 02H)
50
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
BPVE
(0)
Bipolar Violation Error Insertion. A zero-to-one transition of this bit
inserts a single bipolar violation error into the transmit PCM 30 data. A
one, zero or one-to-zero transition has no function.
6
CRCE
(0)
CRC-4 Error Insertion. A zero-to-one transition of this bit inserts a single
CRC-4 error into the transmit PCM 30 data. A one, zero or one-to-zero
transition has no function.
5
FASE
(0)
Frame Alignment Signal Error Insertion. A zero-to-one transition of this
bit inserts a single error into the time slot zero frame alignment signal of
the transmit PCM 30 data. A one, zero or one-to-zero transition has no
function.
4
NFSE
(0)
Non-frame Alignment Signal Error Insertion. A zero-to-one transition of
this bit inserts a single error into bit two of the time slot zero non-frame
alignment signal of the transmit PCM 30 data. A one, zero or one-to-zero
transition has no function.
3
LOSE
(0)
Loss of Signal Error Insertion. If one, the MT9075B transmits an all
zeros signal (no pulses) in every PCM 30 time slot. If zero, data is
transmitted normally.
2
PERR
(0)
Payload Error Insertion. A zero-to-one transition of this bit inserts a
single error in the transmit payload. A one, zero or one-to-zero transition
has no function.
1
---
0
DBNCE
(0)
Unused.
Debounce Select. This bit selects the debounce period (1 for 14 msec.; 0
for no debounce). Note: there may be as much as 2 msec. added to this
duration because the state change of the signalling equipment is not
synchronous with the PCM 30 signalling multiframe.
Table 28 - Error and Debounce Selection Word
(Page 02H, Address 10H)
51
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7-3
--
2
LOS/LOF
(0)
Loss of Signal or Loss of Frame Selection. If one, pin LOS (pin 61 in
PLCC, 57 in MQFP) will go high when a loss of signal state exits (criteria as
per LLOS status bit on page 03H address 18H). If low, pin LOS will go high
when either a loss of signal (LLOST =1) or a loss of basic frame alignment
state exits (bit SYNC on page 03H address 10H is zero).
1
ADSEQ
(0)
Digital Milliwatt or Digital Test Sequence. If one, the A-law digital milliwatt
analog test sequence will be selected by the Per Time Slot Control bits
TTST and RTST (on page 07H and 08H). If zero, the PRBS 215-1 bit error
rate test sequence will be selected by the Per Time Slot Control bits TTST
and RTST. The PRBS generator is reset whenever this bit is set to 1.
0
GCI/ST
(0)
GCI or ST-BUS Frame Pulse. If one, the MT9075B will transmit or receive
a GCI frame pulse on pin F0b (pin 46 in PLCC, 34 in MQFP). If zero, the
MT9075B will transmit or receive an ST-BUS frame pulse on F0b.
Unused.
Table 29 - Access Control Word
(Page 02H, Address 13H)
52
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
JAS
(0)
Jitter Attenuator Select. If one, the attenuator may be connected to either
the transmit or receive sides of the PCM 30 interface depend on bit 6 JAT/JAR. If zero, the jitter attenuator function is disabled.
6
JAT/JAR
(0)
Transmit or Receive Jitter Attenuator. If one, the jitter attenuator will
function on the transmit data. If zero, the jitter attenuator will function on the
receive data.
5
JFC
(0)
Jitter Attenuator FIFO Centre. When this bit is toggled the read pointer of
the jitter attenuator shall be centered. During centering the jitter in the JA
outputs is increased by 0.0625 U.I
4-2
JFD2- JFD0
(00)
Jitter Attenuator FIFO Depth Control Bits. These bits determine the
depth of the jitter attenuator FIFO as shown below:
1
JACL
(0)
0
---
JFD2
JFD1
JFD0
Depth (words)
0
0
0
16
0
0
1
32
0
1
0
48
0
1
1
64
1
0
0
80
1
0
1
96
1
1
0
112
1
1
1
128
Jitter Attenuator Clear bit. If one, the Jitter Attenuator, its FIFO and status
are reset. The status registers will identify the FIFO as being empty.
However, the actual bit values of the data in the JA FIFO will not be reset.
Unused.
Table 30 - Jitter Attenuator Control Word
(Page 02H, Address 18H)
53
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
REDBL
(0)
Receive Equalizer Auto Mode Disable. If one, the receive equalizer is
turned off from the auto mode. If zero, the receive equalizer is turned on
and will compensate for loop length automatically.
6
REMID
(0)
Receive Equalization Mid-range. If one and REDBL is one, the onestage equalization is enabled, which provides approximately 6 dB of
gain. If zero, REDBL or REMAX will control the receive equalization.
5
REMAX
(0)
Receive Equalization Maximum. If one, REDBL is one and REMID is
zero, the two-stage equalization is enabled, which provides
approximately 12 dB of gain. If zero, REDBL or REMID will control the
receive equalization.
4-0
---
Unused.
Table 31 - Receive Equalization Control Word
(Page 02H, Address 19H)
Bit
Name
Functional Description
7
--
6
CPLA6
(0)
Sign bit. Normalized to a positive going one, when CPLAt6 is one then the
CPLA0-CPLA5 coefficient corresponds to a positive level. When CPLA6 is
zero the coefficient is taken to indicate a negative level.
5-0
CPLA5-CPLA0
(000000)
Pulse shape coefficient for the first time slot (within one bit cell). CPLA5 is
the MSB (pulse amplitute =0.1 * CPLA[5:0]V)
Table 32 - Custom Pulse Level 1
(Page 2, Address 1CH)
Bit
Name
Functional Description
7
--
6
CPLB6
(0)
Sign bit. Normalized to a positive going one, when CPLB6 is one then the
CPLB0-CPLB5 coefficient corresponds to a positive level. When CPLB6 is zero
the coefficient is taken to indicate a negative level.
5-0
CPLB5-CPLB0
(000000)
Pulse shape coefficient for the second time slot (within one bit cell). CPLB5 is
the MSB
Table 33 - Custom Pulse Level 2
(Page 2, Address 1DH)
54
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
--
6
CPLC6
(0)
Sign bit. Normalized to a positive going one, when CPLC6 is one then the
CPLC0-CPLC5 coefficient corresponds to a positive level. When CPLA6 is
zero the coefficient is taken to indicate a negative level.
5-0
CPLC5-CPLC0
(000000)
Pulse shape coefficient for the third time slot (within one bit cell). CPLC5 is
the MSB.
Table 34 - Custom Pulse Level 1
(Page 2, Address 1CH)
Bit
Name
7
--
6
CPLD6
(0)
5-0
CPLD5-CPLD0
(000000)
Functional Description
Sign bit. Normalized to a positive going one, when CPLD6 is one then the
CPLD0-CPLD5 coefficient corresponds to a positive level. When CPLD6
is zero the coefficient is taken to indicate a negative level.
Pulse shape coefficient for the fourth time slot (within one bit cell)
Table 35 - Custom Pulse Level 4
(Page 2, Address 1FH)
55
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Master Status 1 (Page 03H)
Address
(A4A3A2A1A0)
Register
Names
10H (Table 37)
Synchronization Status Word
SYNC, MFSYNC, CRCSYN, REB1, REB2 CRCRF,
RED& CRCIWK
11H (Table 38)
Receive Frame Alignment Signal
RIU0 & RFA2-8
12H (Table 39)
Timer Status
1SEC, 2SEC, T1, T2, 400T, 8T, CALN & KLVE
13H (Table 40)
Receive Non-frame Alignment Signal
RIU1, RNFAB, RALM & RNU4-8
14H (Table 41)
Receive Multiframe Alignment Signal
RMA1-4, X1, Y, X2 & X3
15H (Table 42)
Most Significant Phase Status Word
RSLIP, RSLPD, AUXP, CEFS, RxEBC11-8
16H (Table 43)
Least Significant Phase Status Word
RxEBC7-0
17H (Table 44)
Jitter Attenuator Status Word
JACS, JACF, JAE, JAF4, JAFC, JAE4, JAF
18H (Table 45)
Receive Signal Status Word
LL, ML, SL, LLOS
19H (Table 46)
Alarm Status Word One
CRCS1, CRCS2, RFAIL, LOSS, AIS16S, AISS,
RAIS & RCRS
1AH (Table 47)
Changed Sa6 Report Word
Sa5, Sa6nibble,C8Sa6, CSa6
1BH - 1EH
---
Unused.
1FH (Table 48)
Identification Word
Set to 10101010
Word
Table 36 - Master Status 1 (Page 03H)
56
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
SYNC
Receive Basic Frame Alignment. SYNC indicates the basic frame
alignment status (1 - loss; 0 - acquired).
6
MFSYNC
Receive Multiframe Alignment. MFSYNC indicates the multiframe
alignment status (1 - loss; 0 -acquired).
5
CRCSYN
Receive CRC-4 Synchronization. CRCSYN indicates the CRC-4
multiframe alignment status (1 - loss; 0 - acquired).
4
REB1
Receive E-Bit One Status. REB1 indicates the status of the received E1
bit of the last multiframe.
3
REB2
Receive E-Bit Two Status. REB2 indicates the status of the received E2
bit of the last multiframe.
2
CRCRF
CRC-4 Reframe. A one indicates that the receive CRC-4 multiframe
synchronization could not be found within the time out period of 8 msec.
after detecting basic frame synchronization. This will force a reframe when
the maintenance option is selected and automatic CRC-4 interworking is
de-selected.
1
RED
RED Alarm. RED goes high when basic frame alignment has been lost for
at least 100 msec. This bit will be low when basic frame alignment is
acquired (I.431).
0
CRCIWK
CRC-4 Interworking. CRCIWK indicates the CRC-4 interworking status
(1 - CRC-to-CRC; 0 - CRC-to-non-CRC).
Table 37 - Synchronization Status Word
(Page 03H, Address 10H)
Bit
Name
Functional Description
7
RIU0
Receive International Use Zero. This is the bit which is received on
the PCM 30 2048 kbit/sec. link in bit position one of the frame alignment
signal. It is used for the CRC-4 remainder or for international use.
6-0
RFA2-8
Receive Frame Alignment Signal Bits 2 to 8. These bit are received
on the PCM 30 2048 kbit/sec. link in bit positions two to eight of frame
alignment signal. These bits form the frame alignment signal and
should be 0011011.
Table 38 - Receive Frame Alignment Signal
(Page 03H, Address 11H)
57
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
1SEC
One Second Timer Status. This bit changes state once every 0.5 second
and is synchronous with the 2SEC timer.
6
2SEC
Two Second Timer Status. This bit changes state once every second and
is synchronous with the 1SEC timer.
5
T1
Timer One. This bit will be high after a signal has been received, that
consists of non-normal operation frames, and persists for 100 msec. This
bit shall be low when T2 becomes high. Refer to I.431 Section 5.9.2.2.3.
4
T2
Timer Two. This bit will be high when the MT9075B acquires terminal
frame synchronization persisting for 10 msec. This bit shall be low when
non-normal operational frames are received. I.431 Section 5.9.2.2.3.
3
400T
400 msec. Timer Status. This bit changes state when the 400 msec.
CRC-4 multiframe alignment timer expires.
2
8T
8 msec. Timer Status. This bit changes state when the 8 msec. CRC-4
multiframe alignment timer expires.
1
CALN
CRC-4 Alignment. This bit changes state every msec. When CRC-4
multiframe alignment has been achieved state changes of this bit are
synchronous with the receive CRC-4 synchronization signal.
0
KLVE
Keep Alive. This bit is high when the AIS status bit (page 03H, address
19H) has been high for at least 100msec. This bit will be low when AIS
goes low (I.431).
Table 39 - Timer Status Word
(Page 03H, Address 12H)
Bit
Name
Functional Description
7
RIU1
Receive International Use 1. This bit is received on the PCM 30 2048
kbit/sec. link in bit position one of the non-frame alignment signal. It is
used for CRC-4 multiframe alignment or international use.
6
RNFAB
Receive Non-frame Alignment Bit. This bit is received on the PCM 30
2048 kbit/sec. link in bit position two of the non-frame alignment signal.
This bit should be one in order to differentiate between frame alignment
frames and non-frame alignment frames.
5
RALM
Receive Alarm. This bit is received on the PCM 30 2048 kbit/sec. link in
bit position three (the A bit) of the non-frame alignment signal. It is used as
a remote alarm indication (RAI) from the far end of the PCM 30 link (1 alarm, 0 - normal).
4-0
RNU4-8
Receive National Use Four to Eight. These bits are received on the
PCM 30 2048 kbit/sec. link in bit positions four to eight (the Sa bits) of the
non-frame alignment signal.
Table 40 - Receive Non-Frame Alignment Signal
(Page 03H, Address 13H)
58
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7-4
RMA1-4
Receive Multiframe Alignment Bits One to Four. These bits are
received on the PCM 30 2048 kbit/sec. link in bit positions one to four of
time slot 16 of frame zero of every signalling multiframe. These bit should
be 0000 for proper signalling multiframe alignment.
3
X1
Receive Spare Bit X1. This bit is received on the PCM 30 2048 kbit/sec.
link in bit position five of time slot 16 of frame zero of every signalling
multiframe.
2
Y
Receive Y-bit. This bit is received on the PCM 30 2048 kbit/sec. link in
bit position six of time slot 16 of frame zero of every signalling multiframe.
The Y bit may indicate loss of multiframe alignment at the remote end (1 loss of multiframe alignment; 0 - multiframe alignment acquired).
1-0
X2, X3
Receive Spare Bits X2 and X3. These bits are received on the PCM 30
2048 kbit/sec. link in bit positions seven and eight respectively, of time
slot 16 of frame zero of every signalling multiframe.
Table 41 - Receive Multiframe Alignment Signal
(Page 03H, Address 14H)
Bit
Name
Functional Description
7
RSLIP
Receive Slip. A change of state (i.e., 1-to-0 or 0-to-1) indicates that a
receive controlled frame slip has occurred.
6
RSLPD
Receive Slip Direction. If one, indicates that the last received frame slip
resulted in a repeated frame, i.e., system clock is faster than network
clock. If zero, indicates that the last received frame slip resulted in a lost
frame, i.e., system clock is slower than network clock. Updated on an
RSLIP occurrence basis.
5
AUXP
Auxiliary Pattern. This bit will go high when a continuous 101010... bit
stream (Auxiliary Pattern) is received on the PCM 30 link for a period of at
least 512 bits. If zero, auxiliary pattern is not being received. This pattern
will be decoded in the presence of a bit error rate of as much as 10-3.
4
CEFS
Consecutively Errored Frame Alignment Signal. This bit goes high
when the last two frame alignment signals were received in error. This bit
will be low when at least one of the last two frame alignment signals is
without error.
3-0
RxEBC
11-8
Receive Eighth Bit Count. The four most significant bit of a counter that
indicates the number of one eighth bit times there are between the STBUS frame pulse and receive frame pulse (RxFP).
Table 42 - Most Significant Phase Status Word
(Page 03H, Address 15H)
59
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7-0
RxEBC7 -0
Receive Eighth Bit Count. The 8 least significant bit of a counter that
indicates the number of one eighth bit times there are between the STBUS frame pulse and receive frame pulse (RxFP).The accuracy of the
this measurement is approximately + 1/16 (one sixteenth) of a bit.
Table 43 - Least Significant Phase Status Word
(Page 03H, Address 16H)
Bit
Name
Functional Description
7
JACS
Jitter Attenuated Clock Slow. If one it indicates that the dejittered clock
period is increased by 1/16 UI. If zero the clock is at normal speed.
6
JACF
Jitter Attenuated Clock Fast. If one it indicates that the dejittered clock
period is decreased by 1/16 UI. If zero the clock is at normal speed.
5
JAE
Jitter Attenuator FIFO Empty. If one it indicates that the JA FIFO is
empty.
4
JAF4
Jitter Attenuator FIFO with 4 Full Locations. If one it indicates that the
JA FIFO has at least 4 full locations.
3
JAFC
Jitter Attenuator Center Full. If one it indicates that the JA FIFO is at
least half full.
2
JAE4
Jitter Attenuator FIFO with 4 Empty Locations. If one it indicates that
the JA FIFO has at most 4 empty locations.
1
JAF
0
---
Jitter Attenuator FIFO Full. If one it indicates that the JA FIFO is full.
Unused
Table 44 - Jitter Attenuator Status Word
(Page 03H, Address 17H)
60
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
LL
Long Loop. This bit is one when the line signal has an amplitude so
attenuated as to require substantial equalization for data recovery.
6
ML
Medium Loop. This bit is one when the line signal has an amplitude so
attenuated as to require some equalization for data recovery.
5
SL
Short Loop. This bit is one when the line signal has an amplitude with
minimal attenuation.
4
LLOS
LIU Loss of Signal Indication. This bit will be one when the received
signal amplitude is more than 20 dB below the nominal value for a period
of at least 1 msec. This bit will be zero for normal operation.
3-0
---
Unused
Table 45 - Receive Signal Status Word
(Page 03H, Address 18H)
Bit
Name
Functional Description
7
CRCS1
Receive CRC Error Status One. If one, the evaluation of the last received submultiframe 1
resulted in an error. If zero, the last submultiframe 1 was error free. Updated on a
submultiframe 1 basis.
6
CRCS2
Receive CRC Error Status Two. If one, the evaluation of the last received submultiframe 2
resulted in an error. If zero, the last submultiframe 2 was error free. Updated on a
submultiframe 2 basis.
5
RFAIL
Remote CRC-4 Multiframe Generator/Detector Failure. If one, each of the previous five
seconds have an E-bit error count of greater than 989, and for this same period the receive
RAI bit was zero (no remote alarm), and for the same period the SYNC bit was equal to
zero (basic frame alignment has been maintained). If zero, indicates normal operation.
4
LOSS
Loss of Signal Status Indication. If one, indicates the presence of a loss of signal
condition. If zero, indicates normal operation. A loss of signal condition occurs when 127
consecutive bit periods are zero. A loss of signal condition terminates when an average
ones density of at least 12.5% has been received over a period of 127 contiguous pulse
positions starting with a pulse.
3
AIS16S
Alarm Indication Signal 16 Status. If one, indicates an all ones alarm is being received in
channel 16. If zero, normal operation. Updated on a frame basis.
2
AISS
Alarm Indication Status Signal. If one, indicates that a valid AIS or all ones signal is being
received. If zero, indicates that a valid AIS signal is not being received. The criteria for AIS
detection is determined by the control bit ASEL (page 01H, address 10H).
1
RAIS
Remote Alarm Indication Status. If one, there is currently a remote alarm condition (i.e.,
received A bit is one). If zero, normal operation. Updated on a non-frame alignment frame
basis.
0
RCRS
RAI and Continuous CRC Error Status. If one, there is currently an RAI and continuous
CRC error condition. If zero, normal operation. Updated on a multiframe basis.
Table 46 - Alarm Status Word One
(Page 03H, Address 19H)
61
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
Sa5
6-3
Sa6nibble
2
---
1
C8Sa6
Eight Consecutive Sa6 nibbles. Upon detection of the eighth consecutive
Sa6 nibble with the same pattern, this bit goes high. It is cleared once this
register is read.
0
CSa6
Changed Sa6 nibble. Upon detection of a change of state within the
received Sa6 nibbles, this bit goes high. It is cleared once this register is
read.
Sa5 Bit (latched by C8Sa6). It is cleared once this register is read.
Sa6 Nibble (latched by C8Sa6). It is cleared once this register is read.
Unused
Table 47 - Changed Sa6 Report Word
(Page 03H, Address 1AH)
Bit
Name
7-0
ID7-0
Functional Description
Contains device code 10101010.
Table 48 - Identification Word
(Page 03H, Address 1FH)
Master Status 2 (Page 04H)
Address
(A4A3A2A1A0)
Register
Names
10H (Table 50)
PRBS Error Counter
PS7-0
11H (Table 51)
CRC Multiframe counter for PRBS
PSM7-0
12H (Table 52)
Interrupt Vector
IV7 - IV0
13H (Table 53)
E-bit Error Counter Ebt
EC9-EC8
14H (Table 54)
E-bit Error Counter Ebt
EC7-EC0
15H (Table 55)
Jitter FIFO Counter
JFC7-JFC0
16H (Table 56)
Overflow Reporting Latch
PRBSO, FEBEO, JFO, LBO, BERO, EFO,
BPVO, CCO
17H (Table 57)
Loss of Basic Synchronization Counter
LBF7-LBF0
18H (Table 58)
Bit Error Rate Counter
BR7 - BR0
19H (Table 59)
RAI and Continuous CRC Error Bits
RCRC1 - RCRC0
1AH (Table 60)
Errored Frame Alignment Signal Counter
EFAS7 - EFAS0
1BH (Table 61)
Alarm Reporting Latch
RAI, AIS, AIS16, LOS, AUXP, MFALM,
RSLIP
Table 49 - Master Status (Page 04H)
62
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
1CH (Table 62)
Most Significant Bipolar Violation Error
Counter
BPV15 - BPV8
1DH (Table 63)
Least Significant Bipolar Violation Error
Counter
BPV7 - BPV0
1EH (Table 64)
CRC-4 Error Counter CEt
CC9-CC8
1FH (Table 65)
CRC-4 Error Counter CEt
CC7 - CC0
Table 49 - Master Status (Page 04H)
Bit
Name
Functional Description
7-0
PS7-0
PRBS Error Counter. This counter is incremented for each PRBS error
detected on any of the receive channels connected to the PRBS error
detector.
Table 50 - PRBS Error Counter
(Page 04H, Address 10H)
Bit
Name
Functional Description
7-0
PSM7-0
CRC Multiframe Counter for PRBS. This counter is incremented for each
received CRC submultiframe. It is cleared when the PRBS Error Counter is
written to.
Table 51 - CRC Multiframe Counter for PRBS
(Page 04H, Address 11H)
Bit
Name
Functional Description
7 - 0 IV7 -IV0 Interrupt Vector. The interrupt vector status word contains an interrupt vector that indicates
the category of the last interrupt as shown in Table 11.
Table 52 - Interrupt Vector Status Word
(Page 04H, Address 12H)
Bit
Name
7-2
---
1-0
EC9-8
Functional Description
Unused
E Bit Error Counter. The most significant 2 bits of the E bit error counter.
Table 53 - E bit Error Counter
(Page 04H, Address 13H)
63
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7-0
EC7-0
E bit Error Counter. The least significant eight bits of the E-bit error
counter.
Table 54 - E bit Error Counter
(Page 04H, Address 14H)
Bit
Name
Functional Description
7-0
JFC7
JFC0
Jitter FIFO Counter. This is an 8 bit counter that is incremented when the
FIFO read pointer comes within 4 words of an underflow or overflow
condition. During this time the read clock will abruptly slow-down or speedup to avoid an overflow or underflow condition.
Table 55 - Jitter FIFO Counter
(Page 04H, Address 15H)
Bit
Name
Functional Description
7
PRBSO
PRBS Error Counter Overflow. This bit is set to one when the PRBS Error
Counter (page 04H address 10H) overflows. It is cleared when this register
is read.
6
FEBEO
E Bit Counter Overflow. This bit is set to one when the E bit Counter (page
04H, address 13H & 14H) overflows. It is cleared when this register is read.
5
JFO
Jitter Attenuator FIFO Counter Overflow. This bit is set to one when the
Jitter Attenuator FIFO Counter (page 04H, address 15H) overflows. It is
cleared when this register is read.
4
LBO
Lost of Basic Frame Synchronization Counter Overflow. This bit is set
to one when the Loss of Basic Frame Synchronization Counter (page 04H
address 17H) overflows. It is cleared when this register is read.
3
BERO
Bit Error Rate Counter Overflow. This bit is set to one when the Bit Error
Rate Counter (page 04H, address 18H) overflows. It is cleared when this
register is read.
2
EFO
Errored Frame Alignment Signal Counter Overflow. This bit is set to one
when the Errored Frame Alignment Signal Counter (page 04H, address
1AH) overflows. It is cleared when this register is read.
1
BPVO
Bipolar Violation Counter Overflow. This bit is set high when the Bipolar
Violation Counter (page 04H, address 1CH & 1DH) overflows. It is cleared
when this register is read.
0
CCO
CRC Error Counter Overflow. This bit is set high when the CRC Error
Counter (page 04H, address 1EH & 1FH) overflows. It is cleared when this
register is read.
Table 56 - Overflow Reporting Latch
(Page 04H, Address 16H)
64
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7-0
LBF7
LBF0
Loss of Basic Frame Synchronization Counter. This eight bit counter will
be incremented once for every 125 microsecond period in which basic
frame synchronization is lost. It will be cleared by a basic frame
synchronization to loss of basic frame synchronization state transition.
Table 57 - Loss of Basic Synchronization Counter
(Page 04H, Address 17H)
Bit
Name
Functional Description
7-0
BR7
BR0
Bit Error Rate Counter. An eight bit counter that contains the total
number of errors in the frame alignment signal.
Table 58 - Bit Error Rate Counter
(Page 04H, Address 18H)
Bit
Name
Functional Description
7-2
---
1
RCRC1
RAI and Continuous CRC Error bit 1. This bit goes high when received A
(RAI) bits were high and receive E bits were low, continuously, for more
than 10 milliseconds, but less than 450 milliseconds. This bit is cleared
when read.
0
RCRC0
RAI and Continuous CRC Error Bit 0. This bit goes high when received
A (RAI) bits are high and receive E bits are low, continuously, for more
than 10 milliseconds.
Unused
Table 59 - RAI With CRC Error Word
(Page 04H, Address 19H)
Bit
Name
Functional Description
7-0
EFAS7
EFAS0
Errored FAS Counter. An 8 bit counter that is incremented once for every
receive frame alignment signal that contains one or more errors.
Table 60 - Errored Frame Alignment Signal
Counter (Page 04H, Address 1AH)
65
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
RAI
Remote Alarm Indication. This bit is set to one in the event of receipt of a
remote alarm, i.e. A(RAI) = 1. It is cleared when the register is read.
6
AIS
Alarm Indication Signal. This bit is set to one in the event of receipt of an
all ones alarm. It is cleared when the register is read.
5
AIS16
AIS Time Slot 16 Alarm. This bit is set to one in the event of receipt of an
all ones alarm in the time slot 16. It is cleared when the register is read.
4
LOS
Loss of Signal. This bit is set to one in the event of loss of received signal.
It is cleared when the register is read.
3
AUXP
Auxiliary Alarm. This bit is set to one in the event of receipt of the auxiliary
alarm pattern. It is cleared when the register is read.
2
MFALM
Multiframe Alarm. This bit is set to one in the event of receipt of a
multiframe alarm. It is cleared when the register is read.
1
RSLIP
Received Slip. This bit is set to one in the event of receive elastic buffer
slip. It is cleared when the register is read.
0
---
Unused.
Table 61 - Alarm Reporting Latch
(Page 04H, Address 1BH)
Bit
Name
Functional Description
7-0
BPV15
BPV8
BPV Counter. The most significant eight bits of a 16 bit counter that is
incremented once for every bipolar violation error received.
Table 62 - Most Significant Bits of the BPV Counter (Page 04H, Address 1CH)
Bit
Name
Functional Description
7-0
BPV7
BPV0
BPV Counter. The least significant eight bits of a 16 bit counter that is
incremented once for every bipolar violation error received.
Table 63 - Least Significant Bits of the PBV Counter (Page 04H, Address 1DH)
66
Zarlink Semiconductor Inc.
MT9075B
Bit
Name
7-2
---
1-0
CC9-CC8
Data Sheet
Functional Description
Unused
CRC-4 Error Counter. The most significant eight bits of the CRC-4 error
counter.
Table 64 - CRC-4 Error Counter
(Page 04H, Address 1EH)
Bit
Name
Functional Description
7-0
CC7CC0
CRC-4 Error Counter. The least significant eight bits of the CRC-4 error
counter.
Table 65 - CRC-4 Error Counter
(Page 04H, Address 1FH)
Per Channel Transmit Signalling (Page 05H)
Table 62 describes Page 05H, addresses 11H to 1FH, which contains the Transmit Signalling Control Words for
PCM 30 channels 1 to 15 and 16 to 30. Control of these bits is through the processor or controller port when page
01H, address 1AH, bit 3, RPSIG = 1.
Bit
Name
Functional Description
7-4
A(n),
B(n),
C(n),
D(n)
(1110)
Transmit Signalling Bits for Channel n. These bits are transmitted on
the PCM 30 2048 kbit/sec. link in bit positions one to four of time slot 16
in frame n (where n = 1 to 15), and are the A, B, C, D signalling bits
associated with channel n.
3-0
A(n+15),
B(n+15),
C(n+15),
D(n+15)
(0101)
Transmit Signalling Bits for Channel n + 15. These bits are
transmitted on the PCM 30 2048 kbit/sec. link in bit positions five to eight
of time slot 16 in frame n (where n = 1 to 15), and are the A, B, C, D
signalling bits associated with channel n + 15.
Table 66 - Transmit Channel Associated Signalling
(Page 05H)
Serial per channel transmit signalling control through CSTi is selected when bit RPSIG is zero. Table 63 describes
the function of CSTi time slots 1 to 15, and Table 64 describes the function of CSTi time slots 17 to 31, when page
01H, address 1CH, bit 1, MSN = 1. If MSN = 0, the signalling nibble appears at least significant bits (bits 3-0).
67
Zarlink Semiconductor Inc.
MT9075B
Bit
Name
7-4
A(n),
B(n),
C(n),
D(n)
3-0
---
Bit
Name
7-4
A(n+15),
B(n+15),
C(n+15),
D(n+15)
3-0
---
Data Sheet
Functional Description
Transmit Signalling Bits for Channel n. These bits are transmitted on
the PCM 30 2048 kbit/sec. link in bit positions one to four of time slot 16
in frame n (where n = 1 to 15), and are the A, B, C, D signalling bits
associated with channel n.
Unused.
Table 67 - Transmit CAS Channels 1 to 15 (CSTi)
Functional Description
Transmit Signalling Bits for Channel n + 15. These bits are
transmitted on the PCM 30 2048 kbit/sec. link in bit positions five to eight
of time slot 16 in frame n (where n = 1 to 15), and are the A, B, C, D
signalling bits associated with channel n + 15.
Unused.
Table 68 - Transmit CAS Channels 16 to 30 (CSTi)
Per Channel Receive Signalling (Page 06H)
Page 06H, addresses 11H to 1FH contain the Receive Signalling Control Words for PCM 30 channels 1 to 15 and
16 to 30.
Bit
Name
Functional Description
7-4
A(n),
B(n),
C(n),
D(n)
Receive Signalling Bits for Channel n. These bits are received on the
PCM 30 2048 kbit/sec. link in bit positions one to four of time slot 16 in
frame n (where n = 1 to 15), and are the A, B, C, D signalling bits
associated with channel n.
3-0
A(n+15),
B(n+15),
C(n+15),
D(n+15)
Receive Signalling Bits for Channel n + 15. These bits are received on
the PCM 30 2048 kbit/sec. link in bit positions five to eight of time slot 16
in frame n (where n = 1 to 15), and are the A, B, C, D signalling bits
associated with channel n + 15.
Table 69 - Receive CAS (Page 06H)
Serial per channel receive signalling status bits also appear on ST-BUS stream CSTo. Table 66 describes the
function of CSTo time slots 1 to 15, and Table 67 describes the function of CSTo time slots 17 to 31, when page
01H, address 1CH, bit 1, MSN = 1. If MSN = 0, the signalling nibble appears at least significant bits (bits 3-0).
Bit
Name
Functional Description
7-4
A(n),
B(n),
C(n),
D(n)
Receive Signalling Bits for Channel n. These bits are received on the
PCM 30 2048 kbit/sec. link in bit positions one to four of time slot 16 in
frame n (where n = 1 to 15), and are the A, B, C, D signalling bits
associated with channel n.
3-0
---
Unused - High impedance state.
Table 70 - Receive CAS Channels 1 to 15 (CSTo)
68
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7-4
A(n+15),
B(n+15),
C(n+15),
D(n+15)
Receive Signalling Bits for Channel n + 15. These bits are received on
the PCM 30 2048 kbit/sec. link in bit positions five to eight of time slot 16
in frame n (where n = 1 to 15), and are the A, B, C, D signalling bits
associated with channel n + 15.
3-0
---
Unused - High impedance state.
Table 71 - Receive CAS Channels 17 to 31 (CSTo)
Per Time Slot Control Words (Pages 07H and 08H)
The control functions described by Table 69 are repeated for each PCM-30 channel. Page 07H addresses 10H to
1FH correspond to time slots 0 to 15, while page 08H addresses 10H to 1FH correspond to time slots 16 to 31.
Page 07H Address:
Equivalent
Timeslots
PCM
30
Page 08H Address:
Equivalent
Timeslots
PCM
30
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
Table 72 - Mapping to CEPT Channels
(Page 07H and 08H)
Bit
Name
Functional Description
7
TXMSG
(0)
Transmit Message Mode. If one, the data from the corresponding
address location of Tx message mode buffer is transmitted in the
corresponding PCM 30 time slot. If zero, the data on DSTi is transmitted
on the corresponding PCM 30 time slot. Tx message mode buffer are
accessed from pages 0FH and 10H.
6
ADI
(0)
Alternate Digit Inversion. If one, the corresponding transmit time slot
data on DSTi has every second bit inverted, and the corresponding PCM
30 receive time slot has every second bit inverted. If zero, this bit has no
effect on channel data.
5
RTSL
(0)
Remote Time Slot Loopback. If one, the corresponding PCM 30
receive time slot is looped to the corresponding PCM 30 transmit time
slot. This received time slot will also be present on DSTo. If zero, the
loopback is disabled.
Table 73 - Per Time Slot Control Word
(Page 07H and 08H)
69
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
4
LTSL
(0)
Local Time Slot Loopback. If one, the corresponding transmit time slot
is looped to the corresponding receive time slot. This transmit time slot
will also be present on the transmit PCM 30 stream. If zero, this loopback
is disabled.
3
TTST
(0)
Transmit Test. If one and control bit ADSEQ (page 02H, address 13H)
is one, the A-law digital milliwatt will be transmitted in the corresponding
PCM 30 time slot. When one and ADSEQ is zero, a Pseudo-Random Bit
Sequence (PRBS 215-1) will be transmitted is the corresponding PCM 30
time slot. More than one time slot may be activated at once. If zero,
neither of these test signals will be connected to the corresponding time
slot.
2
RRST
(0)
Receive Test. If one and control bit ADSEQ (page 02H, address 13H) is
one, the A-law digital milliwatt will be transmitted in the corresponding
DSTo time slot. When one and ADSEQ is zero, a Pseudo Random Bit
Sequence (PRBS 215-1) receiver will be connected to the corresponding
time slot. This receiver circuit will synchronize to the transmit PRBS
signal and perform a bit comparison of the two sequences. If zero,
neither of these test signals will be connected to the corresponding time
slot.
1
---
Unused.
0
---
Unused.
Table 73 - Per Time Slot Control Word
(Page 07H and 08H)
One Second Status (Page 09H)
Address
(A4A3A2A1A0)
Register
Names
10H
(Table 75)
MSB Latched
E-bit Error Count
LEC9-LEC8
11H
(Table 76)
LSB Latched E-bit Error Count
LEC7-LEC0
12H
(Table 77)
Latched Errored Frame Alignment Signal
Count
LEFAS7-LEFAS0
13H
(Table 78)
MSB Latched BPV Error Count
LBPV15-LBPV8
14H
(Table 79)
LSB Latched BPV Error Count
LBPV7-LBPV0
15H
(Table 80)
MSB Latched CRC Error Count
LCC9-LCC8
16H
(Table 81)
LSB Latched CRC Error Count
LCC7-LCC0
17H - 1FH
---
Unused.
Table 74 - One Second Status (Page 09H)
70
Zarlink Semiconductor Inc.
MT9075B
Bit
Name
7-2
---
1-0
LEC9
LEC8
Data Sheet
Functional Description
Unused
Latched E bit error counter (the most significant two bits). These bits are sampled
every second by the internal one second timer.
Table 75 - Latched E-bit Error Counter
(Page 09H, Address 10H)
Bit
Name
Functional Description
7-0
LEC7
LEC0
Latched E Bit Error Counter (the least significant eight bits). These
bits are sampled every second by the internal one second timer.
Table 76 - Latched E-bit Error Counter
(Page 09H, Address 11H)
Bit
Name
Functional Description
7-0
LEFAS7
LEFAS0
Latched Errored FAS Counter. An 8 bit counter that is incremented once
for every receive frame alignment signal that contains one or more errors.
These bits are sampled every second by the internal one second timer.
Table 77 - Latched Errored Frame Alignment Signal Counter (Page 09H, Address 12H)
Bit
Name
Functional Description
7-0
LBPV15
LBPV8
Latched BPV Counter (most significant 8 bits). The BPV counter is
incremented once for every bipolar violation error received. These bits are
sampled every second by the internal one second timer.
Table 78 - Most Significant Bits of the Latched BPV Counter (Page 09H, Address 13H)
Bit
Name
Functional Description
7-0
LBPV7
LBPV0
Latched BPV Counter (least significant 8 bits). The least significant
eight bits of a 16 bit counter that is incremented once for every bipolar
violation error received. These bits are sampled every second by the
internal one second timer.
Table 79 - Least Significant Bits of the Latched BPV Counter (Page 09H, Address 14H)
71
Zarlink Semiconductor Inc.
MT9075B
Bit
Name
7-2
---
1-0
LCC9
LCC8
Data Sheet
Functional Description
Unused
Latched CRC-4 Error Counter (Bits 9 & 8). These are the most significant
two bits of the CRC-4 error counter. These bits are sampled every second
by the internal one second timer.
Table 80 - Latched CRC-4 Error Counter
(Page 09H, Address 15H)
Bit
Name
Functional Description
7-0
LCC7
LCC0
Latched CRC-4 Error Counter (Bits 7-0). These are the least significant
eight bits of the CRC-4 error counter. These bits are sampled every second
by the internal one second timer.
Table 81 - Latched CRC-4 Error Counter
(Page 09H, Address 16H)
72
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
HDLC Control and Status (Page 0BH & 0CH)
Register
Address
Name
Control (Write/Verify)
Status (Read)
10H (Table 83)
Address Recognition 1
---
Adr16-Adr10, A1en
11H (Table 84)
Address Recognition 2
---
Adr26-Adr20, A2en
12H (Table85)
& (Table 86)
TX FIFO
13H (Table 87)
HDLC Control 1
---
Adrec, RxEN, TxEN, EOP, FA, Mark-idle,
RSV, RSV
14H (Table 88)
---
HDLC Status
Intgen, Idle-Chan, RQ9, RQ8, Txstat2,
Txstat1, Rxstat2, Rxstat1
15H (Table 89)
HDLC Control 2
---
Intsel, Cycle, Tcrci, Seven, RSV, RSV,
Rxfrst, Txfrst
16H (Table 90)
Interrupt Mask
---
Ga,
EOPD,
TEOP,
FA:Txunder, RxFf, RxOvfl
EOPR,
TxFl,
17H (Table 91)
---
Interrupt Status
Ga,
EOPD,
TEOP,
FA:Txunder, RxFf, RxOvfl
EOPR,
TxFl,
18H (Table 92)
---
Rx CRC MSB
Crc15-Crc8
19H (Table 93)
---
Rx CRC LSB
Crc7-Crc0
1AH (Table 94)
TX byte count
---
Cnt7-Cnt0
1BH (Table 95)
Test Control
---
HRST, RTloop, RSV, RSV, RSV, Ftst, RSV,
Hloop
1CH (Table 96)
---
Test Status
1DH (Table 97)
HDLC Control 3
---
RFD2-0, TFD2-0
1EH (Table 98)
HDLC Control 4
---
RFFS2-0, TFLS2-0
Bit7-Bit0
RX FIFO
RXclk, TXclk, Vcrc, Vaddr
Table 82 - HDLC 0 & 1 Control and Status (Pages 0BH & 0CH)
73
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7-2
Adr16
Adr11
(000000)
A six bit mask used to interrogate the first byte of the received address.
Adr16 is the MSB.
1
Adr10
(0)
This bit is used in address comparison, if control bit Seven, bit 4 of HDLC
Control Register 2 (address 15H) is one.
0
A1en
(0)
When this bit is high, this six (or seven) bit mask is used in address
comparison of the first address byte.
If address recognition is enabled, any packet failing the address
comparison will not be stored in the RX FIFO. A1en must be high for All-call
(1111111) address recognition for single byte address. When this bit is low,
this bit mask is ignored in address comparison
Table 83 - HDLC Address Recognition Register1
(Page 0BH & 0CH, Address 10H)
Bit
7-1
0
Name
Functional Description
Ad26
Ad20
(000000)
A seven bit mask used to interrogate the second byte of the received
address. Adr26 is MSB. This mask is ignored (as well as first byte mask) if
all call address (1111111) is received.
A2en
(0)
When this bit is one, this seven bit mask is used in address comparison of
the second address byte.
If address recognition is enabled, any packet failing the address
comparison will not be stored in the Rx FIFO. A2en must be one for All-call
address recognition. When this bit is zero, this bit mask is ignored in
address comparison
Table 84 - HDLC Address Recognition Register 2 (Pages 0BH & 0CH, Address 11H)
Bit
Name
Functional Description
7-0
Bit7
Bit0
This eight bit word is tagged with the two status bits (EOP and FA) from
the Control Register 1, and the resulting 10 bit word is written to the TX
FIFO. The FIFO status is not changed immediately after a write or read
occurs. It is updated after the data and the read/write pointers have
settled.
Table 85 - TX FIFO Write Register
(Pages 0BH & 0CH, Address 12H)
74
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7-0
Bit7
Bit0
This is the received data byte read from the RX FIFO. The status bits of
this byte can be read from the status register. The FIFO status is not
changed immediately when a write or read occurs. It is updated after the
data and the read/write pointers have settled.
Table 86 - RX FIFO Read Register
(Pages 0BH & 0CH, Address 12H)
Bit
Name
Functional Description
7
Adrec
(0)
Address Recognition. When one this bit will enable address recognition.
This forces the receiver to recognize only those packets having the unique
address as programmed in the Receive Address Recognition Registers or if
the address is an All call address.
6
RxEN
(0)
Receive Enable. When one the receiver will be immediately enabled and
will begin searching for flags, Go-Aheads etc.
When zero this bit will disable the HDLC receiver after the rest of the packet
presently being received is finished. The receiver internal clock is disabled.
5
TxEN
(0)
Transmit Enable. When one the transmitter will be immediately enabled
and will begin transmitting data, if any, or go to a mark idle or interframe
time fill state.
When zero this bit will disable the HDLC transmitter after the completion of
the packet presently being transmitted. The transmitter internal clock is
disabled.
4
EOP
(0)
End Of Packet. Forms a tag on the next byte written the TX FIFO, and
when set will indicate an end of packet byte to the transmitter, which will
transmit an FCS following this byte. This facilitates loading of multiple
packets into TX FIFO. Reset automatically after a write to the TX FIFO
occurs.
3
FA
(0)
Frame Abort. Forms a tag on the next byte written to the TX FIFO, and
when set to one FA will indicate to the transmitter that it should abort the
packet in which that byte is being transmitted. Reset automatically after a
write to the TX FIFO.
2
Mark-Idle
(0)
When zero, the transmitter will be in an idle state. When one it is in an
interframe time fill state. These two states will only occur when the TX FIFO
is empty.
1-0
RSV
(00)
Reserved: Must be set to 0 for normal operation.
Table 87 - HDLC Control Register 1
(Page 0BH &0CH, Address 13H)
75
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
Intgen
Interrupt Generation. Intgen is set to 1 when an interrupt (in conjunction
with the Interrupt Mask Register) has been generated by the HDLC. This
is an asynchronous event. It is reset when the Interrupt Register is read.
6
Idle Chan
Idle Channel. This bit is set to a 1 when an idle Channel state (15 or
more ones) has been detected at the receiver. This is an asynchronous
event. Status becomes valid after the first 15 bits or the first zero is
received.
5, 4
RQ9, RQ8
Byte Status bits from RX FIFO. These bits determine the status of the
byte to be read from RX FIFO as follows:
3, 2
Txstat2, Txstat1
RQ9
RQ8
Byte Status
0
0
Packet byte.
0
1
First byte.
1
0
Last byte of a good packet.
1
1
Last byte of a bad packet.
Transmit Status. These bits indicate the status of the TX FIFO as
follows:
Txstat2
Txstat1
TX FIFO Status
0
0
TX FIFO full up to the selected status level
or more. See Table 93.
0
1
The number of bytes in the TX FIFO has
reached or exceeded the selected interrupt
threshold level. See Table 94.
1
0
TX FIFO empty.
1
1
The number of bytes in the TX FIFO is less
than the selected interrupt threshold level.
See Table 94.
Table 88 - HDLC Status Register
(Pages 0BH & 0CH, Address 14H)
76
Zarlink Semiconductor Inc.
MT9075B
1, 0
Rxstat2, Rxstat1
Data Sheet
Receive Status. These bits indicate the status of the RX FIFO as
follows:
Rxstat2
Rxstat1
RX FIFO Status
0
0
RX FIFO empty.
0
1
The number of bytes in the RX FIFO is less
than the selected threshold level. See
Table 94.
1
0
RX FIFO full up to the selected status level
or more. See Table 93.
1
1
The number of bytes in the RX FIFO has
reached or exceeded the selected interrupt
threshold level. See Table 94.
Table 88 - HDLC Status Register
(Pages 0BH & 0CH, Address 14H)
77
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
Intsel
(0)
Interrupt Selection. When one, this bit will cause bit 2 of the Interrupt
Register to reflect a TX FIFO underrun (TXunder). When zero, this
interrupt will reflect a frame abort (FA).
6
Cycle
(0)
When one, this bit will cause the transmit byte count to cycle through the
value loaded into the Transmit Byte Count Register.
5
Tcrci
(0)
Transmit CRC Inhibited. When one, this bit will inhibit transmission of the
CRC. That is, the transmitter will not insert the computed CRC onto the bit
stream after seeing the EOP tag byte. This is used in V.120 terminal
adaptation for synchronous protocol sensitive UI frames.
4
Seven
(0)
Seven Bits Address Recognition. When one, this bit will enable seven
bits of address recognition in the first address byte. The received address
byte must have bit 0 equal to 1 which indicates a single address byte is
being received.
3
RSV
(0)
Reserved, must be zero for normal operation.
2
RSV
(0)
Reserved, must be zero for normal operation.
1
Rxfrst
(0)
RX FIFO Reset. When one, the RX FIFO will be reset. This causes the
receiver to be disabled until the next reception of a flag. The status register
will identify the FIFO as being empty. However, the actual bit values in the
RX FIFO will not be reset.
0
Txfrst
(0)
TX FIFO Reset. When one, the TX FIFO will be reset. The Status Register
will identify the FIFO as being empty. This bit will be reset when data is
written to the TX FIFO. However, the actual bit values of data in the TX
FIFO will not be reset. It is cleared by the next write to the TX FIFO.
Table 89 - HDLC Control Register 2
(Pages 0BH & 0CH, Address 15H)
Bit
Name
Functional Description
7-0
Ga, EOPD, TEOP,
EOPR, TxFl, FA:
Txunder, RxFf &
RxOvfl
(000000)
This register is used with the Interrupt Register to mask out the interrupts
that are not required by the microprocessor. Interrupts that are masked out
will not produce an IRQ; however, they will set the appropriate bit in the
Interrupt Register. An interrupt is disabled when the microprocessor writes
a 0 to a bit in this register. This register is cleared on power reset.
Table 90 - HDLC Interrupt Mask Register
(Pages 0BH & 0CH, Address 16H)
78
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
GA
Go-Ahead. Indicates a go-ahead pattern was detected by the HDLC
receiver. This bit is reset after a read.
6
EOPD
End Of Packet Detect. This bit is set to one when an end of packet (EOP)
byte was written into the RX FIFO by the HDLC receiver. This can be in
the form of a flag, an abort sequence or as an invalid packet. This bit is
reset after a read.
5
TEOP
Transmit End Of Packet. This bit is set to one when the transmitter has
finished sending the closing flag of a packet or after a packet has been
aborted. This bit is reset after read.
4
EOPR
End Of Packet Read. This bit is set to one when the byte about to be read
from the RX FIFO is the last byte of the packet. It is also set to one if the
Rx FIFO is read and there is no data in it. This bit is reset after a read.
3
TxFL
TX FIFO Low. This bit is set to one when the TX FIFO is emptied below
the selected low threshold level. This bit is reset after a read.
2
FA: Txunder
Frame Abort/TX FIFO Underrun. When Intsel bit of Control Register 2 is
low, this bit is set to one when a frame abort is received during packet reception. It must be received after a minimum number of bits have been received (26) otherwise it is ignored.
When Intsel bit of Control Register 2 is one, this bit is set to one for a TX
FIFO underrun indication. If one it indicates that a read by the transmitter
was attempted on an empty Tx FIFO.
This bit is reset after a read.
1
RxFf
RX FIFO Full. This bit is set to one when the RX FIFO is filled above the
selected full threshold level. This bit is reset after a read.
0
RxOvfl
RX FIFO Overflow. A one indicates that the 128 byte RX FIFO
overflowed (i.e. an attempt to write to a 128 byte full RX FIFO). The HDLC
will always disable the receiver once the receive overflow has been
detected. The receiver will be re-enabled upon detection of the next flag,
but will overflow again unless the RX FIFO is read. This bit is reset after a
read.
Table 91 - HDLC Interrupt Status Register
(Page 0BH & 0CH, Address 17H)
Bit
Name
Functional Description
7-0
Crc15-8
The MSB byte of the CRC received from the transmitter. These bits are
as the transmitter sent them; that is, most significant bit first and inverted.
This register is updated at the end of each received packet and therefore
should be read when end of packet is detected.
Table 92 - Receive CRC MSB Register
(Pages 0BH & 0CH, Address 18H)
79
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7-0
Crc7 - 0
The LSB byte of the CRC received from the transmitter. These bits are as
the transmitter sent them; that is, most significant bit first and inverted.
This register is updated at the end of each received packet and therefore
should be read when end of packet is detected.
Table 93 - Receive CRC LSB Register
(Pages 0BH & 0CH, Address 19H)
Bit
Name
Functional Description
7-0
Cnt7 - 0
(0000
0000)
The Transmit Byte Count Register. It is used to indicate the length of the
packet about to be transmitted. When this register reaches the count of
one, the next write to the Tx FIFO will be tagged as an end of packet byte.
The counter decrements at the end of the write to the Tx FIFO. If the Cycle
bit of Control Register 2 is set high, the counter will cycle through the
programmed value continuously.
Table 94 - Transmit Byte Count Register
(Pages B & C, Address 1AH)
80
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7
HRST
(0000
0000)
HDLC Reset. When this bit is set to one, the HDLC will be reset. This is
similar to RESET being applied, the only difference being that this bit will
not be reset automatically. This bit can only be reset by writing a zero twice
to this location or applying RESET.
6
RTloop
(0)
RT Loopback. When this bit is set to one, receive to transmit HDLC
loopback will be activated. Receive data, including end of packet indication,
but not including flags or CRC, will be written to the TX FIFO as well as the
RX FIFO. When the transmitter is enabled, this data will be transmitted as
though written by the microprocessor. Both good and bad packets will be
looped back. Receive to transmit loopback may also be accomplished by
reading the RX FIFO using the microprocessor and writing these bytes,
with appropriate tags, into the TX FIFO.
5
RSV
(0)
Reserved; must be set to 0 for normal operation.
4
RSV
(0)
Reserved; must be set to 0 for normal operation.
3
RSV
(0)
Reserved; must be set to 0 for normal operation.
2
Ftst
(0)
FIFO Test. This bit when set to one allows the writing to the RX FIFO and
reading of the TX FIFO through the microprocessor to allow more efficient
testing of the FIFO status/interrupt functionality. This is done by making a
TX FIFO write become a RX FIFO write and a RX FIFO read become a TX
FIFO read. In addition, EOP/FA and RQ8/RQ9 are re-defined to be
accessible (i.e. RX write causes EOP/FA to go to RX fifo input; TX read
looks at output of TX FIFO through RQ8/RQ9 bits).
1
RSV
(0)
Reserved; must be set to 0 for normal operation.
0
---
Unused.
Table 95 - HDLC Test Control Register
(Pages 0BH & 0CH, Address 1BH)
81
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7-4
RSV
These bits are reserved.
3
RXclk
This bit represents the receiver clock generated after the RXEN control bit
is enabled, but before zero deletion is considered.
2
TXclk
This bit represents the transmit clock generated after the TXEN control bit
is enabled, but before zero insertion is considered.
1
Vcrc
This is the CRC recognition status bit for the receiver. Data is clocked into
the register and then this bit is monitored to see if comparison was
successful (bit will be one).
0
Vaddr
This is the address recognition status bit for the receiver. Data is clocked
into the Address Recognition Register and then this bit is monitored to see
if comparison was successful (bit will be one).
Table 96 - HDLC Test Status Register
(Page 0BH & 0CH, Address 1CH)
82
Zarlink Semiconductor Inc.
MT9075B
Bit
Name
7
---
6-4
RFD2 - 0
(000)
3
---
2-0
TFD2 - 0
(000)
Data Sheet
Functional Description
Unused.
These bits select the Rx FIFO full status level:
RFD2
RFD1
RFD0
Full Status Level
0
0
0
16
0
0
1
32
0
1
0
48
0
1
1
64
1
0
0
80
1
0
1
96
1
1
0
112
1
1
1
128
Unused.
These bits select the Tx HDLC FIFO full status level:
TFD2
TFD1
TFD0
Full Status Level
0
0
0
16
0
0
1
32
0
1
0
48
0
1
1
64
1
0
0
80
1
0
1
96
1
1
0
112
1
1
1
128
Table 97 - HDLC Control Register 3
(Pages 0BH & 0CH, Address 1DH)
83
Zarlink Semiconductor Inc.
MT9075B
Bit
Name
7
---
6-4
RFFS2 - 0
(000)
3
---
2-0
TFLS2 - 0
(000)
Data Sheet
Functional Description
Unused.
These bits select the RXFF (Rx FIFO Full) interrupt threshold level:
RFFS2
RFFS1
RFFS0
RX FIFO Full Interrupt
threshold Level.
0
0
0
64
0
0
1
72
0
1
0
80
0
1
1
88
1
0
0
96
1
0
1
104
1
1
0
112
1
1
1
120
Unused.
These bits select the TXFL (Tx FIFO Low) interrupt threshold level:
TFLS2
TFLS1
TFLS0
TX FIFO Low Interrupt
threshold Level.
0
0
0
8
0
0
1
16
0
1
0
24
0
1
1
32
1
0
0
40
1
0
1
48
1
1
0
56
1
1
1
64
Table 98 - HDLC Control Register 4
(Pages 0BH & 0CH, Address 1EH)
Transmit National Bit Buffer (Page 0DH)
Page 0DH, addresses 10H to 14H contain the five bytes of the transmit national bit buffer (TNBB0 - TNBB4
respectively). This feature is functional only when control bit NBTB (page 01H, address 10H) is one.
84
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Bit
Name
Functional Description
7-0
TNBBn.F1
TNBBn.F15
Transmit San+4 Bits Frames 1 to 15. This byte contains the bits transmitted in bit
position n+4 of channel zero of frames 1, 3, 5, 7, 9, 11, 13 and 15 when CRC-4
multiframe alignment is used, or of consecutive odd frames when CRC-4
multiframe alignment is not used. n = 0 to 4 inclusive and corresponds to a byte of
the receive national bit buffer.
Table 99 - Transmit National Bit Buffer Bytes Zero to Four (Page 0DH)
Receive National Bit Buffer (Page 0EH)
Page 0EH, addresses 10H to 14H contain the five bytes of the receive national bit buffer (RNBB0 - RNBB4
respectively).
Bit
Name
Functional Description
7-0
RNBBn.F1
RNBBn.F15
Receive San+4 Bits Frames 1 to 15. This byte contains the bits received in bit
position n+4 of channel zero of frames 1, 3, 5, 7, 9, 11, 13 and 15 when CRC-4
multiframe alignment is used, or of consecutive odd frames when CRC-4
multiframe alignment is not used. n = 0 to 4 inclusive and corresponds to a byte of
the receive national bit buffer.
Table 100 - Receive National Bit Buffer Bytes Zero to Four (Page 0EH)
Transmit Message Mode Buffer Zero and One (Pages 0FH and 10H)
Pages 0FH and 10H together contain 32 byte storage locations for data that may be transmit onto the equivalent
PCM 30 transmit timeslot. Transmission of these bytes is enabled by setting the TXMSG bits (bit 7) in the
equivalent Per Time Slot Control Register (page 07H and 08H). Table 97 shows the mapping between the Tx
Message Buffer addresses and the equivalent PCM 30 Channels.
Page 0FH (Tx Message
Buffer 0) Address:
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Equivalent
Timeslots
30
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Page 10H (Tx Message
Buffer 1) Address:
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Equivalent
Timeslots
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
PCM
PCM
30
Table 101 - Pages 0FH & 10H Address Mapping to CEPT Channels
85
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Page 0FH, addresses 10H to 1FH contain the 16 bytes of transmit message buffer zero
Bit
Name
Functional Description
7-0
TxB0.n.7 TxB0.n.0
Transmit Bits 7 to 0. This byte is transmit on a time slot when selected by the
TXMSG bit of the appropriate per time slot control word. n = 0 to 15 and represents
transmit timeslot numbers 0 to 15.
Table 102 - Transmit Message Mode Buffer Zero (Page 0FH)
Page 10H, addresses 10H to 1FH contain the 16 bytes of transmit message buffer one
Bit
Name
Functional Description
7-0
TxB1.n.7 TxB1.n.0
Transmit Bits 7 to 0. This byte is transmit on a time slot when selected by the
TXMSG bit of the appropriate per time slot control word. n = 0 to 15 and represents
transmit timeslot numbers 16 to 31.
Table 103 - Transmit Message Mode Buffer One (Page 10H)
Receive Message Mode Buffer Zero and One (Pages 11H and 12H)
Pages 11H and 12H - Receive Message Buffer 0 and 1 respectively, contain 32 bytes of memory. Each byte is
updated once per frame by the equivalent PCM 30 channel from the receive data stream.
Page 0FH (Rx Message Buffer 0) Address:
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Equivalent
Timeslots
30
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Page 10H (Rx Message
Buffer 1) Address:
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Equivalent
Timeslots
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
PCM
PCM
30
Table 104 - Pages 11H & 12H Address Mapping to CEPT Channels
Page 11H, addresses 10H to 1FH contain the 16 bytes of receive message buffer zero
Bit
Name
Functional Description
7-0
RxB0.n.7 RxB0.n.0
Receive Bits 7 to 0. Each byte is sourced from a time slot coming from the line data.
n=0 to 15 represents receive timeslots 0 to 15.
Table 105 - Receive Message Buffer Zero (Page 11H)
86
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
Page 12H, addresses 10H to 1FH contain the 16 bytes of receive message buffer one
Bit
Name
Functional Description
7-0
RxB1.n.7 RxB1.n.0
Receive Bits 7 to 0. Each byte is sourced from a time slot coming from the line data.
n=0 to 15 represents receive timeslots 16 to 31.
Table 106 - Receive Message Buffer One (Page 12H)
Absolute Maximum Ratings* - Voltages are with respect to ground (VSS) unless otherwise stated.
Parameter
Symbol
Min.
Max.
Units
VDD
-0.3
7
V
-0.3
VDD + 0.3
V
30
mA
VDD + 0.3
V
30
mA
125
°C
1
Supply Voltage
2
Voltage at Digital Inputs
VI
3
Current at Digital Inputs
II
4
Voltage at Digital Outputs
VO
5
Current at Digital Outputs
IO
-0.3
-55
6 Storage Temperature
TST
* Exceeding these values may cause permanent damage. Functional operation under these conditions is not implied.
Recommended Operating Conditions
- Voltages are with respect to ground (VSS) unless otherwise stated.
Characteristics
1
Operating Temperature
Sym
Min
TOP
-40
Typ‡
Max
Units
85
°C
Test Conditions
4.75
5
5.25
V
2 Supply Voltage
VDD
‡ Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing.
DC Electrical Characteristics†
- Voltages are with respect to ground (VSS) unless otherwise stated.
Characteristics
Sym.
Min.
Typ.‡
Max.
Units
150
mA
1
Supply Current
IDD
2
Input High Voltage (Digital Inputs)
VIH
2.0
VDD
V
3
Input Low Voltage (Digital Inputs)
VIL
0
0.8
V
4
Input Leakage (Digital Inputs)*
IIL
10
A
5
Output High Voltage (Digital Outputs)
VOH
2.4
VDD
V
6
Output High Current (Digital Outputs)
IOH
7
7
Output Low Voltage (Digital Outputs)
VOL
VSS
8
Output Low Current (Digital Outputs)
IOL
7
mA
0.4
V
mA
Test Conditions
Outputs unloaded.
Transmitting an all 1’s
signal.
VI = 0 to VDD
IOH=7 mA @ VOH=2.4 V
Source VOH=2.4 V
IOL=2 mA @ VOL= 0.4 V
Sink VOL=0.4 V
10
A
VO = 0
9
High Impedance Leakage (Digital I/O)
IOZ
† Characteristics are for clocked operation over the ranges of recommended operating temperature and supply voltage.
‡ Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing.
‡ * Limits for input leakage on pin names: tdi, tck, tms and trstb are max 100uA.
87
Zarlink Semiconductor Inc.
to VDD
MT9075B
Data Sheet
AC Electrical Characteristics - Timing Parameter Measurement Voltage Levels
Characteristics
Sym.
Level
Units
Conditions/Notes
1
TTL Threshold Voltage
VTT
1.5
V
See Note 1
2
CMOS Threshold Voltage
VCT
0.5VDD
V
See Note 1
3
Rise/Fall Threshold Voltage High
VHM
2.0
0.7VDD
V
V
TTL
CMOS
4
Rise/Fall Threshold Voltage Low
VLM
0.8
0.3VDD
V
V
TTL
CMOS
Note 1: Timing for output signals is based on the worst case result of the combination of TTL and CMOS thresholds.
AC Electrical Characteristics† - Motorola Microprocessor Timing
Characteristics
Sym.
Min.
Typ.‡
Max.
Units
Test Conditions
1
DS low
tDSL
70
ns
2
DS High
tDSH
50
ns
3
CS Setup
tCSS
0
ns
4
R/W Setup
tRWS
10
ns
5
Address Setup
tADS
10
ns
6
CS Hold
tCSH
0
ns
7
R/W Hold
tRWH
15
ns
8
Address Hold
tADH
15
ns
9
Data Delay Read
tDDR
80
ns
CL=50pF, RL=1k
10
Data Hold Read
tDHR
80
ns
CL=50pF, RL=1k
11
Data Active to High Z Delay
tDAZ
80
ns
12
Data Setup Write
tDSW
10
ns
13
Data Hold Write
tDHW
10
ns
*
tCYC
120
ns
Cycle Time
† Characteristics are for clocked operation over the ranges of recommended operating temperature and supply voltage
‡ Typical figures are at 25°Cand are for design aid only: not guaranteed and not subject to production testing.
* This cycle time is for all accesses other than HDLC FIFOs. For HDLC FIFO accesses, a minimum 100ns is required between successive
Read/Write operations.
14
88
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
tCYC
tDSL
DS
VTT
tDSH
tCSS
tCSH
CS
VTT
tRWH
tRWS
VTT
R/W
tADS
tADH
VTT
A0-A4
tDDR
tDAZ
VALID DATA
D0-D7
READ
VTT,VCT
tDHW
tDSW
D0-D7
WRITE
tDHR
VALID DATA
VTT
Note: DS and CS may be connected together.
Figure 11 - Motorola Microprocessor Timing
AC Electrical Characteristics† - Intel Microprocessor Timing
Characteristics
Sym.
Min.
Typ.‡
Max.
Units
1
RD low
tRDL
60
ns
2
RD High
tRDH
50
ns
3
CS Setup
tCSS
0
ns
4
CS Hold
tCSH
0
ns
5
Address Setup
tADS
10
ns
6
Address Hold
tADH
15
ns
7
Data Delay Read
tDDR
80
ns
8
Data Active to High Z Delay
tDAZ
80
ns
9
Data Setup Write
tDSW
10
ns
10
Data Hold Write
tDHW
10
ns
*
Test Conditions
CL=50pF, RL=1k.
tCYC
110
Cycle Time
† Characteristics are for clocked operation over the ranges of recommended operating temperature and supply voltage
‡Typical figures are at 25°C and are for design aid only: not guaranteed and not subject to production testing.
* This cycle time is for all accesses other than HDLC FIFOs. For HDLC FIFO accesses, a minimum 100ns is required between successive
Read/Write operations.
11
89
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
tCYC
tRDL
RD
VTT
tRDH
tCSS
tCSH
CS
VTT
tCSH
WR
VTT
tADH
tADS
tADH
A0-A4
VTT
tDDR
tDAZ
VALID DATA
D0-D7
READ
tDSW
D0-D7
WRITE
VTT,VCT
tDHW
VALID DATA
VTT
Figure 12 - Intel Microprocessor Timing
AC Electrical Characteristics - Transmit Data Link Timing
Characteristic
Sym.
Min.
Typ.
Max.
Units
35
ns
1
Data Link Clock Output Delay
tTDC
2
Data Link Setup
tDLS
10
ns
3
Data Link Hold
tDLH
10
ns
90
Zarlink Semiconductor Inc.
Test Conditions
50pF
MT9075B
Data Sheet
F0b
TIME SLOT 0
Bits 4,3,2,1,0
Example A - 20 kb/s
TxDLCLK
TxDL
Example B - 12 kb/s
TxDLCLK
TxDL
Figure 13 - Transmit Data Link Functional Timing
C4b
VTT
tTDC
VTT,VCT
TxDLCLK
tDLS
tDLH
VTT
TxDL
Figure 14 - Transmit Data Link Timing Diagram
91
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
AC Electrical Characteristics - Receive Data Link Timing
Characteristic
Sym.
1
Data Link Clock Output Delay
tRDC
2
Data Link Output Delay
tRDD
Min.
Typ.
Max.
Units
150
ns
50pF
ns
50pF
45
Test Conditions
RxFP
TIME SLOT 0
Bits 4,3,2,1,0
Example A - 20 kb/s
RxDLCLK
RxDL
Example B - 12 kb/s
RxDLCLK
RxDL
Figure 15 - Receive Data Link Functional Timing
VTT
E2o
tRDC
tRDC
VTT,VCT
RxDLCLK
tRDD
RxDL
VTT,VCT
Figure 16 - Receive Data Link Timing Diagram
92
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
AC Electrical Characteristics - Transmit 64 k Common Channel Timing
Characteristic
Sym.
Min.
Typ.
Max.
Units
1
Transmit Common Channel Setup
tTCS
15
ns
2
Transmit Common Channel Hold
tTCH
15
ns
Test Conditions
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
11
12
STBUS
Channel Times
0
1
2
3
4
5
6
7
8
9
10
F0b
Internal
Clock
CSTi
Figure 17 - Transmit 64 k Common Channel Functional Timing
C4b
VTT
Internal
Clock
tTCS
tTCH
VTT
CSTi
Figure 18 - Transmit 64 k Common Channel Timing Diagram
93
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
AC Electrical Characteristics - Receive 64 k Common Channel Timing
1
Characteristic
Sym.
Receive Common Channel Output
Delay
tRCD
Min.
Typ.
Max.
Units
60
ns
Test Conditions
50 pF
Receive Frame Boundary
Rx64KCK
CSTo
Figure 19 - Receive 64 k Common Channel Functional Timing
VTT
Rx64KCK
tRCD
VTT,VCT
CSTo
Figure 20 - Receive 64 k Common Channel Timing Diagram
94
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
AC Electrical Characteristics - ST-BUS/GCI Timing
Characteristic
Sym.
Min.
Typ.
Max.
Units
Test Conditions
1
C4b Clock Width High or Low
t4WI
80
164
ns
C4b as input
2
C4b Clock Width High or Low
t4WO
110
135
ns
C4b as output
3
Frame Pulse Setup
tFPS
10
ns
F0b as input
4
Frame Pulse Hold
tFPH
10
ns
F0b as input
5
Frame Pulse Delay
tFPD
12
ns
F0b as output
6
Serial Input Setup
tSIS
15
ns
7
Serial Input Hold
tSIH
15
ns
8
Serial Output Delay
tSOD
ST-BUS
Bit Cells
Channel 31
Bit 0
54
Channel 0
Bit 7
Channel 0
Bit 6
ns
50pF
Channel 0
Bit 5
F0b
C4b
Figure 21 - ST-BUS Functional Timing Diagram
ST-BUS Bit
Stream
Bit Cell
Bit Cell
Bit Cell
tFPH
F0b
VTT
tFPS
t4WI
t4WI
C4b
(Input)
VTT
tSIH
All Input
Streams
VTT
tSIS
tSOD
All Output
Streams
VTT,VCT
Figure 22 - ST-BUS Timing Diagram
95
Zarlink Semiconductor Inc.
MT9075B
ST-BUS Bit
Stream
Bit Cell
Data Sheet
Bit Cell
Bit Cell
F0b
(Output)
VTT
tFPD
t4WO
tFPD
C4b
(Output)
VTT
tSIH
t4WO
All Input
Streams
VTT
tSIS
tSOD
All Output
Streams
VTT,VCT
Figure 23 - ST-BUS Timing Diagram (Output Clocks)
ST-BUS
Bit Cells
Channel 31
Bit 0
Channel 0
Bit 7
Channel 0
Bit 6
F0b
C4b
Figure 24 - GCI Functional Timing Diagram
96
Zarlink Semiconductor Inc.
Channel 0
Bit 5
MT9075B
ST-BUS Bit
Stream
Bit Cell
Data Sheet
Bit Cell
F0b
(Input)
Bit Cell
VTT
tFPH
tFPS
t4WI
C4b
(Input)
VTT
tSIH
t4WI
All Input
Streams
VTT
tSIS
tSOD
All Output
Streams
VTT,VCT
Figure 25 - GCI Timing Diagram (Input Clocks)
ST-BUS Bit
Stream
Bit Cell
Bit Cell
Bit Cell
tFPD
VTT
F0b
(Output)
tFPD
t4WO
C4b
(Output)
VTT
tSIH
t4WO
All Input
Streams
VTT
tSIS
tSOD
All Output
Streams
VTT,VCT
Figure 26 - GCI Timing Diagram (Output Clocks)
97
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
AC Electrical Characteristics - Multiframe Timing
Characteristic
Sym.
Min.
1
Receive Multiframe Output Delay
2
Transmit Multiframe Setup
tMS
50
3
Transmit Multiframe Hold
tMH
50
Typ.
Max.
Units
50
ns
tMOD
Bit 7
Bit 6
Bit 5
Bit 4
50 pF
ns
*
ns
Frame 15
DSTo
BIt Cells
Test Conditions
* 256 C2 periods 100nsec
Frame 0
Bit 0
Bit 7
Bit 6
Bit 5
Bit 4
Bit 0
Bit 7
Bit 0
Bit 7
F0b
C4b
(4.096 MHz)
RxMF
Figure 27 - Receive Multiframe Functional Timing
Frame N
DSTi
Bit Cells
Bit 7
Bit 6
Bit 5
Bit 4
Frame 0
Bit 0
Bit 7
Bit 6
Bit 5
Bit 4
F0b
C4b
(4.096 MHz)
TxMF
Figure 28 - Transmit Multiframe Functional Timing
98
Zarlink Semiconductor Inc.
MT9075B
Data Sheet
VTT
F0b
tMOD
VTT
C4b
tMOD
RxMF(1)
VTT,VCT
tMH2
tMH
tMS
TxMF(1)
Note
(1)
VTT
: These two signals do not have a defined phase relationship
Figure 29 - Multiframe Timing Diagram
2.0 ms
FRAME
15
• • • • • • • •
FRAME
0
FRAME
14
TIME SLOT
1
TIME SLOT
0
FRAME
15
TIME SLOT
30
• • • •
FRAME
0
TIME SLOT
31
125 s
Most
Significant
Bit (First)
BIT
1
BIT
2
BIT
3
BIT
4
BIT
5
BIT
6
BIT
7
BIT
8
Least
Significant
Bit (Last)
(8/2.048) s
Figure 30 - PCM 30 Format
125s
CHANNEL
31
CHANNEL
0
Most
Significant
Bit (First)
CHANNEL
30
• • •
BIT
7
BIT
6
BIT
5
BIT
4
BIT
3
BIT
2
(8/2.048)s
Figure 31 - ST-BUS Stream Format
99
Zarlink Semiconductor Inc.
CHANNEL
31
BIT
1
BIT
0
CHANNEL
0
Least
Significant
Bit (Last)
For more information about all Zarlink products
visit our Web Site at
www.zarlink.com
Information relating to products and services furnished herein by Zarlink Semiconductor Inc. or its subsidiaries (collectively “Zarlink”) is believed to be reliable.
However, Zarlink assumes no liability for errors that may appear in this publication, or for liability otherwise arising from the application or use of any such
information, product or service or for any infringement of patents or other intellectual property rights owned by third parties which may result from such application or
use. Neither the supply of such information or purchase of product or service conveys any license, either express or implied, under patents or other intellectual
property rights owned by Zarlink or licensed from third parties by Zarlink, whatsoever. Purchasers of products are also hereby notified that the use of product in
certain ways or in combination with Zarlink, or non-Zarlink furnished goods or services may infringe patents or other intellectual property rights owned by Zarlink.
This publication is issued to provide information only and (unless agreed by Zarlink in writing) may not be used, applied or reproduced for any purpose nor form part
of any order or contract nor to be regarded as a representation relating to the products or services concerned. The products, their specifications, services and other
information appearing in this publication are subject to change by Zarlink without notice. No warranty or guarantee express or implied is made regarding the
capability, performance or suitability of any product or service. Information concerning possible methods of use is provided as a guide only and does not constitute
any guarantee that such methods of use will be satisfactory in a specific piece of equipment. It is the user’s responsibility to fully determine the performance and
suitability of any equipment using such information and to ensure that any publication or data used is up to date and has not been superseded. Manufacturing does
not necessarily include testing of all functions or parameters. These products are not suitable for use in any medical products whose failure to perform may result in
significant injury or death to the user. All products and materials are sold and services provided subject to Zarlink’s conditions of sale which are available on request.
Purchase of Zarlink’s I2C components conveys a license under the Philips I2C Patent rights to use these components in an I2C System, provided that the system
conforms to the I2C Standard Specification as defined by Philips.
Zarlink, ZL, the Zarlink Semiconductor logo and the Legerity logo and combinations thereof, VoiceEdge, VoicePort, SLAC, ISLIC, ISLAC and VoicePath are
trademarks of Zarlink Semiconductor Inc.
TECHNICAL DOCUMENTATION - NOT FOR RESALE