Leaded resistors, cement, fusible thermal & vertical lead

Through-hole resistors
Fusible Thermal &
Vertical Lead Type
Cement Resistors
Normal Style [ FTR Series ]
FEATURES
Rated Current
2A, 3A, 5A, 10A
Resistance Tolerance
±5%, ±10%
T.C.R
±250ppm/°C
INTRODUCTION
The material used and the construction
techniques ensure excellent flame resistance,
arc resistance and moisture resistance as well as
self-extinguishing capabilities. They will withstand
the most rigorous loading test, also provide
outstanding feature against surges, suitable for
the prevention of inrush current for switching
regulators.
DIMENSIONS
Unit: mm
W
S
H
4.5+2/-1
08±0.1
P
ød2
STYLE
DIMENSION
Normal
H
W
S
P
FTR100
25±1.5
13±1.0
9.0±1.0
5.0±1.0
FTR200
38±1.5
13±1.0
9.0±1.0
5.0±1.0
FTR300
35±1.5
16±1.0
12±1.0
7.5±1.0
ød2
0.6±0.1
75
Note:
ELECTRICAL CHARACTERISTICS
STYLE
FTR100 / 200 / 300
STANDARD
FUSING
STANDARD
RESISTANCE
POWER RATING AT 70°C (W)
CURRENT (A) TEMPERATURE (°C) VOLTAGE (V) RANGE
FTR100
FTR200
FTR300
10A
1.2
1.4
2.0
129±4
1.6
2.0
2.5
152±4
1.6
2.0
2.5
188+3/-1
2.0
2.4
3.5
226+1/-3
2.0
2.4
3.5
129±3
1.6
2.2
-
187+1/-3
2.1
2.4
-
3A
145±4
1.6
2.2
-
2A
95+3/0
0.8
1.2
-
110±4
1.2
1.4
-
126±4
1.4
1.6
-
130±4
1.6
2.1
-
135±4
1.8
2.2
-
145±4
2.1
2.4
-
5A
109+1/-3
250
1Ω - 10KΩ
Note: Special value is available on request
ENVIRONMENTAL CHARACTERISTICS
PERFORMANCE TEST
TEST METHOD
APPRAISE
Short Time Overload
IEC 60115-1 4.13
2.5 times RCWV for 5 Sec.
±2.0%+0.05Ω
Temperature Coefficient
IEC 60115-1 4.8
-25°C to +125°C
By type
Robustness of Terminations
IEC 60115-1 4.16
Direct load for 10 Sec. In the direction of the terminal leads
≥25N
Damp Heat Steady State
IEC 60115-1 4.24
40±2°C, 90-95% RH for 56 days, loaded with 0.1 times RCWV
±5.0%+0.1Ω
Note: RCWV(Rated Continuous Working Voltage) = Power Rating x Resistance Value or Max. working voltage listed above, whichever less.
Revision: 201304
88
Explanations Of Ordering Code
MFR
-12
F
Code 7
Tolerance
T
F
Code 8
Packing Style
Code 9
Temperature Coefficient of Resistance
Code 1 - 3
Series Name
Code 4 - 6
Power Rating
See Index
-05= ød0.5mm
P= ±0.02 %
T = Tape/Box
-06 = ød0.6mm
A= ±0.05 %
R = Tape/Reel
- = Base on Spec.
-07 = ød0.7mm
B= ±0.1 %
B = Bulk
52-
100R
Code 10 - 12
Forming Type
Code 13 - 17
Resistance Value
26- = 26mm
0R1=0.1
52- = 52.4mm
100R=100
A = ±5 ppm/°C
73- = 73mm
10K=10,000
81- = 81mm
10M=10,000,000
-08 = ød0.8mm
C= ±0.25%
B = ±10 ppm/°C
-10 = ød1.0mm
D= ±0.5 %
C = ±15 ppm/°C
91- = 91mm
-14 = ød1.4mm
F = ±1 %
S = ± 20ppm/°C
F = F Type
-12 = 1/6W
G= ±2 %
D = ±25 ppm/°C
FK = FK Type
-25 = 1/4W
J = ±5 %
E = ±50 ppm/°C
FKK= FKK Type
25S = 1/4WS
K= ±10 %
F = ±100 ppm/°C
FFK= F-form Kink
-50 = 1/2W
- = Base on Spec.
G = ±200 ppm/°C
M = M-Type Forming
50S = 1/2WS
H = ±250 ppm/°C
MB = M-form W/flat
100 = 1W
I = ±300 ppm/°C
MT = MT Type Forming
1WS = 1WS
J = ±350 ppm/°C
MR = MR Type
200 = 2W
AV = AVIsert
2WS = 2WS
PN = PANAsert
204 = 0.4W
207 = 0.6W
300 = 3W
3WS = 3WS
3WM= 3WM
400 = 4W
500 = 5W
5WS = 5WS
5SS = 5WSS
700 = 7W
7WS = 7WS
10A = 10W
20A = 20W
30A = 30W
40A = 40W
50A = 50W
10S = 10WS
15A = 15W
25A= 25W
10B = 100W
25B = 250W
EXCEPTION:
• Cement series:
• JPW series:
<Code 8>: Special packing style code
B: B
ulk with wirewound or metal oxide sub-assembly for resistance value
W: Bulk with ceramic based wirewound sub-assembly for resistance value
M: Bulk with metal oxide sub-assembly for resistance value
F: Bulk with Fiberglass based wirewound sub-assembly for resistance value
<Code 10-12>: Without forming code
Example:
SQP500JB-10R
<Code 13-17>: without resistance value code
Example:
JPW-06-T-52-