FEATURES
Power Rating
1/4W, 1/2W, 1W, 2W, 3W
Resistance Tolerance
5%
T.C.R.
±300ppm/°C
Flameproof Multi-layer Coating Meets
UL-94V-0
Flameproof Feature Meets Overload Test
UL-1412
INTRODUCTION
The APR Series Pulse-Loading Resistors have
excellent capability in withstanding pulse; tinned
connecting leads of electrolytic copper are
welded to the end-caps. The resistors are
coated with layers of gray color lacquer. The
5th color band is yellow to represent APR
series.
DERATING CURVE
For resistors operated in ambient temperatures above 70°C, power rating must be derated
in accordance with the curve below.
Rated Load (%)
70
200°C
100
80
60
40
20
20
40
60
80
100 120 140 160 180 200
Ambient Temperature (°C)
DIMENSIONS
Unit: mm
STYLE
ød
H
L
5th color code: yellow
øD
DIMENSION
Normal
Minuature
L
øD
H
ød
APR-25
APR50S
6.3±0.5
2.4±0.2
28±2.0
0.55±0.05
APR-50
APR1WS
9.0±0.5
3.3±0.3
26±2.0
0.55±0.05
APR100
APR2WS
11.5±1.0
4.5±0.5
35±2.0
0.80±0.05
APR200
APR3WS
15.5±1.0
5.0±0.5
33±2.0
0.80±0.05
43
Note:
ELECTRICAL CHARACTERISTICS
STYLE
APR-25
APR50S
Power Rating at 70°C
1/4W
1/2W
APR-50
APR1WS
APR100
1W
Maximum Working Voltage
PxR
Voltage Proof on Insulation
400V
Resistance Range
1Ω - 100KΩ & 0Ω for E24 series value
Operating Temp. Range
-55°C to +200°C
Temperature Coefficient
±300ppm/°C
APR2WS
APR200
2W
APR3WS
3W
500V
Note: Special value is available on request
ENVIRONMENTAL CHARACTERISTICS
PERFORMANCE TEST
TEST METHOD
APPRAISE
Short Time Overload
IEC 60115-1 4.13
2.5 times RCWV for 5 Sec.
±0.75%+0.05Ω
Voltage Proof on Insulation
IEC 60115-1 4.7
in V-block for 60 Sec., test voltage by type
By type
Temperature Coefficient
IEC 60115-1 4.8
-55°C to +155°C
By type
Insulation Resistance
IEC 60115-1 4.6
in V-block for 60 Sec.
>10,000M
Solderability
IEC 60115-1 4.17
235±5°C for 3±0.5 Sec.
95% Min. coverage
Solvent Resistance of Marking
IEC 60115-1 4.30
IPA for 5±0.5 Min. with ultrasonic
No deterioration of
coatings and markings
Robustness of Terminations
IEC 60115-1 4.16
Direct load for 10 Sec. in the direction of the terminal leads
≥2.5kg (24.5N)
Periodic-pulse Overload
IEC 60115-1 4.39
4 times RCWV 10,000 cycles (1 Sec. on, 25 Sec. off)
±1.0%+0.05Ω
Damp Heat Steady State
IEC 60115-1 4.24
40±2°C, 90-95% RH for 56 days, loaded with 0.1 times RCWV
±3.0%+0.05Ω
Endurance at 70°C
IEC 60115-1 4.25
70±2°C at RCWV for 1,000 Hr. (1.5 Hr. on, 0.5 Hr. off)
±3.0%+0.05Ω
Temperature Cycling
IEC 60115-1 4.19
-55°C  Room Temp.  +155°C  Room Temp. (5 cycles)
±1.0%+0.05Ω
Resistance to Soldering Heat
IEC 60115-1 4.18
260±3°C for 10±1 Sec., immersed to a point 3±0.5mm from the body
±1.0%+0.05Ω
Accidental Overload Test
IEC 60115-1 4.26
4 times RCWV for 1 Min.
No evidence of flaming
or arcing
Note: RCWV(Rated Continuous Working Voltage) = Power Rating x Resistance Value or Max. working voltage listed above, whichever less.