UMK 250 - Non resettable fuses

UMK 250
Non resettable fuses
www.schurter.com/PG01_2
Surface Mount Fuse with Clip, 11.3 x 4.2 mm, Quick-Acting F, UMK 250 = UMF 250 (Au) + UMC 250
IEC 60127-4 · 250 VAC · 125 VDC · Quick-Acting F
Description
-VDE/UL Approvals, UMF 250, UMF 250 (Au), UMC 250 , see variants
-High breaking capacity of up to 200 A @ 250 VAC
-UL approval for 0.05 A - 4 A @ 250 VAC and 125 VDC
Standards
Applications
-Primary protection on SMD PCBs
-Industrial electronic
References
Packaging Details
Fuse Kit Fuse Kit UMF 250 / UMK 250 -IEC 60127-4/2, IEC 60127-6
-UL 248-14 / 4248-1
-CSA C22.2 no. 248.14 / no. 4248.1
Weblinks
-VDE Certificate Number: 40027880 / 40023291
-UL File Number: E41599
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, e-Shop,
SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for
product
Technical Data
Approvals
Rated Voltage
Rated current
Breaking Capacity
Characteristic
Mounting
Admissible Ambient Air Temp.
Climatic Category
Material: Housing
Material: Terminals
Storage Conditions
Product Marking
250 VAC, 125 VDC
0.5 - 4 A
100-200 A
Quick-Acting F
PCB,SMT
-40 °C to 85 °C
40/085/21 acc. to IEC 60068-1
Ceramic
Gold-Plated Copper Alloy
0 °C to 40 °C, max. 70% r.h.
, Rated current, Rated voltage, Characteristic, Breaking Capacity
Soldering Methods
Solderability
Resistance to Soldering Heat
Life Test
Moisture Resistance Test
Terminal Strength
Mechanical Shock
Resistance to Solvents
Flammability
Dimension
Reflow
245 °C / 3 sec acc. to IEC 60068-2-58
260 °C / 10 sec acc. to IEC 60068-2-58
(acc. to EIA/IS-722, Test 4.4.1)
1000h @ 0.60 x In @ 70°C
(acc. to EIA/IS-722, Test 4.4.3)
10% rated current. Temperatur change
between 25°C und 65°C at 100% relative humidity. Duration: 24h each cycle,
total 10 cycles
(acc. to EIA/IS-722, Test 4.5.5)
(Deflection of board 1 mm for 1 minute)
MIL-STD-202, Method 213B
(Shock 50g, half sine wave, 11 ms)
Cleaning with common solvents
min. UL 94V-1
(acc. to EIA/IS-722, Test 4.12)
11.3 mm
4
+0.2
0
4.75
10.1
10.7
3
2
5.5
3
4.2
3.6
11.3
6.7
Soldering pads
Fuses
1
UMK 250
Non resettable fuses
www.schurter.com/PG01_2
Pre-Arcing Time
Rated Current In
1.0 x In min.
1.25 x In min.
2.0 x In max.
-
60 min
120 s
0.5 A - 4.0 A
10.0 x In min. 10.0 x In max.
1 ms
10 ms
Time-Current-Curves
10000
500 mA
630 mA
800 mA
1A
1.25 A
1.6 A
2A
2.5 A
3.15 A
4A
1000
100
Time in Seconds
10
1
0.1
0.01
0.001
0.0001
0.1
1
10
100
Current in Amperes
All Variants
Rated Current [A]
Rated Voltage [VAC]
Rated Voltage [VDC]
0.5
250
125
0.63
250
0.8
250
1
Breaking
Capacity
Voltage Drop
1.0 In max.
[mV]
Voltage Drop
1.0 In typ.
[mV]
Power Dissipation 1.25 In
max [mW]
Melting I²t
10.0 Intyp.
[A²s]
Order Number
1)
430
600
500
0.27
l
l
125
1)
350
500
500
0.9
l
125
1)
300
400
500
0.21
l
250
125
1)
250
300
500
0.4
1.25
250
125
2)
220
300
1000
1.6
250
125
2)
190
300
3404.2463.xx
█
l
3404.2464.xx
█
l
3404.2465.xx
█
l
l
3404.2466.xx
█
1
l
l
3404.2467.xx
█
1000
2.1
l
l
3404.2468.xx
█
2
250
125
2)
200
300
1000
3.26
l
l
3404.2469.xx
█
2.5
250
125
2)
160
300
1200
4.8
l
l
3404.2470.xx
█
3.15
250
125
2)
100
300
1500
5.17
l
l
3404.2471.xx
█
4
250
125
2)
100
300
2000
9.4
l
l
3404.2472.xx
█
█ Most Popular.
Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
1) IEC: 100 A @ 250 VAC, p.f. ≥ 0.95 / 100 A @ 125 VDC
1) UL: 200 A @ 250 VAC / 100 A @ 125 VDC / 35 A @ 250 VDC / 200 A @ 63 VAC/DC
2) IEC / UL: 200 A @ 250 VAC / 100 A @ 125 VDC / 35 A @ 250 VDC / 200 A @ 63 VAC/DC
Approval Overview
UMF 250 -> Fuse with tin-plated caps, Approval Status: VDE, UL LISTED, cURus, Free of CCC, PSE JET, KTL
UMF 250 (Au) -> Fuse with gold-plated caps, Approval Status: VDE Mark and cURus
UMC 250 -> Clip, Approval Status: VDE UG Mark and cURus
UMK 250 = UMF 250 (Au) + UMC 250
There is no approval existing for the combination fuse and clip UMK 250, but the fuse and the clip are fully approved independently at VDE/UL. See
details above.
In the reflow soldering process, the fuse must have gold-plated caps, otherwise fuse and clip would be soldered together. For fuse replacement in the
field, a standard UMF 250 fuse with tin-plated caps can be used.
2
Fuses
UMK 250
Non resettable fuses
www.schurter.com/PG01_2
Rated Current [A]
Rated Voltage [VAC]
Rated Voltage [VDC]
Breaking
Capacity
Voltage Drop
1.0 In max.
[mV]
Voltage Drop
1.0 In typ.
[mV]
Power Dissipation 1.25 In
max [mW]
Melting I²t
10.0 Intyp.
[A²s]
Order Number
It is not allowed to replace higher rated current than 4 A in the clip.
.xx = .11Plastic Bag (100 pcs.)
.xx = .22Blister Tape 33 cm Reel (1000 pcs.)
30.06.2015
Packaging Unit The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
Fuses
3