PFRX - Resettable Fuses

PFRX
Resettable Fuses
www.schurter.com/pg01_1
On phase-out, not recommended for new designs
OU
T
RX
1
018 10
0T
60.0 VDC · 1.1 - 3.75 A
Description
Applications
-PFRY is recommended as substitute
-Security and fire alarm systems
-Loud speakers
-Power transformers
Standards
-UL 1434
-CSA C22.2 no. 0, TIL no. CA-3A
References
Packaging Details
Approvals
Weblinks
-UL File Number: E172175
E-
pdf-datasheet, html-datasheet, General Product Information,
Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, e-Shop,
SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for
product
Technical Data
Dimensions
60.0 VDC
40 A
1.1 - 3.75 A
PCB,THT
-40 °C to 85 °C
Tin-Plated Copper
0.35 g
0 °C to 40 °C, max. 70% r.h.
, Type, I hold
Soldering Methods
Solderability
Resistance to Soldering Heat
Passing Aging
Humidity Aging
Thermal Shock
AS
V max
Imax
I hold
Mounting
Allowable Operation Temp.
Material: Terminals
Weight
Storage Conditions
Product Marking
Resistance to Solvents
Flammability
E
1.3
C
D
PH
B
A
Vibration
Wave
235 °C / 2 sec
260 °C / 10 sec
+85 °C, 1000 Hours -> +/- 5% Typical
Resistance Change
+85 °C, 85% r.h., 1000 Hours -> +/5% Typical Resistance Change
MIL-STD-202, Method 107 (+125 °C to
-55 °C, 10 Cycles) -> +/- 15% Typical
Resistance Change
MIL-STD-883C, Method 2007.1, Test
Condition A
MIL-STD-202, Methode 215
UL 94V-0
C
PFRA.010 - PFRA.185
Drilling diagram
Fuses
1
PFRX
Resettable Fuses
www.schurter.com/pg01_1
Dimensions
Insert
depth
C min
[mm]
C max
[mm]
D min
[mm]
E max
[mm]
Ø Lead [mm]
Order Number
13
18
4.4
5.1
7.6
3.1
0.81
PFRX.110
14.5
19.6
4.4
5.1
7.6
3.1
0.81
PFRX.135
16.3
21.3
4.4
5.1
7.6
3.1
0.81
PFRX.160
17.8
22.9
4.4
5.1
7.6
3.1
0.81
PFRX.185
21.3
26.4
9.5
10.2
7.6
3.1
0.81
PFRX.250
30
9.5
10.2
7.6
3.1
0.81
PFRX.300
33.5
9.5
10.2
7.6
3.1
0.81
PFRX.375
Thermal Derating Chart Ihold [A]
-40 °C
-20 °C
0 °C
23 °C
40 °C
50 °C
1.71
1.5
1.31
1.1
0.89
0.79
2.09
1.84
1.61
1.35
1.09
0.97
2.48
2.18
1.9
1.6
1.3
1.15
2.87
2.52
2.2
1.85
1.5
1.33
OU
24.9
28.4
3.88
3.4
2.98
2.5
2.03
1.8
4.65
4.08
3.57
3
2.43
2.16
5.81
5.1
4.46
3.75
3.04
2.7
R initial min
[Ω]
R initial max
[Ω]
Electrical Characteristics at 23 °C
I max [A]
I hold [A]
I trip [A]
60.0
40
1.1
2.2
60.0
40
1.35
2.7
60.0
40
1.6
3.2
60.0
40
1.85
3.7
60.0
40
2.5
5
60.0
40
3
6
60.0
40
3.75
7.5
85 °C
Order Number
0.69
0.59
0.44
PFRX.110
0.73
0.54
PFRX.135
1.01
0.86
0.64
PFRX.160
1.17
1
0.74
PFRX.185
1.58
1.35
1
PFRX.250
1.89
1.62
1.2
PFRX.300
2.36
2.03
1.5
PFRX.375
R 1hour max
[Ω]
Max Time to
trip [A]
Max Time to
Trip [s]
Tripped
Power Dissipation [W]
Order Number
0.15
0.25
0.38
5.5
8.2
1.50
PFRX.110
0.12
0.19
0.3
6.75
9.6
1.70
PFRX.135
0.09
0.14
0.22
8
11.4
1.90
PFRX.160
0.08
0.12
0.19
9.25
12.6
2.10
PFRX.185
0.05
0.08
0.13
12.5
15.6
2.50
PFRX.250
0.04
0.06
0.1
15
19.8
2.80
PFRX.300
0.03
0.05
0.08
18.75
24
3.20
PFRX.375
PFRX.xxxBulk (500 pcs.)
PFRX.110.2 - PFRX.160.2
Taped 34 cm Reel (1500 pcs.)
PFRX.185.2
Taped 34 cm Reel (1000 pcs.)
PH
2
70 °C
0.85
AS
Packaging Unit 60 °C
E-
V max [VDC]
T
A max
[mm]
Fuses
PFRX
Resettable Fuses
www.schurter.com/pg01_1
Time-Current-Curves
T
1000
PFRX.250
100
PFRX.300
PFRX.375
PFRX.110
PFRX.135
1
PFRX.160
PFRX.185
0.1
0.01
0.001
1
10
100
The specifications, descriptions and illustrations indicated in this document are based
on
Fuses
current information. All content is subject to modifications and amendments.
10.06.2013
PH
AS
E-
0.1
Fault Current in Amperes
OU
Time to Trip in Seconds
10
3