1064 Power entry modules without line filter www.schurter.com/PG05 IEC Appliance Inlet C14 or C18 with Fuseholder 1- or 2-pole Snap-In Version C14 C18 70° C 70° C Description Characteristics -Panel Mount: Snap-in version, from front side Appliance Inlet, Protection class I, Fuseholder for fuse-links 5 x 20 mm -Solder terminals or quick connect terminals -The fuse drawer "Fingergrip" can be removed by hand Weblinks pdf-datasheet, html-datasheet, General Product Information, Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Mating Connectors, e-Shop, SCHURTER-Stock-Check, Distributor-StockCheck, CAD-Drawings, Accessories, Detailed request for product Approvals -UL File Number: E93617 -CSA File Number: 27324 Technical Data Ratings IEC Ratings UL/CSA Dielectric Strength Allowable Operation Temp. Degree of Protection Protection Class Terminal Panel Thickness s Material: Housing 10 A / 250 VAC; 50 Hz 10 A / 250 VAC; 60 Hz > 3 kVAC between L-N > 1.5 kVAC between L/N-PE (1 min/50 Hz) -25 °C to 70 °C from front side IP 20 acc. to IEC 60529 Suitable for appliances with protection class I or II acc. to IEC 61140 Solder terminals or quick connect terminals Snap-in 1.0 - 2.5 mm PA6, black / grey / white, UL 94V-0 Appliance Inlet Fuseholder Power Acceptance @ Ta > 23°C C14 / C18 acc. to IEC 60320 UL 498, CSA C22.2 no. 42 (for cold conditions) pin-temperature 70 °C, 10 A, Protection Class I or II 1 or 2 pole, acc. to IEC 60127-6, for fuse-links 5 x 20 mm Admissible power acceptance at higher ambient temperature see derating curves Dimensions +0.2 5 26.9 - 0 R R 3 5 16.5 3 <3 4. R 31.5 - 0 31 35 31 +0.2 32 22.2 26.7 28 Length of the terminal please find at the order code configuration table Connectors 1 1064 Power entry modules without line filter www.schurter.com/PG05 Config. Code 1064|-|H|-|A|B|C|N|-|D|-|E|G|O| The characters are placeholders for the correspondingly keys of selections from the key tables. 1064|-| H |-|A|B|C|N|-|D|-|E|G|O| = Type Terminal Ground Type Configuration key protection class II B protection class I X Configuration key Blade terminal (4.8 x 0.8 mm) 8 Blade terminal (6.3 x 0.8 mm) 9 Symbols similar as in table A 1064|-|H|-|A|B|C| N |-|D|-|E|G|O| = Terminal Fuseholder 1064|-|H|-| A |B|C|N|-|D|-|E|G|O| = Terminals Terminal Fuseholder Terminal L Configuration key short solder terminal (L = 4.8 mm) 2 Configuration key solder terminal 1 1064|-|H|-|A|B|C|N|-| D |-|E|G|O| = Color Color long solder terminal (L = 8.5 mm) 3 Blade terminal (4.8 x 0.8 mm) 8 Configuration key Black A Grey B White D Blade terminal (6.3 x 0.8 mm) 9 connection to fuse holder B 1064|-|H|-|A| B |C|N|-|D|-|E|G|O| = Terminals Terminal N 1064|-|H|-|A|B|C|N|-|D|-| E |G|O| = Style Style Configuration key snap-in standard type Configuration key short solder terminal (L = 4.8 mm) 2 long solder terminal (L = 8.5 mm) 3 Blade terminal (4.8 x 0.8 mm) 8 Blade terminal (6.3 x 0.8 mm) 9 connection to fuse holder B 3 1064|-|H|-|A|B|C|N|-|D|-|E| G |O| = Mass S Mass "s" Configuration key 00 The dimension "S" is dispalyed in (1/10 mm). This information is also valid for the order code Symbols similar as in table A 1064|-|H|-|A|B|C|N|-|D|-|E|G| O | = Features 1064|-|H|-|A|B| C |N|-|D|-|E|G|O| = Terminals Terminal Ground Features Configuration key Configuration key dead cover 1 0 holder for 1 or 2 fuses (text legible, when inlet on top) 4 short solder terminal (L = 4.8 mm) 2 holder for 1 or 2 fuses (text legible, when inlet on bottom) 5 long solder terminal (L = 8.5 mm) 3 without terminal Symbols similar as in table A 2 Connectors 1064 Power entry modules without line filter www.schurter.com/PG05 All Variants Config. Code Description Order Number 1064-X-B221-A-3004 1064, IEC Power Entry Module C14, 70°C, version: protection class I, L: connection to fuse holder, N: short solder terminal (L = 4.8 mm), ground: short solder terminal (L = 4.8 mm), fuseholder: solder terminal, color: Black, design: snap-in standard type, dimension S: 00, features: holder for 1 or 2 fuses (text legible, when inlet on top), not used 4304.6025 1064-X-B881-A-3004 1064, IEC Power Entry Module C14, 70°C, version: protection class I, L: connection to fuse holder, N: Blade terminal (4.8 x 0.8 mm), ground: Blade terminal (4.8 x 0.8 mm), fuseholder: solder terminal, color: Black, design: snap-in standard type, dimension S: 00, features: holder for 1 or 2 fuses (text legible, when inlet on top), not used 4304.6026 1064-X-B991-A-3004 1064, IEC Power Entry Module C14, 70°C, version: protection class I, L: connection to fuse holder, N: Blade terminal (6.3 x 0.8 mm), ground: Blade terminal (6.3 x 0.8 mm), fuseholder: solder terminal, color: Black, design: snap-in standard type, dimension S: 00, features: holder for 1 or 2 fuses (text legible, when inlet on top), not used 4304.6027 1064-X-BB21-A-3004 1064, IEC Power Entry Module C14, 70°C, version: protection class I, L: connection to fuse holder, N: connection to fuse holder, ground: short solder terminal (L = 4.8 mm), fuseholder: solder terminal, color: Black, design: snap-in standard type, dimension S: 00, features: holder for 1 or 2 fuses (text legible, when inlet on top), not used 4304.6028 1064-X-BB21-A-3005 1064, IEC Power Entry Module C14, 70°C, version: protection class I, L: connection to fuse holder, N: connection to fuse holder, ground: short solder terminal (L = 4.8 mm), fuseholder: solder terminal, color: Black, design: snap-in standard type, dimension S: 00, features: holder for 1 or 2 fuses (text legible, when inlet on bottom), not used 4304.6029 1064-X-BB81-A-3004 1064, IEC Power Entry Module C14, 70°C, version: protection class I, L: connection to fuse holder, N: connection to fuse holder, ground: Blade terminal (4.8 x 0.8 mm), fuseholder: solder terminal, color: Black, design: snap-in standard type, dimension S: 00, features: holder for 1 or 2 fuses (text legible, when inlet on top), not used 4304.6030 1064-X-BB91-A-3004 1064, IEC Power Entry Module C14, 70°C, version: protection class I, L: connection to fuse holder, N: connection to fuse holder, ground: Blade terminal (6.3 x 0.8 mm), fuseholder: solder terminal, color: Black, design: snap-in standard type, dimension S: 00, features: holder for 1 or 2 fuses (text legible, when inlet on top), not used 4304.6031 1064-X-BB21-D-3004 1064, IEC Power Entry Module C14, 70°C, version: protection class I, L: connection to fuse holder, N: connection to fuse holder, ground: short solder terminal (L = 4.8 mm), fuseholder: solder terminal, color: White, design: snap-in standard type, dimension S: 00, features: holder for 1 or 2 fuses (text legible, when inlet on top), not used 4304.6129 █ █ The listet variants should be available from stock Other versions on request www.schurter.com/contact █ Most Popular. Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER Packaging unit 50 Pcs Accessories Description Assorted Covers Rear Cover Mating Outlets/Connectors Category / Description Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal 4787 IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal 4788 IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal 5091 Appliance Outlet further types to 1064 Connectors 3 1064 Power entry modules without line filter www.schurter.com/PG05 Connector Overview complete 4782 4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4022 4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4785 4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4300-06 4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13 4012 Connector further types to 1064 ... 24.08.2015 4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13 4 Connectors The specifications, descriptions and illustrations indicated in this document are based on current information. All content is subject to modifications and amendments. Information furnished is believed to be accurate and reliable. However, users should independently evaluate the suitability and test each product selected for their own applications.