1064 - Power entry modules without line filter

1064
Power entry modules without line filter
www.schurter.com/PG05
IEC Appliance Inlet C14 or C18 with Fuseholder 1- or 2-pole
Snap-In Version
C14
C18
70° C
70° C
Description
Characteristics
-Panel Mount:
Snap-in version, from front side Appliance Inlet, Protection class I, Fuseholder for fuse-links 5 x 20 mm
-Solder terminals or quick connect terminals
-The fuse drawer "Fingergrip" can be removed by hand
Weblinks
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Mating
Connectors, e-Shop, SCHURTER-Stock-Check, Distributor-StockCheck, CAD-Drawings, Accessories, Detailed request for product
Approvals
-UL File Number: E93617
-CSA File Number: 27324
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temp.
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
10 A / 250 VAC; 50 Hz
10 A / 250 VAC; 60 Hz
> 3 kVAC between L-N
> 1.5 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 70 °C
from front side IP 20 acc. to IEC 60529
Suitable for appliances with protection
class I or II acc. to IEC 61140
Solder terminals or quick connect terminals
Snap-in
1.0 - 2.5 mm
PA6, black / grey / white, UL 94V-0
Appliance Inlet
Fuseholder
Power Acceptance @ Ta >
23°C
C14 / C18 acc. to IEC 60320
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection Class I or II
1 or 2 pole, acc. to IEC 60127-6,
for fuse-links 5 x 20 mm
Admissible power acceptance at higher
ambient temperature see derating curves
Dimensions
+0.2
5
26.9 - 0
R
R
3
5
16.5
3
<3
4.
R
31.5 - 0
31
35
31
+0.2
32
22.2
26.7
28
Length of the terminal please find at the order code configuration table Connectors
1
1064
Power entry modules without line filter
www.schurter.com/PG05
Config. Code
1064|-|H|-|A|B|C|N|-|D|-|E|G|O|
The characters are placeholders for the correspondingly keys of selections from the key tables. 1064|-| H |-|A|B|C|N|-|D|-|E|G|O| = Type
Terminal Ground
Type
Configuration
key
protection class II
B
protection class I
X
Configuration
key
Blade terminal (4.8 x 0.8 mm)
8
Blade terminal (6.3 x 0.8 mm)
9
Symbols similar as in table A
1064|-|H|-|A|B|C| N |-|D|-|E|G|O| = Terminal Fuseholder
1064|-|H|-| A |B|C|N|-|D|-|E|G|O| = Terminals
Terminal Fuseholder
Terminal L
Configuration
key
short solder terminal (L = 4.8 mm)
2
Configuration
key
solder terminal
1
1064|-|H|-|A|B|C|N|-| D |-|E|G|O| = Color
Color
long solder terminal (L = 8.5 mm)
3
Blade terminal (4.8 x 0.8 mm)
8
Configuration
key
Black
A
Grey
B
White
D
Blade terminal (6.3 x 0.8 mm)
9
connection to fuse holder
B
1064|-|H|-|A| B |C|N|-|D|-|E|G|O| = Terminals
Terminal N
1064|-|H|-|A|B|C|N|-|D|-| E |G|O| = Style
Style
Configuration
key
snap-in standard type
Configuration
key
short solder terminal (L = 4.8 mm)
2
long solder terminal (L = 8.5 mm)
3
Blade terminal (4.8 x 0.8 mm)
8
Blade terminal (6.3 x 0.8 mm)
9
connection to fuse holder
B
3
1064|-|H|-|A|B|C|N|-|D|-|E| G |O| = Mass S
Mass "s"
Configuration
key
00
The dimension "S" is dispalyed in (1/10 mm). This information is also valid for the
order code
Symbols similar as in table A
1064|-|H|-|A|B|C|N|-|D|-|E|G| O | = Features
1064|-|H|-|A|B| C |N|-|D|-|E|G|O| = Terminals
Terminal Ground
Features
Configuration
key
Configuration
key
dead cover
1
0
holder for 1 or 2 fuses (text legible, when inlet on top)
4
short solder terminal (L = 4.8 mm)
2
holder for 1 or 2 fuses (text legible, when inlet on bottom)
5
long solder terminal (L = 8.5 mm)
3
without terminal
Symbols similar as in table A
2
Connectors
1064
Power entry modules without line filter
www.schurter.com/PG05
All Variants
Config. Code
Description
Order Number
1064-X-B221-A-3004 1064, IEC Power Entry Module C14, 70°C, version: protection class I, L: connection to fuse holder, N: short solder terminal (L = 4.8
mm), ground: short solder terminal (L = 4.8 mm), fuseholder: solder terminal, color: Black, design: snap-in standard type, dimension S: 00, features: holder for 1 or 2 fuses (text legible, when inlet on top), not used
4304.6025
1064-X-B881-A-3004 1064, IEC Power Entry Module C14, 70°C, version: protection class I, L: connection to fuse holder, N: Blade terminal (4.8 x 0.8
mm), ground: Blade terminal (4.8 x 0.8 mm), fuseholder: solder terminal, color: Black, design: snap-in standard type, dimension S:
00, features: holder for 1 or 2 fuses (text legible, when inlet on top), not used
4304.6026
1064-X-B991-A-3004 1064, IEC Power Entry Module C14, 70°C, version: protection class I, L: connection to fuse holder, N: Blade terminal (6.3 x 0.8
mm), ground: Blade terminal (6.3 x 0.8 mm), fuseholder: solder terminal, color: Black, design: snap-in standard type, dimension S:
00, features: holder for 1 or 2 fuses (text legible, when inlet on top), not used
4304.6027
1064-X-BB21-A-3004 1064, IEC Power Entry Module C14, 70°C, version: protection class I, L: connection to fuse holder, N: connection to fuse holder,
ground: short solder terminal (L = 4.8 mm), fuseholder: solder terminal, color: Black, design: snap-in standard type, dimension S:
00, features: holder for 1 or 2 fuses (text legible, when inlet on top), not used
4304.6028
1064-X-BB21-A-3005 1064, IEC Power Entry Module C14, 70°C, version: protection class I, L: connection to fuse holder, N: connection to fuse holder,
ground: short solder terminal (L = 4.8 mm), fuseholder: solder terminal, color: Black, design: snap-in standard type, dimension S:
00, features: holder for 1 or 2 fuses (text legible, when inlet on bottom), not used
4304.6029
1064-X-BB81-A-3004 1064, IEC Power Entry Module C14, 70°C, version: protection class I, L: connection to fuse holder, N: connection to fuse holder,
ground: Blade terminal (4.8 x 0.8 mm), fuseholder: solder terminal, color: Black, design: snap-in standard type, dimension S: 00,
features: holder for 1 or 2 fuses (text legible, when inlet on top), not used
4304.6030
1064-X-BB91-A-3004 1064, IEC Power Entry Module C14, 70°C, version: protection class I, L: connection to fuse holder, N: connection to fuse holder,
ground: Blade terminal (6.3 x 0.8 mm), fuseholder: solder terminal, color: Black, design: snap-in standard type, dimension S: 00,
features: holder for 1 or 2 fuses (text legible, when inlet on top), not used
4304.6031
1064-X-BB21-D-3004 1064, IEC Power Entry Module C14, 70°C, version: protection class I, L: connection to fuse holder, N: connection to fuse holder,
ground: short solder terminal (L = 4.8 mm), fuseholder: solder terminal, color: White, design: snap-in standard type, dimension S:
00, features: holder for 1 or 2 fuses (text legible, when inlet on top), not used
4304.6129
█
█
The listet variants should be available from stock Other versions on request www.schurter.com/contact
█ Most Popular.
Availability for all products can be searched real-time:http://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER
Packaging unit 50 Pcs Accessories
Description
Assorted Covers
Rear Cover
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete
IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder Terminal
4787
IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
4788
IEC Appliance Outlet F or H, Screw-on Mounting, Front Side, Solder, PCB or Quick-connect Terminal
5091
Appliance Outlet further types to 1064
Connectors
3
1064
Power entry modules without line filter
www.schurter.com/PG05
Connector Overview complete
4782
4022 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13
4022
4785 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4785
4300-06 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4300-06
4012 Mounting: Power Supply Cord, 3 x 1.5 mm², Screw clamps, Connector: IEC C13
4012
Connector further types to 1064
...
24.08.2015
4782 Mounting: Power Cord, 3 x 1 mm² / 3 x 18 AWG, Cable, Connector: IEC C13
4
Connectors
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.