4781 - Cord Connectors (rewireable)

4781
Cord Connectors (rewireable)
www.schurter.com/PG07b
IEC Connector C15 for hot conditions 120°C, Rewireable, Straight
Rewireable connector
Example with assembled cable
4781
C15
120° C
Description
Weblinks
-Cord Connectors (rewireable):
Screw
-1 Function:
-Connector, Pin temperature 120 °C, Protection class I
-Cable
pdf-datasheet, html-datasheet, General Product Information, Approvals,
CE declaration of conformity, RoHS, CHINA-RoHS, REACH, Mating
Connectors, e-Shop, SCHURTER-Stock-Check, Distributor-StockCheck, CAD-Drawings, Accessories, Detailed request for product
Approvals
-VDE Certificate Number: 40031778
-UL File Number: E96454
-CSA File Number: 56242
Technical Data
Ratings IEC
Ratings UL/CSA
Dielectric Strength
Allowable Operation Temp.
Protection Class
Terminal
Material: Housing
10 A / 250 VAC; 50 Hz
15 A / 250 VAC; 60 Hz
> 2 kVAC between L-N
> 2 kVAC between L/N-PE
(1 min/50 Hz)
-25 °C to 120 °C
Suitable for appliances with protection
class I acc. to IEC 61140
Cable
Thermoplastic, black, UL 94V-0
Connector
C15 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for hot conditions) pin-temperature 120 °C, 10 A,
Protection Class I
Dimensions
4781
62.0
28.7
21.0
87.5
All Variants
Color
Max. cable diameter
Max. wire size
Order Number
black
8.5 mm
3 x 1 mm² / 3 x 18 AWG
4781.0000
█
black
10 mm
3 x 2.1 mm² / 3 x 14 AWG
4781.0100
█
Max. torque for screws: Terminals: 0.5 Nm, Cable clamps: 0.3 Nm, Cover: 0.3 Nm
Packaging unit 100 Pcs Connectors
1
4781
Cord Connectors (rewireable)
www.schurter.com/PG07b
Accessories
Description
Cord retaining kits
Cord retaining strain relief
Flat head, A
4700.0001
Countersunk, B
4700.0002
Countersunk, C
4700.0003
Flat head, E
4700.0005
...
Mating Inlets/Plugs
Category / Description
Appliance Inlet Overview complete
6100-3, Mounting: Screw, Solder terminals or quick connect terminals, Appliance Inlet: IEC C14
6100-3
6100-4, Mounting: Snap-in, Solder terminals or quick connect terminals, Appliance Inlet: IEC C14
6100-4
IEC Appliance Inlet C18, Screw-on Mounting, Front or Rear Side, Solder or Quick-connect Terminal
6102-3
IEC Appliance Inlet C18, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal
6102-5
G-Stecker, Mounting: Appliance Inlet : IEC C14 Without fuse holder
6150
Appliance Inlet further types to 4781
...
Distribution Unit Overview complete
Distribution Unit for Snap-in Mounting with 1 IEC Appliance Inlet C14 and 1 Appliance Outlet F
0712
Distribution Unit with 1 IEC Appliance Inlet C14 and 2 Appliance Outlets F, Shuttered
4741
Distribution Unit with 1 IEC Appliance Inlet C14 and 4 Appliance Outlets F
4747
Distribution Unit with 1 IEC Appliance Inlet C14 or Power Cord, 5 or 6 IEC Appliance Outlets F and Extra Components
4740
EMC Power Strip with Line Filter
FLBB
Distribution Unit further types to 4781
Plug Overview complete
IEC Plug E, Cord Connector (Rewireable), Straight, max. cable Diameter 8.5 mm
4732
IEC Plug E, Cord Connector (Rewireable), Straight, max. Cable Diameter 10 mm
4735
IEC Plug E, Cord Connector (Rewireable), Straight
9009
IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 8.5 mm
4733
IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 10 mm
4736
Plug further types to 4781
...
Power Entry Module Overview complete
DC11, Mounting: Screw, Rocker switch: non-illuminated or illuminated 1 or 2 pole, Quick connect terminals 4.8 x 0.8
mm, Appliance Inlet: IEC C14, Without fuse holder: Suitable for appliances with protection class I or II
DC11
KEB1, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, Without fuse holder: Rocker switch, non-illuminated or
illuminated, red, 1-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I
KEB1
KEB2, Mounting:Screw, Quick connect terminals 4.8 x 0.8 mm, Without fuse holder: Rocker switch, non-illuminated or
illuminated, 2-pole, Appliance Inlet: IEC C14, 250 VAC, prewired, Suitable for appliances with protection class I
KEB2
DC21, Mounting: Screw Rear Side, Rocker switch: non-illuminated or illuminated 2-pole, Quick connect terminals 4.8
x 0.8 mm Appliance Inlet: IEC C14, Without fuse holder:
DC21
DD11, Mounting: Screw-on mounting, Rocker switch: non-illuminated or illuminated 2-pole, Quick connect terminals
4.8 x 0.8 mm, Appliance Inlet: IEC C14, With or without protection cover, Fuse holder: 1 or 2 pole, Suitable for appliances with protection class I
DD11
Power Entry Module further types to 4781
2
Connectors
...
4781
Cord Connectors (rewireable)
www.schurter.com/PG07b
Category / Description
Power Entry Module with line filter Overview complete
KFB1, Mounting: Screw, Front Side, Filter: Standard Version, Without fuse holder: 10 A, Rocker switch: 1-pole, Appliance Inlet: IEC C14, prewired
KFB1
KFB2, Mounting: Screw, Front Side, Filter: Standard and Medical Version, Without fuse holder: 10 A, Rocker switch:
2-pole, Appliance Inlet: IEC C14, prewired
KFB2
DC12, Mounting: Screw, Front-/Rear-Side, Filter, Standard and Medical Version, Without fuse holder:10 A, Rocker
switch: 1 or 2 pole, non-illuminated or illuminated Appliance Inlet: IEC C14, prewired
DC12
DC22 Mounting: Screw, Rear Side, PCB, 10 A, Filter: Standard and Medical Version, Without fuse holder: Rocker switch:
DC22
1 or 2 pole, non-illuminated or illuminated, Appliance Inlet: IEC C14, Suitable for appliances with protection class I
DD12, Mounting: Screw-on mounting, Front Side, Filter, Standard and Medical Version, Fuse holder:1 or 2 pole, 10 A,
Rocker switch: 2-pole, non-illuminated Appliance Inlet: IEC C14, prewired
...
29.09.2015
Power Entry Module with line filter further types to 4781
DD12
The specifications, descriptions and illustrations indicated in this document are based on current
information. All content is subject to modifications and amendments. Information furnished is believed
to be accurate and reliable. However, users should independently evaluate the suitability and test each
product selected for their own applications.
Connectors
3