TLD1040-24-C1050 - Triad Magnetics

Switch Mode Power Supplies
Encapsulated Constant Current
TLD1040-24-C1050
Description:
The TLD1040-24-C1050 is a compact and lightweight Constant Current Switch Mode Power Supply.
Waterproof design within a 2x4 J box, IP66, NEMA 4 suitable for dry and damp locations.
Convection cooled plastic housing. Designed for outdoor and indoor applications. Some typical
applications include LED’s, Lighting, etc.
Specifications (@25C)
Electrical Specifications:
1
100-304Vac
47-63Hz
0.5A @ 115Vac; 0.25A @ 230Vac
<5A@115Vac, 10A@230Vac
>0.9 at full load, 115Vac
1.050Adc±5%, 12-24Vdc
1.5 Max.
300µA Typical
84% Typical at full load
±1% (when applicable)
±3%
Half cycle minimum at 120 VAC and 80% of rated voltage
Over-voltage, Over current and Short circuit protection:
Auto-recovery
5 (0.20)
4 (0.16)
(2X)
(2X)
95 (3.74)
Bottom
Operating Temperature:
Storage Temperature:
Operating Humidity:
Cooling:
Vibration:
MTBF:
EMC:
DC OUTPUT
WIRES
Environmental Specifications:
-30 to 60°C (De-rating: 1%/°C from 60-70°C)
-40 to 85°C
5 to 95% RH (non-Condensing)
Convection cooling
5 to 50Hz
>100,000 Hours at full load and 25°C ambient conditions
Compliant to 47CFR, Part 2, Part 15 and Cispr PUB, 22
Class B
3.6 (0.14)
(2X)
70 (2.76)
32 (1.26)
General Specifications:
Connections:
Dimensions (WxLxH):
Weight:
Warranty:
10 (0.39)
(2X)
5in leads - Input: 18 AWG; Output: 18 AWG
70.0x95.0x32.0mm
220g
3 years @ 40°C, 100% Load
Safety Standards:
Standards:
UL (cUL) 1310, UL48
CE
RoHS Compliance: As of manufacturing date February 2005, all standard products meet the requirements
of 2011/65/EU, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact Triad Magnetics’ website for the
most current version.
1
Parts manufactured before November, 2010 have an input voltage range of 90 – 264VAC.
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
460 Harley Knox Blvd.
Perris, California 92571
Publish Date: December 4, 2013
10 (0.39)
(2X)
AC OUTPUT
WIRES
5 (0.20)
(2X)
Input Voltage:
Input Frequency Range:
Max Input Current:
Max Inrush Current:
Power Factor:
Output:
Crest Factor (Ipk):
Leakage Current:
Efficiency:
Current Accuracy:
Load Regulation:
Hold up time:
Protection: