TS1001, A 0.8 V, 0.6 µA OP-AMP

AN833
S UB -1 V C URRENT S E N S I N G WITH TH E TS1001,
A 0 .8 V, 0. 6 µA O P - A M P
1. Introduction
Current-sense amplifiers can monitor battery or solar cell currents, and are useful to estimate power capacity and
remaining life. However, if the battery or solar source is a single cell, it’s difficult to find a low voltage solution that
works below 1V and draws just microamps. A new class of nanopower analog ICs, namely the TS1001 0.8 V/
0.6 µA op amp, makes a sub-1 V supply current sense amplifier shown in Figure 1 possible. This discrete circuit
operates from as low as 0.8 V and draws 860 nA at no load while providing a 0–500 mV output for measured
currents of 0–100 mA, though the scale can be adjusted by changing the values of a few resistors. With its
extremely low power, the circuit can simply remain “always on,” providing a continuously monitored, averaged
indication of current which can subsequently be read periodically by a microcontroller, without causing too much
current drain in the battery.
2. Overview
The circuit can be used to estimate the impedance of a small coin-cell type alkaline battery to determine its
condition, its ability to source power, and estimate its remaining life. Measuring the battery voltage (without
knowing the load) generally provides only a crude estimate, and performing “pulse tests” as recommended by
some battery manufacturers can be disruptive to the circuit the battery is powering.
Figure 1. Low Voltage Current Sense Amplifier Utilizing Nanopower Op-Amp and Low-Threshold
P-Channel MOSFET
The TS1001 is configured to servo P-channel MOSFET Q1 in a current source configuration, drawing current
through R1 to compensate for the voltage drop across R2 caused by the current flow from IN to the load. R3
converts Q1’s drain current to a voltage and C1 provides filtering. The filtering is critical in allowing the current
sense amplifier to continuously provide an averaged current output, enabling the microcontroller to sleep for long
periods and save power, waking only periodically to read this mean current level.
Rev. 1.1 8/14
Copyright © 2014 by Silicon Laboratories
AN833
AN833
Figure 2. Measured V_iload vs. Input Current
Table 1. Current Sense Amplifier Circuit Supply Current vs. Load Current
Load Current
Current Used by the Current Sense Amplifier
0
860 nA
50 mA
48.1 µA
Amplifier input offset voltages need to be considered carefully in this circuit. The TS1001 op amp is specified with
±3 mV maximum input offset voltage at 25 °C, which corresponds to ±3 mA of error. Figure 2 shows an offset of
approximately 2.5 mA. Another consideration is that Q1 exhibits drain-source leakage current of a few 10s of
nanoamps at 25 °C and can approach 1µA over the commercial temperature range. Since the current through Q1
is effectively controlled by the TS1001’s loop, any drain-source leakage from Q1 appears as a current floor and
generates a corresponding minimum voltage output across R3 below which current cannot be measured until the
op amp “takes over” at higher measured currents. Therefore, normal methods of removing the current sense
amplifier input offset voltage by subtracting the zero-load voltage at V_iin will not work, since the offset voltage due
to the op amp’s Vos and the current floor from Q1’s drain-source leakage cannot be separated.
2
Rev. 1.1
AN833
Figure 3. Ultra-Low Supply Current Amplifier Circuit with Amplifier Offset Voltage Correction
Figure 3 shows an alternative configuration which provides a means for calibrating out the amplifier offset voltage.
The circuit is set up for measuring very low currents, in this case from three series-connected PIN solar cells. The
circuit can be used as part of an energy harvesting system in a maximum-power-point-tracking (MPPT) scheme,
where the microcontroller adjusts the loading of the cells to maximize V x I and yield the maximum available power.
The circuit works in a similar way to Figure 1, but it has been scaled for a selectable 100 µA/500 µA full scale
current where the full-scale sensed voltage across R2 has been decreased to 50 mV to improve efficiency. With
this lower voltage, the ±3 mV specified input offset voltage of the TS1001 causes up to a 6% offset error, which
may be unacceptable.
This offset may be calibrated out using the principal of making two measurements of the same parameter at the
two gain settings. The offset then can be found as:
ZKHUH9LORDGB*DQG9LORDGB*DUHWKHPHDVXUHPHQWVPDGHZLWKORZUDQJHDQGKLJKUDQJHPRGHUHVSHFWLYHO\DQGZKHUH
Microcontroller-based systems power budgets have dropped dramatically in recent years, enabling these systems
to be powered from sources such as coin batteries and miniature solar cells. Analog circuits such as this
micropower current-sense amplifier, which remain always on, draw very little power from the power source, and are
becoming increasingly useful to save yet more system power by allowing the microcontroller to remain sleeping
while the circuit stays awake monitoring and averaging battery parameters. For additional information, see the
TS1001 Op Amp documentation.
Rev. 1.1
3
AN833
DOCUMENT CHANGE LIST
Revision 1.0 to Revision 1.1

4
Updated document title.
Rev. 1.1
AN833
CONTACT INFORMATION
Silicon Laboratories Inc.
400 West Cesar Chavez
Austin, TX 78701
Tel: 1+(512) 416-8500
Fax: 1+(512) 416-9669
Toll Free: 1+(877) 444-3032
Please visit the Silicon Labs Technical Support web page:
https://www.siliconlabs.com/support/pages/contacttechnicalsupport.aspx
and register to submit a technical support request.
Patent Notice
Silicon Labs invests in research and development to help our customers differentiate in the market with innovative low-power, small size, analogintensive mixed-signal solutions. Silicon Labs' extensive patent portfolio is a testament to our unique approach and world-class engineering team.
The information in this document is believed to be accurate in all respects at the time of publication but is subject to change without notice.
Silicon Laboratories assumes no responsibility for errors and omissions, and disclaims responsibility for any consequences resulting from
the use of information included herein. Additionally, Silicon Laboratories assumes no responsibility for the functioning of undescribed features or parameters. Silicon Laboratories reserves the right to make changes without further notice. Silicon Laboratories makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does Silicon Laboratories assume any
liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation
consequential or incidental damages. Silicon Laboratories products are not designed, intended, or authorized for use in applications intended to support or sustain life, or for any other application in which the failure of the Silicon Laboratories product could create a situation where
personal injury or death may occur. Should Buyer purchase or use Silicon Laboratories products for any such unintended or unauthorized
application, Buyer shall indemnify and hold Silicon Laboratories harmless against all claims and damages.
Silicon Laboratories and Silicon Labs are trademarks of Silicon Laboratories Inc.
Other products or brandnames mentioned herein are trademarks or registered trademarks of their respective holders.
Rev. 1.1
5