sh08 series electrical specifications key features

VER : B_0
update : 2012.01.20
Encapsulated DC-DC Converter
SH08 SERIES
8 Watts
KEY FEATURES
„ Power Module for PCB Mountable
„ High Efficiency and Reliability
„ 4:1 Wide Input Range
„ Single and Dual Output
„ Regulated Output
„ Low Ripple and Noise
„ 3-Years Product Warranty
ELECTRICAL SPECIFICATIONS
Model No. ( Single Output )
Input Voltage (V.DC.)
Output Voltage (V.DC.)
SH08-24F-3.3S
24V (9-36V)
3.3V/2200mA
SH08-24F-5S
24V (9-36V)
5V/1600mA
SH08-24F-12S
24V (9-36V)
12V/666mA
SH08-24F-15S
24V (9-36V)
15V/533mA
SH08-24F-24S
24V (9-36V)
24V/333mA
Efficiency (typ.)
79%
82%
82%
81%
81%
Capacitor Load (max)
2000 uF
800 uF
2200 uF
3000 uF
630 uF
Model No. ( Single Output )
Input Voltage (V.DC.)
Output Voltage (V.DC.)
SH08-48F-3.3S
48V (18-75V)
3.3V/2200mA
SH08-48F-5S
48V (18-75V)
5V/1600mA
SH08-48F-12S
48V (18-75V)
12V/666mA
SH08-48F-15S
48V (18-75V)
15V/533mA
SH08-48F-24S
48V (18-75V)
24V/333mA
Efficiency (typ.)
80%
84%
84%
83%
83%
Capacitor Load (max)
85000 uF
70000 uF
2600 uF
3400 uF
1800 uF
SH08-24F-3.3S
SH08-24F-5S
SH08-24F-12S
SH08-24F-15S
SH08-24F-24S
SH08-48F-3.3S
SH08-48F-5S
SH08-48F-12S
SH08-48F-15S
SH08-48F-24S
12
15
24
666
533
333
Model No.
( Single Output )
Max Output Wattage (W)
Input
Input Filter
Voltage (V.DC.)
Voltage Accuracy
Current (mA) max
Line Regulation (LL-HL) (typ.)
Output
Load Regulation (10-100%) (typ.)
Minimum Load
Ripple
Noise
Switching Frequency
Over Power Protection
Protection
Short Circuit Protection
Voltage
Isolation
Environment
Physical
8W
Resistance
π type
3.3
5
±2%
2200
1600
±0.5%
±1%
0%
50 mV max.
100 mV max.
300KHz
Above 105% Rated Output Power
Current limit, auto-recovery
1600 VDC.
108 ohms
Capacitance
Operating Temperature
Storage Temperature
Case Temperature
Temperature Coefficient
Humidity
MTBF
Dimension (L x W x H)
Case Material
Weight
Cooling Method
1000 pF
-25°C…+60°C (at Full Load)
-55°C…+105°C
+100°C max.
±0.02% Per°C
95% RH
>800,000 h @ 25°C (MIL-HDBK-217F)
1.25 x 0.8 x 0.44 Inches ( 31.8 x 20.3 x 11.2 mm ) Tolerance ±0.5 mm
Nickel-Coated Copper with Non-Conductive Base, Six-side shielded.
20 g
Free-air convection
1.All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
2. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-1-
VER : B_0
update : 2012.01.20
Encapsulated DC-DC Converter
SH08 SERIES
8 Watts
Model No. ( Dual Output )
Input Voltage (V.DC.)
Output Voltage (V.DC.)
SH08-24F-5D
24V (9-36V)
±5V / ±800mA
SH08-24F-12D
24V (9-36V)
±12 / ±333mA
SH08-24F-15D
24V (9-36V)
±15 / ±267mA
Efficiency (typ.)
Capacitor Load (max)
82%
±6600 uF
85%
±1000 uF
85%
±200 uF
Model No. ( Dual Output )
Input Voltage (V.DC.)
Output Voltage (V.DC.)
SH08-48F-5D
48V (18-75V)
±5V / ±800mA
SH08-48F-12D
48V (18-75V)
±12 / ±333mA
SH08-48F-15D
48V (18-75V)
±15 / ±267mA
Efficiency (typ.)
82%
±28000 uF
85%
±720 uF
85%
±350 uF
SH08-24F-5D
SH08-24F-12D
SH08-24F-15D
SH08-48F-5D
SH08-48F-12D
SH08-48F-15D
Capacitor Load (max)
Model No.
( Dual Output )
Max Output Wattage (W)
Input
Input Filter
Voltage (V.DC.)
Voltage Accuracy
Current (mA) max
Line Regulation (LL-HL) (typ.)
Output
Load Regulation (10-100%) (typ.)
Minimum Load
Ripple
Noise
Switching Frequency
Over Power Protection
Protection
Short Circuit Protection
Voltage
Isolation
Environment
Physical
8W
Resistance
π type
±5
±12
±2%
±800
±333
±0.5%
±1%
0%
50 mV max (Vp-p)
<0.5% Vout +50mV max (Vp-p)
300KHz
Works over 120% of rating and recovers automatically.
Current limit, auto-recovery
1600 VDC.
108 ohms
Capacitance
Operating Temperature
Storage Temperature
Case Temperature
Temperature Coefficient
Humidity
MTBF
Dimension (L x W x H)
Case Material
Weight
Cooling Method
1000 pF
-25°C…+60°C (at Full Load)
-55°C…+105°C
+100°C max.
±0.02% Per°C
95% RH
>800,000 h @ 25°C (MIL-HDBK-217F)
1.25 x 0.8 x 0.44 Inches ( 31.8 x 20.3 x 11.2 mm ) Tolerance ±0.5 mm
Nickel-Coated Copper with Non-Conductive Base, Six-side shielded.
20 g
Free-air convection
±15
±267
1.All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated.
2. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor.
OUTPUT NOISE
The output noise is measured with 0.1μF tantalum capacitor
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
VER : B_0
update : 2012.01.20
Encapsulated DC-DC Converter
SH08 SERIES
MECHANICAL DIMENSION
8 Watts
( Top View )
BLOCK DIAGRAM
http://www.archcorp.com.tw
TEL: +886-2-26989508 FAX: +886-2-26981319
PIN#
Single
Dual
1
-VIN
-VIN
2
-VIN
-VIN
3
NO PIN
COMMON
4
NC
-VOUT
5
+VOUT
+VOUT
6
-VOUT
COMMON
7
+VIN
+VIN
8
+VIN
+VIN
DERATING
-3-