VER : C_5 update : 2015.03.09 AC-DC Switching Power Supply AQF240U SERIES 240 Watts A Type KEY FEATURES (except 5S) U Bracket Switching Power Supply Universal Input: 90-264 VAC With P.F.C. Function, PF>0.95 Free Air Convection High Efficiency up to 93% RoHS Compliant Design Ultra Compact Size: 6.0 x 4.18 x 1.38 Inches 3-Year Product Warranty ELECTRICAL SPECIFICATIONS All specifications valid at normal input voltage, full load and +25°C after warm-up time unless otherwise stated. AQF240 U-5S 180W Model No. Max Output Wattage (W) Voltage Input Output Protection Isolation AQF240 U-24S AQF240 U-28S AQF240 U-36S AQF240 U-32S AQF240 U-48S 90-264 VAC or 120-370 VDC 47-63 Hz Current (Full load) <3.0 A max. (115 VAC) / <1.5 A max. (230 VAC) Inrush Current (<2ms) < 30 A max. (115 VAC) / < 60 A max. (230 VAC) Leakage Current < 0.5 mA max. Power Factor PF>0.98 (115 VAC) / PF>0.95 (230 VAC) at Full Load Voltage (V.DC.) 5V Voltage Accuracy ±2% 12V 15V 24V 28V 36V 32V 48V 20 16 10 8.57 6.66 7.5 5 92% 92% 92% 92% 93% Current (Convection) (A) max 36 Line Regulation ±1% Load Regulation Minimum Load Maximum Capacitive Load ±1% 5% 2% 470-23,000µF depending on model Ripple & Noise (max.) 150mVp-p 120mVp-p 200mVp-p Efficiency (at 230VAC) 87% 90% 90% Hold-up Time 13 ms min. Over Power Protection Auto recovery Over Voltage Protection Latch Off Short Circuit Protection Latch Off Input-Output (V.AC) 4000VAC or 5656VDC Input-FG (V.AC) 2000V Output-FG .(V.AC) 500V -10°C…+70°C (with derating) Storage Temperature -25°C…+85°C Temperature Coefficient ±0.03%/°C ( 0~50°C ) Humidity 95% RH MTBF >50,000 h @ 25°C (MIL-HDBK-217F) Vibration Dimension (L x W x H) Physical AQF240 U-15S Frequency (Hz) Operating Temperature Environment AQF240 U-12S 240W Weight 10~500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes. 5S: 6.0 x 4.18 x 1.46 Inches (150.0 x 106.0 x 37.0 mm ) Tolerance 0.5 mm Others: 6.0 x 4.18 x 1.38 Inches (150.0 x 106.0 x 35.0 mm ) Tolerance 0.5 mm 580 g Cooling Method Free convection Safety Agency Approvals EMI CE, UL60950(except 5S), CB(except 5S) EMC (Conducted & Radiated Emission) EMS (Noise Immunity) http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 EN 55022 class B EN 55024 -1- VER : C_5 update : 2015.03.09 AC-DC Switching Power Supply AQF240U SERIES 240 Watts NOTE 1. Ripple & Noise are measured at 20MHz of bandwidth with 0.1uF & 47uF parallel capacitor. 2. Strongly recommend to conduct this test with DC Voltage. If customer wishes to test with AC Voltage, please disconnect all Y-Capacitors within Arch power supply. DERATING BLOCK DIAGRAM http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -2- VER : C_5 update : 2015.03.09 AC-DC Switching Power Supply AQF240U SERIES MECHANICAL DIMENSION 240 Watts ( Top View ) Standard (5S) PIN# Single 1 AC IN (L) 2 AC IN (N) 3 FG 4 +DC OUT 5 +DC OUT 6 -DC OUT 7 -DC OUT ASSEMBLY INSTRUCTIONS *U Case T=2.0mm Customer is advised to screw into the threads no more than 2.0mm http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -3- VER : C_5 update : 2015.03.09 AC-DC Switching Power Supply AQF240U SERIES 240 Watts Standard (12S、15S、24S、28S、32S、48S) PIN# Single 1 AC IN (L) 2 AC IN (N) 3 FG 4 +DC OUT 5 +DC OUT 6 -DC OUT 7 -DC OUT ASSEMBLY INSTRUCTIONS *U Case T=2.0mm Customer is advised to screw into the threads no more than 2.0mm A Type (except 5S) http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 PIN# Single 1 AC IN (L) 2 AC IN (N) 3 FG 4~7 +DC OUT 8~11 -DC OUT -4-