SMA Male to SMA Male Low Loss Test Cable Using PE

SMA Male to SMA Male Low Loss Test Cable
Using PE-P300LL Coax, RoHS
TECHNICAL DATA SHEET
PE333
The PE330 high performance test cable’s 0.3 inch diameter and 83% phase velocity offer very low loss performance up to 18
GHz. The durable stainless steel connectors and FEP jacket provide a cost effective design ideal for test environments where
a rugged cable assembly is required. The series is offered with Type N, TNC, and SMA connectors all rated to 18 GHz. A
heavy Duty boot provides improved strain relief and adds to the durability of the cable assemblies. These cable assemblies
are built using a double shielded flexible cable, providing excellent shielding effectiveness of greater than 95 dB. All PE330
cable assemblies are 100% Continuity, Hi-POT, and RF tested to published specifications. Custom lengths are built to order
and shipped same day.
•
•
•
•
•
•
•
•
83% Velocity of Propagation
Shielding effectiveness > 95 dB
Maximum VSWR is < 1.35:1 to 18 GHz
Minimum Bend Radius of 1.5 inches
Operating Temperature range of -55 to +125 °C
ROHS and REACH Compliant
Same day shipment of custom lengths
100% Continuity, Hi-Pot, and RF tested
Configuration
Connector 1
Connector 2
Cable Type
SMA Male
SMA Male
PE-P300LL
Electrical Specifications
Frequency Range
Impedance
Maximum VSWR
Velocity of Propagation
RF Shielding
DC to 18 GHz
50 Ohms
1.35:1
83 %
95 dB
Typical Performance by Frequency
Frequency 1
Frequency
Insertion Loss
Power Handling, KWatts
400 MHz
0 dB/ft [0.10 dB/m]
2.9
Frequency 2
Frequency
Insertion Loss
Power Handling
1000 MHz
0.05 dB/ft [0.16 dB/m]
1.8 KWatts
Frequency 3
Frequency
Insertion Loss
Power Handling
2 GHz
0.07 dB/ft [0.23 dB/m]
1.2 KWatts
Click the following link (or enter part number in “SEARCH” on website) to obtain additional part information including price,
inventory and certifications: SMA Male to SMA Male Low Loss Test Cable Using PE-P300LL Coax, RoHS PE333
PE333 REV 1.0
1
SMA Male to SMA Male Low Loss Test Cable
Using PE-P300LL Coax, RoHS
TECHNICAL DATA SHEET
PE333
Frequency 4
Frequency
Insertion Loss
Power Handling
3 GHz
0.08 dB/ft [0.26 dB/m]
1.05 KWatts
Frequency 5
Frequency
Insertion Loss
Power Handling
5 GHz
0.11 dB/ft [0.36 dB/m]
850 Watts
Frequency 6
Frequency
Insertion Loss
Power Handling
10 GHz
0.16 dB/ft [0.52 dB/m]
600 Watts
Frequency 7
Frequency
Insertion Loss
Power Handling
18 GHz
0.22 dB/ft [0.72 dB/m]
400 Watts
Electrical Specification Notes:
Power handling values are calculated based on Cable
properties. Power handling will vary based on the actual
VSWR of the cable assembly.
Mechanical Specifications
Temperature
Temperature Operating Range
-55 to +125 deg C
Size
Diameter
0.62 in [15.75 mm]
Weight
Cable Color
Repeated Minimum Bend Radius
0.1 lbs [45.36 g]
Green
1.5 in [38.1 mm]
Cable
Cable Type
Cable Inner Conductor
No of Shields
Cable Outer Conductor
Dielectric Type
Jacket Material
Jacket Diameter
PE-P300LL
Copper, Silver
2
Copper, Silver
PTFE
FEP
0.3 in [7.62 mm]
Connector 1
Type Connector 1 Specification
SMA Male
MIL-STD-348, Figure 310-1.
.
Click the following link (or enter part number in “SEARCH” on website) to obtain additional part information including price,
inventory and certifications: SMA Male to SMA Male Low Loss Test Cable Using PE-P300LL Coax, RoHS PE333
PE333 REV 1.0
2
SMA Male to SMA Male Low Loss Test Cable
Using PE-P300LL Coax, RoHS
TECHNICAL DATA SHEET
PE333
Configuration
Inner Conductor Material and Plating Inner Conductor Plating Specification
Outer Conductor Material and Plating Outer Conductor Plating Specification
Coupling Nut Material and Plating Coupling Nut Plating Specification
Hex Size
Torque
Body Material and Plating
Body Plating Specification
Dielectric Type Straight
Beryllium Copper, Gold
ASTM-B488 50µ In.
Passivated Stainless Steel
SAE-AMS-2700
Passivated Stainless Steel
SAE-AMS-2700
5/16 Inch
8 in-lbs [0.9 Nm]
Passivated Stainless Steel
SAE-AMS-2700
PTFE
Connector 2
Type
Connector 2 Specification
Configuration
Inner Conductor Material and Plating
Inner Conductor Plating Specification
Outer Conductor Material and Plating
Outer Conductor Plating Specification
Coupling Nut Material and Plating
Coupling Nut Plating Specification
Hex Size
Torque
Body Material and Plating
Body Plating Specification
Dielectric Type
SMA Male
MIL-STD-348, Figure 310-1.
Straight
Beryllium Copper, Gold
ASTM-B488 50µ In.
Passivated Stainless Steel
SAE-AMS-2700
Passivated Stainless Steel
SAE-AMS-2700
5/16 Inch
8 in-lbs [0.9 Nm]
Passivated Stainless Steel
SAE-AMS-2700
PTFE
Compliance Certifications (visit www.Pasternack.com for current document)
RoHS Compliant
Yes
Click the following link (or enter part number in “SEARCH” on website) to obtain additional part information including price,
inventory and certifications: SMA Male to SMA Male Low Loss Test Cable Using PE-P300LL Coax, RoHS PE333
PE333 REV 1.0
3
SMA Male to SMA Male Low Loss Test Cable
Using PE-P300LL Coax, RoHS
TECHNICAL DATA SHEET
PE333
Plotted and Other Data
Notes:
• Values at +25 °C, sea level
SMA Male to SMA Male Low Loss Test Cable Using PE-P300LL Coax, RoHS from Pasternack Enterprises has same day
shipment for domestic and International orders. Our RF, microwave and millimeter wave products maintain a 99% availability
and are part of the broadest selection in the industry.
Click the following link (or enter part number in “SEARCH” on website) to obtain additional part information including price,
inventory and certifications: SMA Male to SMA Male Low Loss Test Cable Using PE-P300LL Coax, RoHS PE333
URL: http://www.pasternack.com/sma-male-sma-male-pe-p300ll-cable-assembly-pe333-p.aspx
PE333 REV 1.0
4
PE333 CAD Drawing
SMA Male to SMA Male Low Loss Test Cable Using PE-P300LL Coax, RoHS
© 2014 Pasternack Enterprises All Rights Reserved
PE333 REV 1.0
5