Ray set Measurement - Seoul Semiconductor

Ray set Measurement
WICOP--A Package
WICOP
Central R & D Center
SUNGKI HWANG
2013.11.28
Copyright ⓒ Seoul Semiconductor Co., Ltd.
www.seoulsemicon.com
Legal Disclaimer
Information in this presentation is provided in connection with Seoul Semiconductor
products and/or business operation. While Seoul Semiconductor has made every attempt
to ensure that the information contained in this presentation has been obtained from
reliable sources, Seoul Semiconductor is not responsible for any errors or omissions, or
for the results obtained from the use of this information.
All information in this presentation is provided “as if” with no guarantee of completeness,
accuracy, timeliness or of the results obtained from the use of this information, and
without warranty of any kind, express or implied, including, but not limited to warranties of
merchantability, performance, and fitness for a particular purpose, or any warranty
otherwise arising out of any proposal, specification, or sample.
In no event will Seoul Semiconductor, its related corporations, or the employees thereof
be liable to you or anyone else for any decision made or action taken in reliance of the
information in this presentation or for any consequential, special or similar damages, even
if advised of the possibility of such damages.
Copyright ⓒ Seoul Semiconductor Co., Ltd.
www.seoulsemicon.com
1. Measurement Conditions
(1) Common Information
Package Name
WICOP-A
Operating Current / Voltage
99.3mA / 2.828V
Measuring Date
2013.11.28
Burn in Time
> 1 Hour
(2) Position and Orientation
The following views are showing the origin position of the ray data coordinate system referring to the measuring object.
The images are captured by the luminance measuring camera at the given angles of the goniometer coordinate system
(spherical coordinates)
y
z
x
View in Z axis(Theta = 0°, Phi = 90°)
Copyright ⓒ Seoul Semiconductor Co., Ltd.
x
View in Z axis(Theta = -90°, Phi = 90°)
Company Confidential
Goniometer coordinate system
www.seoulsemicon.com
2. Measurement results
(1) Measuring Parameter
(3) Conversion Format
Theta Range
-90° ~ 90°
Pos.
Conversion Format
Number of Rays
File Name
Theta Step
2.5°
1
Speos
5e6
WICOP-A_5M_Speos.ray
Phi Range
0° ~ 180°
2
-
-
-
Phi Step
2.5°
(2) Intensity Distribution
Polar plot
3D view
Spectrum
-
Viewing angle : 121deg
Copyright ⓒ Seoul Semiconductor Co., Ltd.
Company Confidential
www.seoulsemicon.com
3. Simulation results Using LightTools
(1) Schematics
z = 1mm
z= 0
(2) Illuminance distribution (z=0 & z=1mm)
z=0
z = 1mm
Copyright ⓒ Seoul Semiconductor Co., Ltd.
Company Confidential
www.seoulsemicon.com
THANK YOU!