ACT20M – a narrow 6 mm signal converter C

Signal converters in 6 mm width
ACT20M – Overview
ACT20M – a narrow 6 mm signal converter
The new dimension for converting and isolating –
housed in a 6 mm width
The new ACT20M range combines innovative technologies
with the highest levels of functionality in an electronics
housing measuring just 6 mm in width. Up to two channels
per module result in space savings in the electrical cabinet.
The high electrical isolation of 2.5 kV and an accuracy of
up to 0.05 % both help to ensure a high degree of process
reliability.
C
C.4
The product line consists of Input Loop Powered, Output
Loop Powered and Auxiliary Powered analog isolators and
converters, including a universal input converter.
The eight-connection housing allows additional functionality
such as 2 channel ILP, 2 channel OLP isolation and signal
splitting with input powering option. The configuration is
carried out via DIP switches or the FDT/ DTM software. The
ACT20M modules are supplied via direct wiring or a rail bus.
1327190000 – 2012/2013
Signal converters in 6 mm width
ACT20M – Overview
Saves space
6.1 mm
Up to two channels of 6 mm width
result in space savings in the electrical
cabinet.
C
High level of galvanic isolation
U, I,
R, T
U,I
PS
2.5 kV of electrical isolation
(300 V rated voltage) ensures excellent
process reliability.
Signal splitter
Installation is simple and quick
The power supply is simply snapped
onto the rail bus for fast and easy
installation. The supply can be through
any ACT20M module or a separate
power-feed unit.
+70 °C
to
–25 °C
Signal converter
Many different uses
The high measuring accuracy, the
wide temperature range and the
international approvals (cULus, ATEX
Zone 2, FM Div. 2, GL, DNV) enable
them to be used worldwide for many
applications.
\
Ex n
u;
Universal measuring transducer
Passive isolator
CH20M rail bus
Power-feed modules
1327190000 – 2012/2013
C.5
Signal converters in 6 mm width
ACT20M
Signal splitter
ACT20M-AI-2AO-S
• Isolating, converting and duplicating DC signals
• Configured using DIP switch
• Power supply via the rail bus
• 4-way isolation
C
I, U
IN
4
5
3
6
I, U
OUT 2
2
1
7
82
83
I, U
OUT 1
Supply
8
Supply
Technical data
Switch
Input
Input
Input current
Input voltage
Sensor supply
Input resistance, voltage
Voltage drop, current input
Output
Output current
Output voltage
load impedance current
load impedance voltage
General data
Configuration
Supply voltage
Ambient temperature
Accuracy
Temperature coefficient
Cut-off frequency (-3 dB)
Power consumption, typ.
Power consumption, max.
Insulation coordination
Insulation voltage
Rated voltage
Pollution severity
Surge voltage category
Approvals
0(4)...20 mA
0(2)…10 V, 0(1)…5 V
> 17 V DC at 20 mA
500 kΩ
< 1.5 V
0 … 20 mA
4 … 20 m
0 … 10 V
2 … 10 V
0…5V
1 …5 V
0 ... 20 mA loop
4 ... 20 mA loop
0(4)...20 mA
0(2)...10 V, 0(1)...5 V
< 300 Ω, per channel
≥ 10 kΩ
1
2
3
4
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
Switch
Output 1
DIP switch
24 V DC ± 30 %
-25 °C...+70 °C
< 0.05 % of measuring range
≤ 0.01 % / °C
100 Hz
400 mW
1.2 W
5
2.5 kVeff
300 Veff
2
II
CE; cULus; DETNORVER; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX
6
◼
◼
◼
◼
◼
◼
0 … 20 mA
4 … 20 m
0 … 10 V
2 … 10 V
0…5V
1 …5 V
7
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
Switch
Output 2
8
9
◼
◼
◼
◼
◼
◼
0 … 20 mA
4 … 20 m
0 … 10 V
2 … 10 V
0…5V
1 …5 V
10
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼ = on
◼ = off
ACT20M-AI-2AO-S
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
mm²
mm
Screw connection
2.5 / 0.5 / 2.5
114.3 / 6.1 / 112.5
Power
optionally over the DIN mounting rail CH20M
Screwsupply
connection
Ordering data
Screw connection
Type
ACT20M-AI-2AO-S
Qty.
1
Order No.
1176020000
2-wire
mA
passive
In
PLC
V, mA
passive
Out 2
4-wire
V, mA
active
In
PLC
V, mA
passive
Out 2
+
–
+
–
+
–
+
–
4
3
2
5
6
U, I
U, I
U, I
Power
1
8
4
3
2
1
7
5
U, I
6
U, I
U, I
Power
7
8
+
–
Out 1
+
Power
24 V
–
+
–
+
–
PLC
V, mA
passive
Out 1
PLC
V, mA
passive
Power
24 V
Note
Accessories
Note
C.6
DIN mounting rail, see Accessories
1327190000 – 2012/2013
Signal splitter
Signal converters in 6 mm width
ACT20M
ACT20M-CI-2CO-S
• Isolating, converting and duplicating DC signals
• Power supply via the rail bus
• 4-way isolation
I IN
I OUT 2
4
5
3
6
2
1
7
82
83
8
I OUT 1
C
Supply
Supply
Technical data
ACT20M-CI-2CO-S
Input
Input current
Voltage drop, current input
Output
Output current
load impedance current
load impedance voltage
General data
Configuration
Supply voltage
Ambient temperature
Accuracy
Temperature coefficient
Cut-off frequency (-3 dB)
Power consumption, typ.
Power consumption, max.
Insulation coordination
Insulation voltage
Rated voltage
Pollution severity
Surge voltage category
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
0(4)...20 mA
< 1.5 V
4-wire
mA
active
In
0(4)...20 mA
< 300 Ω, per channel
≥ 10 kΩ
PLC
mA
passive
Out 2
+
–
+
–
4
5
3
2
1
6
I
I
I
Power
7
8
+
–
+
–
Out 1
PLC
mA
passive
Power
24 V
none
24 V DC ± 30 %
-25 °C...+70 °C
< 0.05 % of measuring range
≤ 0.01 % / °C
100 Hz
400 mW
0.8 W
2.5 kVeff
300 Veff
2
II
CE; cULus; DETNORVER; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX
mm²
mm
Screw connection
2.5 / 0.5 / 2.5
114.3 / 6.1 / 112.5
Power
optionally over the DIN mounting rail CH20M
Screwsupply
connection
Ordering data
Screw connection
Type
ACT20M-CI-2CO-S
Qty.
1
Order No.
1175990000
Note
Accessories
Note
1327190000 – 2012/2013
DIN mounting rail, see Accessories
C.7
Signal converters in 6 mm width
ACT20M
Signal converter
ACT20M-AI-AO-S
• Isolating and converting DC signals
• Configured using DIP switch
• Power supply via the rail bus
• 3-way isolation
I, U
IN
4
5
3
6
2
C
7
1
82
83
I, U
OUT
Supply
8
Supply
Technical data
Switch
Input
Input
Input current
Input voltage
Sensor supply
Input resistance, voltage
Voltage drop, current input
Output
Output current
Output voltage
load impedance current
load impedance voltage
General data
Configuration
Supply voltage
Ambient temperature
Accuracy
Temperature coefficient
Cut-off frequency (-3 dB)
Power consumption, typ.
Power consumption, max.
Insulation coordination
Insulation voltage
Rated voltage
Pollution severity
Surge voltage category
Approvals
0(4)...20 mA
0(2)…10 V, 0(1)…5 V
> 17 V DC at 20 mA
>500 kΩ
<1,5 V
0 … 20 mA
4 … 20 m
0 … 10 V
2 … 10 V
0…5V
1 …5 V
0 ... 20 mA loop
4 ... 20 mA loop
0(4)...20 mA
0(2)...10 V, 0(1)...5 V
≤ 600 Ω
≥ 10 kΩ
DIP switch
24 V DC ± 30 %
-25 °C...+70 °C
< 0.05 % of measuring range
≤ 0.01 % / °C
100 Hz
400 mW
1.2 W
1
2
3
4
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
Switch
Output 1
2.5 kVeff
300 Veff
2
II
CE; cULus; DETNORVER; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX
5
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
ACT20M-AI-AO-S
2-wire
mA
passive
4-wire
V, mA
active
Screw connection
2.5 / 0.5 / 2.5
114.3 / 6.1 / 112.5
Power
optionally over the DIN mounting rail CH20M
Screwsupply
connection
◼
◼ = on
◼ = off
In
+
–
4
3
5
6
U, I
U, I
Power
1
mm²
mm
7
◼
◼
2
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
6
◼
0 … 20 mA
4 … 20 m
0 … 10 V
2 … 10 V
0…5V
1 …5 V
In
+
–
8
4
3
5
6
U, I
U, I
2
1
7
Power
7
8
+
–
Out 1
+
Power
24 V
–
+
–
+
–
PLC
V, mA
passive
Out 1
PLC
V, mA
passive
Power
24 V
Ordering data
Screw connection
Type
ACT20M-AI-AO-S
Qty.
1
Order No.
1176000000
Note
Accessories
Note
C.8
DIN mounting rail, see Accessories
1327190000 – 2012/2013
Signal converter
Signal converters in 6 mm width
ACT20M
ACT20M-AI-AO-E-S
• Isolating and converting DC signals
• Configured using DIP switch
• Power supply via the rail bus
• 3-way isolation
I, U
IN
4
5
3
6
2
7
1
82
83
I, U
OUT
C
Supply
8
Supply
Technical data
Switch
Input
Input
Input current
Input voltage
Input resistance, voltage
Voltage drop, current input
Output
Output current
Output voltage
load impedance current
load impedance voltage
General data
Configuration
Supply voltage
Ambient temperature
Accuracy
Temperature coefficient
Cut-off frequency (-3 dB)
Power consumption, typ.
Power consumption, max.
Insulation coordination
Insulation voltage
Rated voltage
Pollution severity
Surge voltage category
Approvals
0(4)...20 mA
0(2)…10 V, 0(1)…5 V
>500 kΩ
<1,5 V
1
0 … 20 mA
4 … 20 m
0 … 10 V
2 … 10 V
0…5V
1 …5 V
0 ... 20 mA loop
4 ... 20 mA loop
0(4)...20 mA
0(2)...10 V, 0(1)...5 V
≤ 600 Ω
≥ 10 kΩ
DIP switch
24 V DC ± 30 %
0 °C...+70 °C
< 0.2 % of measuring range
≤ 0.015 % / °C
100 Hz
400 mW
1.2 W
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
5
6
◼
◼
7
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼
◼ = on
◼ = off
ACT20M-AI-AO-E-S
In
+
–
4
3
5
6
U, I
U, I
2
1
mm²
mm
4
◼
Switch
0 … 20 mA
4 … 20 m
0 … 10 V
2 … 10 V
0…5V
1 …5 V
2.5 kVeff
300 Veff
2
II
CE; cULus; DETNORVER; GL; GOSTME25
3
◼
Output 1
4-wire
V, mA
active
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
2
◼
Power
7
8
+
–
+
–
Out 1
PLC
V, mA
passive
Power
24 V
Screw connection
2.5 / 0.5 / 2.5
114.3 / 6.1 / 112.5
Power
optionally over the DIN mounting rail CH20M
Screwsupply
connection
Ordering data
Screw connection
Type
ACT20M-AI-AO-E-S
Qty.
1
Order No.
1176010000
Note
Accessories
Note
1327190000 – 2012/2013
DIN mounting rail, see Accessories
C.9
Signal converters in 6 mm width
ACT20M
Signal isolator
ACT20M-CI-CO-S
• Isolating DC signals
• Power supply via the rail bus
• 3-way isolation
I IN
4
5
3
2
C
I OUT
6
7
1
82
83
8
Supply
Supply
Technical data
ACT20M-CI-CO-S
Input
Input current
Voltage drop, current input
Output
Output current
load impedance current
General data
Configuration
Supply voltage
Ambient temperature
Accuracy
Temperature coefficient
0(4)...20 mA
< 1.5 V
In
+
–
4
3
5
6
I
I
2
0(4)...20 mA
≤ 600 Ω
1
Power
7
8
+
–
+
–
Out 1
PLC
mA
passive
Power
24 V
none
24 V DC ± 30 %
-25 °C...+70 °C
< 0.05 % of measuring range
≤ 0.01 % / °C
100 Hz
400 mW
0.8
Cut-off frequency (-3 dB)
Power consumption, typ.
Power consumption, max.
Insulation coordination
Insulation voltage
Rated voltage
Pollution severity
Surge voltage category
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
4-wire
mA
active
2.5 kVeff
300 Veff
2
II
CE; cULus; DETNORVER; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX;
ROHS
mm²
mm
Screw connection
2.5 / 0.5 / 2.5
114.3 / 6.1 / 112.5
Power
optionally over the DIN mounting rail CH20M
Screwsupply
connection
Ordering data
Screw connection
Type
ACT20M-CI-CO-S
Qty.
1
Order No.
1175980000
Note
Accessories
Note
C.10
DIN mounting rail, see Accessories
1327190000 – 2012/2013
Universal measuring transducer
Signal converters in 6 mm width
ACT20M
ACT20M-UI-AO-S
• Isolating and converting of temperature signals and DC
signals
• Configuration using FDT/DTM software
• Power supply via the rail bus
• 3-way isolation
4
3
I, U, R
IN
2
5
I, U
6
OUT
7
1
82
83
C
Supply
8
Supply
Technical data
ACT20M-UI-AO-S
Input
Sensor
Thermocouples: B, E, J, K, L, LR, N, R, N, R, S, T, U, W3, W5, RTD:
PT100, PT1000, Ni100, Ni1000, 2-/3-/4-wire
10 Ω…10 kΩ
10 Ω…10 kΩ
0(4)...20 mA
0(2)…10 V, 0(1)…5 V
> 10 MΩ
<3V
> 15 V DC at 20 mA
Potentiometer
Resistance
Input current
Input voltage
Input resistance, voltage
Voltage drop, current input
Sensor supply
Output
Output current
Output voltage
load impedance current
load impedance voltage
General data
Configuration
Supply voltage
Ambient temperature
Accuracy
Temperature coefficient
Power consumption, typ.
Power consumption, max.
Insulation coordination
Insulation voltage
Rated voltage
Pollution severity
Surge voltage category
Approvals
4-wire
mA
active
In
+
–
4
3
5
U, I, ϧ
6
U, I
2
Power
1
2-wire
mA
passive
In
+
–
0(4)...20 mA
0(2)...10 V, 0(1)...5 V
≤ 600 Ω
≥ 10 kΩ
5
U, I, ϧ
6
U, I
2
Power
1
With FDT/DTM software
24 V DC ± 30 %
-25 °C...+70 °C
< 0.1 % of measuring range
≤ 0.01 % / °C
400 mW
1.2 W
8
4
3
7
7
8
+
–
Out 1
+
Power
24 V
–
+
–
PLC
mA
passive
Out 1
+
PLC
mA
passive
Power
24 V
–
ACT20M-UI-AO-S
+
4-wire
V
active
4
3
In
–
5
U, I, ϧ
U, I
2
Power
1
2.5 kVeff
300 Veff
2
II
cULus; DETNORVER; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX
6
8
4
3
TC
In
+
–
7
5
U, I, ϧ
6
U, I
2
Power
1
7
8
+
–
Out 1
+
Power
24 V
–
+
–
PLC
mA
passive
Out 1
+
PLC
mA
passive
Power
24 V
–
ACT20M-UI-AO-S
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
mm²
mm
Screw connection
2.5 / 0.5 / 2.5
114.3 / 6.1 / 112.5
Power
optionally over the DIN mounting rail CH20M
Screwsupply
connection
RTD
Sense +
4
R+
3
R–
2
Sense –
1
5
U, I, ϧ
6
U, I
Power
7
8
+
–
+
–
Out 1
PLC
mA
passive
Power
24 V
Ordering data
Screw connection
Type
ACT20M-UI-AO-S
Qty.
1
Order No.
1176030000
Note
Accessories
Note
1327190000 – 2012/2013
CBX200 USB configuration adapter - 8978580000
DIN mounting rail, see Accessories
C.11
Signal converters in 6 mm width
ACT20M
Passive isolator
ACT20M-CI-CO-ILP-S
• Isolation of DC signals without a separate power supply
• Supplied with power from the input measuring circuit
• Available as either single-channel or double-channel
version
• 2-way isolation
I IN 1
C
I IN 2
4
5
3
6
2
7
1
8
I OUT 1
I OUT 2
Technical data
ACT20M-CI-CO-ILP-S
Input
Voltage drop, current input
Input current
Output
Output current
load impedance current
General data
Configuration
Ambient temperature
Accuracy
Temperature coefficient
Cut-off frequency (-3 dB)
Power consumption, max.
Insulation coordination
Insulation voltage
Rated voltage
Pollution severity
Surge voltage category
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
1.25 V + 0.015 Vout @25°C
0(4)...20 mA
4-wire
mA
active
In
+
–
5
3
6
I
2
0(4)...20 mA
≤ 600 Ω
+
–
Out
PLC
mA
passive
Out 1
PLC
mA
passive
Out 2
PLC
mA
passive
7
I
1
none
-25 °C...+70 °C
< 0.1 % of measuring range
≤ 0.01 % / °C
100 Hz
30 mW per channel
8
ACT20M-2CI-2CO-ILP-S
2.5 kVeff
300 Veff
2
II
DETNORVER; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX
mm²
mm
4
4-wire
mA
active
In 1
4-wire
mA
active
In 2
+
–
+
–
4
3
2
1
5
I
I
6
7
I
I
8
+
–
+
–
1-channel version
2.5 / 0.5 / 2.5
114.3 / 6.1 / 112.5
Power supply optionally over the DIN mounting rail CH20M
Ordering data
1-channel version
2-channel version
Type
ACT20M-CI-CO-ILP-S
ACT20M-2CI-2CO-ILP-S
Qty.
1
1
Order No.
1176070000
1176080000
Note
Accessories
Note
C.12
DIN mounting rail, see Accessories
1327190000 – 2012/2013
Passive isolator
Signal converters in 6 mm width
ACT20M
ACT20M-CI-CO-OLP-S
• Isolation of DC signals without a separate power supply
• Supplied with power from the output measuring circuit
• Available as either single-channel or double-channel
version
• 2-way isolation
I IN 1
I IN 2
4
5
3
6
2
7
1
8
I OUT 1
C
I OUT 2
Technical data
ACT20M-CI-CO-OLP-S
Input
Voltage drop, current input
Input current
Output
Output current
Supply voltage
General data
Configuration
Ambient temperature
Accuracy
Temperature coefficient
Typical 2.5 V
4...20 mA
In
+
–
4
5
3
6
I
2
4...20 mA
6…35V
+
–
Out
PLC
mA
active
Out 1
PLC
mA
active
Out 2
PLC
mA
active
7
I
1
none
-25 °C...+70 °C
< 0.05 % of measuring range
≤± 0.07 µA x (Δ °C x V supply) @ Tamb < 25 °C
, ≤±0.02 µA x (Δ °C x V supply) @ Tamb > 25 °C
100 Hz
30 mW per channel
Cut-off frequency (-3 dB)
Power consumption, max.
Insulation coordination
Insulation voltage
Rated voltage
Pollution severity
Surge voltage category
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
2-wire
mA
passive
8
ACT20M-2CI-2CO-OLP-S
2-wire
mA
passive
In 1
2-wire
mA
passive
In 2
+
–
+
–
4
3
2
1
5
I
I
6
7
I
I
8
+
–
+
–
2.5 kVeff
300 Veff
2
II
DETNORVER; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX
mm²
mm
1-channel version
2.5 / 0.5 / 2.5
114.3 / 6.1 / 112.5
Power supply optionally over the DIN mounting rail CH20M
Ordering data
1-channel version
2-channel version
Type
ACT20M-CI-CO-OLP-S
ACT20M-2CI-2CO-OLP-S
Qty.
1
1
Order No.
1176040000
1176050000
Note
Accessories
Note
1327190000 – 2012/2013
DIN mounting rail, see Accessories
C.13
ACT20M-BAI-AO-S
Signal converter and splitter
•Bipolar DC signal isolation, conversion and
splitting (doubling)
•Configured using DIP switch
•Power supply via the rail bus
•4-way isolation
Machinery
Technical data
ACT20M signal converters | Bipolar signal converter
± I, ± V
IN
ACT20M-BAI-2AO-S
4
5
3
6
2
7
1
8
82 83
I, V
± I, ± V
OUT 1
IN
Supply
OUT 2
4
5
3
6
2
7
1
I, V
82 83
8
I, V
OUT 1
Supply
Supply
Supply
Transportation
Device
Manufacturers
Energy
Process
Technical data
Input
Input current
Input voltage
Output
Output current
Output voltage
Load impedance current
Load impedance voltage
General data
Supply voltage
Ambient temperature (Operation)
Storage temperature
Accuracy
Temperature coefficient
Cut-off frequency
Insulation coordination
Insulation voltage
Rated voltage
Pollution degree
Overvoltage protection
Approvals
Dimensions
Length x width x height
Clamping range (nominal / min. / max.)
Note
mm
mm2
Ordering data
-10…+10 mA / -20…+20 mA
-10…+10 V / -5…+5 V
-10…+10 mA / -20…+20 mA
-10…+10 V / -5…+5 V
0/4…20 mA
0…5 V / 1…5 V / 0…10 V / 2…10 V
< 600 Ω
> 10 k Ω
2x 0/4…20 mA or 1x ±20 mA, ±10 mA
2x 0…5 V / 1…5 V / 0…10 V / 2…10 V
2x 300 Ω
> 10 k Ω
24 V DC ± 30 %
-25 °C…+70 °C
-40 °C…+85 °C
< 0.05 % of measuring range
< 0.01 % /K
100 Hz 10 Hz
24 V DC ± 30 %
-25 °C…+70 °C
-40 °C…+85 °C
< 0.05 % of measuring range
< 0.01 % /K
100 Hz 10 Hz
2.5 kV
300 V
2
II
2.5 kV
300 V
2
II
cULus 61010-1; FMEX; GL; DNV; IECEX; KEMAATEX; ROHS
cULus 61010-1; FMEX; GL; DNV; IECEX; KEMAATEX; ROHS
114.3 x 6.1 x 112.5
2.5 / 0.5 / 2.5
114.3 x 6.1 x 112.5
2.5 / 0.5 / 2.5
Type
ACT20M-BAI-AO-S
Qty.
1
Order No.
1375450000
Type
ACT20M-BAI-2AO-S
Qty.
1
Order No.
1375470000
Type
MF 5/7.5 MC NEUTRAL
Qty.
Order No.
1877680000
Type
MF 5/7.5 MC NEUTRAL
Qty.
Order No.
1877680000
Note
Accessories
Markers
Note
T.64
DIN rail bus, refer to accessories page
DIN rail bus, refer to accessories page
1435580000 – 2013
Signal converters in 6 mm width
CH20M rail bus
CH20M rail bus
Quick and safe power supply through the DIN rail.
C
This customer-friendly infrastructure solution brings power,
signals and data to the rail in a quick and reliable manner.
The rail bus can replace the tedious individual wiring process
with a flexible and uninterrupted system solution. As a result,
the customer saves time and cost-especially if any module
changes are needed later, as other adjacent modules are
not disturbed. The uninterrupted system bus is securely
integrated within the 35 mm standard mounting rail.
Whether 7.5 mm or 15 mm high, the custom-fit rail profiles
are easy to install on all TS-35 standard rails in accordance
with DIN EN 60715.
The supply of 24 V DC to the power rail can be from any
one of the auxiliary powered ACT20M modules, when that
module is itself externally supplied. This allows the rail to
power up to 8 other modules (approximately 400 mA). For
powering additional ACT20Ms, a separate Feed-In module
can be used.
The ACT20-Feed-In-Basic provides a simple and compact
(6 mm width) power supply interface to the rail, for
supplying up to 2.5 A (up to 50 x ACT20M modules).
The resistant gold-plated contacts ensure a permanent and
reliable contact. The ACT20M modules are simply snapped
onto the mounting rail and are automatically in contact with
the DIN rail bus.
The ACT20-Feed-In-Pro is a more powerful 22.5 mm wide
solution. This takes 2 external 24 V DC inputs, and via
internal diodes provides a redundant supply to the rail, and
an alarm output in the case of input failure.
C.14
1327190000 – 2012/2013
Signal converters in 6 mm width
CH20M rail bus
Rail bus accessories
CH20M BUS-PROFIL TS35x7.5/1000
CH20M BUS-PROFIL TS35x15/1000
CH20M BUS 4.50/05 AU/1000
Support section for bus circuit board
Support section for bus circuit board
Bus PCB
• Support section for TS35 x 7.5
• Length: 250, 500 or 750 mm
• Support section for TS35 x 15
• Length: 250, 500 or 750 mm
• Bus circuit board for use on TS35 x 7.5
and TS 35 x 15
• Length: 250, 500 or 750 mm
• Five conductor paths, gold-plated
• Electrical rating: 63 V AC, 5 A/conductor path
Ordering data
Type
CH20M BUS-PROFIL TS35x7.5/250
CH20M BUS-PROFIL TS35x7.5/500
CH20M BUS-PROFIL TS35x7.5/750
Qty.
10
10
5
Order No.
1248150000
1248160000
1248170000
Ordering data
Type
CH20M BUS-PROFIL TS35x15/250
CH20M BUS-PROFIL TS35x15/500
CH20M BUS-PROFIL TS35x15/750
Qty.
5
5
5
Order No.
1248180000
1248190000
1248210000
Ordering data
Type
CH20M BUS 4.50/05 AU/250
CH20M BUS 4.50/05 AU/500
CH20M BUS 4.50/05 AU/750
Qty.
10
10
5
CH20M BUS-ADP TS35/1000
CH20M BUS-AP LI TS35x7.5 & 15
CH20M BUS-AP RE TS35x7.5 & 15
Cover plate
End plate
End plate
• Cover plate for DIN rail bus
• Length: 250, 500 or 750 mm
• End plate for DIN rail bus
• Fits on TS35 x 7.5 and TS35 x 15
• left
• End plate for DIN rail bus
• Fits on TS35 x 7.5 and TS35 x 15
• right
Ordering data
Type
CH20M BUS-ADP TS35/250
CH20M BUS-ADP TS35/500
CH20M BUS-ADP TS35/750
Qty.
10
10
5
Order No.
1248250000
1248260000
1248270000
Ordering data
Type
CH20M BUS-AP LI TS35x7.5 & 15
Qty.
Order No.
50 1193160000
SET CH20M BUS 250MM TS 35X15
SET CH20M BUS 250MM TS 35X7.5
Set
Set
• SET consists of one each of
CH20M BUS 4.50/05 AU/250
CH20M BUS-ADP TS 35/250
CH20M BUS-AP LI TS 35X7.5 & 15
CH20M BUS-AP RE TS 35X7.5 & 15
CH20M BUS-PROFIL TS 35X15/250
• SET consists of one each of
CH20M BUS 4.50/05 AU/250
CH20M BUS-ADP TS 35/250
CH20M BUS-AP LI TS 35X7.5 & 15
CH20M BUS-AP RE TS 35X7.5 & 15
CH20M BUS-PROFIL TS 35X7.5/250
Ordering data
Type
SET CH20M BUS 250MM TS 35X15
1327190000 – 2012/2013
Qty.
1
Order No.
1335150000
Ordering data
Type
SET CH20M BUS 250MM TS 35X7.5
Qty.
1
Ordering data
Type
CH20M BUS-AP RE TS35x7.5 & 15
Qty.
50
C
Order No.
1248220000
1248230000
1248240000
Order No.
1193170000
Order No.
1335140000
C.15
Signal converters in 6 mm width
CH20M rail bus
Power-feed module for the CH20M DIN rail bus
4 A supply with backup supply and
error analysis
C
The power-feed unit ACT20-FEED-IN-PRO-S supplies
the devices on the CH20M DIN rail bus with 24 V DC.
At the same time, the FEED-IN device reads the group error
contact – optionally provided by the installed devices – from
the CH20M rail bus and sends a message through the
status relay to the external controller. Optionally, two power
supplies can be connected as a primary and back-up, to
create a redundant 24 V DC source. An installation in
Zone 2 / Division 2 is also possible. Three LEDs show the
status of the power supply and the error status.
The FEED-IN-PRO can supply a maximum of 4 A to feed
up to 120 devices mounted on a CH20M rail bus. Quick
identification of errors on the DIN rail bus is through the
internal status relay. The FEED-IN-PRO device immediately
recognises and displays when a power supply has failed.
The supply is then switched automatically to the redundant
power supply.
C.16
Weidmüller offers a compact and narrow 6 mm
feed-in module as an alternative. This feeds the 24 V DC
from it‘s field terminals directly to the to the DIN rail bus. Up
to 80 modules can be fed with a maximum available current
of 2.5 A.
1327190000 – 2012/2013
ACT20 power-feed module
ACT20-Feed-In-PRO-S
Signal converters in 6 mm width
ACT20 power-feed unit
ACT20-Feed-In-BASIC-S
• Distributes the supply onto the busbar
• Compatible with Weidmüller CH20 DIN rail bus
• Optional connection for backup supply
• Approved for use in Ex-Zone 2 /Div. 2
• Monitoring of the supply voltage
• Alarm alerts via the status relay
Alarm
Power supply, 0 V 51
44 NC
Power supply, +24 V 52
Power supply, +24 V
43 Status relay, N.C.
Backup, +24 V 53
42 Status relay, shared
Backup, 0 V 54
41 Status relay, N.O.
C
NC
0V
NC
+24 V
81
NC
82
Status
83
0V
84
+24 V
NC
NC
85
Power supply, 0 V
Technical data
Input
Supply voltage
Input current
Trigger level for the power supply
Output, power supply
Output voltage
Output power
Output current
Output, status relay in safe zone
Max. switching voltage, AC / Max. switching voltage, DC
Continuous current
AC power, max.
General data
Degree of efficiency
Ambient temperature
Power consumption
Protection degree
Weight
Humidity
Approvals
Dimensions
Clamping range (nominal / min. / max.)
Length x width x height
Note
mm²
mm
21.6...26.4 V DC
Max. 4 A
21.6...26.4 V DC
Fault < 21 V DC
21.6...26.4 V DC
0.5...2.5 A DC
Input voltage -0.5 V DC / 4 A
96 W
Max. 4 A
Corresponds to the input voltage
250 V / 30 V
2 A AC / DC
500 VA / 60 W
250 V / 30 V
0,976
-20 °C...+60 °C
<2W
IP 20
140
95 %, no condensation
DEKRAATEX; FMEX; GOSTME25; IECEXDEK
100 %
-25 °C...+70 °C
Screw connection
2.5 / 0.5 / 2.5
119.2 / 22.5 / 113.6
Screw connection
Equivalent to input current
IP 20
70
95 %, no condensation
cULus; DETNORVER; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX
114.3 / 6.1 / 112.5
Ordering data
Screw connection
Type
ACT20-FEED-IN-PRO-S
Qty.
1
Order No.
8965500000
Type
ACT20-FEED-IN-BASIC-S
Qty.
1
Order No.
1282490000
Note
Accessories
Note
1327190000 – 2012/2013
DIN mounting rail, see Accessories
DIN mounting rail, see Accessories
C.17