ES51929 6000 Counts Smart DMM Features Application 6000 counts LCD display Smart digital multi-meter 3V DC power supply Smart clamp meter Conversion rate: 3 times/s (voltage mode) Full automatic measurement: General description *Voltage/Current: AC/DC auto scanning & auto range: 6.000V~1000V ES51929 is an integrated ADC with 6000 counts *Resistance/Diode/Capacitance(RDC scan) LCD display driver. It could support fully (Taiwan patent no.: 326361) automatic DMM function measurement. In Auto scanning & auto range: voltage or current mode, the AC or DC signals Resistance: 600.0Ω~6.000MΩ auto scanning. In R/D/C (passive component) Capacitance: 6.000nF~600.0uF mode, resistance (including continuity), (Taiwan patent no.: 323347,453443) capacitance or diode measurements are allowed Push functions by fully automatic detection. A single key and Function selection by single key simple switch could select all measurements. Range change function Expensive and bulky mechanical range switches Hold function are not required. A non-contact electric field MAX/MIN function detector (EF mode) is built-in for ac voltage VAHZ function measurement DCA Zero function Clamp-on DCA Zero mode. Other features Back light function including range control, data hold, max/min hold, Support non-contact voltage detection VAHz and back light function are available. For High voltage (> 30V) indication of LCD power saving, an auto power off & re-power on display for voltage measurement scheme are built-in. A sleep output is the Built-in HCF(high crest factor detection) indication of entering auto power off mode. also. The ES51929 support function in AC mode (Taiwan patent no.: 234661) OL level selection (600V/1000V/1500V) Band-gap reference voltage output Auto power off (3min. or 10min.) & re-power on Sleep output indication On-chip buzzer driver Low battery detection Ver 1.2 1 12/09/07 ES51929 6000 Counts Smart DMM SEG11 SEG10 NC NCV_EN SEG09 SEG08 SEG07 SEG06 SEG05 SEG04 SEG03 SEG02 SEG01 OSC2 OSC1 BKSEL CESEL C+ CVVV+ V+ DGND AGND ZERO nF_OPT NC NC NC ACEN BUZOUT APOSEL BUZIN SLEEP R1K R9K CA+ CANC VR1 VAVA+ ADP SGND VR VRH PWRSEL OHMC1 OHMC2 ES51929 50 49 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 AGND LBAT CREF+ CREFCINT CAZ BUFF RAZ IVSH IVSL OVX OVH OVSG OR1 VR5 VR4 VR3 VR2 TEST5 ACVL ACVH ADI ADO OHMC4 OHMC3 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 SEG12 SEG13 SEG14 SEG15 CLAMP VON AON FA FUA FC3 FC2 FC1 HOLD SEL VAHz RANGE MAX/MIN BKLIT EFEN BP1 BP2 BP3 BP4 ANNUNC BKOUT 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 Pin Assignment Pin Description Pin No Symbol Type 3 4 5 6 7 8 CREF+ CREFCINT CAZ BUFF RAZ I/O I/O O I O O 9 10 11 IVSH IVSL OVX I I I 1 2 Ver 1.2 AGND LBAT P I Description Analog ground. Low battery configuration. If 3V battery is used, connect it to DGND. The default low-battery threshold voltage is –2.3V. If 9V battery is used, the low battery enunciator is displayed when the voltage of this pin is less than VRH (-1.2V) Positive connection for reference capacitor. Negative connection for reference capacitor. Integrator output. Connect to integral capacitor Auto-zero capacitor connection. Buffer output pin. Connect to integral resistor Buffer output pin in high-speed mode. Connect to high-speed integral resistor. High current measurement input. Low current measurement input Input high voltage for resistance/capacitor measurement 2 12/09/07 ES51929 6000 Counts Smart DMM 12 13 14 15 16 17 18 19 20 OVH OVSG OR1 VR5 VR4 VR3 VR2 TEST5 ACVL I I O O O O O I/O I 21 ACVH I 22 23 24 25 26 27 28 29 30 31 32 33 ADI ADO OHMC4 OHMC3 OHMC2 OHMC1 PWRSEL VRH VR SGND ADP VA+ I O O O O O I O I I I I 34 VA- I 35 36 37 38 39 40 41 42 43 44 45 46 – 48 49 50 51 VR1 NC CACA+ R9K R1K SLEEP BUZIN APOSEL BUZOUT ACEN NC nF_OPT ZERO BKOUT I I/O I/O O O O I I O O I I O 52 ANNUNC O 53 54 55 56 57 58 59 60 BP4 BP3 BP2 BP1 EFEN BKLIT MAX/MIN RANGE O O O O I I I I Ver 1.2 Output connection for resistance/capacitor measurement Sense low voltage for resistance measurement Reference resistor connection for 600.0Ω range Voltage measurement ÷10000 attenuated (1000V) Voltage measurement ÷1000 attenuated (600.0V) Voltage measurement ÷100 attenuated (60.00V) Voltage measurement ÷10 attenuated (6.000V) Test pin DC signal low input in ACV/ACA mode. Connect to negative output of external AC to DC converter. DC signal high input in ACV/ACA mode. Connect to positive output of external AC to DC converter. Negative input of internal AC to DC OP Amp. Output of internal AC to DC OP Amp. Filter capacitor connection for resistance mode Filter capacitor connection for resistance mode Filter capacitor connection for resistance mode Filter capacitor connection for resistance mode Pulled to V- to disable the power function of SEL key Output of band-gap voltage reference. Typically –1.2V Reference input voltage connection. Typically –400mV Signal Ground. Measurement input in ADP mode For ADP mode. De-integrating voltage positive input. The input should be higher than VA-. For ADP mode. De-integrating voltage negative input. The input should b lower than VA+. Measurement input. Not connected Negative auto-zero capacitor connection for capacitor measurement Positive auto-zero capacitor connection for capacitor measurement Connect to a precise 9KΩ resister for capacitor measurement. Connect to a precise 1KΩ resister for capacitor measurement. Sleep mode indicator, asserts low in SLEEP mode. Normal V+ output. Pull to V- to enable the BUZOUT. Auto power off idle time selection. Outputs a 2KHz audio frequency signal for driving piezoelectric buzzer Output to V- when AC mode inactive and output to V+ in AC mode. Not connected Pulled to V- to enable the residual capacitance reduction mode Pulse to V- to enable DCA ZERO function. If BKLIT function is enabled, this pin will change from –3V to +3V for 60 sec, once press BKLIT pin again within 60 sec, this pin will change back to –3V. Square wave output at the backplane frequency, synchronized to BP1. ANNUNC can be used to control display annunciator. Connect a LCD segment to ANNUNC to turn it on; connect an LCD segment to its back plane to turn it off. LCD backplane 4 LCD backplane 3 LCD backplane 2 LCD backplane 1 Pull-low to enable non-contact AC voltage detection Back light function. Pulse low to set BKOUT pin output. Pulse to V- to enable MAX/MIN function. Pulse to V- to enable manual mode and manual range selection. 3 12/09/07 ES51929 6000 Counts Smart DMM 61 62 63 64 65 66 67 68 69 70 71 72 – 77 78 79 80 – 88 89 90 VAHz SEL HOLD FC1 FC2 FC3 FUA FA AON VON CLAMP SEG15 – 10 NC NCV_EN SEG09 - 01 OSC2 OSC1 I I I I I I I I I I I O I O I O 91 BKSEL I 92 93 94 95 96 97 98 99 100 CESEL C+ CVVV+ V+ DGND AGND I O O P P P/O P/O G G Pulse to V- to enable VAHz mode. Pulse to V- to select target measurement Pulse to V- to enable HOLD function. Switch 1 for function selection. Switch 2 for function selection. Switch 3 for function selection. Switch 1 for current measurement selection. Switch 2 for current measurement selection. Pull to high to sense current measurement priority in auto scan mode Pull to high to sense voltage measurement priority in auto scan mode Switch for clamp meter application function LCD segment line 10 – 15 Not connected Individual EF function selection LCD segment line 01 – 09 Crystal oscillator input connection Crystal oscillator output connection When pulled to V-, an auto back light configuration is allowed. Configure a low level applied to BKLIT larger than 1 second, the BKOUT will be active. If BKLIT is back to high level, the BKOUT would be inactive. OL selection feature control pin. Positive capacitor connection for on-chip DC-DC converter. Negative capacitor connection for on-chip DC-DC converter. Negative supply voltage. Connecting to battery negative terminal. Negative supply voltage. Connecting to battery negative terminal. Output of on-chip DC-DC converter. Output of on-chip DC-DC converter. Digital ground. Analog ground. Absolute Maximum Ratings Characteristic Supply Voltage (V- to AGND) Analog Input Voltage V+ AGND/DGND Digital Input Power Dissipation. Flat Package Operating Temperature Storage Temperature Ver 1.2 Rating -4V V- -0.6 to V+ +0.6 V+ ≥ (AGND/DGND+0.5V) AGND/DGND ≥ (V- -0.5V) V- -0.6 to DGND +0.6 500mW 0℃ to 70℃ -25℃ to 125℃ 4 12/09/07 ES51929 6000 Counts Smart DMM Electrical Characteristics TA=25℃, V- = -3V Parameter Power supply Operating supply current In Scan AC/DC mode Voltage roll-over error Voltage nonlinearity Input Leakage Low battery flag voltage Zero input reading Peak to peak backplane drive voltage Counter time base period Reference voltage and open circuit voltage for 600Ω measurement Open circuit voltage for Ω measurement (except 600Ω) Internal pull-high to 0V current AC frequency response at 6.000V Range AC input response for scan mode AC/DC voltage scan mode sensitivity@1kHz AC/DC current scan mode sensitivity@1kHz RDC scan mode RES sensitivity Symbol Test Condition VIDD Normal operation ISS In sleep mode REV 10MΩ input resistor Min. -3.5 — — — Typ. -3.0 2.5 0.6 — Max -2.5 — 2.5 ±0.1 Units V mA µA %F.S1 Best case straight NLV line — — ±0.1 %F.S -10 -2.4 -000 1 -2.3 000 10 -2.2 +000 PA V counts 3.0 3.15 3.3 V — 1 — sec -1.33 -1.23 -1.13 V -0.86 -0.78 -0.70 V — 1.2 — µA V- to AGND 10MΩ input resistor -3.5V≤ V ≤-2.2V VREF fOSC = 4MHZ 100KΩ resistor between VRH and AGND Ω and Continuity Mode Between V- pin and HOLD, RANGE, SEL,FC1-3,FUA, FA, VON, AON, CLAMP, BKLIT, MAXMIN ±1% ±5% VR1(10MΩ input impedance) ADP, IVSL and IVSH Parasitic capacitance allowed in 6.000MΩ range Forward voltage RDC scan mode DIODE sensitivity RDC scan mode CAP sensitivity Reference voltage temperature 100KΩ resister coefficient VRH TCRF Between 0℃<TA<70℃ Capacitance measurement accuracy 6nF – 6.0µF 60µF ~ 60mF — — 10 40-400 — 400-2000 — — 50000 HZ Hz 300 450 600 mV 8 10 12 mV — — 200 pF 400 0.8 — — V pF — 50 — ppm/℃ -1.5 -5 -2.0 — — — 1.5 5 2.0 %F.S counts %F.S -5 — 5 counts Note: 1.Full Scale Ver 1.2 5 12/09/07 ES51929 6000 Counts Smart DMM Functional Description 1. Operation Modes 1.1 Voltage Measurement A re-configurable voltage divider automatically provides a suitable range in voltage measurement mode. The following table summarizes the full-scale ranges in each configuration. Configuration VR1 VR2 VR3 VR4 VR5 Full Scale Range 600.0mV* 6.000V** 60.00V 600.0V 1000V*** Divider Ratio 1 1/10 1/100 1/1000 1/10000 Resister Connection VR1 (10MΩ) VR2 (1.111MΩ) VR3 (101KΩ) VR4 (10KΩ) VR5 (1KΩ) Note: * Exists in manual mode only by RANGE key control **This range is the default range for auto range & auto scan mode *** Depends on CESEL selection 1.1.1 OL selection ES51929 has a OL display selection feature archived by configuring a CESEL pin. If pin CESEL is connected to V-, ES51929 will have a 600.0V overflow level in DC and AC 600.0V ranges. And the 1000V range will not occur anymore. If pin CESEL is connected to DGND, the ES51929 will have a 1010V overflow level in DCV mode and have a 1010V overflow level in ACV mode also. When CE is floating, a 1500V overflow level in DCV mode but ACV is still 1010V overflow level. The meter will Show OL when the measuring signal reaches the overflow level with beeper warning. The configuration of CESEL is listed below. CESEL VDGND Floating Ver 1.2 DCV 600.0V 1010V 1500V 6 ACV 600.0V 1010V 1010V 12/09/07 ES51929 6000 Counts Smart DMM 1.1.2 HCF detection ES51929 provides detection of high-crest-factor (HCF) signal in ACV auto range mode. ES51929 senses the signal and determines it as HCF if the Vpp is large enough. Once the signal is determined as HCF, ES51929 will jump up one measuring range regardless of current measurement value. It takes 60ms to jump one range up. The jumping up process will continue until the maximum range is reached. With HCF detection, a more accurate result could be obtained. For example, when a input signal with Vpp=350V, Vrms=70V(CF=5) was applied, traditional DMM might stay at 60V range but shows counts with the amount of error up to 10% or even bigger. The error rises from limited input/output swing at internal ADC. With HCF detection, DMM will stay at 600V range and exhibits more accurate results. 1.1.3 EF mode ES51929 supports a non-contact ac voltage measurement, which is called electric field measurement also. The EF mode is selected by SEL key when EF_EN is active or set control mode individually. The ADC input is configured from ADP pin vs. SGND. When no or less electric field is detected, the LCD shows “EF”. If the detector senses electric field, the strength will be showed on LCD by “-“ not digits type. Level 1(weak) is “-“ and the level 4(strong) is “----“. Additional beeper will be output from BUZOUT pin. The buzzer frequency depends on the strength of electric field also. The Faster beeper means the stronger electric field (ac voltage) is sensed. Ver 1.2 7 12/09/07 ES51929 6000 Counts Smart DMM 1.2 Current Measurement 1.2.1 For multi-meter application ES51929 has 2 automatic and 1 manual current measurement modes for multi-meter. The following table summarizes the full-scale range of each mode. When ES51929 operates in the current measurement modes for multi-meter, it takes high input from pin IVSH or IVSL, low input from pin SGND and reference voltage from pin VR. Mode Automatic1 Automatic2 Manual Full Scale 600.0µA / 6000µA 60.00mA / 600.0mA 60.00A Input Terminal IVSL/IVSH V.S. SGND IVSL/IVSH V.S. SGND IVSH V.S. SGND Full scale 300.0mV 300.0mV 300.0mV 1.2.2 For clamp meter application ES51929 has 2 automatic and 4 manual current measurement modes for Clamp meter. The following table summarizes the full-scale range of each mode. When ES51929 operate in the automatic mode1&2, it takes high input from IVSH/IVSL (higher range/lower range), low input from SGND and reference voltage from VR. When ES51929 operate in the manual mode1~4, it takes high input from ADP, low input from SGND and reference voltage from VA+ & VA-. Mode Automatic1 Automatic2 Manual1 Manual2 Manual3 Manual4 Ver 1.2 Full Scale 600.0A / 6000A 60.00A / 600.0A 6.000A 60.00A 600.0A 6000A Input Terminal IVSL/IVSH V.S. SGND IVSL/IVSH V.S. SGND ADP V.S. SGND ADP V.S. SGND ADP V.S. SGND ADP V.S. SGND 8 Full scale 600.0mV 600.0mV 600.0mV 600.0mV 600.0mV 600.0mV 12/09/07 ES51929 6000 Counts Smart DMM 1.3 Resistance Measurement A re-configurable divider automatically provides a suitable full-scale range in resistance measurement mode. The following table summarizes the full-scale ranges and the reference resistors in each configuration. Configuration OR1 OR2 OR3 OR4 OR5 OR6 Full Scale Range 600.0Ω* 6.000KΩ 60.00KΩ 600.0KΩ 6.000MΩ 60.00MΩ** Relative Resistor OR1 VR5 VR4 VR3‖VR1 VR2‖VR1 VR1 Equivalent value 100Ω 1KΩ 10KΩ 100KΩ 1MΩ 10MΩ Note: * When auto scan mode is set, continuity check is implemented in this range ** When auto scan mode is set, the 60.00MΩ range is omitted 1.3.1 Continuity check Continuity check shares the same configuration with 600.0Ω manual resistance measurement mode and has buzzer output to indicate continuity. The buzzer generates 2KHz beep whenever the reading is less than 30Ω. 1.4 Diode Measurement Diode measurement mode shares the same configuration with 6.000V manual voltage measurement mode and has buzzer output to indicate continuity. The buzzer generates a 2KHz sound whenever the reading is less than 30mV. If the test circuit is open or the voltage drop between the two ports of the device (diode) under test is larger than 2V, the LCD panel will show “OL”. Ver 1.2 9 12/09/07 ES51929 6000 Counts Smart DMM 1.5 Capacitance Measurement The following table summarizes the eight ranges of capacitance measurement mode: Configuration C1 C2 C3 C4 C5 C6 C7 C8 Full Scale Range 6.000nF*** 60.00nF 600.0nF 6.000uF 60.00uF 600.0uF 6.000mF* 60.00mF** Relative Resistor 20kΩVR+100kΩ 20kΩVR+100kΩ 101kΩ 10kΩ R9K / R1K R9K / R1K R9K / R1K R9K / R1K Note: * & ** *** The C7-C8 both range is not available for auto scan mode When the nF_OPT pin is pulled to V- level, the residual capacitance mode is enabled. Connect a compensation capacitance to OVH terminal for lower capacitance measurement accuracy if necessary. In order to obtain an accurate reading, a capacitor must be discharged before measurement begins. The chip has a built-in discharge mode to automatically discharge the capacitor. In discharge mode, the LCD displays “dIS.C” Discharging through the chip is quite slow. We recommend users to discharge the capacitor with some other apparatus. 1.6 Auto power off mode (APO) 1.6.1 Idle Time selection ES51929 has a default auto power off function. If the meter is idle for more than the given Idle Time, the chip automatically turns the power off. The idle time to trigger the auto power off function is determined by pin ‘APOSEL’. If pin APOSEL is connected to V-, the Idle Time will be set to 3 minutes. If pin APOSEL is connected to DGND or floating, the Idle Time will be set to 10 minutes. When APO happens, the state of the meter is saved. If the APO is necessary to be cancelled, power on the ES51929 when any of the push key, except for HOLD, is pressed down simultaneously. Ver 1.2 10 12/09/07 ES51929 6000 Counts Smart DMM 1.6.2 Sleep output The meter enters sleep mode after auto power-off or push SEL key to last for 2s. The SLEEP pin asserts low (-3V) in the sleep mode, and asserts high (+3V, not 0V) after re-power on. 1.6.3 Re-power on After auto power-off is active, pushing any of the push function can turn on the meter again. If the meter is re-powered on by push functions, the chip restores the saved state and enters HOLD mode. The LCD displays the saved value except for the auto scan mode. Ver 1.2 11 12/09/07 ES51929 6000 Counts Smart DMM 2. Functional Modes Table Measurement mode depends on the logic level of FC1, FC2, FC3, FUA, FA, VON, AON, NCV_EN and CLAMP. FC1 FC2 FC3 FUA 1 1 1 1 1 1 1 1 1 0 0 0 1 1 X X X X X X X X X 1 0 1 0 1 0 0 0 0 0 0 0 0 0 0 1 1 1 1 X X 1 0 0 X X 1 0 X X X X X FA X X 0 0 1 X X 0 0 X X X X X VON X X X X X 1 1 0 0 X 0 0 0 0 AON 0 0 1 1 1 X X X X X X X X X NCV_EN CLAMP 1 0 1 1 1 1 0 1 1 1 1 1 1 1 0 0 0 0 0 1 1 1 1 X 1 1 1 1 Functional Mode(pushing SEL key) VAUTOVACVDCEF*VAUTO… EF IAUTOIACIDCIAUTO…(uA) IAUTOIACIDCIAUTO…(mA) IAUTOIACIDCIAUTO…(A) VAUTOVACVDCVAUTO… EF IAC(600.0A/6000A) IAC(60.00A/600.0A) RDCAUTORDCRDCAUTO… IAUTOIACIDCIAUTO…(6.000A) IAUTOIACIDCIAUTO…(60.00A) IAUTOIACIDCIAUTO…(600.0A) IAUTOIACIDCIAUTO…(6000A) Input VR1,ADP ADP IVSH/IVSL IVSH/IVSL IVSH VR1 ADP IVSH/IVSL IVSH/IVSL VR1 ADP ADP ADP ADP Note: * EF mode could be selected when EF_EN is active. 3. Push Function All the enabled push functions will be reset when the measurement mode is changed by external switch. Change measurement mode by SEL function will reset enabled RANGE, HOLD, MAX/MIN, and VAHz functions. The following table lists the available function versus every measurement mode. SEL RANGE HOLD MAX/MIN VSCAN O X O X VAC O O O O VDC O O O O EF O X X X ISCAN O X O X IAC O O* O O IDC O O* O O RDCSCAN O X O X Resistance O O O O Continuity O X O O Diode O X O O Capacitance O O O O Note: For ADP input, RANGE is not available Ver 1.2 12 VAHz O O O X O O O X X X X X BKLIT O O O O O O O O O O O O ZERO X X X X O X O X X X X X 12/09/07 ES51929 6000 Counts Smart DMM 3.1 Select function When power on or SEL key is pressed longer than one second, ES51929 will be power-on reset to auto scan mode, which scanning mode is determined by [FC1-FC3] function set. In auto scan mode, the ES51929 automatically selects the appropriate measurement mode and range. Pushing the SEL key less than one second could select the target measurement function. Pushing the key larger than two seconds, the ES51929 will enter power down mode. If power down mode is entered, only press SEL key to last for one second or apply the power to Vterminal could re-power on the ES51929. The following figure shows the state transition. Note: If PWRSEL (pin28) is pulled to V-, the power control feature for SEL key will be disabled. Push SEL key < 1s V/A ac/dc auto scan Push SEL key > 1s Power on reset AC mode measurement DC mode measurement EF* mode measurement Push SEL key > 2s enter power down mode R/D/C auto scan Continuity measurement Resistance measurement Diode measurement Capacitance measurement Push SEL key < 1s Note: * Available when EF_EN is active only Ver 1.2 13 12/09/07 ES51929 6000 Counts Smart DMM 3.2 Range function RANGE pin switches to and from automatic and manual mode, and while in manual mode, changes the full-scale range. The following figure shows the state transition. Automatic Mode 1 push < 1 sec Manual Mode 1 push > 1 sec Range up 1 push < 1 sec 3.3 Hold and delay-hold function The data hold mode makes the meter stop updating the LCD panel. This mode can be nested in most of the special modes. In auto scanning mode, the HOLD key will be available. Enabling hold function in automatic mode makes the meter switch to manual mode. Hold function can be cancelled by changing the measurement mode, pressing RANGE, or push HOLD again. The delay-hold function is enabled when HOLD key is pressed larger than 2 seconds. When delay-hold function is entered successfully, the meter will stop to update the LCD data after six seconds delayed. During the six seconds waiting, the HOLD symbol on LCD panel will be blinking. Ver 1.2 14 12/09/07 ES51929 6000 Counts Smart DMM 3.4 Max/Min + Hold function The meter displays the maximum or minimum value of the input in Max/Min mode. When MAX/MIN is pressed for the first time, the meter displays the maximum value. The meter displays the minimum value, when it is pressed again. When MAX/MIN is pressed for the third time, the meter displays current value. The meter returns to normal operation if MAX/MIN is pressed and held for longer than one second. Pressing HOLD key in Max/Min mode makes the meter stop updating the maximum or the minimum value. 1 push<1s Original state (Automatic/manual) 1 push>1s 1 push>1 sec 1 push>1 sec “MAX” active 1push<1s “MIN” active 1push<1s “Max” “MIN” blink min value current value max value Push HOLD 1push<1s Push HOLD Push HOLD “MAX”“MIN” “H” blink “MIN” “H” active “MAX” “H” active hold max value. 1push<1s hold min value. 1push<1s hold current value. 1push<1s 3.5 VAHz function When voltage or current measurement mode is selected, the VAHz funtion is available. Push VAHz key to select this frequency measurement mode. The frequency is measured by auto ranging. The maximum frequency range is 100kHz. The sensitivity of signal input is 10% full scale of voltage or current mode typically. Configuration FR1 FR2 FR3 Ver 1.2 Range 6.000KHz 60.00KHz 100.0KHz 15 12/09/07 ES51929 6000 Counts Smart DMM 3.6 ZERO function In 6.000A, 60.00A, 600.0A and 6000A IDC & ISCAN mesurement modes, ES51929 provides Zero function to remove the residual current value. Push ZERO key less than one second to enter Zero mode. In Zero mode, the LCD panel displays DN+K - DN, where N = 1, 2, 3, … , DN is the last conversion value before Zero is pushed, and DN+K is the current conversion value. If Zero is pushed again in Zero mode, the meter will refresh the DN value and displays the DN+K - DN again. Pressing HOLD in Zero mode makes the meter stop updating the LCD panel. State diagram for Zero mode: Original State Press Zero ‘Zero’ Active Press Zero < 1s Show DN+K - DN State diagram for Zero + HOLD mode Original State Press Zero ‘Zero’ Active Press Zero < 1s Show DN+K - DN Press Hold ‘Zero’ ‘Hold’ Active Stop LCD upgrading Ver 1.2 16 12/09/07 ES51929 6000 Counts Smart DMM State diagram for Zero + Max/Min + HOLD mode: Original State Push Zero ‘Zero’ Active Push Zero < 1s Show DN+K - DN Push Max/Min > 1s Push Max/Min ‘Zero’ ‘Max’ Active ‘Zero’ ‘Min’ Active 〝Zero〞〝Max〞〝Min〞 Show Max. DN+K - DN Show Min. DN+K - DN blink. Current DN+K - DN Push Max/Min Push HOLD Push Max/Min Push HOLD Push HOLD 〝Zero〞 〝Max〞 , 〝Min〞 , , ‘Zero’ ‘Max’ ‘Hold’ ‘Zero’ ‘Min’ ‘Hold’ 〝H〞blink. Hold the active Hold Max. active Hold Min. Push Max/Min Push Max/Min DN+K - DN Value DN+K - DN Value current DN+K - DN Push Max/Min Ver 1.2 17 12/09/07 ES51929 6000 Counts Smart DMM 3.7 Back light function When BKSEL is set to DGND or floating, push the BKLIT key to enable the back light output driving ON/OFF. If the auto back light configuration is active, the BKLIT becomes a control input for external light sensed circuit. Set to low for one second to active the back light output driving. Set to high then the driving output is inactive immediately. BKSEL DGND or floating V- 4. Configuration Normal back light function Auto back light function Miscellaneous The conditions, which the meter turns on the buzzer, include: (1) Changing measurement mode generates one beep. (2) Pressing any of the push functions generates one beep, if the function is valid. (3) Power on and re-power on generate one beep. (4) Input overflow in voltage and current mode generates one beep every 0.3 seconds (or 3.33 beeps per second.) (5) Continuity (diode) check generates a continuous 2KHz beep whenever the measurement is less then 30Ω(30mV) (6) Auto power off or power down by SEL key generates a 2KHz beeper that lasts for 1.5 seconds. The following figures show the output waveform from the BUZOUT pin. 0.5 mS (a) Continuous 2KHz beep 0.15 sec 0.3 sec (b) 3.33 beep/sec Ver 1.2 18 12/09/07 ES51929 6000 Counts Smart DMM 4.1 LCD configuration SEG01 SEG02 SEG03 SEG04 SEG05 SEG06 SEG07 SEG08 SEG09 BP1 SCAN AUTO A4 MANU A3 HOLD APO BP2 AC F4 B4 F3 B3 F2 A2 B2 BP3 DC E4 G4 E3 G3 E2 G2 C2 BP4 BATT DP3 D4 C4 D3 C3 DP2 D2 DP1 SEG10 SEG11 SEG12 SEG13 SEG14 SEG15 BP1 A1 BP2 F1 BP3 BP4 Ver 1.2 µ2 M n MAX B1 m2 K µ1 MIN E1 G1 V Ω m1 ZERO D1 C1 A F Hz 19 12/09/07 ES51929 6000 Counts Smart DMM LCD Backplane Waveform V- +3.2 VV- +3.2 VV- +3.2 VV- +3.2 VV- +3.2 V- 4.2 LCD display on condition LCD annunciates V A Ω F Hz DC AC SCAN AUTO MANU HOLD Max / Min Zero m1 µ1 n m2 µ2 M K APO Ver 1.2 Condition In voltage measurement mode, and diode measurement mode. In current measurement mode. In resistance measurement mode, and continuity mode. In capacitance measurement mode. In continuity check mode. In diode mode. In VAHZ frequency mode. In DC voltage or DC current mode. In AC voltage or AC current mode. When auto scan mode is selected When automatic full scale range selection is enabled. In manual mode. When the reading is exceeding 30V in DCV or ACV, the DNAGER symbol will be displayed on When HOLD function is enabled. When delay-hold is selected, the HOLD symbol will be blinking for 6 seconds. When Max or Min function is enabled. When Zero function is enabled. In capacitor measurement mode and the full scale range is in the order of mF. In capacitor measurement mode and the full scale range is in the order of uF. In capacitor measurement mode and the full scale range is in the order of nF. In voltage or current measurement mode and the full scale range is in the order of 10-3. In current measurement mode and the full scale range id in the order of uA. In resistance measurement mode and the full scale range is in the order of MΩ In resistance measurement mode and the full scale range is in the order of KΩ When auto power off function is enabled. 20 12/09/07 ES51929 6000 Counts Smart DMM Test Circuit 1. Voltage test 4. Current test AGND OVSG 100 1K 10K 101K 1.111M D2 D1 1.0u 15K 10K OR1 VR5 VR4 VR3 VR2 ADO ADI ACVL ACVH TEST5 15K 1.0u +4.7u 10K 0.005 AGND SGND 60A 0.495 mA 4.5 A mA uA V R 1 V R mA 50 100K uA uA 100K 5. Diode test 10M AGND -400mV Voltage input 22n 470n PTC 1.5K 47n 100 Z1 6V Z2 100 1K 10K 101K 1.111M OVH 100 Z1 6V Z2 2. Resistance test 220n IVSH IVSL 450 PTC 1.5K 10M OVX OHMC4 OHMC3 1.111M OHMC2 VR1 VR2 OVSG OHMC1 OVH OVSG 6. Low battery OR1 VR5 VR4 VR3 VR2 9V 680K BA SGND AGND TT 270K LBAT9 0.1u AGND V- 0V 3. Current test for clampmeter 7. EF test RL Ver 1.2 VR R EFin+ 100K ADP EFin- SGND AGND 100k 120M ADP SGND AGND VA+ 400mV 21 VA- 12/09/07 D C 1 SWSPDT J2 1 ZR1 ZR5 R1 450 R2 45 R3 4.5 R4 0.495 R5 0.005 SW2 ZR2 SW3 SW4 ZR6 uA uA mA 60A mA SWSPST SW5 SW6 SW26 SW7 R/C/D/Cont R6 2 100K 4.7uF C24 R11 20K IVSH IVSL SW23 Power Switch 5.6V 10uF V- 470K 150K 100K 100K 220nF 220nF 7.5V 0.1uF V + ZR11 C7 C8 C26 (Optional) 100 C6 220pF R7 R8 R9 R10 C22 10uF C23 0.1uF C21 ZR10 Regulator DC3.0V VR1 ADI TEST5 R17 1.5K PTC ZR7 ZR8 C10 R12 R13 R14 R15 R18 C9 0.1uF 3 BT1 3V 5.6V 0.1uF 10uF ZR3 C3 7.5V ZR4 C4 C1 10uF C2 0.1uF U1 470nF AGND LBAT CREF+ CREFCINT CAZ BUFF RAZ IVSH IVSL OVX OVH OVSG OR1 VR5 VR4 VR3 VR2 TEST5 ACVL ACVH ADI ADO OHMC4 OHMC3 C14 ADP 27K VR3 VR 1uF 47nF C12 C15 C13 220nF 1 LBAT 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 100 1K 10K 101K 1.11M TEST5 ACVL ACVH ADI ADO C11 22nF R23 + 1 SWSPST R22 15K 10K R/C/D/Cont VR1_10M R16 C18 1uF ACVH + J4 IN 10K IN4148 D2 ADO ACVL 3 + uA SW1 mA Gnd 60A 1 J3 + C17 1uF VR2 Average Circuit R21 15K 1N4148 D1 2 + B A 1 V- 4 SEG01 SEG02 SEG03 SEG04 SEG05 SEG06 SEG07 SEG08 SEG09 NCV_EN 10K 1 J5 ES51929 C16 C19 R26 9K R25 1K 4 SEG10 SEG11 ZR9 V- ZERO nF_en ES7PWR APOSEL BUZIN SLEEP SEG12 SEG13 SEG14 SEG15 CLAMP VON AON FA FUA FC3 FC2 FC1 HOLD SEL VAHz RANGE MAX/MIN BKLIT EFEN BP1 BP2 BP3 BP4 ANNUNC BKOUT 5.6V BZ1 Buzzer 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 SEG12 SEG13 SEG14 SEG15 CLAMP VON AON FA FUA FC3 FC2 FC1 HOLD SEL VAHZ RANGE MAX/MIN BKLIT EFEN BP1 BP2 BP3 BP4 ANNUNC 5 5 LCD Panel SEG01 SEG02 SEG03 SEG04 SEG05 SEG06 SEG07 SEG08 SEG09 SEG10 SEG11 SEG12 SEG13 SEG14 SEG15 BP1 BP2 BP3 BP4 BKLIT J1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 CON19 SW8 SW10 MAX/MIN SW9 RANGE SW12 SW11 SEL SW13 VAHZ HOLD SW24 Number SW_nonlock SW_nonlock SW_nonlock SW_nonlock SW_nonlock SW_nonlock 21-Aug-2012 F:\Protelfile\KA025\KA025.ddb V- 6 SW_lock SW22 SW_lock SW21 SW_lock SW20 SW_lock SW19 SW_lock SW18 SW_lock SW17 SW_lock SW16 SW_lock SW15 CLAMP SW14 VON AON FA FUA FC3 FC2 FC1 EFEN 6 Revision NCV_EN SW_lock SW25 nF_en SW_lock NCV_EN SW27 Sheet of Drawn By: Application Circuit ( Average ) ES51929 6000 Counts Smart DMM ZERO SW_nonlock Function Switch Title Size B Date: File: V- D C B A 12/09/07 22 Ver 1.2 100K + 4MHz Y1 C5 0.47uF CESEL BKSEL + 100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76 VR1_10M R20 + AGND DGND V+ V+ VVCC+ CESEL BKSEL OSC1 OSC2 SEG01 SEG02 SEG03 SEG04 SEG05 SEG06 SEG07 SEG08 SEG09 NCV_EN NC SEG10 SEG11 R24 + OHMC2 OHMC1 PWRSEL VRH VR SGND ADP VA+ VAVR1 NC CACA+ R9K R1K SLEEP BUZIN APOSEL BUZOUT ACEN NC NC NC nF_OPT ZERO R19 26 27 PWRSEL 28 56K 29 30 31 32 33 VA+ 34 VA10M 35 36 37 470nF 38 39 40 41 42 43 44 45 46 47 48 49 50 220nF + 6000 Counts Smart DMM ES51929 Application Circuit a.) AC average rectified circuit Notes: 1. The ESD protection circuits protect most of pins. However pins, V+, V-, AGND, DGND and VR1 are not protected enough because the parasitic effect must be decrease. Therefore enough external protection is needed for assembling, carrying and keeping. In addition, components connecting to these unprotected pins have to be soldered on board before the IC is soldered. 2. All the zener diodes above are used for IC protection. These protections are needed and these zener diodes must be soldered on PCB first before soldering ES51929 on. 3. The OVX pin resistance have to be kept below 120kΩ for the capacitance mode accuracy (6/60nF range). For higher voltage protection, additional configuration of PTC protection is necessary. D C 1 LCD Panel SEG01 SEG02 SEG03 SEG04 SEG05 SEG06 SEG07 SEG08 SEG09 SEG10 SEG11 SEG12 SEG13 SEG14 SEG15 BP1 BP2 BP3 BP4 uA SW1 2 1 1 ZR1 ZR5 R1 450 R2 45 R3 4.5 R4 0.495 R5 0.005 SW2 ZR2 SW3 SW4 ZR6 SW8 SW9 uA uA mA mA 60A R/C/D/Cont SWSPST SW27 SWSPST SW10 R/C/D/Cont R6 ZR8 1.5K PTC 100K 3 ZR7 R7 VR1 - 20K R12 5K C26 IVSH IVSL R25 SW24 Power Switch 5.6V V- 4 0.1uF BT1 3V 10uF 5.6V 0.1uF ZR3 C3 7.5V ZR4 C4 U1 C2 0.1uF 7.5V 220nF 220nF 470nF AGND LBAT CREF+ CREFCINT CAZ BUFF RAZ IVSH IVSL OVX OVH OVSG OR1 VR5 VR4 VR3 VR2 TEST5 ACVL ACVH ADI ADO OHMC4 OHMC3 47nF ADP 27K VR2 VR 1uF C13 C11 C14 C12 220nF C1 10uF C9 1 LBAT 2 3 4 5 6 7 8 9 10 11 12 13 14 100 15 1K 16 10K 17 101K 18 1.11M 19 20 ACVL 21 ACVH 22 23 24 25 ADO R20 C10 22nF 0.1uF V + ZR11 R13 R14 R15 R16 R17 SW_lock SW17 10uF C7 C8 470K 150K 100K 100K ACV / RMS C6 220pF R8 R9 R10 R11 1.5K -VS_ES7 ACVH C28 (Optional) 100 C24 10uF C25 0.1uF C23 ZR10 Regulator DC3.0V + VR4 100K 6 U3 TL061 -VS_ES7 +VS_ES7 R19 2 3 R24 10K + IN J3 J2 SWSPDT mA Gnd 60A J4 1 VR1_10M + C20 2.2uF + V- V- J1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 CON19 SW_nonlock SW_nonlock SW_nonlock SW_nonlock SW_nonlock SW_nonlock SW_nonlock SW14 +VS_ES7 8 7 6 5 ADO + SW5 Function Switch BKLIT SW7 MAX/MIN SW6 SW11 RANGE SW12 SW13 VAHZ HOLD SW25 SEL ZERO CLAMP TRMS Circuit -VS_ES7 1uF 1 COM RL 2 + VS Vin 3 PwrDown Vout 4 - VS Cav U2 ES7 C19 2.2uF +VS_ES7 C18 10K 1 J5 V- 100K SW_lock SW15 SW_lock SW16 ES7PWR R18 47K C5 0.47uF 5 ES51929 VR1_10M R22 VON SW_lock SW18 SW_lock SW19 10uF C17 + C15 C21 AON FA FUA C16 -VS_ES7 +VS_ES7 10uF 50K 4 SEG01 SEG02 SEG03 SEG04 SEG05 SEG06 SEG07 SEG08 SEG09 NCV_EN 4MHz Y1 CESEL BKSEL + R21 + + SEG10 SEG11 100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76 5 ZR9 Number BZ1 Buzzer 5.6V V- 21-Aug-2012 F:\Protelfile\KA025\KA025.ddb 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 SEG12 SEG13 SEG14 SEG15 CLAMP VON AON FA FUA FC3 FC2 FC1 HOLD SEL VAHZ RANGE MAX/MIN BKLIT EFEN BP1 BP2 BP3 BP4 ANNUNC Sheet of Drawn By: Application Circuit ( TRMS ) ES51929 6000 Counts Smart DMM R23 9K R27 1K Title Size B Date: File: ZERO nF_en ES7PWR APOSEL BUZIN SLEEP SEG12 SEG13 SEG14 SEG15 CLAMP VON AON FA FUA FC3 FC2 FC1 HOLD SEL VAHz RANGE MAX/MIN BKLIT EFEN BP1 BP2 BP3 BP4 ANNUNC BKOUT AGND DGND V+ V+ VVCC+ CESEL BKSEL OSC1 OSC2 SEG01 SEG02 SEG03 SEG04 SEG05 SEG06 SEG07 SEG08 SEG09 NCV_EN NC SEG10 SEG11 OHMC2 OHMC1 PWRSEL VRH VR SGND ADP VA+ VAVR1 NC CACA+ R9K R1K SLEEP BUZIN APOSEL BUZOUT ACEN NC NC NC nF_OPT ZERO R26 + 26 27 PWRSEL 28 56K 29 30 31 32 33 VA+ 34 VA10M 35 36 37 470nF 38 39 40 41 42 43 44 45 46 47 48 49 50 220nF SW_lock SW20 SW_lock SW21 SW_lock SW22 SW_lock SW23 VR3 3 7 5 4 1 FC3 FC2 FC1 EFEN 2 + 6 6 Revision D C B A 12/09/07 23 Ver 1.2 B A NCV_EN SW_lock SW26 nF_en SW_lock NCV_EN SW28 1 + 6000 Counts Smart DMM ES51929 b.) AC RMS circuit (I) Notes: 1. The ESD protection circuits protect most of pins. However pins, V+, V-, AGND, DGND and VR1 are not protected enough because the parasitic effect must be decrease. Therefore enough external protection is needed for assembling, carrying and keeping. In addition, components connecting to these unprotected pins have to be soldered on board before the IC is soldered. 2. All the zener diodes above are used for IC protection. These protections are needed and these zener diodes must be soldered on PCB first before soldering ES51929 on. 3. The OVX pin resistance have to be kept below 120kΩ for the capacitance mode accuracy (6/60nF range). For higher voltage protection, additional configuration of PTC protection is necessary. 1 LCD Panel J1 2 J2 SWSPDT uA SW1 mA 60A Gnd J3 1 1 IN ZR1 ZR5 R1 450 R2 45 R3 4.5 R4 0.495 R5 0.005 SW2 ZR2 SW3 SW4 ZR6 SW8 SW9 uA uA mA mA 60A R/C/D/Cont SWSPST SW27 SWSPST SW10 R/C/D/Cont R6 3 100K VR1 Regulator DC3.0V ZR10 C23 C26 IVSH IVSL SW24 Power Switch 5.6V V- 4 BT1 3V 5.6V 0.1uF 10uF ZR3 C4 7.5V ZR4 C3 470nF AGND LBAT CREF+ CREFCINT CAZ BUFF RAZ IVSH IVSL OVX OVH OVSG OR1 VR5 VR4 VR3 VR2 TEST5 ACVL ACVH ADI ADO OHMC4 OHMC3 U1 10uF V + ZR11 7.5V 220nF 220nF 470K 150K 100K 100K 0.1uF C2 0.1uF C9 1 LBAT 2 3 4 5 6 7 8 9 10 11 12 13 14 100 15 1K 16 10K 17 101K 18 1.11M 19 20 ACVL 21 ACVH 22 23 24 25 ADO 47nF ADP 27K VR2 VR 1uF C13 C11 C14 C12 220nF C1 10uF R13 R14 R15 R16 R17 SW17 SW_lock R20 C10 22nF 0.1uF C7 C8 R8 R9 R10 R11 ACV / RMS C6 220pF C28 (Optional) 100 C24 10uF C25 0.1uF 20K R12 VS+ ACVH 22uF R25 150 R7 1.5K PTC ZR7 ZR8 C19 VS+ VS- VS- + V- 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 CON19 SW_nonlock SW_nonlock SW_nonlock SW_nonlock SW_nonlock 1 14 13 12 11 10 9 8 C16 10uF C17 + + SW12 SW_nonlock J4 VR1_10M U2 Buff Out Buff In Vin NC NC Common Output Offset + VS CS - VS DEN Input RMS OUT dBOutput Cav ES6 10uF + SW13 V- ADO 100K 5.1K 1 2 3 4 5 6 7 C18 4.7uF + D SEG01 SEG02 SEG03 SEG04 SEG05 SEG06 SEG07 SEG08 SEG09 SEG10 SEG11 SEG12 SEG13 SEG14 SEG15 BP1 BP2 BP3 BP4 SW5 Function Switch BKLIT SW7 MAX/MIN SW6 RANGE SEL SW25 SW11 HOLD VAHZ ZERO SW_nonlock CLAMP SW14 SW_lock SW16 SW_lock SW15 R19 R24 TRMS Circuit VSVR3 500K VS+ VR4 2K 4 V- C5 0.47uF 10K 1 J5 5 ES51929 VR1_10M R22 VON SW_lock SW18 SW_lock SW19 SW_lock SW20 SW_lock SW21 SW_lock SW22 SW_lock SW23 3 C15 C21 AON FA FUA FC3 FC2 FC1 EFEN 2 100K C B A SW_lock SW26 SW_lock SW28 NCV_EN SEG01 SEG02 SEG03 SEG04 SEG05 SEG06 SEG07 SEG08 SEG09 NCV_EN 4MHz Y1 CESEL BKSEL + R21 + + SEG10 SEG11 100 99 98 97 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76 5 ZR9 5.6V BZ1 Buzzer V- 75 74 73 72 71 70 69 68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 SEG12 SEG13 SEG14 SEG15 CLAMP VON AON FA FUA FC3 FC2 FC1 HOLD SEL VAHZ RANGE MAX/MIN BKLIT EFEN BP1 BP2 BP3 BP4 ANNUNC Sheet of Drawn By: Application Circuit ( TRMS ) 7-Sep-2012 F:\Protelfile\KA025\KA025.ddb Number ES51929 6000 Counts Smart DMM R23 9K R27 1K Title Size B Date: File: ZERO nF_en ES7PWR APOSEL BUZIN SLEEP SEG12 SEG13 SEG14 SEG15 CLAMP VON AON FA FUA FC3 FC2 FC1 HOLD SEL VAHz RANGE MAX/MIN BKLIT EFEN BP1 BP2 BP3 BP4 ANNUNC BKOUT AGND DGND V+ V+ VVCC+ CESEL BKSEL OSC1 OSC2 SEG01 SEG02 SEG03 SEG04 SEG05 SEG06 SEG07 SEG08 SEG09 NCV_EN NC SEG10 SEG11 OHMC2 OHMC1 PWRSEL VRH VR SGND ADP VA+ VAVR1 NC CACA+ R9K R1K SLEEP BUZIN APOSEL BUZOUT ACEN NC NC NC nF_OPT ZERO R26 + 26 27 PWRSEL 28 56K 29 30 31 32 33 VA+ 34 VA10M 35 36 37 470nF 38 39 40 41 42 43 44 45 46 47 48 49 50 220nF + 6 6 Revision D C B A 12/09/07 24 Ver 1.2 nF_en NCV_EN 1 + 6000 Counts Smart DMM ES51929 c.) AC RMS circuit (II) ES51929 6000 Counts Smart DMM Package Information 7.1 100 Pin LQFP Package 7.2 Dimension Parameters Ver 1.2 25 12/09/07