0.5A 125V AC Qualified Type

SDKN
0.5A 125V AC Qualified Type
Detector
Compact and low-profile for primary /
secondary switching with compatibility to low level rating
■ Ratings and Safety Standards
Items
Specifications
Slide
Ratings satisfying local electrical
appliance and material safety law
0.5A 125V AC
0.25A 250V AC
DC ratings
5mA 5V DC
Push
Product Line
Rotary
Circuit
arrangement
Rating
SPDT
0.5A 125V AC
0.25A 250V AC
5mA 5V DC
Total travel
(mm)
Operating force
9
3.5±1N
Mounting
method
Operation
type
Japan
Export
100
1,250
Push
Snap-in
9.7
Minimum order unit(pcs.)
2±1.5N
Lever
Product No.
Drawing
No.
SDKNA20900
1
SDKNA20700
2
Power
Note
Safety standard approval must be obtained as a set.
Number of packages(pcs.)
1 case /Japan
Export package measurements(mm)
1 case /export packing
250 1,250
389×276×380
Unit:mm
No.
Style
Mounting hole dimensions
Rocker
Type
Push
11.3
8.5
6
Off position of circuit c-2
R1
11.3
7.9
4.2
Direction of insertion
t
1.7
R
15.75
6.5
2
Rotary
Type
1
Total travel
position
22.9
On position of circuit c-1
13
11.2
Slide
Type
15
25
14.4min.
Push
Type
Dimensions
12.5min.
Dual-in-line
Package Type
Packing Specifications
Bulk
15
t=0.8-1.5mm
Terminal No. 1
11
162
Terminal No. c
Terminal No. 2
SDKN/0.5A 125V AC Qualified Type
Unit:mm
No.
Style
Mounting hole dimensions
25
11.3
15
Slide
Lever
Detector
Dimensions
22.9
Within the ON range of the C-1 circuit
11
Within the OFF range of the C-2 circuit
1.7
t
R
14.1 min.
12.2 min.
Direction of insertion
15
t=0.8-1.5mm
Terminal No.2
Terminal No.C
Connector corresponds to [HLP-03V], manufactured by the J.S.T. Mfg. Co., Ltd.
C
2
Dual-in-line
Package Type
Note
Circuit Diagram
Power
Terminal No.1
11
SPDT
Rotary
15.5
5.5
3
2
R1
11.2
8
2
Push
Total travel
position
0.
1.8
R
5.1
1.7
1
Push
Type
0.5A 125V AC Qualified Type / Cautions
Slide
Type
Rotary
Type
(1)Setting of thresh voltage
A 4V or larger voltage difference between switch ON and OFF is recommended. Thresh voltage should be
set to the center.
Rocker
Type
1.This product does not have a water-proof or drip-proof construction. Prevent ingress of water into the switch.
Avoid using around spilt or flowing. It may cause deterioration of the insulation.
2.Do not apply load on the connecter or lead wire(code)attached to the product. Using the product with load
applied on the connecter / lead wire might cause terminal wobble or contact failures.
3.ON / OFF signal reading(For DC ratings)
Shall be considered when designing circuit and software as follows.
4V min.
Thresh voltage
0V
(2)ON / OFF signal reading
ON / OFF signal reading intervals should be at a minimum of 50ms with at least 3 repetitions.
Reading of micro-computer
Times
1 2 3
50ms min.
4.Verify the performance under actual product conditions before use.
163
Power Switches
List of Varieties
Type
Push
Detector
Series
Rocker
SDKR
SDDH
SDKN
0.5A 250V AC
1A 125V AC
10mA 5V DC
Rating(max.):4.5A 12V DC
(Lamp load: 27W×2)
Rating(min.):10mA 12V DC
(Resistive load)
0.25A 250V AC
0.5A 125V AC
5mA 5V DC
SDDJE ※ 1
SDDJF ※ 1
※ 2
10AGP 250V AC
6A / 96A 250V〜
16AGP 250V AC
16(6)/ 250〜
※2
Photo
Slide
Rating
Push
100,000cycles
Operating life
5,200cycles
10,000cycles
100,000 cycles
0.5A 250V AC
0.25A 250V AC
10A 250V AC
16A 250V AC
Rotary
Power
Dual-in-line
Package Type
Travel(mm)
1.5
3.7
9
9.7
3.4
5.2
Features
Water-proof type
With signal circuit
Water-proof
(IP68 rating)
—
—
—
Operating temperature range
−10℃ to +85℃
−15℃ to+80℃
−20℃ to +60℃
Automotive use
—
●
—
100mΩ max.( AC switch)
500mΩ max.(DC switch)
500mΩ max.
100mΩ max.
100mΩ max.
100MΩ min. 500V DC
500MΩ min. 500V DC
−10℃ to +55℃
○
○
Life cycle (availability)
Contact
resistance
Electrical
performance
Insulation
resistance
Push
Type
Voltage proof
Terminal strength
Rocker
Type
Mechanical
performance
Operating
Actuator direction
strength Perpendicular
direction
Slide
Type
Environmental
performance
500MΩ min. 500V DC
(AC switch)
10MΩ min. 500V DC
100MΩ min. 100V DC
(DC switch)
1000V AC for 1minute
(AC switch)
500V AC for 1minute 600V AC for 1minute
100V AC for 1minute
(DC switch)
2,000V AC for 1minute
Slider pull-out strength:
100N min.
50N for 1minute
50N for 1minute
60N for 1minute
(Lead terminal)
(Lead terminal)
5N for 1minute
10N for 1minute
(Right-angle terminal) (Right-angle terminal)
20N
25N
30N
25N
−30℃ 192h
−20℃ 96h
5N for 1minute
100N
20N
—
—
Rotary
Type
Cold
−20℃ 240h
−15℃ 96h
Dry heat
85℃ 240h
80℃ 96h
Damp heat
60℃,
90 to 95%RH 1000h
Page
160
70℃ 192h 40℃, 90 to 95%RH 192h
161
162
85℃ 96h
40℃, 90 to 95%RH 96h
164
168
Power Switches Soldering Conditions・ ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 176
Power Switches Cautions・ ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 176
Power Switches Safety Standard・ ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 176
Notes
1. ※1. Dip soldering can be used on SDDJE for PC board terminal and SDDJF right angle terminal types only.
2. ※2. T
he operating temperature range for automotive applications can be raised upon request. Please contact us for details.
3. ● Indicates applicability to all products in the series, while ○ indicates applicability to some products in the series.
158
Power Switches Soldering Conditions
Detector
Reference for Hand Soldering
Reference for Dip Soldering
Slide
Soldering
temperature
Soldering time
SDDJE, SDDJF, SDKP,
SDDJF1A, SDKZ, SDDE
350±10℃
3+1/0s
SDKR
300±10℃
3±0.5s
Series
(For PC board terminal types and SDDJF right-angle
terminal types)
Series
SDKR, SDDJE, SDDJF,
SDKP, SDKZ, SDDE
Dip soldering
Soldering temperature Duration of immersion
260±5℃
10±1s
Push
Power Switches Cautions
Rotary
Power
Dual-in-line
Package Type
1. The primary power supply switching is subject to the safety regulations, and the provisions differ by
each destination. Consult with us for non-standard use cases.
2. An unstable contact may occur if the switch current is lower than 0.5A. For this case, consult with us.
3. These power switches were produced for alternating current. For direct current, consult with us.
4. Appling load to terminals during soldering under certain conditions may cause deformation and electrical
property degradation.
5. Avoid use of water-soluble soldering flux, since it may corrode the switches.
6. When soldering twice, wait until the first soldered portion cools to normal temperature. Continuous
heating will deform the external portions, loosen or dislodge terminals, or may deteriorate their electrical
characteristics.
7. Before soldering switches with locking mechanism, release the locks. If they are soldered without
releasing the locks, the soldering heat may deform the locking mechanism.
8. Be sure to release the locks before removing the knobs. Otherwise, the locking mechanism may be
broken.
9. Be sure to use the switch with forced travel positioned as close to the total travel as possible.
Push
Type
10. Tighten the mounting screws by applying the specified torque. Tightening with a larger torque than the
specified will result in malfunction or breakage of screws.
11. Corrosive gas if generated by peripheral parts of a set, malfunction such as imperfect contact may
occur. Thorough investigation shall be required beforehand.
12. Storage
Rocker
Type
Store the products as delivered at normal temperature and humidity, out of direct sunlight and away
from corrosive gases. Use them as soon as possible and no later than six months after delivery.
Once the seal is broken, use them as soon as possible.
Slide
Type
Power Switches Safety Standards
1. Safety Standards Outline
Rotary
Type
Safety standards are established by a country or an organization representing it to protect
general users from electrical shock and fire hazards. It establishes standards for electrical
devices and components. For electrical equipment manufacturers, utilizing switches that have
been safety-approved ensures the safety of the switch. The use of a safety-approved switch also
simplifies at least one part of the process of obtaining certification by safety testing.
2. Major Safety Standards
Electrical Appliance and Material Safety Law
(1)
The conventional [Electrical Appliance and Material Control Law] has changed to [Electrical
Appliance and Material Safety Law] and has been enforced since April 1, 2001. Electrical
appliances are categorized into special electric appliances and parts(formerly Class A)and
Electrical appliances other than the special electric appliances(formerly Class B). Special
electric appliances are required to receive goodness of fit test at a certified test agency and to
store the certificate. Also, penal provisions have been reinforced.
UL
(2)
(Underwriters Laboratories Inc.)
Underwriters Laboratories Inc.(UL)is the American safety approving organization. Its purpose is
to ensure consumer safety and protect them from fire hazards. State law requires that equipment
to be exported to the United States utilize UL approved power switches or power switches
meeting UL standards and capable of passing UL tests.
176