SDKN 0.5A 125V AC Qualified Type Detector Compact and low-profile for primary / secondary switching with compatibility to low level rating ■ Ratings and Safety Standards Items Specifications Slide Ratings satisfying local electrical appliance and material safety law 0.5A 125V AC 0.25A 250V AC DC ratings 5mA 5V DC Push Product Line Rotary Circuit arrangement Rating SPDT 0.5A 125V AC 0.25A 250V AC 5mA 5V DC Total travel (mm) Operating force 9 3.5±1N Mounting method Operation type Japan Export 100 1,250 Push Snap-in 9.7 Minimum order unit(pcs.) 2±1.5N Lever Product No. Drawing No. SDKNA20900 1 SDKNA20700 2 Power Note Safety standard approval must be obtained as a set. Number of packages(pcs.) 1 case /Japan Export package measurements(mm) 1 case /export packing 250 1,250 389×276×380 Unit:mm No. Style Mounting hole dimensions Rocker Type Push 11.3 8.5 6 Off position of circuit c-2 R1 11.3 7.9 4.2 Direction of insertion t 1.7 R 15.75 6.5 2 Rotary Type 1 Total travel position 22.9 On position of circuit c-1 13 11.2 Slide Type 15 25 14.4min. Push Type Dimensions 12.5min. Dual-in-line Package Type Packing Specifications Bulk 15 t=0.8-1.5mm Terminal No. 1 11 162 Terminal No. c Terminal No. 2 SDKN/0.5A 125V AC Qualified Type Unit:mm No. Style Mounting hole dimensions 25 11.3 15 Slide Lever Detector Dimensions 22.9 Within the ON range of the C-1 circuit 11 Within the OFF range of the C-2 circuit 1.7 t R 14.1 min. 12.2 min. Direction of insertion 15 t=0.8-1.5mm Terminal No.2 Terminal No.C Connector corresponds to [HLP-03V], manufactured by the J.S.T. Mfg. Co., Ltd. C 2 Dual-in-line Package Type Note Circuit Diagram Power Terminal No.1 11 SPDT Rotary 15.5 5.5 3 2 R1 11.2 8 2 Push Total travel position 0. 1.8 R 5.1 1.7 1 Push Type 0.5A 125V AC Qualified Type / Cautions Slide Type Rotary Type (1)Setting of thresh voltage A 4V or larger voltage difference between switch ON and OFF is recommended. Thresh voltage should be set to the center. Rocker Type 1.This product does not have a water-proof or drip-proof construction. Prevent ingress of water into the switch. Avoid using around spilt or flowing. It may cause deterioration of the insulation. 2.Do not apply load on the connecter or lead wire(code)attached to the product. Using the product with load applied on the connecter / lead wire might cause terminal wobble or contact failures. 3.ON / OFF signal reading(For DC ratings) Shall be considered when designing circuit and software as follows. 4V min. Thresh voltage 0V (2)ON / OFF signal reading ON / OFF signal reading intervals should be at a minimum of 50ms with at least 3 repetitions. Reading of micro-computer Times 1 2 3 50ms min. 4.Verify the performance under actual product conditions before use. 163 Power Switches List of Varieties Type Push Detector Series Rocker SDKR SDDH SDKN 0.5A 250V AC 1A 125V AC 10mA 5V DC Rating(max.):4.5A 12V DC (Lamp load: 27W×2) Rating(min.):10mA 12V DC (Resistive load) 0.25A 250V AC 0.5A 125V AC 5mA 5V DC SDDJE ※ 1 SDDJF ※ 1 ※ 2 10AGP 250V AC 6A / 96A 250V〜 16AGP 250V AC 16(6)/ 250〜 ※2 Photo Slide Rating Push 100,000cycles Operating life 5,200cycles 10,000cycles 100,000 cycles 0.5A 250V AC 0.25A 250V AC 10A 250V AC 16A 250V AC Rotary Power Dual-in-line Package Type Travel(mm) 1.5 3.7 9 9.7 3.4 5.2 Features Water-proof type With signal circuit Water-proof (IP68 rating) — — — Operating temperature range −10℃ to +85℃ −15℃ to+80℃ −20℃ to +60℃ Automotive use — ● — 100mΩ max.( AC switch) 500mΩ max.(DC switch) 500mΩ max. 100mΩ max. 100mΩ max. 100MΩ min. 500V DC 500MΩ min. 500V DC −10℃ to +55℃ ○ ○ Life cycle (availability) Contact resistance Electrical performance Insulation resistance Push Type Voltage proof Terminal strength Rocker Type Mechanical performance Operating Actuator direction strength Perpendicular direction Slide Type Environmental performance 500MΩ min. 500V DC (AC switch) 10MΩ min. 500V DC 100MΩ min. 100V DC (DC switch) 1000V AC for 1minute (AC switch) 500V AC for 1minute 600V AC for 1minute 100V AC for 1minute (DC switch) 2,000V AC for 1minute Slider pull-out strength: 100N min. 50N for 1minute 50N for 1minute 60N for 1minute (Lead terminal) (Lead terminal) 5N for 1minute 10N for 1minute (Right-angle terminal) (Right-angle terminal) 20N 25N 30N 25N −30℃ 192h −20℃ 96h 5N for 1minute 100N 20N — — Rotary Type Cold −20℃ 240h −15℃ 96h Dry heat 85℃ 240h 80℃ 96h Damp heat 60℃, 90 to 95%RH 1000h Page 160 70℃ 192h 40℃, 90 to 95%RH 192h 161 162 85℃ 96h 40℃, 90 to 95%RH 96h 164 168 Power Switches Soldering Conditions・ ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 176 Power Switches Cautions・ ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 176 Power Switches Safety Standard・ ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 176 Notes 1. ※1. Dip soldering can be used on SDDJE for PC board terminal and SDDJF right angle terminal types only. 2. ※2. T he operating temperature range for automotive applications can be raised upon request. Please contact us for details. 3. ● Indicates applicability to all products in the series, while ○ indicates applicability to some products in the series. 158 Power Switches Soldering Conditions Detector Reference for Hand Soldering Reference for Dip Soldering Slide Soldering temperature Soldering time SDDJE, SDDJF, SDKP, SDDJF1A, SDKZ, SDDE 350±10℃ 3+1/0s SDKR 300±10℃ 3±0.5s Series (For PC board terminal types and SDDJF right-angle terminal types) Series SDKR, SDDJE, SDDJF, SDKP, SDKZ, SDDE Dip soldering Soldering temperature Duration of immersion 260±5℃ 10±1s Push Power Switches Cautions Rotary Power Dual-in-line Package Type 1. The primary power supply switching is subject to the safety regulations, and the provisions differ by each destination. Consult with us for non-standard use cases. 2. An unstable contact may occur if the switch current is lower than 0.5A. For this case, consult with us. 3. These power switches were produced for alternating current. For direct current, consult with us. 4. Appling load to terminals during soldering under certain conditions may cause deformation and electrical property degradation. 5. Avoid use of water-soluble soldering flux, since it may corrode the switches. 6. When soldering twice, wait until the first soldered portion cools to normal temperature. Continuous heating will deform the external portions, loosen or dislodge terminals, or may deteriorate their electrical characteristics. 7. Before soldering switches with locking mechanism, release the locks. If they are soldered without releasing the locks, the soldering heat may deform the locking mechanism. 8. Be sure to release the locks before removing the knobs. Otherwise, the locking mechanism may be broken. 9. Be sure to use the switch with forced travel positioned as close to the total travel as possible. Push Type 10. Tighten the mounting screws by applying the specified torque. Tightening with a larger torque than the specified will result in malfunction or breakage of screws. 11. Corrosive gas if generated by peripheral parts of a set, malfunction such as imperfect contact may occur. Thorough investigation shall be required beforehand. 12. Storage Rocker Type Store the products as delivered at normal temperature and humidity, out of direct sunlight and away from corrosive gases. Use them as soon as possible and no later than six months after delivery. Once the seal is broken, use them as soon as possible. Slide Type Power Switches Safety Standards 1. Safety Standards Outline Rotary Type Safety standards are established by a country or an organization representing it to protect general users from electrical shock and fire hazards. It establishes standards for electrical devices and components. For electrical equipment manufacturers, utilizing switches that have been safety-approved ensures the safety of the switch. The use of a safety-approved switch also simplifies at least one part of the process of obtaining certification by safety testing. 2. Major Safety Standards Electrical Appliance and Material Safety Law (1) The conventional [Electrical Appliance and Material Control Law] has changed to [Electrical Appliance and Material Safety Law] and has been enforced since April 1, 2001. Electrical appliances are categorized into special electric appliances and parts(formerly Class A)and Electrical appliances other than the special electric appliances(formerly Class B). Special electric appliances are required to receive goodness of fit test at a certified test agency and to store the certificate. Also, penal provisions have been reinforced. UL (2) (Underwriters Laboratories Inc.) Underwriters Laboratories Inc.(UL)is the American safety approving organization. Its purpose is to ensure consumer safety and protect them from fire hazards. State law requires that equipment to be exported to the United States utilize UL approved power switches or power switches meeting UL standards and capable of passing UL tests. 176