mpu30 3 0 W M e d i c a l G r ade Desktop Switching Power Adapters series Universal 90-264VAC Input UL/cUL60601-1, EN60601-1 Regulated Outputs 4000V Isolation IEC320-C14 Input 2.56”W x 4.65”L x1.54”H Model Number Output Voltage Output Amps RegulationMax. Output Watts Output Connector SINGLE OUTPUT MPU30-101 MPU30-102 MPU30-103 MPU30-104 MPU30-105 MPU30-106 MPU30-107 MPU30-108 MPU30-109 MPU30-110 3.3 5 6 10 12 15 18 24 30 36 6.06 5 4.16 3 2.5 2 1.66 1.25 1 0.83 5% 5% 5% 4% 3% 3% 3% 2% 2% 2% Coaxial Coaxial Coaxial Coaxial Coaxial Coaxial Coaxial Coaxial Coaxial Coaxial WWW.ASTRODYNE.COM 20W 25W 25W 30W 30W 30W 30W 30W 30W 30W ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 mpu30 3 0 W M e d i c a l G r ade Desktop Switching Power Adapters series Universal 90-264VAC Input UL/cUL60601-1, EN60601-1 Regulated Outputs 4000V Isolation IEC320-C14 Input 2.56”W x 4.65”L x1.54”H Model Number Output Voltage Output Amps RegulationMax. Output Watts Output Connector DUAL OUTPUT MPU30-200 MPU30-201 MPU30-202 MPU30-203 MPU30-204 MPU30-209 MPU30-210 MPU30-215 3.3/12 5/12 5/15 5/24 3.3/5 +/-12 +/-15 5/-24 3/1.3 3/1.3 3/1 3/0.7 3/1.6 2/0.5 1.5/0.5 2.5/1 7/5% 5/5% 5/6% 5/5% 7/5% 5/5% 5/5% 5/5% 25W 30W 30W 30W 17.9W 30W 30W 30W DIN DIN DIN DIN DIN DIN DIN DIN TRIPLE OUTPUT MPU30-301 MPU30-302 MPU30-303 MPU30-304 MPU30-305 MPU30-306 5/12/-5 5/12/-12 5/15/-15 5,+/-24 5/24/-12 3.3/12/-5 2.5/1.3/0.5 2.5/1/0.5 2.5/1/0.5 3/1/0.5 2.5/1/0.5 2.5/1.1/0.5 5/5/10% 5/5/10% 5/5/10% 5/5/10% 5/5/10% 7/5/10% 25W 30W 30W 30W 30W 25W DIN DIN DIN DIN DIN DIN WWW.ASTRODYNE.COM ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 mpu30 3 0 W M e d i c a l G r ade Desktop Switching Power Adapters PHYSICAL SPECIFICATIONS INPUT SPECIFICATIONS Input Voltage Range Frequency Range Leakage Current Input Current Lowline Input Current Highline Leakage Current Inrush Current Lowline Inrush Current Highline 90-264 VAC 47-63 Hz 0.1mA typ. @ 240VAC 0.9A 0.34A 0.1mA 15A max. 30A max. OUTPUT SPECIFICATIONS Voltage and Current Load Regulation Line Regulation Ripple/Noise Hold Up Time Start Up Time Over Voltage Protection Over Current Protection Transient Response (FL-1/2L) Temperature Coefficient series See Selection Charts See Selection Charts ± 0.5%, typ (1% Max.) 0.5% Pk-Pk, typ (1% Max.) 12mS min. at 110VAC Input 1.5S typ. (2S max.) 112-132% 110-150% 4mS ±0.04%/°C, typ. Size Construction Weight 4.65”L x 2.56”W x 1.54”H Desktop Style 16.22oz (460g) ENVIRONMENTAL SPECIFICATIONS Oper. Temperature Storage Temperature Relative Humidity EMI 0 to +70°C See Derate Curve -40 to +85°C * 5 to + 95%, non-cond * 220VAC in: CISPR-11B 110VAC in: FCC18B OUTPUT DERATING CURVE GENERAL SPECIFICATIONS Isolation Isolation Resistance Efficiency Safety I/P-O/P: 4000VAC I/P-GND: 2000VAC O/P-GND: 500VAC 50MΩ 83% typ. UL60601-1, EN60601-1 All specifications are typical at nominal input, full load, and 25°C unless otherwise noted * These are stress ratings. Exposure of the devices to any of these conditions may adversely affect long term reliability. Proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. WWW.ASTRODYNE.COM Astrodyne products are not authorized or warranteed for use as critical components in life support systems, equipment used in hazardous environments, nuclear controls systems, or other mission-critical applications. ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458 mpu30 3 0 W M e d i c a l G r ade Desktop Switching Power Adapters series Input Connection MECHANICAL DIMENSIONS Output Cord Length 72” typ. H W DC Output Connections Coaxial Plug (Single Output Models) -Vout +Vout 5.5mm outer diameter 2.1mm inner diameter, female 11mm length, center “+” DIN (Multi-Output Models) 5 Pin DIN 1 3 4 5 2 WWW.ASTRODYNE.COM 1. COM 2. COM 3. Output #1 4. Output #3 (Triples, N.C. Otherwise) 5. Output #2 ASTRODYNE USA: 1-800-823-8082 ASTRODYNE PACIFIC: 886-2-26983458