TBC Series HRC6000 Medical Grade

TBC Series
HRC6000 Medical Grade
The TBC HRC6000 Medical Grade series is the next generation
of our internally qualified medical grade tantalum capacitors.
These components are screened using our newly designed QProcess to effectively remove components that may experience
parametric shifts through customer processing or display
instability through life testing.
Due to the deficiencies of Weibull grading and its tendency to
Burn-In potentially unstable units, this Q-Process utilizes a
Product Level Designation system based on a simulated production routine
performed on a sample from the population. Once that is completed a calculation is
done based on the performance of the sample which can take into account the
application conditions of the end customer. This system also allows for derating
recommendations to be relaxed as illustrated by the section below.
These components are manufactured and tested in the AVX Biddeford Maine
factory which is ISO 13485 certified. For more information on this process or to
request a specific rating please contact the factory.
CASE DIMENSIONS: millimeters (inches)
W
POLARITY BAND NOT TO
EXCEED 75% OF BODY
Case EIA
Code Code
L
R
0805
Length (L)
Width (W)
Height (H)
Term. Width (P) min.
+0.25
2.00 -0.15
+0.010
(0.079 -0.006 )
+0.20
1.35 -0.10
+0.008
(0.053 -0.004 )
+0.20
1.35 -0.10
+0.008
(0.053 -0.004 )
0.15
(0.006)
H
P
P
TECHNICAL SPECIFICATIONS
Technical Data:
Capacitance Range:
Capacitance Tolerance:
Rated Voltage (VR)
Category Voltage (VC)
Temperature Range:
⬉ +85°C:
⬉ +125°C:
Unless otherwise specified, all technical data relate to an ambient temperature of +25°C
10 μF
±5%; ±10%; ±20%
10
6.7
-55°C to +125°C
APRIL 2014
■ 63
TBC Series
HRC6000 Medical Grade
CAPACITANCE AND RATED VOLTAGE, VR (VOLTAGE CODE) RANGE
(LETTER DENOTES CASE SIZE)
μF
3.3
4.7
6.8
10
15
22
Capacitance
Code
335
475
685
106
156
226
4V
6V
Rated Voltage
16V
10V
20V
25V
35V
40V
R
HOW TO ORDER
TBC R
Type
Case
Size
106
*
010
C
Capacitance Capacitance
Voltage
ESR
Code
Tolerance
Code
C = Std ESR
pF code:
J = ±5%
010 = 10Vdc
1st two digits
K = ±10%
represent
M = ±20%
significant
figures 3rd
digit represents
multiplier
(number of
zeros to follow)
*Contact factory for AVX HRC6000 Medical Grade SCD details.
64 ■ APRIL 2014
L
@
Packaging
B = Bulk
R = 7" T&R
W = Waffle
Inspection Level
L = Group A
Reliability Grade
Product Level
Designator:
P = 0.1%/1000 hrs.
60% conf.
R = 0.01%/1000 hrs.
60% conf.
6
^
++
Qualification Termination Finish
Level
0 = Solder Fused
6 = HRC6000 9 = Gold Plated
7 = 100% Matte Tin
Surge Test
Option
00 = None
23 = 10 Cycles, +25ºC
24 = 10 Cycles,
-55ºC & +85ºC
Not RoHS Compliant
LEAD-FREE COMPATIBLE
COMPONENT
For RoHS compliant products,
please select correct termination style.
TBC Series
HRC6000 Medical Grade
RATING & PART
NUMBER REFERENCE
AVX HRC6000 P/N
Case
TBCR106*010C□L@6^++
R
Cap
DC Rated
ESR
@ 120Hz Voltage @ 100kHz
μF @
25ºC
10
V@
+85ºC
10
Ohms
@ +25ºC
6
Parametric Specifications by Rating
DCL max
DF max
+25°C
+85°C
+125°C
+25°C
+85/125°C
-55°C
Power
Dissipation
(μA)
(μA)
(μA)
(%)
(%)
(%)
W
0.250
2.500
3.000
8
16
12
0.045
Typical Ripple Data by Rating
25ºC
85ºC
125ºC
25ºC
85ºC
125ºC
Ripple
Ripple
Ripple
Ripple
Ripple
Ripple
Current Current Current Voltage Voltage
Voltage
A
A
A
V
V
V
(100kHz) (100kHz) (100kHz) (100kHz) (100kHz) (100kHz)
0.087
0.078
0.035
0.014
0.013
0.006
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes.
NOTE: AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
HRC6000 DERATING GUIDELINES
Due to our new Q-Process test procedures the need for a
typical 50% derating of the capacitors rated voltage in
application can be relaxed. Below is a table outlining some of
the common applications where these components are
utilized along with appropriate derating recommendations.
When determining the appropriate capacitor voltage rating to
utilize, the application voltage is determined by the maximum
D.C. voltage with the addition of any A.C. ripple voltage that
may be present.
Recommended Derating
20%
0%
0%
0%
Application
Filtering
Pacing
Hold-Up
Charging
APRIL 2014