0RFB-S0T280

ISOLATED DC/DC CONVERTERS
48 Vdc Input
28 Vdc /25 A Output
0RFB-S0T280
•
RoHS Compliant
•
Isolated
Rev.C
Output Over-Voltage Latch Off
•
Fixed Frequency (300 kHz)
•
SCP/OCP (Hiccup Mode)
•
High Efficiency
•
Isolation Remote On/Off
•
High Power Density
•
Auxiliary Bias Power
•
Low Cost
•
•
Input Over-Voltage Lockout
•
Input Under-Voltage Lockout
•
Basic Isolation
•
Over Temperature Protection
Lockout
Inverter Operation Good
(Power Good)
•
Heatsink for Extended Operation
(Option)
•
Parallel Operation Using Forced
Current Sharing (Option)
Description
The 0RFB-S0T280 is an isolated dc/dc converter that operates from a nominal 48 Vdc source. These units will
provide up to 700 W of output power from a nominal 48 Vdc input. This unit is designed to be highly efficient and
low cost. Features include remote on/off, over current protection, input under-voltage and over-voltage lockout.
This converter is provided in an industry standard full brick package.
Part Selection
Output
Voltage
Input Voltage
Max. Output
Current
Max. Output
Power
Typical
Efficiency
Model Number
28 Vdc
48 Vdc
25 A
700 W
91%
0RFB-S0T280
Notes: 1. Add “G” suffix at the end of the model number to indicate Tray Packaging.
2. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.
Absolute Maximum Ratings
Parameter
Min
Typ
Max
Input Voltage
-0.3 V
-
80 V
Remote On/Off
-10 mA
-
5 mA
-
-
1500 V
Ambient Temperature
-40 °C
-
100 °C
Storage Temperature
-55 °C
-
125 °C
I/O isolation voltage
Notes
It's the temperature of baseplate.
Note: All specifications are typical at 25 °C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input
28 Vdc /25 A Output
Input Specifications
Parameter
Min
Typ
Max
36 V
48 V
76 V
Input Current (no load)
-
100 mA
150 mA
Input Current (full load)
-
-
23 A
Remote Off Input Current
-
40 mA
60 mA
Input Reflected Ripple Current
(pk-pk)
-
30 mA
-
Input Reflected Ripple Current
(rms)
-
10 mA
-
I t Inrush Current Transient
-
-
1A s
Turn-on Voltage Threshold
33 V
34.5 V
35.5 V
Turn-off Voltage Threshold
31 V
33 V
34 V
Input Over Voltage Lockout
76 V
78 V
80 V
Input Voltage
2
Notes
With simulated source impedance of
15 uH, 5 Hz to 20 MHz; use 2* 220
uF/100 V electrolytic capacitor with
ESR = 1 ohm max at 200 kHz
2
Note: All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
Output Specifications
Parameter
Min
Typ
Max
27.72 V
28.00 V
28.28 V
Load Regulation
-
-
56 mV
Line Regulation
-
-
56 mV
Regulation Over Temperature
(-40deg.C-85deg.C)
-
-
300 mV
0A
-
25 A
Output Voltage Trim Range
16.8 V
-
32.2 V
Output DC Current Limit
26.25 A
30 A
35 A
Ripple and Noise (rms)
-
-
80 mV
Ripple and Noise (pk-pk)
-
-
280 mV
20 mS
40 mS
80 mS
-
0%
2%
0 uF
-
5000 uF
Output Voltage Set Point
Output Current Range
Turn on Time
Overshoot at Turn on
Output Capacitance
Notes
Vin=48 V, full load
Over all load, line and temperature
conditions.
Transient Response
50% ~ 75%
Max Load
75% ~ 50%
Max Load
Overshoot
-
800 mV
1200 mV
-
500 uS
800 uS
Overshoot
-
800 mV
1200 mV
Settling Time
-
500 uS
800 uS
Settling Time
VO=28 V
di/dt=0.1A/us, Vin=48 Vdc,
with a 1 µF ceramic
capacitor and a 470 uF low
ESR aluminum load
capacitor at output, Ta=25
°C.
Note: All specifications are typical at nominal input, full load at 25 °C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input
28 Vdc /25 A Output
General Specifications
Parameter
Min
Typ
Max
88%
91%
-
Switching Frequency
-
300 kHz
-
Isolation Capacitance
-
1500 pF
-
10 M Ohm
-
-
Input to Output
-
-
1500 V
Input to Case
-
-
1500 V
-
-
500 V
7V
-
10 V
IOG Pin Max Applied Voltage
-
-
35 V
Remote Sense compensation
0V
Over Temperature Protection
-
105 ℃
-
33 V
-
35.8 V
Efficiency
Isolation Resistance
Output to Case
1
Auxiliary Output Voltage
2
Over Voltage Protection
Notes
Vin=48 V, full load
2V
It's the temperature of baseplate.
Temperature Limits for Power Derating Curves
Semiconductor Junction
Temperature
-
-
120 ℃
PCB Board Temperature
-
-
125 ℃
Transformer Temperature
-
-
125 ℃
MTBF
Calculated Per Bell Core SR-332
(Vin=48 V, Io=normal , Ta = 25 °C)
TBD
Dimensions
Inches
millimeters
Weight
4.60 x 2.40 x 0.50
116.8 x 61.0 x 12.69
-
150 g
-
Notes: 1. Aux pin source current <=20 mA, ground for the AUX terminal is -S terminal.
2. The signal is low when inverter is normally operating and HIGH when inverter stops or operating
abnormally, maximum sink current is 5 mA.
All specifications are typical at 25 °C unless otherwise stated.
Control Specifications
Parameter
Min
Typ
Max
1 mA
-
5 mA
-10 mA
-
0 mA
Notes
Remote On/Off
The Converter ON
Isink
The Converter Off
Note: +ON/OFF, -ON/OFF terminal, Isolation withstand voltage to input or output or baseplate:500 Vdc.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input
28 Vdc /25 A Output
Output Trim Equations
1. Equations for calculating the trim resistor are shown below. The Trim Down resistor should be connected
between the Trim pin and Sense(-) pin. The Trim Up resistor should be connected between the Trim pin and the
Sense(+) pin. Only one of the resistors should be used for any given application.
Sense(+)
Rtrimdown =
600
− 6 [k Ω ]
delta
Module
Trim
Rtrimdown
Sense(-)
(100 + delta) ⋅Vo ⋅ 6 − 600
Rtrimup =
− 6[ k Ω]
delta
Sense(+)
Rtrimup
Module
Trim
Sense(-)
Note:
delta =
(Vo _ req − Vo ) × 100 [% ]
Vo
Vo_req=Desired(trimmed) output voltage[V], Output voltage Vo=28 V
2. Output Voltage Adjustement by applying external voltage:
Vout=Trim Terminal Voltage X Nominal Output Volgage.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input
28 Vdc /25 A Output
Efficiency Data
EFFICIENCY
95.0%
90.0%
36 V
85.0%
48 V
76 V
80.0%
75.0%
70.0%
2.50
6.25
12.50
18.75
25.0
OUTPUT CURRENT(A)
Thermal Derating Curve
Notes: 1. VIN=48 V, with maximum junction temperature of semiconductors derated to 120C.
2. Custom need to add extended heatsink to keep the baseplate temperature.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input
28 Vdc /25 A Output
Ripple and Noise Waveforms
Ripple and noise at no load, 36 Vdc input
Ripple and noise at full load, 36 Vdc input
Ripple and noise at no load, 48 Vdc input
Ripple and noise at full load, 48 Vdc input
Ripple and noise at no load, 76 Vdc input
Ripple and noise at full load, 76 Vdc input
Note: Ripple and noise at 0-20MHz BW, with a 10 uF and a 1 uF ceramic cap, 28 Vdc output, Ta=25 deg C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input
28 Vdc /25 A Output
Transients Response Waveforms
50%-75% Load Transients at Vin=36 V
75%-50% Load Transients at Vin=36 V
50%-75% Load Transients at Vin=48 V
75%-50% Load Transients at Vin=48 V
50%-75% Load Transients at Vin=76 V
75%-50% Load Transients at Vin=76 V
Note: Transient response with external electrolytic cap 4700 uF, Ta=25 deg C.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input
28 Vdc /25 A Output
Mechanical Outline
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/DC CONVERTERS
48 Vdc Input
28 Vdc /25 A Output
Mechanical Outline (continued)
Pin Connections
Pin
Function
Pin Size
Pin
Function
Pin Size
1
Vin(-)
2
0.079’’
9
Vout(-)
0.079’’
Vin(+)
0.079’’
10
3
Vout(-)
0.079’’
On/Off(-)
0.039’’
11
SENSE(-)
0.039’’
4
On/Off(+)
0.039’’
12
SENSE(+)
0.039’’
5
Vout(+)
0.079’’
13
TRIM
0.039’’
6
Vout(+)
0.079’’
14
PC
0.039’’
7
Vout(+)
0.079’’
15
IOG
0.039’’
8
Vout(-)
0.079’’
16
AUX
0.039’’
RoHS Compliance
Complies with the European Directive 2002/95/EC, calling for the elimination of lead and
other hazardous substances from electronic products.
©2008 Bel Fuse Inc. Specifications subject to change without notice. 050808
CORPORATE
FAR EAST
EUROPE
Bel Fuse Inc.
206 Van Vorst Street
Jersey City, NJ 07302
Tel 201-432-0463
Fax 201-432-9542
www.belfuse.com
Bel Fuse Ltd.
8F/ 8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel 852-2328-5515
Fax 852-2352-3706
www.belfuse.com
Bel Fuse Europe Ltd.
Preston Technology Management Centre
Marsh Lane, Suite G7, Preston
Lancashire, PR1 8UD, U.K.
Tel 44-1772-556601
Fax 44-1772-888366
www.belfuse.com