View Infographic - Emerson Network Power

INTEGRATED SYSTEM OPTIMIZES EFFICIENCY
Cooling equipment accounts for as much
as 40% of data center operating costs. 1
The Liebert PDX direct expansion cooling system each component operates at the industry's highest
efficiency, and the lowest total cost of ownership.
Medium and large data centers
need to reduce costs while
Liebert iCOM™
Thermal System Controls
Intelligence for optimized operation
The Liebert PDX
indoor computer room air
conditioning (CRAC) unit
World's most efficient DX
cooling system
preserving availability.
The Liebert® PDX is the most energy-efficient
room-based direct expansion (DX) cooling
system in the industry. Up to 70% more
efficient than alternative DX solutions, the
system improves thermal management and
control, while drastically cutting energy costs
and lowering pPUE.
The Liebert EconoPhase™
pumped refrigerant economizer
For enhanced energy savings
The Liebert MC™
micro-channel condenser
Intelligent, high efficiency condensers
STEPS TO AN EFFICIENT DATA CENTER
SHATTER INDUSTRY
STANDARDS
STOP UNNECESSARY
COOLING
Why waste energy that’s not needed?
Energy Efficiency (SCOP)
Even without economization, the Liebert PDX
operates at higher efficiency than other technologies, with
600% higher
than ASHRAE
minimum
ASHRAE 90.1
Minimum
variable speed electronically commutated (EC) plug fans, Digital Scroll™
compressors, electronic expansive valves and Liebert iCOM controls that
vary cooling and airflow to match fluctuating I.T. requirements.
The result? A 23% reduction in power consumption.
Cooling accounts for 40% of total energy use for the average
data center – about 2.96 billion in cooling costs. 4
Liebert PDX - PX120
A 23% reduction would
save
approximately € 602,400,000 -
The Liebert PDX operating in EconoPhase™ mode is up to 600% more
efficient during cold ambient hours than the ASHRAE 90.1 minimum
requirements for cooling equipment efficiency2, and capable of
achieving a money-saving cooling
that’s enough to buy enough smart phone
USB charging cable to stretch from Buffalo,
New York to Beijing, China… and back! 5 6
pPUE as low as 1.05.
REDUCE OR ELIMINATE
COMPRESSOR RUNTIME
PUT MONEY BACK IN
YOUR POCKET
These improvements can result in
The Liebert EconoPhase pumped refrigerant
economizer automatically switches to
economizer operation to reduce or
eliminate compressor run time during
periods of lower outdoor temperature.
€ 177,000 or more,
energy savings of
based on geographical location
and EconoPhase usage. 7
THAT’S ENOUGH TO BUY AN
ITALIAN SPORTS CAR. 8
System energy consumption
is reduced by up to 70%. 3
Plus: No water. No water treatment.
No outside air contamination.
SOURCES
LEARN
MORE
For more information on the Liebert PDX, visit
emersonnetworkpower.eu/Liebert-PDX
or contact your local sales representative.
1
Energy Logic 2.0: New Strategies for Cutting Data Center energy Costs and
5
Cost and length of smart phone USB charging cable:
http://store.apple.com/us/product/MD818ZM/A/lightning-to-usb-cable
Boosting Capacity, http://www.emersonnetworkpower.com/en-US/Latest-Thinking/
Google Maps, www.googlemaps.com
EDC/Documents/White%20Paper/IS03947_2012_EnergyLogic_FIN.pdf
6
2
ASHRAE 90.1 minimum standards for at full-load 35°C outdoor ambient conditions
7
http://emersonnetworkpower.eu/Liebert-PDX
3
Compared to glycol-based cooling systems with water-side economizers
8
http://www.motortrend.com/new_cars/01/lamborghini/
4
Energy Star’s Report to Congress on Server and Data Center Efficiency
Opportunities, http://www.energystar.gov/index.cfm?c=prod_
development.server efficiency#principles