AS3911B NFC Initiator / HF Reader IC General Description The AS3911B is a highly integrated NFC Initiator / HF Reader IC. It includes the analog front end (AFE) and a highly integrated data framing system for ISO 18092 (NFCIP-1) initiator, ISO 18092 (NFCIP-1) active target, ISO 14443 A and B reader (including high bit rates) and FeliCa™ reader. Implementation of other standard and custom protocols like MIFARE™ Classic 1 is possible through using the AFE and implementing framing in the external microcontroller (Stream and Transparent modes). Compared with concurrent NFC devices designed with the mobile phone in mind, the AS3911B is positioned perfectly for the infrastructure side of the NFC system, where users need optimal RF performance and flexibility combined with low power. With ams’ unique Automatic Antenna Tuning technology, the device is optimized for applications with directly driven antennas. The AS3911B is alone in the domain of HF Reader ICs in that it contains two differential low impedance (1Ω) antenna drivers. The AS3911B includes several features, which make it incomparable for low power applications. It contains a low power capacitive sensor, which can be used to detect the presence of a card without switching on the reader field. Additionally, the presence of a card can also be detected by performing a measurement of amplitude or phase of signal on antenna LC tank and comparing it to stored reference. It also contains a low power RC oscillator and wake-up timer, which can be used to wake the system after a defined time period and check for the presence of a tag using one or more techniques of low power detection of card presence (capacitive, phase or amplitude). The AS3911B is designed to operate from a wide power supply range from 2.4 V to 5.5 V; peripheral interface IO pins support power supply range from 1.65 V to 5.5 V. Ordering Information and Content Guide appear at end of datasheet. 1. MIFARE™ and MIFARE™ Classic are trademarks of NXP B.V. ams Datasheet [v1-13] 2015-Jun-18 Page 1 Document Feedback AS3911B − General Description Key Benefits & Features The benefits and features of AS3911B, NFC Initiator / HF Reader IC are listed below: Figure 1: Added Value of Using AS3911B Benefits Features • NFC Active P2P support • ISO 18092 (NFCIP-1) Active P2P • ISO14443 A, B and FeliCa (TM) • High data transfer with ASK VHBR and fast SPI • Support of VHBR (3.4 Mbit/s PICC to PCD framing, 6.8 Mbit/s AFE and PCD to PICC framing) • 6μA consumption at sensing every 100ms • Capacitive sensing - Wake-up • Antenna tuning on the fly • Automatic Antenna Tuning system providing tuning of antenna LC tank • Stable modulation index at ASK modulation • Automatic modulation index adjustment • No communication holes • AM and PM (I/Q) demodulator channels with automatic selection • High output power for EMVCo readers • Up to 1 W in case of differential output • High Rx sensitivity • User selectable and automatic gain control • Allows implementation of custom framings • Transparent and Stream modes to implement MIFARE™ Classic compliant or other custom protocols • Multi Antenna support • Possibility of driving two antennas in single ended mode • Smaller Oscillator size • Oscillator input capable of operating with 13.56 MHz or 27.12 MHz crystal with fast start-up • Easy FIFO handling • 10 M bit SPI with 96 bytes FIFO • Battery powered operation • Wide supply voltage range from 2.4 V to 5.5 V • Fits Temperature requirements for various applications • Wide temperature range: -40°C to 125°C • Small outline, good cooling through exposed pad • QFN 5x5 LD32 package Page 2 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − General Description Applications The AS3911B is suitable for a wide range of applications including: • EMV Payment • Access Control • NFC Infrastructure • Ticketing Block Diagram The functional blocks of this device for reference are shown below: Figure 2: AS3911B Block Diagram VDD_IO XTO XTI XTAL Oscillator VDD Regulators POR&&Bias Bias POR LOGIC Transmitter FIFO SPI IRQ Level Shifters Control Logic MCU_CLK RFO 1 RFO 2 A/D A/D Converter Converter Phase & Amplitude Detector SPI Interface Receiver RFI1 RFI2 TRIMx Framing RC Oscillator External Field Detector Wake-up Timer AS3911B Capacitor Sensor ams Datasheet [v1-13] 2015-Jun-18 CSI CSO Page 3 Document Feedback AS3911B − Pin Assignment Pin Assignment The AS3911B pin and pad assignments are described below. SCLK MOSI MISO MCU_CLK IRQ VSN_A CSI AS3911B Pin Assignment: This figure shows the pin assignment and location viewed from top. /SS Figure 3: QFN Pin Diagram 32 31 30 29 28 27 26 25 VDD_IO 1 24 AGD CSO 2 23 RFI2 VSP_D 3 22 RFI1 XTO 4 21 VSS XTI 5 20 TRIM2_0 VSN_D 6 19 TRIM1_0 VSP_A 7 18 TRIM2_1 VDD 8 17 TRIM1_1 AS3911B RFO2 VSN_RF 13 14 15 16 TRIM2_2 RFO1 12 TRIM1_2 11 TRIM2_3 10 TRIM1_3 9 VSP_RF Exposed Pad 37 36 35 34 33 32 31 MISO MCU_CLK IRQ VSN_A VSN_A CSI 1 VDD_IO 38 MOSI 39 SCLK AS3911B Pad Assignment: This figure shows the pad assignment and location viewed from top. /SS Figure 4: Die Pad Diagram 2 CSO AGD 30 RFI2 29 3 VSP_D RFI1 28 AS3911B die (Top view) 4 XTO 5 XTI VSS 27 VSS_TRIM 26 6 VSN_D TRIM2_0 25 TRIM1_0 24 Page 4 Document Feedback VSN_RF TRIM1_3 TRIM2_3 TRIM1_2 10 11 12 13 14 15 16 17 18 19 20 VSN_RF RFO2 RFO2 RFO1 RFO1 VDD VSP_RF VDD 9 VSP_RF 8 TRIM2_2 TRIM2_1 23 7 VSP_A TRIM1_1 22 21 ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Pin Assignment Figure 5: Pin and Pad Description Pin Number Pin Name Pin Type 1 VDD_IO Supply pad 2 2 CSO 3 3 VSP_D 4 4 XTO 5 5 XTI Analog input / Digital input 6 6 VSN_D Supply pad 7 7 VSP_A Analog output 8 8, 9 VDD Supply pad 9 10, 11 VSP_RF 10 12, 13 RFO1 11 14, 15 RFO2 12 16, 17 VSN_RF 13 18 TRIM1_3 14 19 TRIM2_3 15 20 TRIM1_2 16 21 TRIM2_2 17 22 TRIM1_1 18 23 TRIM2_1 19 24 TRIM1_0 20 25 TRIM2_0 NA 26 21 QFN Die 1 Description Positive supply for peripheral communication Capacitor sensor output Analog output Digital supply regulator output Xtal oscillator output Xtal oscillator input Digital ground Analog supply regulator output External positive supply Supply regulator output for antenna drivers Analog output Antenna driver output Supply pad Ground of antenna drivers Analog I/O Input to trim antenna resonant circuit VSS_TRIM Supply pad Ground, die substrate potential 27 VSS Supply pad Ground, die substrate potential 22 28 RFI1 23 29 RFI2 24 30 AGD Analog I/O 25 31 CSI Analog input Analog input ams Datasheet [v1-13] 2015-Jun-18 Receiver input Analog reference voltage Capacitor sensor input Page 5 Document Feedback AS3911B − Pin Assignment Pin Number Pin Name Pin Type 32, 33 VSN_A Supply pad 34 IRQ QFN Die 26 27 Description Analog ground Interrupt request output Digital output 28 35 MCU_CLK 29 36 MISO 30 37 MOSI 31 38 SCLK 32 39 /SS # NA VSS Page 6 Document Feedback Microcontroller clock output Digital output / tristate Serial Peripheral Interface data output Serial Peripheral Interface data input Digital input Serial Peripheral Interface clock Serial Peripheral Interface enable (active low) Exposed Pad Ground, die substract potential, connect to VSS on PCB ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Absolute Maximum Ratings Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only. Functional operation of the device at these or any other conditions beyond those indicated under Operating Conditions is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Absolute Maximum Ratings Figure 6: Absolute Maximum Ratings Symbol Parameter Min Max Unit Comments Electrical Parameters VDD DC supply voltage -0.5 6.0 V VDD_IO DC_IO supply voltage -0.5 6.0 V VINTRIM Input pin voltage TRIM pins -0.5 25.0 V VIN Input pin voltage for peripheral communication pins -0.5 6.5 V VINA Input pin voltage for analog pins -0.5 6.0 V Iscr Input current (latch-up immunity) -100 100 mA 0 600 mA Ioutmax Drive capability of output driver Norm: JEDEC 78 Electrostatic Discharge ESD ±2 kV Standard MIL-STD-883-J-3015.9 (Human Body Model) ±500 V Valid for Trimx.x pins (pins 13 - 20) Electrostatic discharge Temperature Ranges and Storage Conditions Tstrg Storage temperature Tbody Package body temperature RHNC Relative Humidity non-condensing MSL Moisture Sensitivity Level ams Datasheet [v1-13] 2015-Jun-18 -55 125 5 3 °C 260 °C 85 % Norm: IPC/JEDEC J-STD-020. The reflow peak soldering temperature (body temperature) is specified according IPC/JEDEC J-STD-020 “Moisture/Reflow Sensitivity Classification for Non-hermetic Solid State Surface Mount Devices.” The lead finish for Pb-free leaded packages is matte tin (100% Sn). Represents a max. floor life time of 168h Page 7 Document Feedback AS3911B − Electrical Characteristics All limits are guaranteed. The parameters with min and max values are guaranteed with production tests or SQC (Statistical Quality Control) methods. Electrical Characteristics Operating Conditions All defined tolerances for external components in this specification need to be assured over the whole operation condition range and also over lifetime. Figure 7: Operating Conditions Symbol Parameter Min Max Unit VDD Positive supply voltage 2.4 5.5 V VDD_IO Peripheral communication supply voltage 1.65 5.5 V VSS Negative supply voltage 0 0 V 20 V 125 °C VINTRIM TJUN VRFI_A RFO Input pin voltage TRIM pins Junction temperature -40 RFI input amplitude 150 m 3 Vpp 0 500 mA Driver current Comments In case power supply is lower than 2.6 V, PSSR cannot be improved using internal regulators (minimum regulated voltage is 2.4 V) Minimum RFI input signal definition is meant for NFC receive mode. In HF reader mode and NFC transmit mode, the recommended signal level is 2.5 Vpp DC/AC Characteristics for Digital Inputs and Outputs CMOS Inputs: Valid for input pins /SS, MOSI, and SCLK Figure 8: CMOS Inputs Symbol Parameter Min Max Unit VIH High level input voltage 0.7 * VDD_IO VDD_IO V VIL Low level input voltage VSS 0.3 * VDD_IO V -1 1 μA ILEAK Page 8 Document Feedback Input leakage current ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Electrical Characteristics CMOS Outputs: Valid for output pins MISO, IRQ and MCU_CLK, io_18=0 (IO Configuration Register 2). Figure 9: CMOS Outputs Symbol Parameter Conditions Min ISOURCE/SINK = 1mA measured at VDDIO = 2.4V ISOURCE/SINK = 0.5mA measured at VDDIO = 1.65V Typ Max Unit 0.9 * VDD_IO VDD_IO V 0 0.1 * VDD_IO V 50 pF VOH High level output voltage VOL Low level output voltage CL Capacitive load 0 RO Output Resistance 0 250 550 Ω RPD Pull-down resistance pin MOSI 5 10 15 kΩ Pull-down can be enabled while MISO output is in tristate. The activation is controlled by register setting. Electrical Specification V DD= 3.3 V, Temperature 25°C unless noted otherwise. 3.3V supply mode, regulated voltages set to 3.4 V, 27.12 MHz Xtal connected to XTO and XTI. Figure 10: Electrical Specification Symbol IPD INFCT Parameter Supply current in Power-down mode Supply current in initial NFC Target mode ams Datasheet [v1-13] 2015-Jun-18 Min 0.2 2.2 Typ 0.7 3.5 Max 2 7 Unit Comments μA Register 00h set to 0Fh (no clock on MCU_CLK), register 01h set to 80h (3V supply mode), register 02hset to 00h register 03h set to 08h, other registers in default state. μA Register 00h set to 0Fh (no clock on MCU_CLK), register 01h set to 80h (3V supply mode), register 02hset to 00h register 03h set to 80h (enable NFC Target mode), other registers in default state. Page 9 Document Feedback AS3911B − Electrical Characteristics Symbol IWU ICS IRD IAL ILP Parameter Supply current in Wake-up mode Capacitive sensor supply current Supply current in Ready mode Supply current all active Supply current all active, low power receiver mode Page 10 Document Feedback Min 1.6 0.6 4 6.2 4.8 Typ 3.6 1.1 5.4 8.7 6.8 Max 8 2 7.5 12.5 10 Unit Comments μA Register 00h set to 0Fh (no clock on MCU_CLK), register 01h set to 80h (3V supply mode), register 02h set to 04h (enable Wake-up mode), register 03hset to 08h, register 31h set to 08h (100ms timeout, IRQ at every timeout), other registers in default state. mA Register 00h set to 0Fh (no clock on MCU_CLK), register 01h set to 80h (3 V supply mode), register 02h set to 00h, analog test mode 14, other registers in default state. mA Register 00h set to 0Fh (no clock on MCU_CLK), register 01h set to C0h (3 V supply mode, disable VSP_D), register 02h set to 80h, register 03h set to 08h, other registers in default state, short VSP_A and VSP_D. mA Register 00h set to 0Fh, register 01h set to C0h (3V supply mode, disable VSP_D), register 02h set to E8h (one channel Rx, enable Tx), register 03h set to 08, register 0Bhset to 00, register 27h set to FF (all RFO segments disabled), other registers in default state, short VSP_A and VSP_D. mA Register 00h set to 0Fh, register 01h set to C0h (3V supply mode, disable VSP_D), register 02h set to E8h (one channel Rx, enable Tx), register 03h set to 08, register 0Bh set to 80 (low power mode), register 27h set to FF (all RFO segments disabled), other registers in default state, short VSP_A and VSP_D. ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Electrical Characteristics Symbol Parameter Min Typ Max Unit Comments RRFO RFO1 and RFO2 driver output resistance 0.25 0.6 1.8 Ω IRFO = 10 mA The following measurement procedure which cancels resistance of measurement setup is used: • All driver segments are switched on, resistance is measured, • All driver segments except the MSB segment are switched on, resistance is measured, • Difference between the two measurements is resistance of MSB segment, • Resistance of MSB segment multiplied by two is the value of RRFO. Zload Load impedance across RFO1 & RFO2 8 10 50 Ω Using Load impedance lower than minimum value can result in permanent damage of the IC VRFI RFI input sensitivity RRFI RFI input resistance VPOR Power on Reset Voltage VAGD VREG TOSC AGD voltage Regulated voltage Oscillator start-up time ams Datasheet [v1-13] 2015-Jun-18 mVrms 0.5 5 10 15 kΩ 1.31 1.5 1.75 V 1.4 2.80 0.65 1.5 3.0 0.7 1.6 3.32 10 fSUB=848 kHz, AM channel with peak detector input stage selected. V Register 00h set to 0Fh (no clock on MCU_CLK), register 01h set to C0h (3 V supply mode, disable VSP_D), register 02h set to 80h, register 03h set to 08h, other registers in default state, short VSP_A and VSP_D. V Manual regulator mode, regulated voltage set to 3.0 V, measured on pin VSP_RF: register 00h set to 0Fh, register 01h set to 80h (3V supply mode), register 02h set to E8h (one channel Rx, enable Tx), register 2Ah set to D8h. ms 13.56MHz or 27.12MHz crystal ESRMAX= 150 Ω max, load capacitance according to crystal specification, IRQ is issued once the oscillator frequency is stable. This parameter changes with ESRMAX parameter. Page 11 Document Feedback AS3911B − Typical Operating Characteristics Typical Operating Characteristics Thermal Resistance and Max. Power Dissipation Figure 11: TCASE vs. Power with Different Copper Area @ TAMB = 25°C TcasevsPowerQFN32withdifferentcopperarea.Tamb=25°C 100 90 0x0mm 80 10x10mm 20x20mm Tcase[°C] 70 30x30mm 60 40x40mm 50x50mm 50 60x60mm 70x70mm 40 30 20 0 0,5 1 1,5 PowerDissipation[W] 2 2,5 Figure 12: RthCA vs. Copper Area Rth_CA [K/W] vs Copper Area 100 90 80 Rth_CA [K/W] 70 60 50 40 30 20 10 0 0 Page 12 Document Feedback 10 20 30 Area [cm ^2] 40 50 60 ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Detailed Description Detailed Description Figure 13: Minimum Configuration with Single Sided Antenna Driving Including EMC Filter Figure 14: Minimum Configuration with Differential Antenna Driving Including EMC Filter +2.4 V ~ +5.5 V +1.65 V ~ +5.5 V VDD_IO μC VDD /SS MISO MOSI SCLK IRQ MCU_CLK AGD VSS VSP_A VSN_A VSP_D XTI VSN_D XTO TRIM1_x TRIM2_x AS3911B VSP_RF VSN_RF RF01 RF02 CSO CSI RFI1 RFI2 ams Datasheet [v1-13] 2015-Jun-18 Antenna Coil Page 13 Document Feedback AS3911B − Detailed Description Transmitter The transmitter incorporates drivers which drive external antenna through pins RFO1 and RFO2. Single sided and differential driving is possible. The transmitter block additionally contains a sub-block which modulates transmitted signal (OOK or configurable AM modulation). The AS3911B transmitter is intended to directly drive antennas (without 50 Ω cable, usually antenna is on the same PCB). Operation with 50 Ω cable is also possible, but in that case some of the advanced features are not possible. By applying FFh to the register 27h, the output driver are in tristate. Receiver The receiver detects transponder modulation superimposed on the 13.56MHz carrier signal. The receiver contains two receive chains (one for AM and another for PM demodulation) which are composed of a peak detector followed by two gain and filtering stages and a final digitizer stage. The filter characteristics are adjusted to optimize performance over different ISO modes and bit rates (sub-carrier frequencies from 212 kHz to 6.8 MHz are supported). The receiver chain inputs are RFI1 and RFI2 pins; output of digitizer stage is demodulated sub-carrier signal. The receiver chain incorporates several features which enable reliable operation in challenging phase and noise conditions. Phase and Amplitude Detector The phase detector is observing the phase difference between the transmitter output signals (RFO1 and RFO2) and the input signals RFI1 and RFI2. Signals RFI1 and RFI2 are proportional to the signal on the antenna LC tank. RFI1 and RFI2 signals are also used to run the self-mixer which generates output proportional to their amplitude. The phase detector and self-mixer blocks are used for several purposes: • PM demodulation by observing RFI1 and RFI2 phase variation (LF signal is fed to the Receiver) • Average phase difference between RFOx pins and RFIx pins is used to check antenna tuning • Output of mixer is used to measure amplitude of signal present on pins RFI1 and RFI2 A/D Converter The AS3911B contains a built in A/D Converter. Its input can be multiplexed from different sources and is used in several applications (measurement of RF amplitude and phase, calibration of modulation depth…). The result of A/D conversion is stored in a register which can be read through the SPI interface. Page 14 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Detailed Description Capacitive Sensor The Capacitive sensor is used to implement low power detection of transponder presence. Capacitive sensor performs measurement of capacitance between its two electrodes. Presence of an object (card, hand) changes the capacitance. During calibration the reference capacitance, which represents parasitic capacitance of environment is stored. In normal operation capacitance is periodically measured and compared to stored reference value. When the measured capacitance is larger than stored reference value (threshold value can be defined in a register) an interrupt is sent to external controller. External Field Detector The External Field Detector is a low power block which is used in NFC mode to detect presence of external RF field. It supports two different detection thresholds, Peer Detection Threshold and Collision Avoidance Threshold. Peer Detection Threshold is used in the NFCIP-1 target mode to detect presence of initiator field. It is also used in active communication initiator mode to detect activation of target field. Collision Avoidance Threshold is used to detect a presence of RF field during NFCIP-1 RF Collision Avoidance procedure. Quartz Crystal Oscillator The quartz crystal oscillator can operate with 13.56 MHz and 27.12 MHz crystals. At start-up the transconductance of the oscillator is increased to achieve fast start-up. Since the start-up time varies depending on crystal type, temperature and other parameters, the oscillator amplitude is observed and an interrupt is sent when stable operation is reached to inform the controller that the clock signal is stable and reader field can be switched on. The use of 27.12 MHz crystal is mandatory in case VHBR framing is used. It also provides a clock signal to the external microcontroller (MCU_CLK) according to setting in the control register. Power Supply Regulators Integrated power supply regulators ensure high power supply rejection of a complete reader system. In case PSRR of the reader system has to be improved, the command Adjust Regulators is sent. As result of this command, the power supply level of V DD is measured in maximum load conditions and the regulated voltage reference is set 250 mV below this measured level to assure a stable regulated supply. The resulting regulated voltage is stored in a register. It is also possible to define regulated voltage by writing a configuration register. In order to decouple any noise sources from different parts of IC there are three regulators integrated with separated external blocking capacitors (regulated voltage of all is the same in 3.3 V supply mode). One regulator is for the analog blocks, one for ams Datasheet [v1-13] 2015-Jun-18 Page 15 Document Feedback AS3911B − Detailed Description digital blocks, there is also a separate one for the antenna drivers. In case of low cost applications some (or all) regulators may not be used to save on external components. This block additionally generates a reference voltage for the analog processing (AGD - analog ground). This voltage also has an associated external buffer capacitor. POR and Bias This block contains the bias current and voltage generator which provides bias currents and reference voltages to all other blocks. It also incorporates a Power on Reset (POR) circuit which provides a reset at power-up and at low supply levels. RC Oscillator and Wake-up Timer The AS3911B includes several possibilities of low power detection of a card presence (capacitive sensor, phase measurement, amplitude measurement). RC oscillator and register configurable Wake-up timer are used to schedule periodic detection. When presence of a card is detected an interrupt is sent to controller. ISO14443 and NFCIP-1 Framing This block performs framing for receive and transmit according to the selected ISO mode and bit rate settings. In reception it takes demodulated sub-carrier signal from Receiver. It recognizes the SOF, EOF and data bits, performs parity and CRC check, organizes the received data in bytes and places them in the FIFO. During transmit, it operates inversely, it takes bytes from FIFO, generates parity and CRC bits, adds SOF and EOF and performs final encoding before passing modulation signal to transmitter. In Transparent mode, the framing and FIFO are bypassed, the digitized sub-carrier signal, which is Receiver output, is directly sent to MISO pin, signal applied to MOSI pin is directly used to modulate the transmitter. FIFO The AS3911B contains a 96 byte FIFO. Depending on the mode, it contains either data which has been received or data which is to be transmitted. Control Logic The control logic contains I/O registers which define operation of device. SPI Interface A 4-wire Serial Peripheral Interface (SPI) is used for communication between external microcontroller and the AS3911B. Page 16 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Application Information Operating Modes The AS3911B operating mode is defined by the contents of the Operation Control Register. At power-up all bits of the Operation Control Register are set to 0, the AS3911B is in Power-down mode. In this mode AFE static power consumption is minimized, only the POR and part of the bias are active, the regulators are transparent and are not operating. The SPI is still functional in this mode so all settings of ISO mode definition and configuration registers can be done. Control bit en (bit 7 of the Operation Control Register) is controlling the quartz crystal oscillator and regulators. When this bit is set, the device enters in Ready mode. In this mode the quartz crystal oscillator and regulators are enabled. An interrupt is sent to inform the microcontroller when the oscillator frequency is stable. Enable of Receiver and Transmitter are separated so it is possible to operate one without switching on the other (control bits rx_en and tx_en). In some cases this may be useful, in case the reader field has to be maintained and there is no transponder response expected receiver can be switched-off to save current. Another example is NFCIP-1 active communication receive mode in which RF field is generated by the initiator and only Receiver operates. Asserting the Operation Control Register bit wu while the other bits are set to 0 puts the AS3911B into the Wake-up mode which is used to perform low power detection of card presence. In this mode the low power RC oscillator and register configurable Wake-up timer are used to schedule periodic measurement(s). When a difference to the predefined reference is detected an interrupt is sent to wake-up the micro. Capacitive sensor, phase measurement and amplitude measurement are available. Transmitter The Transmitter contains two identical push-pull driver blocks connected to the pins RFO1 and RFO2. These drivers are differentially driving external antenna LC tank. It is also possible to operate only one of the two drivers by setting the IO Configuration Register 1 bit single. Each driver is composed of 8 segments having binary weighted output resistance. The MSB segment typical ON resistance is 2 Ω, when all segments are turned on; the output resistance is typically 1 Ω. Usually all segments are turned on to define the normal transmission (non-modulated) level. It is also possible to switch off certain segments when driving the non-modulated level to reduce the amplitude of signal on the antenna and/or to reduce the antenna Q factor without making any hardware changes. The RFO Normal Level Definition Register defines which segments ams Datasheet [v1-13] 2015-Jun-18 Page 17 Document Feedback AS3911B − Application Information are turned on to define the normal transmission (non-modulated) level. Default setting is that all segments are turned on. Using the single driver mode the number and therefore the cost of the antenna LC tank components is halved, but also the output power is reduced. In single mode it possible to connect two antenna LC tanks to the two RFO outputs and multiplex between them by controlling the IO Configuration Register 1 bit rfo2. In order to transmit the data the transmitter output level needs to be modulated. The AM and OOK modulation are supported. The type of modulation is defined by setting the bit tr_am in the Auxiliary Definition Register. For the operation modes supported by the AS3911B framing the setting of modulation type is done automatically by sending direct command Analog Preset. During the OOK modulation (for example ISO14443A) the Transmitter drivers stop driving the carrier frequency; drivers are frozen in state before the modulation. As consequence the amplitude of the antenna LC tank oscillation decays, the time constant of the decay is defined with the LC tank Q factor. The decay time in case of OOK modulation can be shortened by asserting the Auxiliary Definition Register bit ook_hr. When this bit is set to logic one the drivers are put in tristate during the OOK modulation. AM modulation (for example ISO14443B) is done by increasing the output driver impedance during the modulation time. This is done by reducing the number of driver segments which are turned on. The AM modulated level can be automatically adjusted to the target modulation depth by defining the target modulation depth in the AM Modulation Depth Control Register and sending the Calibrate Modulation Depth direct command. Please refer to AM Modulation Depth: Definition and Calibration for further details. Page 18 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Slow Transmitter Ramping When transmitter is enabled it starts to drive the antenna LC tank with full power, the ramping of field emitted by antenna is defined by antenna LC tank Q factor. However there are some reader systems where the reader field has to transition with a longer transition time when it is enabled. The STIF (Syndicat des transports d'Ile de France) specification requires a transition time from 10% to 90% of field longer than or equal to 10 μs. The AS3911B supports that feature. It is realized by collapsing VSP_RF regulated voltage when transmitter is disabled and ramping it when transmitter is enabled. Typical transition time is 15 μs at 3 V supply and 20 μs at 5 V supply. Procedure to implement the slow transition: • When transmitter is disabled set IO Configuration Register 2 bit slow_up to 1. Keep this state at least 2 ms to allow discharge of VSP_RF. • Enable transmitter, its output will ramp slowly. • Before sending any command set the bit slow_up back to 0. Receiver The receiver performs demodulation of the transponder sub-carrier modulation which is superimposed on the 13.56MHz carrier frequency. It performs AM and/or PM demodulation, amplification, band-pass filtering and digitalization of sub-carrier signals. Additionally it performs RSSI measurement, automatic gain control (AGC) and Squelch function. In typical application the Receiver inputs RFI1 and RFI2 are outputs of capacitor dividers connected directly to the terminals of antenna coil. Such concept assures that the two input signals are in phase to the voltage on antenna coil. Care has to be taken during design of capacitive divider that the RFI1 and RFI2 input signal pp value does not exceed the VSP_A supply voltage. Receiver comprises two complete receive channels for AM demodulation and PM demodulation. In case both channels are active the selection of channel used for reception framing is done automatically by receive framing logic. The receiver is switched on when Operation Control Register bit rx_en is set to one. Additionally the Operation Control Register contains bits rx_chn and rx_man; rx_chn defines whether both, AM and PM, demodulation channels will be active or only one of them, while bit rx_man defines the channel selection mode in case both channels are active (automatic or manual). Operation of the Receiver is controlled by four Receiver Configuration registers. The operation of the receiver is additionally controlled by the signal rx_on which is set high when modulated signal is expected on the receiver input. This signal is used to control ams Datasheet [v1-13] 2015-Jun-18 Page 19 Document Feedback AS3911B − Application Information RSSI and AGC and also enables processing of receiver output by Framing logic. Signal rx_on is automatically set high after Mask Receive timer expires. Signal rx_on can also be directly controlled by the controller by sending direct commands Mask Receive Data and Unmask Receive Data. Figure 15 illustrates the Receiver block diagram. Demodulation Stage First stage performs demodulation of transponder sub-carrier response signal, which is superimposed on HF field carrier. Two different blocks are implemented for AM demodulation: Peak Detector and AM demodulator mixer. The choice of the demodulator, which is used, is made by the Receiver Configuration Register 1 bit amd_sel. Peak detector performs AM demodulation using peak follower. Both, the positive and negative peaks are tracked to suppress common mode signal. It is limited in speed; it can operate for sub-carrier frequencies up to fc/8 (1700 kHz). It has demodulation gain G = 0.7. Its input is taken from one demodulator input only (usually RFI1). AM demodulator mixer uses synchronous rectification of both receiver inputs (RFI1 and RFI2). Its gain is G = 0.55. Mixer demodulator is optimized for VHBR sub-carrier frequencies. (fc/8 and higher). For sub-carrier frequency fc/8 (1700 kHz) both peak follower and mixer can be used, while for fc/4 and fc/2 are supported only by mixer. By default the Peak detector is used, for data rates fc/8 and higher use of mixer is automatically preset by sending direct command Analog Preset. PM demodulation is also done by a mixer. The PM demodulator mixer has differential outputs with 60mV differential signal for 1% phase change (16.67 mV per degree). Its operation is optimized for sub-carrier frequencies up to fc/8 (1700 kHz). In case the demodulation is done externally of the AS3911B it is possible to multiplex the LF signals applied to pins RFI1 and RFI2 directly to the gain and filtering stage by selecting the Receiver Configuration Register 2 bit lf_en. Page 20 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Figure 15: Receiver Block Diagram AM Demodulator Mixer rec1<7:6> rec2<6:5> rec4<7:4> RF_IN1 Peak Detector M U X rec3<7:5> AGC Squelch RSSI RSSI_AM<3:0> digital sub-carrier RX_on sg_on RF_IN2 rec3<4:2> rec4<3:0> AGC Squelch RSSI PM Demodulator Mixer RSSI_PM<3:0> digital sub-carrier rec3<2:0> Demodulation stage rec1<5:3> AC coupling + 1st gain stage Low-pass + 2nd gain stage High-pass + 3rd gain stage Digitizing stage Filtering and Gain Stages The receiver chain has band pass filtering characteristics. Filtering is optimized to pass sub-carrier frequencies while rejecting carrier frequency and low frequency noise and DC component. Filtering and gain is implemented in three stages where the first and the last stage have the first order high pass characteristics, while the mid stage has second order low pass characteristic. Gain and filtering characteristics can be optimized for current application by writing the Receiver Configuration Register 1 (filtering), Receiver Configuration Register 3 (gain in first stage) and Receiver Configuration Register 4 (gain in second and third stage). Gain of first stage is about 20dB and can be reduced in six 2.5 dB steps. There is also a special boost mode available, which boosts the maximum gain for additional 5.5 dB. In case of VHBR (fc/8 and fc/4) the gain is lower. The first stage gain can only be modified by writing Receiver Configuration Register 3. The default setting of this register is the minimum gain. Default first stage zero is located at 60 kHz, it can also be lowered to 40kHz or 12 kHz by writing option bits in the Receiver Configuration Register 1. The control of the first and third stage zeros is done with common control bits (see Figure 17). ams Datasheet [v1-13] 2015-Jun-18 Page 21 Document Feedback AS3911B − Application Information Gain in the second and third stage is 23 dB and can be reduced in six 3 dB steps. Gain of these two stages is included in AGC and Squelch loops or can be manually set in Receiver Configuration Register 4. Sending of direct command Reset Rx Gain is necessary to initialize the AGC, Squelch and RSSI block. Sending this command clears the current Squelch setting and loads the manual gain reduction from Receiver Configuration Register 4. Second stage has a second order low pass filtering characteristic, the pass band is adjusted according to sub-carrier frequency using the bits lp2 to lp0 of the Receiver Configuration Register 1. See Figure 16 for -1dB cut-off frequency for different settings. Figure 16: Low Pass Control rec1<5> lp2 rec1<4> lp1 rec1<3> lp0 -1 dB point 0 0 0 1200 kHz 0 0 1 600 kHz 0 1 0 300 kHz 1 0 0 2 MHz 1 0 1 7 MHz Other Not used Figure 17: First and Third Stage Zero Setting rec1<2> h200 rec1<1> h80 rec1<0> z12k First Stage Zero Third Stage Zero 0 0 0 60 kHz 400 kHz 1 0 0 60 kHz 200 kHz 0 1 0 40 kHz 80 kHz 0 0 1 12 kHz 200 kHz 0 1 1 12 kHz 80 kHz 1 0 1 12 kHz 200 kHz Other Page 22 Document Feedback Not used ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Figure 18 provides information on the recommended filter settings. For all supported operation modes and receive bit rates there is an automatic preset defined, additionally some alternatives are listed. Automatic preset is done by sending direct command Analog Preset. There is no automatic preset for Steam and Transparent modes. Since selection of filter characteristics also modifies gain, the gain range for different filter settings is also listed. Min1 Max23 Max1 Min23 Min All With Boost Gain [dB] Max All rec1<0> z12k rec1<1> h80 rec1<2> h200 rec1<5:3> lp<2:0> Figure 18: Receiver Filter Selection and Gain Range 000 0 0 0 43.4 28 26.4 11 49.8 Automatic preset for ISO14443A fc/128 and NFC Forum Type 1 Tag 000 1 0 0 44 29 27.5 12 49.7 Automatic preset for ISO14443B fc/128 ISO14443 fc/64 001 1 0 0 44.3 29 27 11.7 49.8 Recommended for 424/484 kHz sub-carrier 000 0 1 0 41.1 25.8 23.6 8.3 46.8 Alternative choice for ISO14443 fc/32 and fc/16 100 0 1 0 32 17 17.2 2 37.6 Automatic preset for ISO14443 fc/32 and fc/16 Alternative choice for fc/8 (1.7 kb/s) 100 0 0 0 32 17 17.2 2 37.6 Alternative choice for fc/8 (1.7 kb/s) 000 0 1 1 41.1 25.8 23.6 8.3 46.8 Automatic preset FeliCa (fc/64, fc/32) Alternative choice for ISO14443 fc/32 and fc/16 101 0 1 0 30 20 12 2 34 Alternative choice for fc/8 and fc/4 101 1 0 0 30 20 12 2 34 Automatic preset for fc/8 and fc/4 000 1 0 1 36.5 21.5 24.9 9.9 41.5 Comment Automatic preset for NFCIP-1 (initiator and target) Digitizing Stage Digitizing stage is producing a digital form of sub-carrier signal which is output of Receiver and input to Framing Logic. It is a window comparator with adjustable digitizing window (five possible settings, 3 dB steps, adjustment range from ±33 mV to ±120 mV). Adjustment of the digitizing window is included in AGC and Squelch loops or can be manually set in Receiver Configuration Register 4. ams Datasheet [v1-13] 2015-Jun-18 Page 23 Document Feedback AS3911B − Application Information AGC, Squelch and RSSI As mentioned above second and third gain stage gain and the Digitizing stage digitizing window are included in AGC and Squelch loops. Eleven settings are available, default state features minimum digitizer window and maximum gain, first four steps increase the digitizer window in 3 dB steps, next six steps additionally reduce the gain in 2 nd and 3rd gain stage also in 3 dB steps. The initial setting with which Squelch and AGC start is defined in Receiver Configuration Register 4. The Gain Reduction State Register displays the actual state of gain which results from Squelch, AGC and initial settings in Receiver Configuration Register 4. During bit anticollision like Type A, the AGC should be disabled. Squelch This feature is designed for operation of receiver in noisy environment. The noise can come from tags in which processing of data sent by the reader is going on and an answer is being prepared. Noise can also be generated by noisy environment. This noise may be misinterpreted as start of transponder response which results in decoding error. During execution of the Squelch procedure the output of Digitizing comparator is observed. In case there are more than two transitions on this output in 50 μs time period, gain is reduced for 3 dB and output is observed during next 50 μs. This procedure is repeated until number of transitions in 50 μs is lower or equal to 2 or until maximum gain reduction is reached. This setting is cleared by sending direct command Reset Rx Gain. There are two possibilities of performing squelch: automatic mode and using direct command Squelch. • Automatic mode is started in case bit sqm_dyn in the Receiver Configuration Register 2 is set. It is activated automatically 18.88 μs after end of Tx and is terminated with Mask Receive timer expire. This mode is primarily intended to suppress noise generated by tag processing during the time when the tag response is not expected (covered by Mask Receive timer). • Command Squelch is accepted in case it is sent when signal rx_on is low. It can be used in case the time window in which noise is present is known by the controller. AGC AGC (automatic gain control) is used to reduce gain to keep receiver chain out of saturation. In case gain is properly adjusted the demodulation process is also less influenced by system noise. AGC action starts when signal rx_on is asserted high and is reset when it is reset to low. At low to high transitions of the rx_on the state of the receiver gain is stored in the Gain Reduction State Register, therefore reading this register later gives the information of the gain setting used during last reception. Page 24 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information When AGC is switched on receiver gain is reduced so that the input to digitizer stage is not saturated. The AGC system comprises a window comparator which has its window 3.5 times larger than window of digitalization window comparator. When the AGC function is enabled gain is reduced until there are no transitions on its output. Such procedure assures that the input to digitalization window comparator is less than 3.5 times larger than its window. AGC operation is controlled by the control bits agc_en, agc_m and agc_fast in the Receiver Configuration Register 2. Bit agc_en enables the AGC operation; bit agc_m defines the AGC mode while bit agc_alg define the AGC algorithm. Two AGC modes are available, AGC can operate during complete Rx process (as long as signal rx_on is high) or it can be enabled only during first eight sub-carrier pulses. Two AGC algorithms are available; AGC can either start by presetting of code 4 h (max digitizer window, max gain) or by resetting the code to 0 h (min digitizer window, max gain). Algorithm with preset code is faster, therefore it is recommended for protocols with short SOF (like ISO14443A fc/128). Default AGC settings are: AGC is enabled, AGC operates during complete Rx process, algorithm with preset is used. RSSI The receiver also performs the RSSI (Received Signal Strength Indicator) measurement of both channels. RSSI measurement is started after rising edge of rx_on. It stays active while signal rx_on is high; while rx_on is low it is frozen. It is a peak hold system; the value can only increase from initial zero value. Every time the AGC reduces the gain the RSSI measurement is reset and starts from zero. Result of RSSI measurements is 4-bit value which can be observed by reading the RSSI Display Register. The LSB step is 2.8 dB, the maximum code is D h (13d). Since the RSSI measurement is of peak hold type the RSSI measurement result does not follow any variations in the signal strength (the highest value will be kept). In order to follow RSSI variation it is possible to reset RSSI bits and restart the measurement by sending direct command Clear RSSI. Receiver in NFCIP-1 Active Communication Mode There are several features built in receiver to enable reliable reception of active NFCIP-1 communication. All these settings are automatically preset by sending direct command Analog Preset after the NFCIP-1 mode has been configured. In addition to filtering options there are two NFC specific configuration bits stored in the Receiver Configuration Register 3. Bit lim enables clipping circuits which are positioned after first and second gain stages. The intention of clipping circuits is to limit the signal level for the following filtering stage (in case the NFC peer is close the input signal level can be quite high). ams Datasheet [v1-13] 2015-Jun-18 Page 25 Document Feedback AS3911B − Application Information Bit rg_nfc forces gain reduction of second and third filtering stage to -6dB while keeping the digitizer comparator window at maximum level. Capacitive Sensor The Capacitive Sensor block provides a possibility of low power detection of tag presence. The capacitive measurement system comprises two electrodes. One is excitation electrode emitting electrical field of a fixed frequency in range of few hundred kHz (CSO) and the second one is the sensing electrode (CSI). The amount of charge generated in sensing electrode represents the capacitance between the two electrodes. Capacitive sensor electrodes are tolerant to parasitic capacitance to ground (up to 25 pF) and to input leakage (up to 1 MΩ). Since the charge on the sensing electrode is generated with the frequency of excitation electrode, synchronous rectifier is used to detect it. This ensures good rejection of interference and high tolerance to parasitic capacitances (to all nodes except the excitation electrode). Capacitive sensor system depicted on figure below uses a synchronous rectifier to convert the AC charge generated by the excitation signal on the sensing electrode. This yields a DC output voltage, which is linearly proportional to the capacitance between the excitation and sensing electrode. The output DC voltage is converted by an AD converter in absolute mode. Result is stored in the A/D Converter Output Register (see also A/D Converter). Figure 19: Capacitive Sensor Block Diagram CSO Oscillator A/D Converter Page 26 Document Feedback Synchronous Rectifier CSI ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Any conductive object (human hand or tag's antenna windings) approaching the two electrodes changes the capacitance between the excitation and sensing electrode as it 'shortens' the distance between the two by providing conductance on the part of the path between the two electrodes. Capacitance measurement is started by sending direct command Measure Capacitance. The AS3911B can also be configured to periodically wake-up and perform the capacitance measurement. The result is compared to a stored reference or to an average of previous measurements and in case the difference is greater than a predefined value an IRQ is triggered to wake-up the controller (see also Wake-Up Mode). Capacitor sensor gain can be adjusted by setting in Capacitive Sensor Control Register. Default gain is 2.8 V/pF typ., maximum gain is 6.5 V/pF typ. Since LSB of AD converter corresponds to approximately 7.8mV, the default gain results in sensitivity of 2.8 fF/LSB (1.2 fF/LSB maximum). Capacitance measurement duration is 200 μs, current consumption during measurement is 1.1 mA typ. In case capacitive measurement is performed every 100 ms in Wake-up mode the resulting typical average consumption is 5.8 μA (3.6 μA is standby consumption in Wake-up mode). Capacitor Sensor Calibration Capacitor sensor comprises calibration unit internally compensates the parasitic capacitances between CSI and CSO, thus leaving full measurement range for information about capacitance variation. 5 bits are used to control the calibration, minimum calibration step is 0.1pF, calibration range is 3.1 pF. Calibration can be done manually by writing Capacitive Sensor Control Register or automatically by sending direct command Calibrate Capacitive Sensor. The status of Calibrate Capacitive Sensor command and resulting calibration value are stored in the Capacitive Sensor Display Register. In order to avoid interference of Capacitive Sensor with Xtal oscillator and reader magnetic field and to assure repetitive results it is strongly recommended to perform capacitance measurement and calibration in Power-down mode only. ams Datasheet [v1-13] 2015-Jun-18 Page 27 Document Feedback AS3911B − Application Information Wake-Up Mode Asserting the Operation Control Register bit wu while the other bits are set to 0 puts the AS3911B into the Wake-up mode which is used to perform low power detection of card presence. The AS3911B includes several possibilities of low power detection of a card presence (capacitive sensor, phase measurement, amplitude measurement). Low power 32 kHz RC oscillator and register configurable Wake-up timer are used to schedule periodic detection. Usually the presence of a card is detected by so called polling. In this process the reader is periodically turned on and the controller activates the protocol to check whether a card is present. Such procedure consumes a lot of energy since reader field has to be turned on for 5 ms before a command can be issued. Low power detection of card presence is performed by detecting a change in reader environment, which is produced by presence of a card. When a change is detected, an interrupt is sent to the controller. As a result, the controller can activate the protocol for tag detection. In the Wake-up mode the AS3911B periodically performs the configured measurements and sends an IRQ to the controller, which is in deep sleep to minimize the current consumption, only when a difference to the build in reference is detected. Detection of card presence can be done by performing phase, amplitude and capacitive sensor measurements. Presence of a card close to the reader antenna coil produces due to the magnetic coupling of the two coils a change of the antenna LC tank signal phase and amplitude. The reader field activation time needed to perform the phase or the amplitude measurement is extremely short (~20 μs) comparing to the activation time needed to send a protocol activation command. Additionally the power level during the measurement can be lower than the power level during normal operation since the card does not have to be powered to produce the coupling effect. The emitted power can be reduced by increasing the RFO Normal Level Definition Register. Capacitance Sensor detects a change of the parasite capacitance between the two excitation electrodes which is caused by a card antenna and a hand holding it. See Capacitive Sensor for a detailed information on the capacitive sensor. The registries on locations from 31h to 3D h are dedicated to Wake-up configuration and display. The Wake-Up Timer Control Register is the main Wake-up mode configuration register. The timeout period between the successive detections and the measurements which are going to be used are selected in this register. Timeouts in the range from 10 ms to 800 ms are Page 28 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information available, 100 ms is the default value. Any combination of available measurements can be selected (one, two or all of them). The following twelve registers (32h to 3D h) are configuring the three possible detection measurements and storing the results, four registers are used for each measurement. An IRQ is sent when the difference between a measured value and reference value is larger than configured threshold value. There are two possibilities how to define the reference value: • The AS3911B can calculate the reference based on previous measurements (auto-averaging) • The controller determines the reference and stores it in a register The first register in the series of four is the Measurement Configuration Register (see for e.g. Amplitude Measurement Configuration Register). The difference to reference which triggers the IRQ, the method of reference value definition and the weight of last measurement result in case of auto-averaging are defined in this register. The next register is storing the reference value in case the reference is defined by the controller. The following two registers are display registers. The first one stores the auto-averaging reference; the second one stores the result of the last measurement. Wake-up mode configuration registers have to be configured before wake-up mode is actually entered. Any modification of Wake-up mode configuration while it is active may result in unpredictable behavior. Auto-Averaging In case of auto-averaging the reference value is recalculated after every measurement. The last measurement value, the old reference value and the weight are used in this calculation. The following formula is used to calculate the new reference value. (EQ1) OldAverage – MeasuredValue NewAverage = OldAverage + -------------------------------------------------------------------------------Weight The calculation is done on 10 bits to have sufficient precision. The auto-averaging process is initialized when Wake-up mode is first time entered after initialization (power-up or using Set Default command). The initial value is taken from the Measurement Display Register (for example Amplitude Measurement Display Register) until the content of this register is not zero. Every Measurement Configuration register contains a bit which defines whether the measurement which causes an interrupt is taken in account for the average value calculation (for example bit am_aam of the Amplitude Measurement Configuration Register). ams Datasheet [v1-13] 2015-Jun-18 Page 29 Document Feedback AS3911B − Application Information Quartz Crystal Oscillator The quartz crystal oscillator can operate with 13.56 MHz and 27.12 MHz crystals. The operation of quartz crystal oscillator is enabled when the Operation Control Register bit en is set to one. An interrupt is sent to inform the microcontroller when the oscillator frequency is stable (see Main Interrupt Register). The status of oscillator can be observed by observing the Auxiliary Display Register bit osc_ok. This bit is set to ‘1’ when oscillator frequency is stable. The oscillator is based on an inverter stage supplied by controlled current source. A feedback loop is controlling the bias current in order to regulate amplitude on XTI pin to 1 Vpp. In order to enable a fast reader start-up an interrupt is sent when oscillator amplitude exceeds 750 mVpp. Division by two assures that 13.56 MHz signal has a duty cycle of 50% which is better for the Transmitter performance (no PW distortion). Use of 27.12 MHz crystal is therefore recommended for better performance. In case of 13.56 MHz crystal, the bias current of stage which is digitizing oscillator signal is increased to assure as low PW distortion as possible. Please note that in case of VHBR reception (bit rates fc/8 and above) it is mandatory to use the 27.12 MHz crystal since high frequency clock is needed for receive framing. The oscillator output is also used to drive a clock signal output pin MCU_CLK), which can be used by the external microcontroller. The MCU_CLK pin is configured in the IO Configuration Register 2. Timers The AS3911B contains several timers which eliminate the need to run counters in the controller, thus reducing the effort of the controller code implementation and improve portability of code to different controllers. Every timer has one or more associated configuration registers in which the timeout duration and different operating modes are defined. These configuration registers have to be set while the corresponding timer is not running. Any modification of timer configuration while the timer is active may result in unpredictable behavior. All timers except the Wake-up timer are stopped by direct command Clear. Exception: In case bit nrt_emv in the General Purpose and No-Response Timer Control Register is set to one, the No-Response Timer is not stopped. Page 30 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Mask Receive Timer and No-Response Timer Mask Receive Timer and No-Response Timer are both automatically started at the end of transmission (at the end of EOF). Mask Receive Timer The Mask Receive Timer is blocking the receiver and reception process in framing logic by keeping the rx_on signal low after the end of Tx during the time the tag reply is not expected. While the Mask Receive Timer is running, the Squelch is automatically turned on (if enabled). Mask Receive Timer does not produce an IRQ. The Mask Receive Timer timeout is configured in the Mask Receive Timer Register. In the NFCIP-1 active communication mode the Mask Receive Timer is started when the peer NFC device (a device with which communication is going on) switches on its field. The Mask Receive Timer has a special use in the low power Initial NFC Target Mode. After the initiator field has been detected the controller turns on the oscillator, regulator and receiver. Mask Receive Timer is started by sending direct command Start Mask-Receive Timer. After the Mask Receive Timer expires the receiver output starts to be observed to detect start of the initiator message. In this mode the Mask Receive Timer clock is additionally divided by eight it (one count is 512/fc) to cover range up to ~9.6 ms. No-Response Timer As its name indicates this timer is intended to observe whether a tag response was detected in a configured time started by end of transmission. The I_nre flag in the Timer and NFC Interrupt Register is signaling interrupt events resulting from this timer timeout. The No-Response Timer is configured by writing two No-Response Timer setting registers: No-Response Timer Register 1and No-Response Timer Register 2. Operation options of the No-Response Timer are defined by setting bits nrt_emv and nrt_step in the General Purpose and No-Response Timer Control Register. Bit nrt_step configures the time step of the No-Response Timer. Two steps are available, 64/fc (4.72 μs), which covers range up to 309 ms and 4096/fc, which covers range up to 19.8 s. Bit nrt_emv controls the timer operation mode: • When this bit is set to 0 (default mode) the IRQ is produced in case the No-Response Timer expires before a start of a tag reply is detected and rx_on is forced to low to stop receiver process. In the opposite case, when start of a tag reply is detected before timeout, the timer is stopped, and no IRQ is produced. • When this bit is set to 1 the timer unconditionally produces an IRQ when it expires, it is also not stopped by direct command Clear. This means that IRQ is independent of the fact whether or not a tag reply was detected. In case at the moment of timeout a tag reply is being processed ams Datasheet [v1-13] 2015-Jun-18 Page 31 Document Feedback AS3911B − Application Information no other action is taken, in the opposite case, when no tag response is being processed additionally the signal rx_on is forced to low to stop receive process. The No-Response Timer can also be started using direct command Start No-Response Timer. The intention of this command is to extend the No-Response Timer timeout beyond the range defined in the No-Response Timer control registers. In case this command is sent while the timer is running, it is reset and restarted. In NFCIP-1 active communication mode the No-Response Timer cannot be started using the direct command. In case this timer expires before the peer NFC device (a device with which communication is going on) switches on its field an interrupt is sent. In all modes, where timer is set to nonzero value, it is a must that M_txe is not set and interrupt I_txe is read via SPI for synchronization between transmitter and timer. General Purpose Timer The triggering of the General Purpose Timer is configured by setting the General Purpose and No-Response Timer Control Register. It can be used to survey the duration of reception process (triggering by start of reception, after SOF) or to time out the PCD to PICC response time (triggered by end of reception, after EOF). In the NFCIP-1 active communication mode it is used to timeout the field switching off. In all cases an IRQ is sent when it expires. The General Purpose Timer can also be started by sending the direct command Start General Purpose Timer. In case this command is sent while the timer is running, it is reset and restarted. Wake-Up Timer Wake timer is primarily used in the Wake-up mode (see Wake-Up Mode). Additionally it can be used by sending a direct command Start Wake-Up Timer. This command is accepted in any operation mode except Wake-up mode. When this command is send the RC oscillator, which is used as clock source for wake-up timer is started, timeout is defined by setting in the Wake-Up Timer Control Register. When the timer expires, an IRQ with the I_wt flag in the Error and Wake-Up Interrupt Register is sent. Wake-Up Timer is useful in the Low Power operation mode, in which other timers cannot be used (in the Low Power operation mode the crystal oscillator, which is clock source for the other timers, is not running). Please note that the tolerance of Wake-Up Timer timeout is defined by tolerance of the RC oscillator. Page 32 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information A/D Converter The AS3911B contains an 8-bit successive approximation A/D converter. Input to A/D converter can be multiplexed from different sources to be used in several direct commands and adjustment procedures. The result of last A/D conversion is stored in the A/D Converter Output Register. Typical conversion time is 224/fc (16.5 μs). The A/D converter has two operating modes, absolute and relative. • In absolute mode the low reference is 0V and the high reference is 2 V. This means that A/D converter input range is from 0 to 2 V, 00h code means input is 0 V or lower, FF h means that input is 2 V - 1LSB or higher, LSB is 7.8125 mV. • In relative mode low reference is 1/6 of VSP_A and high reference is 5/6 of VSP_A, so the input range is from 1/6 VSP_A to 5/6 VSP_A. Relative mode is only used in phase measurement (phase detector output is proportional to power supply). In all other cases absolute mode is used. Phase and Amplitude Detector This block is used to provide input to A/D Converter to perform measurements of amplitude and phase, expected by direct commands Measure Amplitude and Measure Phase. Several phase and amplitude measurements are also performed by direct commands Calibrate Modulation Depth and Calibrate Antenna. Phase Detector The phase detector is observing phase difference between the transmitter output signals (RFO1 and RFO2) and the receiver input signals RFI1 and RFI2, which are proportional to the signal on the antenna LC tank. These signals are first passed by digitizing comparators. Digitized signals are processed by a phase detector with a strong low pass filter characteristics to get average phase difference. The Phase Detector output is inversely proportional to the phase difference between the two inputs. The 90° phase shift results in VSP_A/2 output voltage, in case both inputs are in phase output voltage is VSP_A in case they are in opposite phase output voltage is zero. During execution of direct command Measure Phase this output is multiplexed to A/D Converter input (A/D Converter is in relative mode during execution of command Measure Phase). Since the A/D converter range is from 1/6 VSP_A to 5/6 VSP_A the actual phase detector range is from 30º to 150º. Figures below depict the two inputs and output of phase detector in case of 90º and 135º phase shift. ams Datasheet [v1-13] 2015-Jun-18 Page 33 Document Feedback AS3911B − Application Information Figure 20: Phase Detector Inputs and Output in case of 90º Phase Shift VSP VSP VSP VSP/2 0 Figure 21: Phase Detector Inputs and Output in case of 135º Phase Shift VSP VSP VSP VSP/2 0 Amplitude Detector Signals from pins RFI1 and RFI2 are used as inputs to the self-mixing stage. Output of this stage is DC voltage proportional to amplitude of signal on pins RFI1 and RFI2. During execution of direct command Measure Amplitude this output is multiplexed to A/D Converter input. Page 34 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information External field Detector The External Field Detector is used to detect the presence of an external device generating an RF field. It is automatically switched on in NFCIP-1 active communication modes; it can also be used in other modes. The External Field Detector supports two different detection thresholds, Peer Detection Threshold and Collision Avoidance Threshold. The two thresholds can be independently set by writing the External Field Detector Threshold Register. The actual state of the External Field Detector output can be checked by reading the Auxiliary Display Register. Input to this block is the signal from the RFI1 pin. Peer Detection Threshold This threshold is used to detect the field emitted by peer NFC device with which NFC communication is going on (initiator field in case the AS3911B is a target and the opposite, target field in case the AS3911B is an initiator). It can be selected in the range from 75 mVpp to 800 mVpp. When this threshold is enabled the External Field Detector is in low power mode. An interrupt is generated when an external field is detected and also when it is switched off. With such implementation it can also be used to detect the moment when the external field disappears. This is useful to detect the moment when the peer NFC device (it can be either an initiator or a target) has stopped emitting an RF field. The External Field Detector is automatically enabled in the low power Peer Detection mode when NFCIP-1 mode (initiator or target) is selected in the Bit Rate Definition Register. Additionally it can be enabled by setting bit en_fd in the Auxiliary Definition Register. Collision Avoidance Threshold This threshold is used during the RF Collision Avoidance sequence which is executed by sending NFC Field ON commands (see NFC Field ON Commands). It can be selected in the range from 25 mVpp to 800 mVpp. ams Datasheet [v1-13] 2015-Jun-18 Page 35 Document Feedback AS3911B − Application Information Power Supply System The AS3911B features two positive supply pins, V DD and VDD_IO. V DD is the main power supply pin. It supplies the AS3911B blocks through three regulators (V DD_A, V DD_D and VDD_RF). V DD range from 2.4 to 5.5 V is supported. V DD_IO is used to define supply level for digital communication pins (/SS, MISO, MOSI, SCLK, IRQ, MCU_CLK). Digital communication pins interface to the AS3911B logic through level shifters, therefore the internal supply voltage can be either higher or lower than V DD_IO. V DD_IO range from 1.65 V to 5.5 V is supported. Figure 23 shows the building blocks of the AS3911B power supply system. It contains three regulators, a power-down support block, a block generating analog reference voltage (AGD) and a block performing automatic power supply adjustment procedure. The three regulators are providing supply to analog blocks (VSP_A), logic (VSP_D) and transmitter (VSP_RF). The use of VSP_A and VSP_D regulators is mandatory at 5V power supply to provide regulated voltage to analog and logic blocks which only use 3.3 V devices. The use of VSP_A and VSP_D regulators at 3 V supply and VSP_RF regulator at any supply voltage is recommended to improve system PSRR. Regulated voltage can be adjusted automatically to have maximum possible regulated voltage while still having good PSRR. All regulator pins also have corresponding negative supply pins which are externally connected to ground potential (VSS). The reason for separation is in decoupling of noise induced by voltage drops on the internal power supply lines. Figure 13 and Figure 14 depict typical AS3911B application schematics with all regulators used. All regulator pins and AGD voltage are buffered with capacitor. Recommended blocking capacitor values can be found in the table below are 2.2 μF in parallel with 10 nF, for pin AGD 1 μF in parallel with 10 nF is suggested. Figure 22: Recommended Blocking Capacitor Values Pins Recommended Capacitors AGD-VSS 1μF || 10nF VSP_A-VSN_A VSP_D-VSN_D 2.2μF || 10nF 2.2μF || 10nF VSP_RF-VSN_RF 2.2μF || 10nF Page 36 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Figure 23: The AS3911B Power Supply System VDD VSP_D REG Power-down Support 1k ohm EN sup3V VSP_A REG 50 ohm BGR & AGC VSP_RF REG VSP_RF VSP_A VSP_D AGD RV<3:0> reg2Ah adjust AUTOREG reg2Bh Regulators have two basic operation modes depending on supply voltage, 3.3 V supply mode (max 3.6 V) and 5 V supply mode (max 5.5V). The supply mode is set by writing bit sup3 V in the IO Configuration Register 2. Default setting is 5 V so this bit has to be set to one after power-up in case of 3.3 V supply. In 3.3 V mode all regulators are set to the same regulated voltage in range from 2.4 V to 3.4 V, while in 5 V only the VSP_RF can be set in range from 3.9 V to 5.1 V, while VSP_A and VSP_D are fixed to 3.4 V. Figure 23 depicts signals controlling the power supply system. The regulators are operating when signal en is high (en is configuration bit in Operation Control Register. When signal en is low the AS3911B is in low power Power-down mode. In this mode consumption of the power supply system is also minimized. ams Datasheet [v1-13] 2015-Jun-18 Page 37 Document Feedback AS3911B − Application Information VSP_RF Regulator The intention of this regulator is to improve PSRR of the Transmitter (the noise of the Transmitter power supply is emitted and fed back to the Receiver). The VSP_RF regulator operation is controlled and observed by writing and reading two regulator registers: • Regulator Voltage Control Register controls the regulator mode and regulated voltage. Bit reg_s controls regulator mode. In case it is set to 0 (default state) the regulated voltage is set using direct command Adjust Regulators. When bit reg_s is asserted to 1 regulated voltage is defined by bits rege_3 to rege_1 of the same register. The regulated voltage adjustment range depends on the power supply mode. In case of 5 V supply mode the adjustment range is between 3.9 V and 5.1 V in steps of 120 mV, in case of 3.3 V supply mode the adjustment range is from 2.4 V to 3.4 V with steps of 100 mV. Default regulated voltage is the maximum one (5.1 V and 3.4 V in case of 5 V and 3.3 V supply mode respectively). • Regulator and Timer Display Register is a read only register which displays actual regulated voltage when regulator is operating. It is especially useful in case of automatic mode, since the actual regulated voltage, which is result of direct command Adjust Regulators, can be observed. The VSP_RF regulator also includes a current limiter which limits the regulator typically to current of 200 mA rms in normal operation (500 mA in case of short). In case the Transmitter output current higher the 200 mArms is required, VSP_RF regulator cannot be used to supply the Transmitter, VSP_RF has to be externally connected to V DD (connection of VSP_RF to supply voltage higher than VDD is not allowed). The voltage drop of the Transmitter current is the main source of the AS3911B power dissipation. This voltage drop is composed of drop in the Transmitter driver and in the drop on VSP_RF regulator. Due to this it is recommended to set regulated voltage using direct command Adjust Regulators. It results in good power supply rejection ration with relatively low dissipated power due to regulator voltage drop. In Power-down mode the VSP_RF regulator is not operating. VSP_RF pin is connected to V DD through 1 kΩ resistor. Connection through resistors assures smooth power-up of the system and a smooth transition from Power-down mode to other operating modes. Page 38 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information VSP_A and VSP_D Regulators VSP_A and VSP_D regulators are used to supply the AS3911B analog and digital blocks respectively. In 3.3 V mode, VSP_A and VSP_D regulator are set to the same regulated voltage as the VSP_RF regulator, in 5 V mode VSP_A and VSP_D regulated voltage is fixed to 3.4 V. The use of VSP_A and VSP_D regulators is obligatory in 5 V mode since analog and digital blocks supplied with these two pins contain low voltage transistors which support maximum supply voltage of 3.6 V. In 3.3 supply mode the use of regulators is strongly recommended in order to improve PSRR of analog processing. For low cost applications it is possible to disable the VSP_D regulator and to supply digital blocks through external short between VSP_A and VSP_D (configuration bit vspd_off in the IO Configuration Register 2. In case VSD_D regulator is disabled VSP_D can alternatively be supplied from V DD (in 3.3 V mode only) in case VSP_A is not more than 300 mV lower than V DD. Power-Down Support Block In the Power-down mode the regulators are disabled in order to save current. In this mode a low power Power-down support block which maintains the VSP_D and VSP_A in below 3.6 V is enabled. Typical regulated voltage in this mode is 3.1 V at 5 V supply and 2.2 V at 3 V supply. When 3.3 V supply mode is set the Power-down support block is disabled, its output is connected to V DD through 1 kΩ resistor. Typical consumption of Power-down support block is 600 nA at 5 V supply. Measurement of Supply Voltages Using direct command Measure Power Supply it is possible to measure V DD and regulated voltages VSP_A, VSP_D, and VSP_RF. ams Datasheet [v1-13] 2015-Jun-18 Page 39 Document Feedback AS3911B − Application Information Communication to External Microcontroller The AS3911B is a slave device and the external microcontroller initiates all communication. Communication is performed by a 4-wire Serial Peripheral Interface (SPI). The AS3911B asks microcontroller for its attention by sending an interrupt (pin IRQ). In addition, the microcontroller can use clock signal available on pin MCU_CLK when the oscillator is running. Serial Peripheral Interface (SPI) While signal /SS is high the SPI interface is in reset, while it is low the SPI interface is enabled. It is recommended to keep signal /SS high whenever the SPI interface is not in use. MOSI is sampled at the falling edge of SCLK. All communication is done in blocks of 8 bits (bytes). First two bits of first byte transmitted after high to low transition of /SS define SPI operation mode. MSB bit is always transmitted first (valid for address and data). Read and Write modes support address auto-incrementing, which means that in case after the address and first data byte some additional data bytes are sent (read), they are written to (read from) addresses incremented by ‘1’. Figure 26 defines possible modes. MISO output is usually in tristate, it is only driven when output data is available. Due to this the MOSI and the MISO can be externally shorted to create a bidirectional signal. During the time the MISO output is in tristate, it is possible to switch on a 10 kΩ pull down by activating option bits miso_pd1 and miso_pd2 in the IO Configuration Register 2. Figure 24: Serial Data Interface (4-wire interface) Signal Lines Name Signal Signal Level Description /SS Digital input CMOS SPI Enable (active low) MOSI Digital input CMOS Serial data input MISO Digital output with tristate CMOS Serial data output SCLK Digital input CMOS Clock for serial communication Page 40 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Figure 25: Signal to Microcontroller Separate SPI Input and Output Signals to Microcontroller MOSI Bidirectional Data IO Signal to Microcontroller MOSI MOSI AS3911 AS3911 MISO I/O MISO MISO Figure 26 provides information on the SPI operation modes. Reading and writing of registers is possible in any AS3911B operation mode. FIFO operations are possible in case en (bit 7 of the Operation Control Register) is set and Xtal oscillator frequency is stable. Figure 26: SPI Operation Modes MODE Pattern (communication bits) MODE MODE Trailer MODE Related Data M1 M0 C5 C4 C3 C2 C1 C0 Register Write 0 0 A5 A4 A3 A2 A1 A0 Data byte (or more bytes in case of auto-incrementing) Register Read 0 1 A5 A4 A3 A2 A1 A0 Data byte (or more bytes in case of auto-incrementing) FIFO Load 1 0 0 0 0 0 0 0 One or more bytes of FIFO data FIFO Read 1 0 1 1 1 1 1 1 One or more bytes of FIFO data Direct Command Mode 1 1 C5 C4 C3 C2 C1 C0 ams Datasheet [v1-13] 2015-Jun-18 Page 41 Document Feedback AS3911B − Application Information Writing of Data to Addressable Registers (Write Mode) Following figures show cases of writing a single byte and writing multiple bytes with auto-incrementing address. After the SPI operation mode bits, the address of register to be written is provided. Then one or more data bytes are transferred from the SPI, always from the MSB to the LSB. The data byte is written in register on falling edge of its last clock. In case the communication is terminated by putting /SS high before a packet of 8 bits composing one byte is sent, writing of this register is not performed. In case the register on the defined address does not exist or it is a read only register no write is performed. Figure 27: SPI Communication: Writing of Single Byte /SS SCLK MOSI X 0 0 Two leading bits indicate Mode A 5 A 4 A 3 SCLK rising edge Data is transfered from µC A 2 A 1 A 0 D 7 D 6 D 5 D 4 D 3 D 2 D 1 D 0 Data is moved to Address A5-A0 SCLK falling edge Data is sampled X /SS rising edge signals end of WRITE Mode Figure 28: SPI Communication: Writing of Multiple Bytes /SS SCLK MOSI X 0 0 A A A A A A D D D D D D D D D D D D D D D D D D 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0 7 6 Two leading bits indicate Mode Page 42 Document Feedback Data is moved to Address <A5-A0> Data is moved to Address <A5-A0> + 1 D D D D D D D D D D 1 0 7 6 5 4 3 2 1 0 Data is moved to Address <A5-A0> + (n-1) Data is moved to Address <A5-A0> + n X /SS rising edge signals end of WRITE Mode ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Reading of Data from Addressable Registers (Read Mode) After the SPI operation mode bits the address of register to be read has to be provided from the MSB to the LSB. Then one or more data bytes are transferred to MISO output, always from the MSB to the LSB. As in case of the write mode also the read mode supports auto-incrementing address. MOSI is sampled at the falling edge of SCLK (like shown in the following diagrams), data to be read from the AS3911B internal register is driven to MISO pin on rising edge of SCLK and is sampled by the master at the falling edge of SCLK. In case the register on defined address does not exist all 0 data is sent to MISO. Figure 29 provides an example for reading of single byte. Figure 29: SPI Communication: Reading of Single Byte /S S SCLK MOSI X 0 1 M IS O A 5 A 4 A 3 A 2 A 1 A 0 D 7 trista te T w o le a d in g b its in d ica te M ode S C L K ris in g e d g e D a ta is tra n sfe re d fro m µ C X S C L K fa llin g e d g e D a ta is sa m p le d D 6 S C L K ris in g e d g e D a ta is m o ve d fro m A d d re ss < A 5 -A 0 > D 5 D 4 D 3 D 2 D 1 D 0 S C L K fa llin g e d g e D a ta is tra n sfe re d to µ C tris ta te /S S risin g e d g e sig n a ls e n d o f R E A D M ode Loading Transmitting Data into FIFO Loading the transmitting data into the FIFO is similar to writing data into an addressable registers. Difference is that in case of loading more bytes all bytes go to the FIFO. SPI operation mode bits 10 indicate FIFO operations. In case of loading transmitting data into FIFO all bits <C5 – C0> are set to 0. Then a bit-stream, the data to be sent (1 to 96 bytes), can be transferred. In case the command is terminated by putting /SS high before a packet of 8 bits composing one byte is sent, writing of that particular byte in FIFO is not performed. Figure 30 shows how to load the Transmitting Data into the FIFO. ams Datasheet [v1-13] 2015-Jun-18 Page 43 Document Feedback AS3911B − Application Information Figure 30: SPI Communication: Loading of FIFO /SS SCLK MOSI 1 X 0 0 10 pattern indicates FIFO mode 0 0 0 0 SCLK falling edge Data is sampled SCLK rising edge Data is transfered from µC 1 to 96 bytes 0 X Start of payload Data Reading Received Data from FIFO Reading received data from the FIFO is similar to reading data from an addressable registers. Difference is that in case of reading more bytes they all come from the FIFO. SPI operation mode bits 10 indicate FIFO operations. In case of reading the received data from the FIFO all bits <C5 – C0> are set to 1. On the following SCLK rising edges the data from FIFO appears as in case of read data from addressable registers. In case the command is terminated by putting /SS high before a packet of 8 bits composing one byte is read that particular byte is considered unread and will be the first one read in next FIFO read operation. Figure 31: SPI Communication: Reading of FIFO /S S SCLK MOSI 1 X 0 M IS O 1 1 1 1 1 X 1 1 to 9 6 b y te s trista te 1 0 p attern in dica tes F IF O m o d e Page 44 Document Feedback S C L K rising e d g e D ata is tran sfe re d from µ C S C L K fa llin g ed g e D a ta is sa m p led S C LK risin g e dg e D a ta is m o ve d from F IF O trista te S C L K falling e d ge D ata is tra n sfe red to µC ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Direct Command Mode Direct Command Mode has no arguments, so a single byte is sent. SPI operation mode bits 11 indicate Direct Command Mode. The following six bits define command code, sent MSB to the LSB. The command is executed on falling edge of last clock. While execution of some Direct Commands is immediate, there are others which start a process of certain duration (calibration, measurement…). During execution of such commands it is not allowed to start another activity over the SPI interface. After execution of such a command is terminated an IRQ is sent. Figure 32: SPI Communication: Direct Command /SS SCLK MOSI X 1 1 Two leading ONE indicate COMMAND Mode C5 C4 C3 SCLK rising edge Data is transfered from µC C2 C1 C0 SCLK falling edge Data is sampled X /SS rising edge signals start of command execution Direct Command Chaining Direct commands with immediate execution can be followed by another SPI mode (Read, Write or FIFO) without deactivating /SS signal in between. Figure 33: Direct Command Chaining /SS Direct Command ams Datasheet [v1-13] 2015-Jun-18 Read, Write or FIFO Mode Page 45 Document Feedback AS3911B − Application Information SPI Timing Figure 34: SPI Timing Symbol Parameter Min Typ Max Unit Notes General Timing (VDD = VDD_IO = VDD_D = 3.3 V, Temperature 25°C) TSCLK=TSCLKL+TSCLKH, use of shorter SCLK period may lead to incorrect operation of FIFO TSCLK SCLK period 100 TSCLKL SCLK low 40 TSCLKH SCLK high 40 ns TSSH SPI reset (/SS high) 100 ns TNCSL /SS falling to SCLK rising 25 ns First SCLK pulse TNCSH SCLK falling to /SS rising 25 (tbd) ns Last SCLK pulse TDIS Data in setup time 10 ns TDIH Data in hold time 10 ns ns *1 ns Read Timing (VDD = VDD_IO = VDD_D = 3.3 V, Temperature 25°C, CLOAD ≤50 pF) TDOD Data out delay 20 ns TDOHZ Data out to high impedance delay 20 ns Figure 35: SPI General Timing /SS ... tNCSL tSCLKH tSCLKL t NCSH ... SCLK t DIS MOSI MISO Page 46 Document Feedback tDIH DATAI DATAI ... DATAI ... ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Figure 36: SPI Read Timing ... /S S ... SCLK MOSI ... DATAI M IS O DATAO tD O D ... DATAO tD O H Z Interrupt Interface There are three interrupt registers implemented in the AS3911B (Main Interrupt Register and auxiliary Timer and NFC Interrupt Register and Error and Wake-Up Interrupt Register). Main Interrupt Register contains information about six interrupt sources, while two bits reference to interrupt sources detailed in Timer and NFC Interrupt Register and Error and Wake-Up Interrupt Register. When an interrupt condition is met the source of interrupt bit is set in the Main Interrupt Register and the IRQ pin transitions to high. The microcontroller then reads the Main Interrupt Register to distinguish between different interrupt sources. The interrupt registers 0x17, 0x18 and 0x19 are to be read in one attempt. After a particular Interrupt Register is read, its content is reset to 0. Exceptions to this rule are the bits pointing to auxiliary registers. These bits are only cleared when corresponding auxiliary register is read. IRQ pin transitions to low after the interrupt bit(s) which caused its transition to high has been read. Please note that there may be more than one interrupt bits set in case the microcontroller did not immediately read the interrupt registers after the IRQ signal was set and another event causing interrupt occurred. In that case the IRQ pin transitions to low after the last bit which caused interrupt is read. In case an interrupt from a certain source is not required it can be disabled by setting corresponding bit in the Mask Interrupt registers. In case of masking a certain interrupt source the interrupt is not produced, but the source of interrupt bit is still set in interrupt registers. ams Datasheet [v1-13] 2015-Jun-18 Page 47 Document Feedback AS3911B − Application Information Figure 37: IRQ Output Name Signal Signal Level Description IRQ Digital output CMOS Interrupt output pin FIFO Water Level and FIFO Status Registers The AS3911B contains a 96 byte FIFO. In case of transmitting the Control logic shifts the data, which was previously loaded by the external microcontroller to the Framing Block and further to the Transmitter. During reception, the demodulated data is stored in the FIFO and the external microcontroller can download received data once reception was terminated. Transmit and receive capabilities of the AS3911B are not limited by the FIFO size due to a FIFO water level interrupt system. During transmission an interrupt is sent (IRQ due to FIFO water level in the Main Interrupt Register) when the content of data in the FIFO passes from (water level + 1) to water level and the complete transmit frame has not been loaded in the FIFO yet. The external microcontroller can now add more data in the FIFO. The same stands for the reception: when the number of received bytes passes from (water level - 1) to water level an interrupt is sent to inform the external controller that data has to be downloaded from FIFO in order not to lose receive data due to FIFO overflow. During transmission water level IRQ is additionally set in case all transmission bytes have not been written in FIFO yet and if number of bytes written into FIFIO is lower than water level. In this case an IRQ is sent when number of bytes in FIFO drops below 4. It is important to note that FIFO IRQ is not produced while SPI is active in FIFO load or read mode. Due to this the FIFO loading/reading rate has to be higher than Tx/Rx bit rate, once FIFO loading/reading is finished the /SS pin has to be pulled to V DD (logic remains in FIFO load/read mode as long as /SS remains low). In case controller knows that the receive data frame is smaller than the FIFO size the water level interrupt does not have to be served. In such case the water level interrupt can be masked. The external controller has to serve the FIFO faster than data is transmitted or received. Using SCLK frequency which is at least double than the actual receive or transmit bit rate is recommended. There are two settings of the FIFO water level available for receive and transmit in the IO Configuration Register 1. After data reception is terminated the external microcontroller needs to know how much data is still stored in the FIFO: This information is available in the FIFO Status Register 1 and FIFO Status Register 2 which displays number of bytes in the FIFO Page 48 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information which were not read out. FIFO Status Register 1 can also be read while reception and transmission processes are active to get info about current number of bytes in FIFO. In that case user has to take in account that Rx/Tx process is going on and that the number of data bytes in FIFO may have already changed by the time the reading of register is finished. The FIFO Status Register 2 additionally contains two bits which indicate that the FIFO was not correctly served during reception or transmission process (FIFO overflow and FIFO underflow). FIFO overflow is set when too much data is written in FIFO. In case this bit is set during reception the external controller did not react on time on water level IRQ and more than 96 bytes were written in the FIFO. The received data is of course corrupted in such a case. During transmission this means that controller has written more data than FIFO size. The data to be transmitted was corrupted. FIFO underflow is set when data was read from empty FIFO. In case this bit is set during reception the external controller read more data than was actually received. During transmission this means that controller has failed to provide the quantity of data defined in number of transmitted bytes registers on time. Pin MCU_CLK Pin MCU_CLK may be used as clock source for the external microcontroller. Depending on the operation mode either a low frequency clock (32 kHz) from the RC oscillator or the clock signal derived from crystal oscillator is available on pin MCU_CLK. The MCU_CLK output pin is controlled by bits out_c1, out_cl0 and lf_clk_off in the IO Configuration Register 1. Bits out_cl enable the use of pin MCU_CLK as clock source and define the division for the case the crystal oscillator is running (13.56 MHz, 6.78 MHz and 3.39 MHz are available). Bit lf_clk_off controls the use of low frequency clock (32 kHz) in case the crystal oscillator is not running. By default configuration, which is defined at power-up, the 3.39 MHz clock is selected and the low frequency clock is enabled. In case the Transparent mode (see Stream Mode and Transparent Mode) is used the use of MCU_CLK is mandatory since clock which is synchronous to the field carrier frequency is needed to implement receive and transmit framing in the external controller. The use of MCU_CLK is recommended also for the case where the internal framing is used. Using MCU_CLK as the microcontroller clock source generates noise which is synchronous to the reader carrier frequency and is therefore filtered out by the receiver while using some other incoherent clock source may produce noise which perturbs the reception. Use of MCU_CLK is also better for EMC compliance. ams Datasheet [v1-13] 2015-Jun-18 Page 49 Document Feedback AS3911B − Application Information Direct Commands Figure 38: List of Direct Commands Command Code (hex) Command Comments Command Chaining Interrupt after Termination Operation Mode (1) Set Default Puts the AS3911B in default state (same as after power-up) No No all Clear Stops all activities and clears FIFO Yes No en C4 Transmit With CRC Starts a transmit sequence using automatic CRC generation Yes No en, tx_en C5 Transmit Without CRC Starts a transmit sequence without automatic CRC generation Yes No en, tx_en C6 Transmit REQA Transmits REQA command (ISO14443A mode only) Yes No en, tx_en C7 Transmit WUPA Transmits WUPA command (ISO14443A mode only) Yes No en, tx_en C8 NFC Initial Field ON Performs Initial RF Collision avoidance and switch on the field Yes Yes en (2) C9 NFC Response Field ON Performs Response RF Collision avoidance and switch on the field Yes Yes en (2) CA NFC Response Field ON with n=0 Performs Response RF Collision avoidance with n=0 and switch on the field Yes Yes en (2) CB Go to Normal NFC Mode Accepted in NFCIP-1 active communication bit rate detection mode Yes No CC Analog Preset Presets Rx and Tx configuration based on state of Mode Definition Register and Bit Rate Definition Register Yes No all D0 Mask Receive Data Receive after this command is ignored Yes No en, rx_en C1 C2, C3 Page 50 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Command Code (hex) Command Comments Command Chaining Interrupt after Termination Operation Mode (1) Yes No en, rx_en D1 Unmask Receive Data Receive data following this command is normally processed (this command has priority over internal Mask Receive Timer) D2 see note (3) Not used D3 Measure Amplitude Amplitude of signal present on RFI inputs is measured, result is stored in A/D Converter Output Register No Yes en D4 Squelch Performs gain reduction based on the current noise level No No en, rx_en D5 Reset Rx Gain Clears the current Squelch setting and loads the manual gain reduction from Receiver Configuration Register 4 No No en (4) D6 Adjust Regulators Adjusts supply regulators according to the current supply voltage level No Yes en (5) Calibrate Modulation Depth Starts sequence which activates the Tx, measures the modulation depth and adapts it to comply with the specified modulation depth No Yes en D8 Calibrate Antenna Starts the sequence to adjust parallel capacitances connected to TRIMx pins so that the antenna LC tank is in resonance No Yes en D9 Measure Phase Measurement of phase difference between the signal on RFO and RFI No Yes en DA Clear RSSI Clears RSSI bits and restarts the measurement Yes No en DC Transparent Mode Enter in Transparent mode No No en DD Calibrate Capacitive Sensor Calibrates capacitive sensor No Yes see note (6) D7 ams Datasheet [v1-13] 2015-Jun-18 Page 51 Document Feedback AS3911B − Application Information Command Code (hex) Comments Command Chaining Interrupt after Termination Operation Mode (1) Performs Capacitor Sensor Measurement No Yes see note (7) Command DE Measure Capacitance DF Measure Power Supply No Yes en E0 Start General Purpose Timer Yes No en E1 Start Wake-Up Timer Yes No all except wu E2 Start Mask-Receive Timer Yes No see note (8) E3 Start No-Response Timer Yes No en, rx_en FC Test Access Yes No all Other Fx Other codes Enable /W to test registers Reserved for test Not used Note(s) and/or Footnote(s): 1. The ‘Operation Mode’ column in the above table defines which Operation Control Register bits have to be set in order to accept a particular command. 2. After termination of this command I_cat or I_cac IRQ is sent. 3. Was AD Convert in the AS3910. 4. Called Clear Squelch in the AS3910. 5. This command is not accepted in case the external definition of the regulated voltage is selected in the Regulator Voltage Control Register (bit reg_s is set to high). 6. Accepted in all modes in case cs_mcal=0 (Capacitive Sensor Control Register), it is recommended to execute this command in Power-down mode. 7. Accepted in all modes, it is recommended to execute this command in Power-down mode. 8. Accepted only in the Initial NFC Active Target Communication Mode. 9. Called Check Antenna Resonance in the AS3910. 10. Called Measure RF in the AS3910. Page 52 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Set Default This direct command puts the AS3911B in the same state as power-up initialization. All registers are initialized to the default state. The only exception are IO Configuration Register 1, IO Configuration Register 2 and Operation Control Register which are not affected by Set Default command and are only set to default state at power-up. Please note that results of different calibration and adjust commands are also lost. This direct command is accepted in all operating modes. In case this command is sent while en (bit 7 of the Operation Control Register) is not set FIFO and FIFO Status Registers are not cleared. Direct command chaining is not allowed since this command clears all registers. IRQ due to termination of direct command is not produced. Clear This direct command stops all current activities (transmission or reception), clears FIFO, clears FIFO Status Registers and stops all timers except Wake-up timer (in case bit nrt_emv in the General Purpose and No-Response Timer Control Register is set to one, the No-Response Timer is not stopped). It also clears collision and interrupt registers. This command has to be sent first in a sequence preparing a transmission before writing data to be transmitted in FIFO (except in case of direct commands Transmit REQA and Transmit WUPA). This command is accepted in case en (bit 7 of the Operation Control Register) is set and Xtal oscillator frequency is stable. Direct command chaining is possible. IRQ due to termination of direct command is not produced. Transmit Commands All Transmit commands (Transmit With CRC, Transmit Without CRC, Transmit REQA and Transmit WUPA) are only accepted in case the Transmitter is enabled (bit tx_en is set). Before sending commands Transmit With CRC and Transmit Without CRC direct command Clear has to be sent, followed by definition of number of transmitted bytes and writing data to be transmitted in FIFO. Direct commands Transmit REQA and Transmit WUPA are used to transmit ISO14443A commands REQA and WUPA respectively. Sending command Clear before these two commands is not necessary. Direct command chaining is possible. IRQ due to termination of direct command is not produced. ams Datasheet [v1-13] 2015-Jun-18 Page 53 Document Feedback AS3911B − Application Information NFC Field ON Commands These commands are used to perform the RF collision avoidance and switch the field on in case no collision was detected. The Collision avoidance threshold defined in the External Field Detector Threshold Register is used to observe the RF_IN inputs and to determine whether there is some other device, which is emitting the 13.56 MHz field, present close to the AS3911B antenna. In case collision is not detected the reader field is switched on automatically (bit tx_en in the Operation Control Register is set) and an IRQ with I_cat flag in Timer and NFC Interrupt Register is sent after minimum guard time defined by the NFCIP-1 standard to inform the controller that message transmission using a Transmit command can be initiated. In case a presence of external field is detected an IRQ with I_cac flag is sent. In such case a transmission cannot be performed, NFC Field ON command has to be repeated as long as collision is not detected any more. Command NFC Initial Field ON performs Initial Collision Avoidance according to NFCIP-1 standard; number n is defined by bits nfc_n1 and nfc_n0 in Auxiliary Definition Register. Command NFC Response Field ON performs Response Collision Avoidance according to NFCIP-1 standard; number n is defined by bits nfc_n1 and nfc_n0 in Auxiliary Definition Register. Command NFC Response Field ON with n=0, performs Response Collision Avoidance where n is 0. Implemented active delay time is on lower NFCIP-1 specification limit, since the actual active delay time will also include detection of the field deactivation, controller processing delay and sending the NFC Field ON command. Figure 39: Direct Command NFC Initial Field ON RF On TRFW Start TIRFG TIDT n x TRFW Page 54 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Figure 40: Direct Command NFC Response Field ON RF On TRFW Start TARFG TADT n x TRFW Figure 41: Timing Parameters of NFC Field ON Commands Symbol Parameter Value Unit Note TIDT Initial delay time 4096 /fc NFC Initial Field ON TRWF RF waiting time 512 /fc TIRFG Initial guard time >5 ms NFC Initial Field ON TADT Active delay time 768 /fc NFC Response Field ON TARFG Active guard time 1024 /fc NFC Response Field ON This command is accepted in case en (bit 7 of the Operation Control Register) is set and Xtal oscillator frequency and amplitude are stable. Go to Normal NFC Mode This command is used to transition from NFC target bit rate detection mode to normal mode. Additionally it copies the content of the NFCIP Bit Rate Detection Display Register to the Bit Rate Definition Register and correctly sets the bit tr_am in the Auxiliary Definition Register. Analog Preset This command is used to preset Receiver and Transmitter configuration based on state of Bit Rate Definition Register and Bit Rate Definition Register. In case of Sub-carrier bit stream or BPSK bit stream mode, this command should not be used. The list of configuration bits that are preset is given in Figure 42. ams Datasheet [v1-13] 2015-Jun-18 Page 55 Document Feedback AS3911B − Application Information Figure 42: Register Preset Bits Bit Bit Name Function Address 02h: Operation Control Register 5 rx_chn 1: one channel enabled → NFCIP-1 active communication (both initiator and target) 3 tx_en 0: disable TX operation → NFCIP-1 active communication (both initiator and target) Note: In case of any target mode or NFCIP-1 initiator mode bit tx_en is set to 0 to disable transmitter in case it was enabled. In NFCIP-1 mode the switching on of the transmitter field is controlled by dedicated commands. Address 05h: ISO14443A and NFC 106kb/s Settings Register 5 nfc_f0 1: Add SB (F0) and LEN byte during Tx and skip SB (F0) byte during TX → NFCIP-1 active communication (both initiator and target) Address 09h: Auxiliary Definition Register 5 tr_am Tx Modulation type (depends on mode definition and Tx bit rate) 0: OOK → ISO144443A, NFCIP-1 106 kb/s (both initiator and target), NFC Forum Type 1 Tag 1: AM → ISO144443B, FeliCa, NFCIP-1 212 kb/s and 424 kb/s 4 en_fd Enable External Field Detector with Peer Detection threshold 0: All modes except NFCIP-1 active communication 1: NFCIP-1 active communication (both initiator and target) Address 0Ah: Receiver Configuration Register 1 7 ch_sel 6 amd_sel 5 lp2 4 lp1 3 lp0 2 h200 1 h80 0 z12k 0: Enable AM channel → NFCIP-1 active communication (both initiator and target) AM demodulator select (depend on Rx bit rate) 0: Peak detector → All Rx bit rates equal or below fc/16 (848 kb/s) 1: Mixer → All VHBR Rx bit rates (fc/8 and fc/4) Low pass control (depends on mode definition and Rx bit rate) (see Figure 18) First and third stage zero setting (depends on mode definition and Rx bit rate) (see Figure 18) Address 0Ch: Receiver Configuration Register 3 1 lim Clip output of 1st and 2nd stage 0: All modes except NFCIP-1 active communication 1: NFCIP-1 active communication (both initiator and target) 0 rg_nfc Forces gain reduction in 2nd and 3rd gain stage 0: All modes except NFCIP-1 active communication 1: NFCIP-1 active communication (both initiator and target) Page 56 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Mask Receive Data and Unmask Receive Data After the direct command Mask Receive Data the signal rx_on, which enables the RSSI and AGC operation of the Receiver (see also Receiver) is forced to low, processing of the receiver output by the receive data framing block is disabled. This command is useful to mask receiver and receive framing from processing the data when there is actually no input and only a noise would be processed (for example in case where a transponder processing time after receiving a command from the reader is long). Masking of receive is also possible using Mask Receive Timer. Actual masking is a logical or of the two mask receive processes. The direct command Unmask Receive Data is enabling normal processing of the received data (signal rx_on is set high to enable the RSSI and AGC operation), the receive data framing block is enabled. A common use of this command is to enable again the receiver operation after it was masked by the command Mask Receive Data. In case Mask Receive Timer is running while command Unmask Receive Data is received, reception is enabled, Mask Receive Timer is reset. The commands Mask Receive Data and Unmask Receive Data are only accepted when the Receiver is enabled (bit rx_en is set). Direct command chaining is possible. IRQ due to termination of direct command is not produced. Measure Amplitude This command measures the amplitude on the RFI inputs and stores result in the A/D Converter Output Register. When this command is executed the Transmitter and Amplitude Detector are enabled, the output of the Amplitude Detector is multiplexed to the A/D Converter input (the A/D Converter is in absolute mode). The Amplitude Detector conversion gain is 0.6 V INPP / VOUT. One LSB of the A/D converter output represents 13.02 mVpp on the RFI inputs. A 3 Vpp signal, which is maximum allowed level on each of the two RFI inputs, results in 1.8 V output DC voltage and would produce a value of 1110 0110b on the A/D converter output. Duration time: 25 μs max. This command is accepted in case en (bit 7 of the Operation Control Register) is set and Xtal oscillator frequency is stable. Direct command chaining is not possible. IRQ due to termination of direct command is produced after command execution is terminated. Squelch This direct command is intended to avoid demodulation problems of transponders which produce a lot of noise during data processing. It can also be used in a noisy environment. The operation of this command is explained in Squelch. ams Datasheet [v1-13] 2015-Jun-18 Page 57 Document Feedback AS3911B − Application Information Duration time: 500 μs max. This command is only accepted when the Transmitter and the Receiver are operating. Command is actually executed only in case signal rx_on is low. Direct command chaining is not possible. IRQ due to termination of direct command is not produced. Reset Rx Gain This command initializes the AGC, Squelch and RSSI block. Sending this command stops a squelch process in case it is going on, clears the current Squelch setting and loads the manual gain reduction from Receiver Configuration Register 4. This command is accepted in case en (bit 7 of the Operation Control Register) is set and Xtal oscillator frequency is stable. Direct command chaining is possible. IRQ due to termination of direct command is not produced. Adjust Regulators When this command is sent the power supply level of V DD is measured in maximum load conditions and the regulated voltage reference is set 250 mV below this measured level to assure maximum possible stable regulated supply (see Power Supply System). Using this command increases the system PSSR. At the beginning of execution of this command, both the receiver and transmitter are switched on to have the maximum current consumption, the regulators are set to the maximum regulated voltage (5.1 V in case of 5 V supply and 3.4 V in case of 3.3 V supply mode). After 300 μs VSP_RF is compared to V DD, in case VSP_RF is not at least 250 mV lower the regulator setting is reduced for one step (120 mV in case of 5 V supply and 100 mV in case of 3.3 V supply mode) and measurement is done after next 300 μs. Procedure is repeated until VSP_RF drops at least 250 mV below V DD or until minimum regulated voltage (3.9 V in case of 5 V supply and 2.4 V in case of 3.3 V supply mode) is reached. Duration time: 5 ms max. This command is accepted in case en (bit 7 of the Operation Control Register) is set and Xtal oscillator frequency is stable. This command is not accepted in case the external definition of the regulated voltage is selected in the Regulator Voltage Control Register (bit reg_s is set to H) Direct command chaining is not possible. IRQ due to termination of direct command is produced after command execution is terminated. Page 58 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Calibrate Modulation Depth Starts a patent pending sequence, which activates the transmission, measures the modulation depth and adapts it to comply with the modulation depth specified in the AM Modulation Depth Control Register. When calibration procedure is finished result is displayed in the AM Modulation Depth Display Register. Please refer to AM Modulation Depth: Definition and Calibration for details about setting the AM modulation depth and running this command. Duration time: 275 μs max. This command is accepted in case en (bit 7 of the Operation Control Register) is set and Xtal oscillator frequency is stable. Direct command chaining is not possible. IRQ due to termination of direct command is produced after command execution is terminated. Calibrate Antenna Sending this command starts a sequence which adjusts the parallel capacitances connected to TRIMx pins so that the antenna LC tank is in resonance. See Antenna Tuning for details. Duration time: 250 μs max. This command is accepted in case en (bit 7 of the Operation Control Register) is set and Xtal oscillator frequency is stable. Measure Phase This command measures the phase difference between the signals on the RFO outputs and the signals on the RFI inputs and stores the result in the A/D Converter Output Register. During execution of the direct command Measure Phase the Transmitter and Phase Detector are enabled, the Phase Detector output is multiplexed on the input of A/ D converter, which is set in relative mode. Since the A/D converter range is from 1/6 VSP_A to 5/6 VSP_A the actual phase detector range is from 30º to 150º. Values below 30º result in FFh while values above 150º result in 00 h. 1 LSB of the A/D conversion output represents 0.13% of carrier frequency period (0.468°). The result of A/D conversion is in case of 90º phase shift in the middle of range (1000 0000b or 0111 1111b). Value higher than 1000 0000b means that phase detector output voltage is higher than VSP_A/2, which corresponds to case with phase shift lower than 90º. In the opposite case, when the phase shift is higher than 90º, the result of A/D conversion is lower than 0111 1111b. For example, the phase difference of 135º depicted in Figure 21 results in 0.75 VSP_A, result stored in A/D converter is 31 d (1Fh). ams Datasheet [v1-13] 2015-Jun-18 Page 59 Document Feedback AS3911B − Application Information The phase measurement result can be calculating using the following formulas: 0 ≤ φ ≤ 30 : result[dec] = 255 30 < φ < 150 : angle _ deg rees = 30.0 + ((255.0 − u _ angle) / 255.0) *120.0) 150 ≥ φ ≥ 180 : result[dec] = 0 Duration time: 25 μs max. This command is accepted in case en (bit 7 of the Operation Control Register) is set and Xtal oscillator frequency is stable. Direct command chaining is not possible. IRQ due to termination of direct command is produced after command execution is terminated. Clear RSSI The Receiver automatically clears the RSSI bits in the Receiver State Display Register and starts to measure the RSSI of the received signal when the signal rx_on is asserted. Since the RSSI bits store peak value (peak-hold type) eventual variation of the receiver input signal will not be followed (this may happen in case of long message or test procedure). The direct command Clear RSSI clears the RSSI bits in the Receiver State Display Register, the RSSI measurement is restarted (in case of course rx_on is still high). This command is accepted in case en (bit 7 of the Operation Control Register) is set and Xtal oscillator frequency is stable. Direct command chaining is possible. IRQ due to termination of direct command is not produced. Transparent Mode Enter in the Transparent mode. The Transparent mode is entered on the rising edge of signal /SS and is maintained as long as signal /SS is kept high. See Transparent Mode for more details. This command is accepted in case en (bit 7 of the Operation Control Register) is set and Xtal oscillator frequency is stable. Calibrate Capacitive Sensor This command calibrates the Capacitive Sensor. See Capacitive Sensor for more details. Duration time: 3 ms max. This command is executed in case capacitive sensor automatic calibration mode is set (all bits cs_mcal in the Capacitive Sensor Control Registerare set to 0). In order to avoid interference with Xtal oscillator and reader magnetic field it strongly recommended to use this command in Power-down mode only. Direct command chaining is not possible. IRQ due to termination of direct command is produced after command execution is terminated. Page 60 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Measure Capacitance This command performs the capacitance measurement. See Capacitive Sensor for more details. Duration time: 250 μs max. In order to avoid interference with Xtal oscillator and reader magnetic field it strongly recommended to use this command in Power-down mode only. Direct command chaining is not possible. IRQ due to termination of direct command is produced after command execution is terminated. Measure Power Supply This command performs the power supply measurement. Configuration bits mpsv1 and mpsv0 of the Regulator Voltage Control Register define which power supply is measured (V DD, VSP_A, VSP_D and VSP_RF can be measured). Result of measurement is stored in the A/D Converter Output Register. During the measurement the selected supply input is connected to a 1/3 resistive divider output of which is multiplexed to A/D converter in absolute mode. Due to 1/3 division one LSB represents 23.438 mV. Duration time: 25 μs max. This command is accepted in case en (bit 7 of the Operation Control Register) is set and Xtal oscillator frequency is stable. Direct command chaining is not possible. IRQ due to termination of direct command is produced after command execution is terminated. Start Timers See Timers. Test Access The AS3911B does not contain any dedicated test pins. A direct command Test Access is used to enable RW access of test registers and entry in different test modes. Pins CSI and CSO are used as test pins. Test Mode Entry and Access to Test Registers Test registers are not part of normal SPI register address space. After sending a direct command Test Access , test regisers can be accessed using normal Read/Write Register SPI command. Access to test register is possible in a chained command sequence where first command Test Access is sent, followed by read/write access to test registers using auto increment feature. After SPI interface reset (SS toggle) the content of test registers is kept. Test register are set to default state at power-up and by sending commands Set Default and Clear Test Registers. ams Datasheet [v1-13] 2015-Jun-18 Page 61 Document Feedback AS3911B − Application Information Figure 43: Analog Test and Observation Register Test Address 01h: Analog Test and Observation Register Bit Name Default 7 tana_7 0 Do not change 6 tana_6 0 Do not change 5 tana_5 0 Do not change 4 Type: RW Function Comments Not used 3 tana_3 0 2 tana_2 0 1 tana_1 0 0 tana_0 0 These test modes are also intended for observation in normal mode. Several modes of this register are also available when analog test mode is not set. See Figure 44 Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after commands Set Default and Clear Test Registers Figure 44: Test Access Register - Tana Signal Selection Of CSI and CSO Pins Tana_ Pin CSI Pin CSO 3 2 1 0 Pin Type Functionality Pin Type 0 0 0 1 AO Analog output of AM channel (before digitizer) DO Digital output of AM channel (after digitizer) Normal operation 0 0 1 0 AO Analog output of PM channel (before digitizer) DO Digital output of PM channel (after digitizer) Normal operation 0 0 1 1 AO Analog output of AM channel (before digitizer) AO Analog output of PM channel (before digitizer) Normal operation 0 1 0 0 DO Digital output of AM channel (after digitizer) DO Digital output of PM channel (after digitizer) Normal operation Analog signal after second stage Normal operation PM channel if enabled, AM if PM is not enabled 0 1 0 Page 62 Document Feedback 1 AO Analog signal after first stage AO Functionality Comment ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Tana_ 3 2 1 Pin CSI 0 Pin Type Functionality 1 0 0 1 DO Channel selection from logic 1 0 1 0 DO Digital TX modulation signal Pin CSO Pin Type Functionality Comment Collision avoidance detectors are enabled Analog part of channel selection DO Collision avoidance detector output DO Select PM Registers The 6-bit register addresses below are defined in the hexadecimal notation. The possible address range is from 00 h to 3Fh. There are two types of registers implemented in the AS3911B: configuration registers and display registers. The configuration registers are used to configure the AS3911B. They can be written and read through the SPI (RW). The display registers are read only (RO); they contain information about the AS3911B internal state. Registries are set to their default state at power-up and after sending direct command Set Default. The only exceptions are the IO Configuration Register 1 and the IO Configuration Register 2 which are only set to default state at power-up. Configuration bits of these two registries are related to hardware configuration which is in most cases not going to change during the operation. Figure 45: Register Description Address[hex] Content Comment Type IO Configuration Registers 00 IO Configuration Register 1 01 IO Configuration Register 2 Set to default state only at power-up RW RW Operation Control and Mode Definition Registers 02 Operation Control Register 03 Mode Definition Register 04 Bit Rate Definition Register ams Datasheet [v1-13] 2015-Jun-18 Set to default state only at power-up RW RW Page 63 Document Feedback AS3911B − Application Information Address[hex] Content Comment Type Configuration Registers 05 ISO14443A and NFC 106kb/s Settings Register RW 06 ISO14443B Settings Register 1 RW 07 ISO14443B and FeliCa Settings Register RW 08 Stream Mode Definition Register RW 09 Auxiliary Definition Register RW 0A Receiver Configuration Register 1 RW 0B Receiver Configuration Register 2 RW 0C Receiver Configuration Register 3 RW 0D Receiver Configuration Register 4 RW Timer Definition Registers 0E Mask Receive Timer Register RW 0F No-Response Timer Register 1 RW 10 No-Response Timer Register 2 RW 11 General Purpose and No-Response Timer Control Register RW 12 General Purpose Timer Register 1 RW 13 General Purpose Timer Register 2 RW Interrupt and Associated Reporting Registers 14 Mask Main Interrupt Register RW 15 Mask Timer and NFC Interrupt Register RW 16 Mask Error and Wake-Up Interrupt Register RW 17 Main Interrupt Register R 18 Timer and NFC Interrupt Register R 19 Error and Wake-Up Interrupt Register R 1A FIFO Status Register 1 R 1B FIFO Status Register 2 R 1C Collision Display Register R Page 64 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Address[hex] Content Comment Type Definition of Number of Transmitted Bytes 1D Number of Transmitted Bytes Register 1 RW 1E Number of Transmitted Bytes Register 2 RW NFCIP Bit Rate Detection Display Register 1F NFCIP Bit Rate Detection Display Register R A/D Converter Output Register 20 A/D Converter Output Register R Antenna Calibration Registers 21 Antenna Calibration Control Register RW 22 Antenna Calibration Target Register RW 23 Antenna Calibration Display Register R AM Modulation Depth and Antenna Driver Registers 24 AM Modulation Depth Control Register RW 25 AM Modulation Depth Display Register R 26 RFO AM Modulated Level Definition Register RW 27 RFO Normal Level Definition Register RW External Field Detector Threshold Registers 29 External Field Detector Threshold Register RW Regulator Registers 2A Regulator Voltage Control Register 2B Regulator and Timer Display Register RW R Receiver State Display Registers 2C RSSI Display Register R 2D Gain Reduction State Register R Capacitive Sensor Registers 2E Capacitive Sensor Control Register RW 2F Capacitive Sensor Display Register R Auxiliary Display Register 30 ams Datasheet [v1-13] 2015-Jun-18 Auxiliary Display Register R Page 65 Document Feedback AS3911B − Application Information Address[hex] Content Comment Type Wake-Up Registers 31 Wake-Up Timer Control Register RW 32 Amplitude Measurement Configuration Register RW 33 Amplitude Measurement Reference Register RW 34 Amplitude Measurement Auto-Averaging Display Register R 35 Amplitude Measurement Display Register R 36 Phase Measurement Configuration Register RW 37 Phase Measurement Reference Register RW 38 Phase Measurement Auto-Averaging Display Register R 39 Phase Measurement Display Register R 3A Capacitance Measurement Configuration Register RW 3B Capacitance Measurement Reference Register RW 3C Capacitance Measurement Auto-Averaging Display Register R 3D Capacitance Measurement Display Register R IC Identity Register 3F Page 66 Document Feedback IC Identity Register R ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information IO Configuration Register 1 Figure 46: IO Configuration Register 1 Address 00h: IO Configuration Register 1 Type: RW Bit Name Default 7 single 0 1: Only one RFO driver will be used Choose between single and differential driving of antenna 6 rfo2 0 0: RFO1, RFI1 1: RFO2, RFI2 Choose which output driver and which input will be used in case of single driving 5 fifo_lr 0 0: 64 1: 80 FIFO water level for receive 4 fifo_lt 0 0: 32 1: 16 FIFO water level for transmit 3 osc 1 0: 13.56 MHz Xtal 1: 27.12 MHz Xtal Selector for crystal oscillator Use of VHBR is only possible with 27.12 MHz Xtal 2 1 0 out_cl1 out_cl0 lf_clk_off 0 Function Comments out_cl1 out_cl0 MCU_CLK 0 0 3.39 MHZ 0 1 6.78 MHZ 1 0 13.56 MHZ 1 1 disabled 0 0 1: No LF clock on MCU_CLK Selection of clock frequency on MCU_CLK output in case Xtal oscillator is running. In case of “11” MCU_CLK output is permanently low. By default the 32 kHz LF clock is present on MCU_CLK output when Xtal oscillator is not running and the MCU_CLK output is not disabled. Note(s) and/or Footnote(s): 1. Default setting is set at power-up only. ams Datasheet [v1-13] 2015-Jun-18 Page 67 Document Feedback AS3911B − Application Information IO Configuration Register 2 Figure 47: IO Configuration Register 2 Address 01h: IO Configuration Register 2 Bit 7 6 Name sup3 V vspd_off Default 0 0 5 Function Comments 0: 5 V supply 1: 3.3 V supply 5 V supply, range: 4.1 V to 5.5 V 3.3 V supply, range: 2.4 V to 3.6 V min. 3.0V for VHBR 1: Disable VSP_D regulator Used for low cost applications. When this bit is set: At 3 V or 5 V supply VSP_D and VSP_A shall be shorted externally At 3.3 V applications VSP_D can alternatively be supplied from VDD in case VSP_A is not more than 300 mV lower then VDD Not used 4 miso_pd2 0 1: Pull-down on MISO, when /SS is low and MISO is not driven by the AS3911B 3 miso_pd1 0 1: Pull-down on MISO when /SS is high 2 io_18 0 1: Increase MISO driving level in case of 1.8 V VDD_IO 1 0 Type: RW Not used slow_up 0 1: Slow ramp at Tx on ≥ 10μs 10% to 90%, for B Note(s) and/or Footnote(s): 1. Default setting is set at power-up only. Page 68 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Operation Control Register Figure 48: Operation Control Register Address 02h: Operation Control Register Bit Name Default 7 en 0 1: Enables oscillator and regulator (Ready mode) 6 rx_en 0 1: Enables Rx operation 0 0: Both, AM and PM, channels enabled 1: One channel enabled In case only one Rx channel is enabled, selection is done by the Receiver Configuration Register 1 bit ch_sel 0: Automatic channel selection 1: Manual channel selection In case both Rx channels are enabled, it chooses the method of channel selection, manual selection is done by the Receiver Configuration Register 1 bit ch_sel 5 4 rx_chn rx_man 0 Function Type: RW Comments 3 tx_en 0 1: Enables Tx operation This bit is automatically set by NFC Field ON commands and reset in NFC active communication modes after transmission is finished 2 wu 0 1: Enables Wake-up mode According to settings in Wake-Up Timer Control Register 1 Not used 0 Note(s) and/or Footnote(s): 1. Default setting is set at power-up only. ams Datasheet [v1-13] 2015-Jun-18 Page 69 Document Feedback AS3911B − Application Information Mode Definition Register Figure 49: Mode Definition Register Address 03h: Mode Definition Register Bit Name Default 7 targ 0 6 om3 0 5 om2 0 4 om1 0 3 om0 1 2 0 1 0 Type: RW Function Comments 0: Initiator 1: Target Refer to Initiator Operation Modes and Target Operation Modes Selection of operation mode. Different for initiator and target mode. Not used 0 nfc_ar Automatic start of Response RF Collision Avoidance sequence 0 Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. Figure 50: Initiator Operation Modes Initiator Operation Modes om3 om2 om1 om0 0 0 0 0 NFCIP-1 active communication 0 0 0 1 ISO14443A 0 0 1 0 ISO14443B 0 0 1 1 FeliCa 0 1 0 0 NFC Forum Type 1 Tag (Topaz) 1 1 1 0 Sub-carrier stream mode 1 1 1 1 BPSK stream mode Other combinations Comment Not used Note(s) and/or Footnote(s): 1. In case an operation mode which is not supported is selected, the Tx/Rx operation is disabled. Page 70 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Figure 51: Target Operation Modes Target Operation Modes om3 om2 om1 om0 0 0 0 0 NFCIP-1 active communication, bit rate detection mode 0 0 0 1 NFCIP-1 active communication, normal mode Other combinations Comment Not used Note(s) and/or Footnote(s): 1. In case an operation mode which is not supported is selected, the Tx/Rx operation is disabled. Bit Rate Definition Register Figure 52: Bit Rate Definition Register Address 04h: Bit Rate Definition Register Bit Name Default 7 tx_rate3 0 6 tx_rate2 0 5 tx_rate1 0 4 tx_rate0 0 3 rx_rate3 0 2 rx_rate2 0 1 rx_rate1 0 0 rx_rate0 0 Function Type: RW Comments Selects bit rate for Tx Refer to Bit Rate Coding Selects bit rate for Rx in case selected protocol allows different bit rates for Rx and Tx Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. 2. Automatically loaded by direct command Go to Normal NFC Mode. ams Datasheet [v1-13] 2015-Jun-18 Page 71 Document Feedback AS3911B − Application Information Figure 53: Bit Rate Coding Bit Rate Coding rate3 rate2 rate1 rate0 Bit rate [kbit/s] 0 0 0 0 fc/128 (~106) 0 0 0 1 fc/64 (~212) 0 0 1 0 fc/32 (~424) 0 0 1 1 fc/16 (~848) 0 1 0 0 fc/8 (~1695) 0 1 0 1 fc/4 (~3390) 0 1 1 0 fc/2 (~6780) Other combinations Comment VHBR Tx is supported only for ISO14443B mode VHBR Rx is supported only for fc/8 and fc/4 Not used Note(s) and/or Footnote(s): 1. In case a bit rate which is not supported is selected, the Tx/Rx operation is disabled. ISO14443A and NFC 106kb/s Settings Register Figure 54: ISO14443A and NFC 106kb/s Settings Register Address 05h: ISO14443A and NFC 106kb/s Settings Register Bit Name Default 7 no_tx_par 0 1: No parity bit is generated during Tx Data stream is taken from FIFO, transmit has to be done using command Transmit Without CRC 6 no_rx_par 0 1: Receive without parity and CRC When set to 1 received bit stream is put in the FIFO, no parity and CRC detection is done 5 nfc_f0 0 1: Support of NFCIP-1 Transport Frame format Add SB (F0) and LEN bytes during Tx and skip SB (F0) byte during Rx in NFC Active communication mode 4 p_len3 0 3 p_len2 0 2 p_len1 0 Refer to ISO14443A Modulation Pulse Width Modulation pulse width; defined in number of 13.56 MHz clock periods. 1 p_len0 0 Page 72 Document Feedback Function Type: RW Comments ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Address 05h: ISO14443A and NFC 106kb/s Settings Register Bit Name Default 0 antcl 0 Type: RW Function Comments 1: ISO14443 anticollision frame Has to be set to 1 when ISO14443A bit oriented anticollision frame is sent Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. 2. no_tx_par and no_rx_par are used to send and receive custom frames like Mifare™ Classic frames. Figure 55: ISO14443A Modulation Pulse Width ISO14443A Modulation Pulse Width p_len3 p_len2 p_len1 Pulse Width in Number of 1/fc for Different Bit Rates p_len0 fc/128 fc/64 fc/32 fc/16 0 1 1 1 42 0 1 1 0 41 20 0 1 0 1 40 21 0 1 0 0 39 22 13 0 0 1 1 38 21 12 8 0 0 1 0 37 20 11 7 0 0 0 1 36 19 10 6 0 0 0 0 35 18 9 5 1 1 1 1 34 17 8 4 1 1 1 0 33 16 7 3 1 1 0 1 32 15 6 2 1 1 0 0 31 14 5 1 0 1 1 30 13 1 0 1 0 29 12 1 0 0 1 28 1 0 0 0 27 ams Datasheet [v1-13] 2015-Jun-18 Page 73 Document Feedback AS3911B − Application Information ISO14443B Settings Register 1 Figure 56: ISO14443B Settings Register Address 06h: ISO14443B Settings Register 1 Bit 7 Name egt2 Default Function egt1 0 5 egt0 0 Comments egt2 egt1 egt0 Number of EGT 0 0 0 0 0 0 1 1 . . . . . . . . 1 1 0 6 1 1 1 6 0 6 Type: RW EGT time defined in number of etu 4 sof_0 0 0 → 10 etu, 1 → 11 etu SOF, number of etu with logic 0 (10 or 11) 3 sof_1 0 0 → 2 etu, 1 → 3 etu SOF, number of etu with logic 1 (2 or 3) 2 eof 0 0 → 10 etu, 1 → 11 etu EOF, number of etu with logic 0 (10 or 11) 1 half 0 rx_st_om 1: SOF 10.5, 2.5, EOF: 10.5 Sets SOF and EOF settings in middle of specification 1: Start/stop bit omission for Rx SOF= fixed to 10 low - 2 high, EOF not defined, put in FIFO last full byte (2) Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. 2. Start/stop bit omission for Tx can be implemented by using Stream mode. Page 74 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information ISO14443B and FeliCa Settings Register Figure 57: ISO14443B and FeliCa Settings Register Address 07h: ISO14443B and FeliCa Settings Register Bit Name Default 7 tr1_1 0 6 tr1_0 0 Type: RW Function Comments Refer to Minimum TR1 Coding 5 no_sof 0 1: No SOF PICC to PCD According to ISO14443-3 chapter 7.10.3.3 Support of B’ 4 no_eof 0 1: No EOF PICC to PCD According to ISO14443-3 chapter 7.10.3.3 3 eof_12 0 0: PICC EOF 10 to 11 etu 1: PICC EOF 10 to 12 etu Support of B’ (2) 2 phc_th 0 1: Increased tolerance of phase change detection 1 f_p1 0 0 f_p0 0 FeliCa preamble length (valid also for NFCIP-1 active communication bit rates 242 and 484 kb/s) 00: 48 01: 64 10: 80 11: 96 Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. 2. Detection of EOF requires larger tolerance range for bit rates with only one sub-carrier frequency period per bit (fc/16 and higher). Due to this it is not possible to distinguish between EOF with 11 and 12 etu and setting this bit has no impact on EOF detection. Figure 58: Minimum TR1 Codings Minimum TR1 Coding Minimum TR1 for a PICC to PCD Bit Rate tr1_1 tr1_0 fc / 128 > fc / 128 0 0 80 / fs 80 / fs 0 1 64 / fs 32 / fs 1 0 Not used Not used 1 1 Not used Not used Note(s) and/or Footnote(s): 1. TR1 is defined in number of sub-carrier cycles, therefore at VHBR the absolute time becomes shorter. ams Datasheet [v1-13] 2015-Jun-18 Page 75 Document Feedback AS3911B − Application Information Stream Mode Definition Register Figure 59: Stream Mode Definition Register Address 08h: Stream Mode Definition Register Bit Name 7 Default Type: RW Function Comments 0 6 scf1 0 5 scf0 0 4 scp1 0 3 scp0 Refer to Sub-Carrier Frequency Definition for Sub-Carrier and BPSK Stream Mode 0 2 stx2 0 1 stx1 0 0 stx0 scp1 scp0 number of pulses 0 0 1 (BPSK only) 0 1 2 1 0 4 1 1 8 Refer to Definition of Time Period for Stream Mode Tx Modulator Control Sub-carrier frequency definition for Sub-carrier and BPSK stream mode Number of sub-carrier pulses in report period for Sub-carrier and BPSK stream mode Definition of time period for Tx modulator control (for Sub-carrier and BPSK stream mode) Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. Figure 60: Sub-Carrier Frequency Definition for Sub-Carrier and BPSK Stream Mode Sub-Carrier Frequency Definition for Sub-Carrier and BPSK Stream Mode scf1 scf0 Sub-Carrier Mode BPSK Mode 0 0 fc/64 (212 kHz) fc/16 (848 kHz) 0 1 fc/32 (424 kHz) fc/8 (1695 kHz) 1 0 fc/16 (848 kHz) fc/4 (3390 kHz) 1 1 fc/8 (1695 kHz) Not used Page 76 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Figure 61: Definition of Time Period for Stream Mode Tx Modulator Control Definition of Time Period for Stream Mode Tx Modulator Control stx2 stx1 stx0 Time Period 0 0 0 fc/128 (106 kHz) 0 0 1 fc/64 (212 kHz) 0 1 0 fc/32 (424 kHz) 0 1 1 fc/16 (848 kHz) 1 0 0 fc/8 (1695 kHz) 1 0 1 fc/4 (3390 kHz) 1 1 0 fc/2(6780 kHz) 1 1 1 not used ams Datasheet [v1-13] 2015-Jun-18 Page 77 Document Feedback AS3911B − Application Information Auxiliary Definition Register Figure 62: Auxiliary Definition Register Address 09h: Auxiliary Definition Register Bit 7 6 5 Name no_crc_rx crc_2_fifo tr_am Default Type: RW Function Comments 0 1: Receive without CRC Valid for all protocols, for ISO14443A REQA, WUPA and anticollision receive without CRC is done automatically (2) 0 1: Make CRC check, but put CRC bytes in FIFO and add them to number of receive bytes Needed for EMV compliance 0 0: OOK, 1: AM Set automatically by command Analog Preset, can be modified by register write, has to be defined for transparent and bit stream mode Tx (3) External Field Detector with Peer Detection threshold is activated. Preset for NFCIP-1 active communication mode Valid for all protocols using OOK modulation (also in Transparent mode) 4 en_fd 0 1: Enable External Field Detector 3 ook_hr 0 1: Puts RFO driver in three-state during OOK modulation 1: BPSK fc/32: more tolerant BPSK decoder for bit rate fc/32, ISO14443A fc/128, NFCIP-1 fc/128: more tolerant processing of first byte 2 rx_tol 1 1 nfc_n1 0 0 nfc_n0 0 Definition on n for direct commands NFC Initial Field ON and NFC Response Field ON Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. 2. Receive without CRC is done automatically in case REQA and WUPA commands are sent using direct commands Transmits REQA command and Transmits WUPA command, respectively, and in case anticollision is performed by setting bit antcl. 3. Automatic preset of the tr_am 4. 0: OOK ® ISO144443A, NFCIP-1 106 kb/s, NFC Forum Type 1 Tag 5. 1: AM ® ISO144443B, FeliCa, NFCIP-1 212 and 424 kb/s 6. While en_fd is set, and field detected in AP2P mode, this timer is reserved for internal use. Page 78 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Receiver Configuration Register 1 Figure 63: Receiver Configuration Register 1 Address 0Ah: Receiver Configuration Register 1 (Filter and Demodulator Settings) Bit Name Default Function Type: RW Comments 7 ch_sel 0 0: Enable AM channel 1: Enable PM channel In case only one Rx channel is enabled in the Operation Control Register it defines which channel is enabled. In case both channels are enabled and manual channel selection is active, it defines which channel is used for receive framing. 6 amd_sel 0 0: Peak detector 1: Mixer AM demodulator type select, VHBR automatic preset to mixer 5 lp2 0 4 lp1 0 3 lp0 0 2 h200 0 1 h80 0 0 z12k 0 Low pass control (Figure 16) First and third stage zero setting (see Figure 17) For automatic and other recommended filter settings, refer to Figure 18. Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. ams Datasheet [v1-13] 2015-Jun-18 Page 79 Document Feedback AS3911B − Application Information Receiver Configuration Register 2 Figure 64: Receiver Configuration Register 2 Address 0Bh: Receiver Configuration Register 2 Bit Name Default Function 7 rx_lp 0 1: Low power receiver operation 6 lf_op 0 0: Differential LF operation 1: LF input split (RFI1 to AM channel, RFI2 to PM channel) 5 lf_en 0 1: LF signal on receiver input 4 agc_en 1 1: AGC is enabled Type: RW Comments 3 agc_m 1 0: AGC operates on first eight sub-carrier pulses 1: AGC operates during complete receive period 2 agc_alg 0 0: Algorithm with preset is used 1: Algorithm with reset is used Algorithm with preset is recommended for protocols with short SOF (like ISO14443A fc/128) 1 sqm_dyn 1 1: Automatic squelch activation after end of Tx Activated 18.88 μs after end of Tx, terminated with Mask Receive Timer expire 0 pmix_cl 0 0: RFO 1: Internal signal PM demodulator mixer clock source, in single mode internal signal is always used Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. Page 80 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Receiver Configuration Register 3 Figure 65: Receiver Configuration Register 3 Address 0Ch: Receiver Configuration Register 3 (1st stage gain settings) Bit Name Default 7 rg1_am2 1 6 rg1_am1 1 5 rg1_am0 0 4 rg1_pm2 1 Type: RW Function Comments Gain reduction/boost in first gain stage of AM channel. 0: Full gain 1-6: Gain reduction 2.5 dB per step (15 dB total) 7: Boost +5.5 dB Gain reduction/boost in first gain stage of PM channel. 0: Full gain 1-6: Gain reduction 2.5 dB per step (15 dB total) 7: Boost +5.5 dB 3 rg1_pm1 1 2 rg1_pm0 0 1 lim 0 1: Clip output of 1st and 2nd stage Signal clipped to 0.6 V, preset for NFCIP-1 active communication mode 0 1: Forces gain reduction in 2nd and 3rd gain stage to -6 dB and maximum comparator window Preset for NFCIP-1 active communication mode. After clearing this bit, receiver must be restarted. 0 rg_nfc Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. ams Datasheet [v1-13] 2015-Jun-18 Page 81 Document Feedback AS3911B − Application Information Receiver Configuration Register 4 Figure 66: Receiver Configuration Register 4 Address 0Dh: Receiver Configuration Register 4 (2nd and 3rd stage gain settings) Function Type: RW Bit Name Default 7 rg2_am3 0 6 rg2_am2 0 5 rg2_am1 0 4 rg2_am0 0 reduce the gain in 2nd and 3rd gain stage also in 3 dB steps. 3 rg2_pm3 0 2 rg2_pm2 0 1 rg2_pm1 0 Values from 0h to Ah are used. Other values are not used. Settings 1h to 4h reduce gain by increasing the digitizer window in 3dB steps, values from 5h to Ah additionally 0 rg2_pm0 0 AM channel: Gain reduction in second and third stage and digitizer PM channel: Gain reduction in second and third stage and digitizer Comments Values from 0h to Ah are used. Other values are not used. Settings 1h to 4h reduce gain by increasing the digitizer window in 3dB steps, values from 5h to Ah additionally reduce the gain in 2nd and 3rd gain stage also in 3 dB steps. Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. 2. Sending of direct command Reset Rx Gain is necessary to load the value of this register into AGC, Squelch, and RSSI block. Page 82 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Mask Receive Timer Register Figure 67: Mask Receive Timer Register Address 0Eh: Mask Receive Timer Register Bit Name Default 7 mrt7 0 6 mrt6 0 5 mrt5 0 4 mrt4 0 3 mrt3 1 2 mrt2 0 1 mrt1 0 0 mrt0 0 Type: RW Function Comments Defined in steps of 64/fc (4.72 μs). Range from 256/fc (~18.88 μs) to 16320/fc (~1.2 ms) Timeout = mrt<7:0> * 64/fc Timeout (0 ≤ mrt<7:0> ≤ 4) = 4 * 64/fc (18.88 μs) In NFCIP-1 bit rate detection mode one step is 512/fc (37.78 μs) Defines time after end of Tx during which receiver output is masked (ignored). For the case of ISO14443A 106 kbit/s the Mask Receive Timer is defined according to PCD to PICC frame delay time definition, where mrt<7:0> define number of n/2 steps. Minimum mask receive time of 18.88 μs covers the transients in receiver after end of transmission. Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. 2. In NFCIP-1 bit rate detection mode, the clock of the Mask Receive Timer is additionally divided by eight (one count is 512/fc) to cover range up to ~9.6 ms. No-Response Timer Register 1 Figure 68: No-Response Timer Register 1 Address 0Fh: No-Response Timer Register 1 Bit Name Default 7 nrt15 0 6 nrt14 0 5 nrt13 0 4 nrt12 0 3 nrt11 0 2 nrt10 0 1 nrt9 0 0 nrt8 0 Function No-Response Timer definition MSB bits Defined in steps of 64/fc (4.72 μs). Range from 0 to 309 ms In case bit nrt_step in General Purpose and No-Response Timer Control Register is set the step is changed to 4096/fc Type: RW Comments Defines timeout after end of Tx. In case this timeout expires without detecting a response a No-response interrupt is sent. In NFC mode the NO response timer is started only when external field is detected" with "In the NFCIP-1 active communication mode the No-Response Timer is automatically started when the transmitter is turned off after the message has been sent All 0: No-Response timer is not started. No-Response timer is reset and restarted with Start No-Response Timer direct command. Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. ams Datasheet [v1-13] 2015-Jun-18 Page 83 Document Feedback AS3911B − Application Information No-Response Timer Register 2 Figure 69: No-Response Timer Register 2 Address 10h: No-Response Timer Register 2 Bit Name Default 7 nrt7 0 6 nrt6 0 5 nrt5 0 4 nrt4 0 3 nrt3 0 2 nrt2 0 1 nrt1 0 0 nrt0 0 Function Type: RW Comments No-Response Timer definition LSB bits Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. General Purpose and No-Response Timer Control Register Figure 70: General Purpose and No-Response Timer Control Register Address 11h: General Purpose and No-Response Timer Control Register Bit Name Default 7 gptc2 0 6 gptc1 0 5 gptc0 0 4 0 3 0 2 0 Page 84 Document Feedback Function Type: RW Comments Defines the timer trigger source. Refer to Timer Trigger Source. ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Address 11h: General Purpose and No-Response Timer Control Register Bit Name Default Function 1 nrt_emv 0 1: EMV mode of No-Response timer 0 nrt_step 0 0: 64/fc 1: 4096/fc Type: RW Comments Selects the No-Response Timer step. Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. Figure 71: Timer Trigger Source Timer Trigger Source gptc2 gptc1 gptc0 Trigger Source 0 0 0 No trigger source, start only with direct command Start General Purpose Timer. 0 0 1 End of Rx (after EOF) 0 1 0 Start of Rx 0 1 1 End of Tx in NFC mode, when General Purpose Timer expires the field is switched off 1 0 0 1 0 1 1 1 0 1 1 1 Not used ams Datasheet [v1-13] 2015-Jun-18 Page 85 Document Feedback AS3911B − Application Information General Purpose Timer Register 1 Figure 72: General Purpose Timer Register 1 Address 12h: General Purpose Timer Register 1 Bit Name 7 gpt15 6 gpt14 5 gpt13 4 gpt12 3 gpt11 2 gpt10 1 gpt9 0 gpt8 Default Function Type: RW Comments General purpose timeout definition MSB bits Defined in steps of 8/fc (590 ns) Range from 590 ns to 38,7 ms Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. General Purpose Timer Register 2 Figure 73: General Purpose Timer Register 2 Address 13h: General Purpose Timer Register 2 Bit Name 7 gpt7 6 gpt6 5 gpt5 4 gpt4 3 gpt3 2 gpt2 1 gpt1 0 gpt0 Default Function Type: RW Comments General purpose timeout definition LSB bits Defined in steps of 8/fc (590 ns) Range from 590 ns to 38,7 ms Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. Page 86 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Mask Main Interrupt Register Figure 74: Mask Main Interrupt Register Address 14h: Mask Main Interrupt Register Bit Name Default 7 M_osc 0 Mask IRQ when oscillator frequency is stable 6 M_wl 0 Mask IRQ due to FIFO water level 5 M_rxs 0 Mask IRQ due to start of receive 4 M_rxe 0 Mask IRQ due to end of receive 3 M_txe 0 Mask IRQ due to end of transmission 2 M_col 0 Mask IRQ due to bit collision 1 0 0 0 Function Type: RW Comments Not used Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. Mask Timer and NFC Interrupt Register Figure 75: Mask Timer and NFC Interrupt Register Address 15h: Mask Timer and NFC Interrupt Register Bit Name Default 7 M_dct 0 Mask IRQ due to termination of direct command 6 M_nre 0 Mask IRQ due to No-Response Timer expire 5 M_gpe 0 Mask IRQ due to general purpose timer expire 4 M_eon 0 Mask IRQ due to detection of external field higher than Target activation level 3 M_eof 0 Mask IRQ due to detection of external field drop below Target activation level ams Datasheet [v1-13] 2015-Jun-18 Function Type: RW Comments Page 87 Document Feedback AS3911B − Application Information Address 15h: Mask Timer and NFC Interrupt Register Bit Name Default Function 2 M_cac 0 Mask IRQ due to detection of collision during RF Collision Avoidance 1 M_cat 0 Mask IRQ after minimum guard time expire 0 M_nfct 0 Mask IRQ when in target mode the initiator bit rate was recognized Type: RW Comments Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. Mask Error and Wake-Up Interrupt Register Figure 76: Mask Error and Wake-Up Interrupt Register Address 16h: Mask Error and Wake-Up Interrupt Register Bit Name Default Function 7 M_crc 0 Mask IRQ due to CRC error 6 M_par 0 Mask IRQ due to parity error 5 M_err2 0 Mask IRQ due to soft framing error 4 M_err1 0 Mask IRQ due to hard framing error 3 M_wt 0 Mask IRQ due to wake-up interrupt 2 M_wam 0 Mask Wake-up interrupt due to Amplitude Measurement 1 M_wph 0 Mask Wake-up interrupt due to Phase Measurement. 0 M_wcap 0 Mask Wake-up interrupt due to Capacitance Measurement Type: RW Comments Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. Page 88 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Main Interrupt Register Figure 77: Main Interrupt Register Address 17h: Main Interrupt Register Bit Name 7 I_osc Default Type: R Function Comments IRQ when oscillator frequency is stable Set after oscillator is started by setting Operation Control Register bit en. Set during receive, informing that FIFO is almost full and has to be read out. Set during transmit, informing that FIFO is almost empty and that additional data has to be sent. 6 I_wl IRQ due to FIFO water level 5 I_rxs IRQ due to start of receive 4 I_rxe IRQ due to end of receive 3 I_txe IRQ due to end of transmission 2 I_col IRQ due to bit collision 1 I_tim IRQ due to timer or NFC event Details are in Timer and NFC Interrupt Register 0 I_err IRQ due to error and wake-up timer Details are in Error and Wake-Up Interrupt Register Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, content of this register is set to 0. 2. After Main Interrupt Register has been read, its content is set to 0, except for bits 1 and 0, which are set to 0 after corresponding interrupt register is read. ams Datasheet [v1-13] 2015-Jun-18 Page 89 Document Feedback AS3911B − Application Information Timer and NFC Interrupt Register Figure 78: Timer and NFC Interrupt Register Address 18h: Timer and NFC Interrupt Register Default Function Type: R Bit Name 7 I_dct IRQ due to termination of direct command 6 I_nre IRQ due to No-Response Timer expire 5 I_gpe IRQ due to general purpose timer expire 4 I_eon IRQ due to detection of external field higher than Target activation level 3 I_eof IRQ due to detection of external field drop below Target activation level 2 I_cac IRQ due to detection of collision during RF Collision Avoidance An external field was detected during RF Collision Avoidance An external field was not detected during RF Collision Avoidance, field was switched on, IRQ is sent after minimum guard time according to NFCIP-1 1 I_cat IRQ after minimum guard time expire 0 I_nfct IRQ when in target mode the initiator bit rate was recognized Comments Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, content of this register is set to 0. 2. After Timer and NFC Interrupt Register has been read, its content is set to 0. Page 90 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Error and Wake-Up Interrupt Register Figure 79: Error and Wake-Up Interrupt Register Address 19h: Error and Wake-Up Interrupt Register Default Function Type: R Bit Name Comments 7 I_crc CRC error 6 I_par Parity error 5 I_err2 Soft framing error Framing error which does not result in corrupted Rx data 4 I_err1 Hard framing error Framing error which results in corrupted Rx data Wake-up interrupt Timeout after execution of Start Wake-Up Timer command In case option with IRQ at every timeout is selected 3 I_wt 2 I_wam Wake-up interrupt due to Amplitude Measurement Result of Amplitude Measurement was Δam larger than reference 1 I_wph Wake-up interrupt due to Phase Measurement. Result of Phase Measurement was Δpm larger than reference 0 I_wcap Wake-up interrupt due to Capacitance Measurement Result of Capacitance Measurement was Δcm larger than reference Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, content of this register is set to 0 2. After Error and Wake-Up Interrupt Register has been read, its content is set to 0 ams Datasheet [v1-13] 2015-Jun-18 Page 91 Document Feedback AS3911B − Application Information FIFO Status Register 1 Figure 80: FIFO Status Register 1 Address 1Ah: FIFO Status Register 1 Bit Name Default Type: R Function Comments 7 6 fifo_b6 5 fifo_b5 4 fifo_b4 3 fifo_b3 2 fifo_b2 1 fifo_b1 0 fifo_b0 Number of bytes (binary coded) in the FIFO which were not read out Valid range is from 0 (000 0000b) to 96 (110 0000b) Note(s) and/or Footnote(s): 1. At power-up and after direct commands Set Default and Clear, content of this register is set to 0. Page 92 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information FIFO Status Register 2 Figure 81: FIFO Status Register 2 Address 1Bh: FIFO Status Register 2 Bit Name Default Type: R Function Comments 7 6 fifo_unf FIFO underflow 5 fifo_ovr FIFO overflow 4 fifo_ncp Last FIFO byte is not complete 3 fifo_lb2 2 fifo_lb1 1 fifo_lb0 0 np_lb Set when more bytes then actual content of FIFO were read Number of bits in last FIFO byte in case it was not complete (fifo_npc=1) In case of incomplete byte the LSB part is valid Parity bit is missing in last byte This is a framing error Note(s) and/or Footnote(s): 1. At power-up and after direct commands Set Default and Clear, content of this register is set to 0. 2. If FIFO is empty, the value of register FIFO Status Register 1 (0x1Ah) is 0x00, register bits fifo_ncp, fifo_lb2, fifo_lb1 and fifo_lb0 in register block 0x1Bh are cleared. Correct procedure for FIFO read is to read both “FIFO Status Register 1 & 2" and then read FIFO. Second register values need to be saved in MCU, if non-complete bytes are in FIFO. ams Datasheet [v1-13] 2015-Jun-18 Page 93 Document Feedback AS3911B − Application Information Collision Display Register Figure 82: Collision Display Register Address 1Ch: Collision Display Register (for ISO14443A and NFCIP-1bit rate fc/128 Rx) Bit Name 7 c_byte3 6 c_byte2 5 c_byte1 4 c_byte0 3 c_bit2 2 c_bit1 1 c_bit0 0 c_pb Default Type: R Function Number of full bytes before the bit collision happened. Number of bits before the collision in the byte where the collision happened Collision in parity bit Comments The Collision Display Register range covers ISO14443A anticollision command. In case collision (or framing error which is interpreted as collision) happens in a longer message, the Collision Display Register is not set. This is an error, reported in case it is the first collision detected Note(s) and/or Footnote(s): 1. At power-up and after direct commands Set Default and Clear, content of this register is set to 0. Page 94 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Number of Transmitted Bytes Register 1 Figure 83: Number of Transmitted Bytes Register 1 Address 1Dh: Number of Transmitted Bytes Register 1 Bit Name Default 7 ntx12 0 6 ntx11 0 5 ntx10 0 4 ntx9 0 3 ntx8 0 2 ntx7 0 1 ntx6 0 0 ntx5 0 Function Number of full bytes to be transmitted in one command, MSB bits Type: RW Comments Maximum supported number of bytes is 8191 Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. Number of Transmitted Bytes Register 2 Figure 84: Number of Transmitted Bytes Register 2 Address 1Eh: Number of Transmitted Bytes 2 Bit Name Default 7 ntx4 0 6 ntx3 0 5 ntx2 0 4 ntx1 0 3 ntx0 0 2 nbtx2 1 nbtx1 0 nbtx0 Function Type: RW Comments Number of full bytes to be transmitted in one command, MSB bits Maximum supported number of bytes is 8191 Number of bits in the split byte 000 means that there is no split byte (all bytes all complete) Applicable for ISO14443A: • Bit oriented anticollision frame in case last byte is split byte • Tx is done without parity bit generation Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. 2. If anctl bit is set while card is in idle state and nbtx is not 000, then i_par will be triggered during WUPA direct command is issued. ams Datasheet [v1-13] 2015-Jun-18 Page 95 Document Feedback AS3911B − Application Information NFCIP Bit Rate Detection Display Register Figure 85: NFCIP Bit Rate Detection Display Register Address 1Fh: NFCIP Bit Rate Detection Display Register Bit Name 7 nfc_rate3 6 nfc_rate2 5 nfc_rate1 4 nfc_rate0 Default Type: R Function Refer to Bit Rate Coding Comments This register stores result of automatic bit rate detection in the NFCIP-1 active communication bit rate detection mode 3 2 Not used 1 0 Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, content of this register is set to 0. A/D Converter Output Register Figure 86: A/D Converter Output Register Address 20h: A/D Converter Output Register Bit Name 7 ad7 6 ad6 5 ad5 4 ad4 3 ad3 2 ad2 1 ad1 0 ad0 Default Function Type: R Comments Displays result of last A/D conversion. Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, content of this register is set to 0. Page 96 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Antenna Calibration Control Register Figure 87: Antenna Calibration Control Register Address 21h: Antenna Calibration Control Register Bit Name Defau lt Function 7 trim_s 0 0: LC trim switches are defined by result of Calibrate Antenna command 1: LC trim switches are defined by bits tre_x written in this register 6 tre_3 0 MSB 5 tre_2 0 4 tre_1 0 3 tre_0 0 LSB Type: RW Comments Defines source of driving switches on TRIMx pins LC trim switches are defined by data written in this register in case trim_s=1. A bit set to 1 switch on transistor on TRIM1_x and TRIM2_x pin. 2 1 0 Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. ams Datasheet [v1-13] 2015-Jun-18 Page 97 Document Feedback AS3911B − Application Information Antenna Calibration Target Register Figure 88: Antenna Calibration Target Register Address 22h: Antenna Calibration Target Register Bit Name Default 7 act7 1 6 act6 0 5 act5 0 4 act4 0 3 act3 0 2 act2 0 1 act1 0 0 act0 0 Function Type: RW Comments Define target phase for Calibrate Antenna direct command Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. Antenna Calibration Display Register Figure 89: Antenna Calibration Display Register Address 23h: Antenna Calibration Display Register Bit Name 7 tri_3 6 tri_2 5 tri_1 4 tri_0 3 tri_err Default Type: R Function MSB LSB 1: Antenna calibration error Comments This register stores result of Calibrate Antenna command. LC trim switches are defined by data written in this register in case trim_s = 0. A bit set to 1 indicates that corresponding transistor on TRIM1_x and TRIM2_x pin is switched on. Set when Calibrate antenna sequence was not able to adjust resonance 2 1 Not used 0 Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, content of this register is set to 0. Page 98 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information AM Modulation Depth Control Register Figure 90: AM Modulation Depth Control Register Address 24h: AM Modulation Depth Control Register Bit Name Default Function 7 am_s 0 0: AM modulated level is defined by bits mod5 to mod0. Level is adjusted automatically by Calibrate Modulation Depth command 1: AM modulated level is defined by bits dram7 to dram0. 6 mod5 0 MSB 5 mod4 0 4 mod3 0 3 mod2 0 2 mod1 0 1 mod0 0 Type: RW Comments See Application Notes for details about AM modulation level definition. LSB 0 Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. ams Datasheet [v1-13] 2015-Jun-18 Page 99 Document Feedback AS3911B − Application Information AM Modulation Depth Display Register Figure 91: AM Modulation Depth Display Register Address 25h: AM Modulation Depth Display Register Bit Name 7 md_7 6 md_6 5 md_5 4 md_4 3 md_3 2 md_2 1 md_1 0 md_0 Default Function Type: R Comments MSB Displays result of Calibrate Modulation Depth command. Antenna drivers are composed of 8 binary weighted segments. Bit md_x set to one indicates that this particular segment will be disabled during AM modulated state. In case of error all 1 value is set. LSB Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, content of this register is set to 0. RFO AM Modulated Level Definition Register Figure 92: RFO AM Modulated Level Definition Register Address 26h: RFO AM Modulated Level Definition Register Bit Name Default 7 dram7 0 6 dram6 0 5 dram5 0 4 dram4 0 3 dram3 0 2 dram2 0 1 dram1 0 0 dram0 0 Function Type: RW Comments MSB Antenna drivers are composed of 8 binary weighted segments. Setting a bit dram to 1 will disable corresponding segment during AM modulated state in case am_s bit is set to 1. LSB Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. Page 100 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information RFO Normal Level Definition Register Figure 93: RFO Normal Level Definition Register Address 27h: RFO Normal Level Definition Register Bit Name Default Function 7 droff7 0 2 Ohm 6 droff6 0 4 Ohm 5 droff5 0 8 Ohm 4 droff4 0 16 Ohm 3 droff3 0 32 Ohm 2 droff2 0 64 Ohm 1 droff1 0 128 Ohm 0 droff0 0 256 Ohm Type: RW Comments Antenna drivers are composed of 8 binary weighted segments. Setting a bit droff to 1 will disable corresponding segment during normal non-modulated operation. The TX drivers are made up of 8 segments. Binary weighted from 2 Ohm to 256Ohm. By setting register 0x27 to 0xc0 you disable the 2 Ohm and 4 Ohm segments. Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. Applying value FFh to the register 27h will put the drivers in tristate. External Field Detector Threshold Register Figure 94: External Field Detector Threshold Register Address 29h: External Field Detector Threshold Register Bit Name Default 7 Function Type: RW Comments Not used 6 trg_l2 0 Peer Detection Threshold MSB 5 trg_l1 1 4 trg_l0 1 Peer Detection Threshold LSB 3 rfe_t3 0 Collision Avoidance Threshold MSB 2 rfe_t2 0 1 rfe_t1 1 0 rfe_t0 1 Peer Detection Threshold. Refer to Peer Detection Threshold as Seen on RFI1 Input. Collision Avoidance Threshold. Refer to Collision Avoidance Threshold as Seen on RFI1 Input. Collision Avoidance Threshold LSB Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. ams Datasheet [v1-13] 2015-Jun-18 Page 101 Document Feedback AS3911B − Application Information Figure 95: Peer Detection Threshold as Seen on RFI1 Input Peer Detection Threshold as Seen on RFI1 Input trg_l2 trg_l1 trg_l0 Target Peer Detection Threshold Voltage [mVpp on RFI1] 0 0 0 75 0 0 1 105 0 1 0 150 0 1 1 205 1 0 0 290 1 0 1 400 1 1 0 560 1 1 1 800 Page 102 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Figure 96: Collision Avoidance Threshold as Seen on RFI1 Input Collision Avoidance Threshold as Seen on RFI1 Input rfe_3 rfe_2 rfe_1 rfe_0 Typical Collision Avoidance Threshold Voltage [mVpp on RFI1] 0 0 0 0 75 0 0 0 1 105 0 0 1 0 150 0 0 1 1 205 0 1 0 0 290 0 1 0 1 400 0 1 1 0 560 0 1 1 1 800 1 0 0 0 25 1 0 0 1 33 1 0 1 0 47 1 0 1 1 64 1 1 0 0 90 1 1 0 1 125 1 1 1 0 175 1 1 1 1 250 ams Datasheet [v1-13] 2015-Jun-18 Page 103 Document Feedback AS3911B − Application Information Regulator Voltage Control Register Figure 97: Regulator Voltage Control Register Address 2Ah: Regulated Voltage Control Register Type: RW Bit Name Default Function Comments 7 reg_s 0 0: Regulated voltages are defined by result of Adjust Regulators command 1: Regulated voltages are defined by rege_x bits written in this register Defines mode of regulator voltage setting. 6 rege_3 0 MSB 5 rege _2 0 4 rege _1 0 3 rege _0 0 LSB External definition of regulated voltage. Refer to Regulated Voltage for definition. In 5 V mode VSP_D and VSP_A regulators are set to 3.4 V 2 mpsv1 0 00: VDD 01: VSP_A 10: VSP_D 11: VSP_RF 1 mpsv0 0 Define source of direct command Measure Power Supply. 0 Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. Page 104 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Regulator and Timer Display Register Figure 98: Regulator and Timer Display Register Address 2Bh: Regulator and Timer Display Register Bit Name 7 reg_3 6 reg_2 5 reg_1 4 reg_0 Default Function Type: R Comments MSB This register displays actual regulated voltage setting. Refer to Regulated Voltage for definition. LSB 3 2 gpt_on 1: General purpose timer is running 1 nrt_on 1: No-response timer is running 0 mrt_on 1: Mask receive timer is running Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, regulated voltage is set to maximum 3.4V. ams Datasheet [v1-13] 2015-Jun-18 Page 105 Document Feedback AS3911B − Application Information Figure 99: Regulated Voltages Regulated Voltage reg_3 rege_3 reg_2 rege_2 reg_1 rege_1 reg_0 rege_0 1 1 1 1 1 1 Typical Regulated Voltage [V] 5 V Mode 3.3 V Mode 1 5.1 3.4 1 0 4.98 3.3 1 0 1 4.86 3.2 1 1 0 0 4.74 3.1 1 0 1 1 4.62 3.0 1 0 1 0 4.50 2.9 1 0 0 1 4.38 2.8 1 0 0 0 4.26 2.7 0 1 1 1 4.14 2.6 0 1 1 0 4.02 2.5 0 1 0 1 3.90 2.4 other combinations Page 106 Document Feedback not used ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information RSSI Display Register Figure 100: RSSI Display Register Address 2Ch: RSSI Display Register Bit Name Default Function 7 rssi_am_3 6 rssi_am_2 5 rssi_am_1 4 rssi_am_0 LSB 3 rssi_pm_3 MSB 2 rssi_pm_2 1 rssi_pm_1 0 rssi_pm_0 MSB LSB Type: R Comments Stores peak value of AM channel RSSI measurement. Automatically cleared at beginning of transponder message and with Clear RSSI command. Stores peak value of PM channel RSSI measurement. Automatically cleared at beginning of transponder message and with Clear RSSI command. Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, content of this register is set to 0. 2. Bit 0x30[7] indicates which RSSI value is use in the logic for internal use. ams Datasheet [v1-13] 2015-Jun-18 Page 107 Document Feedback AS3911B − Application Information Figure 101: RSSI Table RSSI Table rssi_3 rssi_2 rssi_1 rssi_0 Typical Signal on RFI1 [mVrms] 0 0 0 0 ≤20 0 0 0 1 >20 0 0 1 0 >27 0 0 1 1 >37 0 1 0 0 >52 0 1 0 1 >72 0 1 1 0 >99 0 1 1 1 >136 1 0 0 0 >190 1 0 0 1 >262 1 0 1 0 >357 1 0 1 1 >500 1 1 0 0 >686 1 1 0 1 >950 1 1 1 0 1 1 1 1 not used Page 108 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Gain Reduction State Register Figure 102: Gain Reduction State Register Address 2Dh: Gain Reduction State Register Bit Name Default Function 7 gs_am_3 6 gs_am_2 5 gs_am_1 4 gs_am_0 LSB 3 gs_pm_3 MSB 2 gs_pm_2 1 gs_pm_1 0 gs_pm_0 Type: R Comments MSB Actual gain reduction of second stage of AM channel (including register gain reduction, squelch and AGC) Actual gain reduction of second stage of PM channel (including register gain reduction, squelch and AGC) LSB Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, content of this register is set to 0. ams Datasheet [v1-13] 2015-Jun-18 Page 109 Document Feedback AS3911B − Application Information Capacitive Sensor Control Register Figure 103: Capacitive Sensor Control Register Address 2Eh: Capacitive Sensor Control Register Bit Name Default 7 cs_mcal4 0 6 cs_mcal3 0 5 cs_mcal2 0 4 cs_mcal1 0 3 cs_mcal0 0 2 cs_g2 0 1 cs_g1 0 0 cs_g0 0 Function Type: RW Comments Manual calibration value All 0 value enables automatic calibration mode Binary weighted, step 0.1 pF, max 3.1 pF 000: 2.8 V/pF 001: 6.5 V/pF 010: 1.1 V/pF 100: 0.5 V/pF 110: 0.35 V/pF Other: Not used Capacitor sensor gain typical values Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, content of this register is set to 0. Page 110 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Capacitive Sensor Display Register Figure 104: Capacitive Sensor Display Register Address 2Fh: Capacitive Sensor Display Register Bit Name Default Function 7 cs_cal4 6 cs_cal3 5 cs_cal2 4 cs_cal1 3 cs_cal0 2 cs_cal_end 1: Calibration ended 1 cs_cal_err 1: Calibration error Capacitive Sensor calibration value Type: R Comments Binary weighted, step 0.1 pF, max 3.1 pF 0 Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, content of this register is set to 0. Auxiliary Display Register Figure 105: Auxiliary Display Register Address 30h: Auxiliary Display Register Bit Name Default Function 7 a_cha 6 efd_o 5 tx_on 1: Transmission is active 4 osc_ok 1: X-tal oscillation is stable 3 rx_on 1: Receive coder is enabled 2 rx_act 1: Receive coder is receiving a message 1 nfc_t 1: External Field Detector is active in peer detection mode 0 en_ac 1: External Field Detector is active in RF collision avoidance mode 0: AM 1: PM Type: R Comments Currently selected channel External Field Detector output Indication that x-tal oscillator is active and its output is stable Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, content of this register is set to 0. ams Datasheet [v1-13] 2015-Jun-18 Page 111 Document Feedback AS3911B − Application Information Wake-Up Timer Control Register Figure 106: Wake-Up Timer Control Register Address 31h: Wake-Up Timer Control Register Function Type: RW Bit Name Default Comments 7 wur 0 6 wut2 0 5 wut1 0 4 wut0 0 3 wto 0 1: IRQ at every timeout 2 wam 0 1: At timeout perform Amplitude measurement IRQ if difference larger than Δam 1 wph 0 1: At timeout perform Phase measurement IRQ if difference larger than Δpm 0 wcap 0 1: At timeout perform Capacitance measurement IRQ if difference larger than Δcm 0: 100 ms 1: 10 ms Wake-up timer range Refer to Typical Wake-Up Time Wake-up timer timeout value Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. Figure 107: Typical Wake-Up Time Typical Wake-Up Time wut2 wut1 wut0 100 ms Range (wur=0) 10 ms Range (wur=1) 0 0 0 100 ms 10 ms 0 0 1 200 ms 20 ms 0 1 0 300 ms 30 ms 0 1 1 400 ms 40 ms 1 0 0 500 ms 50 ms 1 0 1 600 ms 60 ms 1 1 0 700 ms 70 ms 1 1 1 800 ms 80 ms Page 112 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Amplitude Measurement Configuration Register Figure 108: Amplitude Measurement Configuration Register Address 32h: Amplitude Measurement Configuration Register Bit Name Default 7 am_d3 0 6 am_d2 0 5 am_d1 0 4 am_d0 0 3 am_aam 0 2 am_aew1 0 1 am_aew2 0 0 am_ae 0 Function Type: RW Comments Definition of Δam (difference to reference which triggers interrupt) 0: Exclude the IRQ measurement 1: Include the IRQ measurement Include/exclude the measurement which causes IRQ (having difference > Δam to reference) in auto-averaging 00: 4 01: 8 10: 16 11: 32 Define weight of last measurement result for auto-averaging 1: Use amplitude measurement auto-averaging as reference Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. ams Datasheet [v1-13] 2015-Jun-18 Page 113 Document Feedback AS3911B − Application Information Amplitude Measurement Reference Register Figure 109: Amplitude Measurement Reference Register Address 33h: Amplitude Measurement Reference Register Bit Name Default 7 am_ref7 0 6 am_ref6 0 5 am_ref5 0 4 am_ref4 0 3 am_ref3 0 2 am_ref2 0 1 am_ref1 0 0 am_ref0 0 Function Type: RW Comments Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. Amplitude Measurement Auto-Averaging Display Register Figure 110: Amplitude Measurement Auto-Averaging Display Register Address 34h: Amplitude Measurement Auto-Averaging Display Register Bit Name 7 am_aad7 6 am_aad6 5 am_aad5 4 am_aad4 3 am_aad3 2 am_aad2 1 am_aad1 0 am_aad0 Default Function Type: R Comments Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, content of this register is set to 0. Page 114 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Amplitude Measurement Display Register Figure 111: Amplitude Measurement Display Register Address 35h: Amplitude Measurement Display Register Bit Name 7 am_amd7 6 am_amd6 5 am_amd5 4 am_amd4 3 am_amd3 2 am_amd2 1 am_amd1 0 am_amd0 Default Function Type: R Comments Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, content of this register is set to 0. ams Datasheet [v1-13] 2015-Jun-18 Page 115 Document Feedback AS3911B − Application Information Phase Measurement Configuration Register Figure 112: Phase Measurement Configuration Register Address 36h: Phase Measurement Configuration Register 0 Bit Name Default 7 pm_d3 0 6 pm_d2 0 5 pm_d1 0 4 pm_d0 0 3 pm_aam 0 2 pm_aew1 0 1 pm_aew0 0 pm_ae 0 Function Type: RW Comments Definition of Δpm (difference to reference which triggers interrupt) 0: Exclude the IRQ measurement 1: Include the IRQ measurement Include/exclude the measurement which causes IRQ (having difference > Δpm to reference) in auto-averaging 00: 4 01: 8 10: 16 11: 32 Define weight of last measurement result for auto-averaging 1: Use phase measurement auto-averaging as reference Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. Page 116 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Phase Measurement Reference Register Figure 113: Phase Measurement Reference Register Address 37h: Phase Measurement Reference Register Bit Name Default 7 pm_ref7 0 6 pm_ref6 0 5 pm_ref5 0 4 pm_ref4 0 3 pm_ref3 0 2 pm_ref2 0 1 pm_ref1 0 0 pm_ref0 0 Function Type: RW Comments Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. Phase Measurement Auto-Averaging Display Register Figure 114: Phase Measurement Auto-Averaging Display Register Address 38h: Phase Measurement Auto-Averaging Display Register Bit Name 7 pm_aad7 6 pm_aad6 5 pm_aad5 4 pm_aad4 3 pm_aad3 2 pm_aad2 1 pm_aad1 0 pm_aad0 Default Function Type: R Comments Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, content of this register is set to 0. ams Datasheet [v1-13] 2015-Jun-18 Page 117 Document Feedback AS3911B − Application Information Phase Measurement Display Register Figure 115: Phase Measurement Display Register Address 39h: Phase Measurement Display Register Bit Name 7 pm_amd7 6 pm_amd6 5 pm_amd5 4 pm_amd4 3 pm_amd3 2 pm_amd2 1 pm_amd1 0 pm_amd0 Default Function Type: R Comments Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, content of this register is set to 0. Page 118 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Capacitance Measurement Configuration Register Figure 116: Capacitance Measurement Configuration Register Address 3Ah: Capacitance Measurement Configuration Register Bit Name Default Function 7 cm_d3 0 Definition of Δcm (difference to reference which triggers interrupt) 6 cm_d2 0 5 cm_d1 0 4 cm_d0 0 3 cm_aam 0 2 cm_aew1 0 1 cm_aew0 0 0 cm_ae 0 Type: RW Comments 0: Exclude the IRQ measurement 1: Include the IRQ measurement Include/exclude the measurement which causes IRQ (having difference > Δcm to reference) in auto-averaging 00: 4 01: 8 10: 16 11: 32 Define weight of last measurement result for auto-averaging 1: Use capacitance measurement auto-averaging as reference Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. ams Datasheet [v1-13] 2015-Jun-18 Page 119 Document Feedback AS3911B − Application Information Capacitance Measurement Reference Register Figure 117: Capacitance Measurement Reference Register Address 3Bh: Capacitance Measurement Reference Register Bit Name Default 7 cm_ref7 0 6 cm_ref6 0 5 cm_ref5 0 4 cm_ref4 0 3 cm_ref3 0 2 cm_ref2 0 1 cm_ref1 0 0 cm_ref0 0 Function Type: RW Comments Note(s) and/or Footnote(s): 1. Default setting is set at power-up and after Set Default command. Capacitance Measurement Auto-Averaging Display Register Figure 118: Capacitance Measurement Auto-Averaging Display Register Address 3Ch: Capacitance Measurement Auto-Averaging Display Register Bit Name 7 cm_aad7 6 cm_aad6 5 cm_aad5 4 cm_aad4 3 cm_aad3 2 cm_aad2 1 cm_aad1 0 cm_aad0 Default Function Type: R Comments Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, content of this register is set to 0. Page 120 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Capacitance Measurement Display Register Figure 119: Capacitance Measurement Display Register Address 3Dh: Capacitance Measurement Display Register Bit Name 7 cm_amd7 6 cm_amd6 5 cm_amd5 4 cm_amd4 3 cm_amd3 2 cm_amd2 1 cm_amd1 0 cm_amd0 Default Function Type: R Comments Note(s) and/or Footnote(s): 1. At power-up and after Set Default command, content of this register is set to 0. IC Identity Register Figure 120: IC Identity Register Address 3Fh: IC Identity Register Bit Name 7 ic_type4 6 ic_type3 5 ic_type2 4 ic_type1 3 ic_type0 2 ic_rev2 1 ic_rev1 0 ic_rev0 ams Datasheet [v1-13] 2015-Jun-18 Default Function Type: R Comments Code for AS3911B: 00001 5 bit IC type code 010: silicon r3.1 011: silicon r3.3 100: silicon r4.0 3 bit IC revision code Page 121 Document Feedback AS3911B − Application Information Power-Up Sequence At power-up, the AS3911B enters the Power-down mode. The content of all registers is set to the default state. 1. Firstly, the microcontroller after a power-up must correctly configure the two IO configuration registers. The content of these two registers defines operation options related to hardware (power supply mode, Xtal type, use of MCU_CLK clock, antenna operation mode). 2. Configure the regulators. It is recommended to use direct command Adjust Regulators to improve the system PSRR. 3. If implementing the LC tank tuning, then send the direct command Calibrate Antenna. 4. If using the AM modulation (ISO14443B for example), then set the modulation depth in the AM Modulation Depth Control Registerand send the command Calibrate Modulation Depth. 5. The AS3911B is now ready to operate. Reader Operation To begin with, the operation mode and data rate have to be configured by writing the Mode Definition Register and Bit Rate Definition Register. Additionally, the receiver and transmitter operation options related to operation mode have to be defined. This is done automatically by sending the direct command Analog Preset. If more options are required apart from those defined by Analog Preset, then such options must be additionally set by writing the appropriate registers. Next, the Ready mode has to be entered by setting the bit en of the Operation Control Register. In this mode the oscillator is started and the regulators are enabled. When the oscillator operation is stable, an interrupt is sent. Before sending any command to a transponder, the transmitter and receiver have to be enabled by setting the bits rx_en and tx_en. RFID protocols usually require that the reader field is turned on for a while before sending the first command (5 ms for ISO14443). General purpose timer can be used to count this time. Page 122 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information In case REQA or WUPA has to be sent this is simply done by sending appropriate direct command otherwise the following sequence has to be followed: 1. Send the direct command Clear 2. Define the number of transmitted bytes in the Number of Transmitted Bytes Register 1 and Number of Transmitted Bytes Register 2 3. Write the bytes to be transmitted in the FIFO 4. Send the direct command Transmit With CRC or Transmit Without CRC (whichever is appropriate) 5. When all the data is transmitted an interrupt is sent to inform the microcontroller that the transmission is finished (IRQ due to end of transmission) After the transmission is executed, the AS3911B receiver automatically starts to observe the RFI inputs to detect a transponder response. The RSSI and AGC (in case it is enabled) are started. The framing block processes the sub-carrier signal from receiver and fills the FIFO with data. When the reception is finished and all the data is in the FIFO an interrupt is sent to the microcontroller (IRQ due to end of receive), additionally the FIFO Status Register 1 and FIFO Status Register 2 display the number of bytes in the FIFO so the microcontroller can proceeded with downloading the data. In case there was an error or bit collision detected during reception, an interrupt with appropriate flag is sent. Microcontroller has to take appropriate action. Transmit and Receive in Case Data Packet is Longer than FIFO: In case a data packet is longer than FIFO the sequence explained above is modified. Before transmit the FIFO is filled. During transmit an interrupt is sent when remaining number of bytes is lower than the water level (IRQ due to FIFO water level). The microcontroller in turn adds more data in the FIFO. When all the data is transmitted an interrupt is sent to inform the microcontroller that transmission is finished. During reception situation is similar. In case the FIFO is loaded with more data than the receive water level, an interrupt is sent and the microcontroller in turn reads the data from the FIFO. When reception is finished an interrupt is sent to the microcontroller (IRQ due to end of receive), additionally the FIFO Status Register 1 and FIFO Status Register 2 display the number of bytes in the FIFO which are still to be read out. Anticollision – ISO 14443A Note(s): For this section, it is assumed that there are more than one ISO/IEC 14443A PICC in the reader’s RF field and all are compatible to ISO/IEC 14443 up to level 4. This section highlights on a procedure of performing anticollision with AS3911B for ISO14443A tags. After an ISO14443 type A tag enters in the reader field, the reader has ams Datasheet [v1-13] 2015-Jun-18 Page 123 Document Feedback AS3911B − Application Information to perform a selection process which brings it into the PROTOCOL state in which the actual application implemented in the tag can be executed. This selection process is described in the ISO/IEC 14443-3. The Figure 121 depicts the states which a tag and a reader have to pass through to enter the protocol state. Figure 121: ISO14443A States for PCD and PICC PICC States PCD States Power off (No Field) Standby Idle (Field ON) Poll for PICC with REQA REQA, WUPA Ready Receive ATQA Select Active Perform bit frame Anticollision loop Increase Cascade level RATS UID not complete ISO 14443-4 Check for SAK UID complete & PICC compliant to ISO 14443-4 ISO 14443-4 The selection procedure starts when a PICC enters the reader field and the PCD sends a REQA (or WUPA) command followed by an Anticollision procedure (incl. SELECT, RATS and PPS). Page 124 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Setting up AS3911B for ISO 14443A Anticollision To setup the AS3911B for the ISO14443A anticollision following steps are to be followed: 1. The Initiator operation mode of AS3911B must be setup for ISO 14443A in the Mode Definition Register (default is already for ISO14443A). 2. The Tx and Rx bit rates must be set up to default 106kbps in the Bit Rate Definition Register. 3. Set the antcl bit in the ISO14443A and NFC 106kb/s Settings Register. This needs to be set before sending the REQA (or WUPA). As a result of setting this bit, the AS3911B will not trigger a framing error if in case the collision occurs in the ATQA or during anticollision procedure. Note(s): This bit must be set to one for REQA, WUPA and ANTOCOLLISION commands, for other commands it has to be zero. 4. Review and set the value for Mask Receive Timer Register less than the Frame delay time as required by the ISO14443A. And set the No-Response Timer Register 1&No-Response Timer Register 2 according to the requirements. This is typically larger than the FDT. Note(s): AS3911B offers the resolution of n/2 (64/fc - half steps) compared to n (128/fc) as mentioned in 14443A so that the receiver can be unmasked n/2 step before the actual transmission from the PIC. 5. According to ISO 14443A the FDT must be 1236/fc if last transmitter bit if 1 or 1172/fc if last transmitter bit is 0. As a simple rule one can follow the following. Figure 122: Selection of MRT & NRT for a Given FDT FDT PCD to PICC PICC to PCD t MRT < FDT – 64/fc NRE > FDT + 64/fc ams Datasheet [v1-13] 2015-Jun-18 Page 125 Document Feedback AS3911B − Application Information 6. The receiver and transmitter operation options related to operation mode have to be defined. This is done automatically by sending the direct command Analog Preset. If different options are required apart from those defined by Analog Preset, then such options must be additionally set by writing the appropriate registers. 7. Set rx_en and tx_en in the Operation Control Register. RFID protocols usually require that the reader field is turned on for a while before sending the first command (5 ms for ISO14443). General purpose timer can be used to count this time. 8. The reply form PICC for the REQA, WUPA and replies within ANTICOLLISION sequence before till before SAK do not contain CRC. In this case the no_CRC_rx bit in the Auxiliary Definition Register must be set to 1 (receive without CRC) before sending these commands. REQA and WUPA Sending of these two commands is simple since they are implemented as the AS3911B direct commands (Transmit REQA and Transmit WUPA). The end of transmission of these commands is signaled to microcontroller by an interrupt - IRQ due to end of transmission). After the transmission is executed, the AS3911B receiver automatically starts to observe the RFI inputs to detect a transponder after the expiration of the Mask Receive Timer. As a response to REQA (or WUPA) all the PICC in the field respond simultaneously with an ATQA. A collision can occur in this state if there are PICC with different UID size or has the Bit frame anticollision bits set differently. Hence it is important to set the antcl bit to 1. If there is any IRQ (except I_nre) that AS3911B signals, the microcontroller must consider as a valid presence of tag and must proceed with the ANTICOLLISION procedure. If more than one PICC are expected in the field, following algorithm must be used to select multiple tags: 1. Send REQA, if there was any answer continue 2. Perform anticollision, and singulate one PICC 3. Select the found Tag and send HLTA to move it to HALT state 4. Go to 1 and repeat this procedure till all the PICC are in HALT state and all the UIDs have been extracted. Page 126 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information ANTICOLLISION Procedure After receiving the ATQA from the tags in the field, the next step is to execute the anticollision procedure to singulate the tags. the procedure mainly uses the ANTICOLLISION and SELECT commands which consist of: • Select code SEL (1byte) • Number of valid bits NVB (1 byte) • 0 to 40 data bits of UID CLn according to the value of NVB The anticollision command uses standard frame which do not use CRC. In this case the transmit needs to be done with direct command Transmit Without CRC and for the receive, the no_CRC_rx bit in the Auxiliary Definition Register must be set to 1. The final SELECT command and its response SAK contains a CRC, so the transmit needs to be done with command Transmit With CRC and before sending this command the configuration bit no_CRC_rx bit in the Auxiliary Definition Register must be set back to 0. If there are more than one PICC in the field, the collision will occur when the tags reply to the SEL command during anticollision when the PICC reply back with their UID. This collision can occur after a complete byte (called as FULL BYTE scenario) or it can occur within a byte (called as SPLIT BYTE scenario). The antcl bit in ISO14443A and NFC 106kb/s Settings Register must be set during this procedure too. As a result, AS3911B will not trigger a Framing Error. This bit is also responsible for correct timing of anticollision and correct parity extraction. Note(s): It must only be set before sending an anticollision frame, REQA or WUPA. This bit must not be used in any other commands. The Figure 123 depicts the flowchart on how to implement the anticollision with AS3911B. ams Datasheet [v1-13] 2015-Jun-18 Page 127 Document Feedback AS3911B − Application Information Figure 123: Flowchart for ISO14443A Anticollision with AS3911B Cascade level n (n =1) SELn=0x93 for n=1 for 4 bytes UID SELn=0x95 for n=2 for 7 bytes UID SELn=0x97 for n=3 for 10 bytes UID 1) Fill fifo with SELn + NVB (0x20) 2)Set Register: Number of transmitted bytes register 1 = 0x00 Number of transmitted bytes register 2 = 0x10 1) Send Command: Transmit without CRC 2) Following interrupts: I_dct I_txe I_col (if collision occurs) I_rxs I_rxe FIFO is filled in with PICC response No Read out FIFO for the valid data from the selected PICC I_col ? Yes PICC sends complete UID Set: no_CRC_rx = 1, antcl = 1 Set: no_CRC_rx = 0, antcl = 0 1) Read Collision Display Register to identify how much is the valid data before the collison occured, 2) Read FIFO for the response from PICC NOTE: Since SPI is byte oriented, in case of SPLIT BYTE scenario, the invalid MSB bits must be ignored when reading out the FIFO for the received data. Similarly, 0s must be concatenated As MSB bits to complete a byte for the Transmit (which will then be ignored based on register 0x1E) Send SELECT: Fill FIFO with SELn + NVB(0x70) + UID CLn 1) Fill FIFO with part 1 of bit collision anticollision: SELn + NVB (available from valid tag response) + received valid data +1 or 0 for the bit where the collision occured 1) Send Command: Transmit with CRC 2) Following interrupts: I_dct I_txe I_rxe FIFO is filled with SAK No Enter Cascade Level n+1 Page 128 Document Feedback Yes UID complete? FIFO is filled in with PICC response 2) Set Register: Mention the number of received full bytes and split bits + 1 bit in: Number of transmitted bytes register 1 & Number of full bytes Number of transmitted bytes register 2 End Anticollision with RATS ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information FeliCa Reader Mode The general recommendation from previous chapter is valid also for FeliCa reader mode. Bit rates 212 and 424 kb/s are supported. Bit rates are the same in both (reader to tag and tag to reader) directions. Modulation reader to tag is AM. In FeliCa mode the FeliCa frame format is supported. Figure 124: FeliCa Frame Format Preamble SYNC Length Payload CRC Preamble: 48 data bits all logical 0 Sync: 2 bytes (B2h, 4Dh) Length: Length byte (value= payload length + 1), the length range is from 2 to 255 Payload: Payload CRC: 2 bytes FeliCa Transmission In order to transmit FeliCa frame only the Payload data is put in the FIFO. The number of Payload bytes is defined in the Number of Transmitted Bytes Register 1 and Number of Transmitted Bytes Register 2. Preamble length is defined by bits f_p1 and f_p0 in the ISO14443B and FeliCa Settings Register, default value is 48 bits, but also other options are possible. Transmission is triggered by sending direct command Transmit With CRC. First preamble is sent, followed by SYNC and Length bytes. Then Payload stored in FIFO is sent, transmission is terminated by two CRC bytes which are calculated by the AS3911B. Length byte is calculated from ‘number of transmitted bytes’. The following equation is used: length = payload length + 1 = number of transmitted bytes +1 FeliCa Reception After transmission is done the AS3911B logic starts to parse the receiver output to detect the Preamble of FeliCa tag reply. Once the Preamble followed by the two SYNC bytes is detected the Length byte and Payload data are put in the FIFO. CRC bytes are internally checked. NFCIP-1 Operation The AS3911B supports all NFCIP-1 initiator modes and active communication target modes. All NFCIP-1 bit rates (106, 212 and 424 kbit/s) are supported. ams Datasheet [v1-13] 2015-Jun-18 Page 129 Document Feedback AS3911B − Application Information NFCIP-1 Passive Communication Initiator NFCIP-1 passive communication is equivalent to reader (PCD) to tag (PICC) communication where initiator acts as a reader and target acts as tag. The only difference is that in case of the NFCIP-1 passive communication the initiator performs Initial RF Collision Avoidance procedure at the beginning of communication. In order to act as NFCIP-1 passive communication initiator the AS3911B has to be configured according to table below: Figure 125: Operation Mode and Bit Rate Setting for NFCIP-1 Passive Communication NFCIP-1 Bit Rate [kb/s] Operation Mode Setting Bit Rate for Tx [kb/s] Bit Rate for Rx [kb/s] 106 ISO14443A fc/128 (~106) fc/128 (~106) 212 FeliCa fc/64 (~212) x 424 FeliCa fc/32 (~424) x Comment In FeliCa mode data rate is the same in both directions Initial set-up of the Operation Control Register before the start of communication is the same as in case of reader to tag communication, with the exception that the transmitter is not enabled by setting the tx_en bit. The direct command NFC Initial Field ON is sent instead. This command first performs the Initial RF Collision avoidance with Collision Avoidance Threshold defined in the External Field Detector Threshold Register. The timing of collision avoidance is according to NFCIP-1 standard (for timing details see Figure 41). In case collision is not detected the tx_en bit is automatically set to switch the transmitter on. After minimum guard time T IRFG the I_cat IRQ is sent to inform controller that the first initiator command can be send. From this point on communication is the same as in case of ISO14443A (for 106 kb/s) or FeliCa (for 242 and 424 kb/s) reader communication. In case a presence of external field is detected an I_cac IRQ is sent. In such case a transmission should not be performed, command NFC Initial Field ON has to be repeated as long as collision is not detected any more. Initial collision avoidance is not limited to modes supported by NFCIP-1. The initial collision avoidance according to procedure described above can be performed before any reader mode is started to avoid collision with an HF reader or an NFC device operating in proximity. Support of NFCIP-1Transport Frame Format Figure 126 depicts the Transport Frame according to NFCIP-1 standard. Page 130 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Figure 126: Transport Frame Format According to NFCIP-1 Transport Data Field Frame Format for 106 kbps SB LEN CMD0 CMD1 Byte 0 Byte 1 Byte 2 … … Byte n E1 … … Byte n E2 Transport Data Field Frame Format for 212 kbps and 424 kbps PA SB LEN CMD0 CMD1 Byte 0 Byte 1 Byte 2 Transport Frame for bit rate 212 and 424 kb/s has the same format as communication frame used during Initialization and SDD. This format is also used in FeliCa protocol (see also FeliCa Reader Mode). In case of 106 kb/s the SB (Start byte at F0 h) and LEN (length byte) are only used in Transport Frame. Support of Transport Frame for 106 kb/s NFCIP-1 communication is enabled by setting bit nfc_f0 in the ISO14443A and NFC 106kb/s Settings Register. Once this bit is set and ISO 14443A mode with bit rate 106 kb/s is configured, the behavior of the AS3911B framing is as follows: Transmission In order to transmit a Transport Frame only the Transport Data has to be put in FIFO. The number of Transport Data bytes is defined in the Number of Transmitted Bytes Register 1 and Number of Transmitted Bytes Register 2. Transmission is triggered by sending direct command Transmit With CRC. First Start byte with value F0 h followed by Length byte are sent. Then Transport Data stored in FIFO is sent, transmission is terminated by two CRC bytes (E1 in Figure 126) which are calculated by the AS3911B. Length byte is calculated from ‘number of transmitted bytes’. The following equation is used: length = Transport Data length + 1 = number of transmitted bytes +1 Reception After transmission is done the AS3911B logic starts to parse the receiver output to detect the start of tag reply. Once the start of communication sequence is detected the first byte (Start Byte with value F0 h) is checked the Length byte and Transport Data bytes are put in the FIFO. CRC bytes are internally checked. In case the Start byte is not equal to F0 h the following data bytes are still put in FIFO, additionally a soft framing error IRQ is set to indicate the Start Byte error. ams Datasheet [v1-13] 2015-Jun-18 Page 131 Document Feedback AS3911B − Application Information NFCIP-1 Active Communication Initiator During NFCIP-1 active communication both, initiator and target switch on its field when transmitting and switch off its field when receiving. In order to operate as NFCIP-1 active communication initiator the AS3911B has to be configured according to table below (bit targ in the Mode Definition Register has to be 0): Figure 127: Operation Mode and Bit Rate Setting for NFCIP-1 Active Communication Initiator NFCIP-1 Bit Rate [kb/s] Initiator Operation Mode Setting Bit Rate for Tx [kb/s] Bit Rate for Rx [kb/s] 106 NFCIP-1 active communication fc/128 (~106) x 212 NFCIP-1 active communication fc/64 (~212) x 424 NFCIP-1 active communication fc/32 (~424) x Comment For all NFCIP-1 communication, data rate is the same in both directions. After selecting the NFCIP-1 active communication mode the Receiver and Transmitter have to be configured properly. This configuration can be done automatically by sending direct command Analog Preset (see Analog Preset). During NFCIP-1 active communication the RF Collision avoidance and switching on the field is performed using ‘NFC Field ON’ commands (see NFC Field ON Commands), while the sending of message is performed using Transmit commands as in the case of reader communication. Alternatively the Response RF Collision Avoidance sequence is started automatically when the switching off of target field is detected in case the bit nfc_ar in the Mode Definition Register is set. When NFCIP-1 mode is activated the External Field Detector is automatically enabled by setting bit en_fd in the Auxiliary Display Register. The Peer Detection Threshold is used to detect target field. During execution of ‘NFC Field ON’ commands, the Collision Avoidance Threshold is used. Initial set-up of the Operation Control Register before the start of communication is the same as in case of reader to tag communication with the exception that the transmitter is not enabled by setting the tx_en bit. The tx_en bit and therefore switching on of the transmitter is controlled by NFC Field ON commands. Switching off the field is performed automatically after a message has been sent. The General Purpose and No-Response Timer Control Register is used to define the time during which the field stays switched on after a message has been transmitted. Page 132 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information In order to receive the NFCIP-1 active reply only the AM demodulation channel is used. Due to this the Receiver AM channel has to be enabled. The preset done by Analog Preset command enables only the AM demodulation channel, while PM channel is disabled to save current. In NFCIP-1 active communication the NFCIP-1Transport Frame format (see Figure 126) is always used. Due to this the ISO14443A and NFC 106kb/s Settings Register bit nfc_f0 is set by Analog Preset command (see Support of NFCIP-1Transport Frame Format). NFCIP-1 active communication sequence when bit nfc_ar in the Mode Definition Register is set (automatic Response RF Collision Avoidance sequence). During this sequence bits nfc_n1 and nfc_n0 of the Auxiliary Definition Register have to be 0 to produce Response Collision Avoidance sequence with n=0: 1. First the direct command NFC Initial Field ON is sent. In case no collision was detected during RF collision avoidance the field is switched on and an IRQ with I_cat flag set is sent to controller after T IRFG . 2. The message, which was prepared as in case of reader to tag communication, is transmitted using Transmit command. 3. After the message is sent the field is switched off. The time between the end of the message and switching off the field is defined by the General Purpose Timer. (The General Purpose Timer IRQ may be masked since controller does not need this information). 4. After switching off its field the AS3911B starts the No-Response Timer and observes the External Field Detector output to detect the switching on of the target field. In case the target field is not detected before No-Response Timer timeout, an IRQ due No-Response Timer expire is sent. 5. When Target field is detected an IRQ with I_eon flag set is sent to controller and Mask-receive Timer is started. After the Mask Receive Timer expires the receiver output starts to be observed to detect start of the target response. The reception process goes on as in case of reader to tag communication. 6. When the External Field Detector detects that the target has switched off its field, it sends an IRQ with I_eof flag set to the controller, and in case bit nfc_ar is set automatically activates the sequence of direct command NFC Response Field ON. In case no collision is detected during RF collision avoidance the field is switched on and an IRQ with I_cat flag set is sent to controller after T ARFG. ams Datasheet [v1-13] 2015-Jun-18 Page 133 Document Feedback AS3911B − Application Information 7. Sequence loops through point 2. In case the last initiator command is sent in next sequence (DLS_REQ in case of NFCIP-1 protocol) the bit nfc_ar in the Mode Definition Register has to be put to 0 to avoid switching on the initiator field after the target has switched of its field. NFCIP-1 Active Communication Target The AS3911B target mode is activated by setting bit targ in the Mode Definition Register to 1. When target mode is activated the External Field Detector is automatically enabled by setting bit en_fd in the Auxiliary Definition Register. When bit targ is set and all bits of the Operation Control Register are set to 0, the AS3911B is in low power Initial NFC Target Mode. In this mode the External Field Detector with Peer Detection Threshold is enabled. There are two different NFC target modes implemented (defined by mode bits of the Mode Definition Register): the bit rate detection mode and normal mode. In the bit rate detection mode the framing logic performs automatic detection of the initiator data rate and writes it in the NFCIP Bit Rate Detection Display Register. In the normal mode it is supposed that the data rate defined in the Bit Rate Definition Register is used. After selecting the NFCIP-1 active target mode the Receiver and Transmitter have to be configured properly. Configuration is the same as in case of NFCIP-1 active initiator mode. This configuration can be done automatically by sending direct command Analog Preset (see Analog Preset). NFCIP-1 active communication sequence when bit nfc_ar in the Mode Definition Register is set (automatic Response RF Collision Avoidance sequence). During this sequence bits nfc_n1 and nfc_n0 of the Auxiliary Definition Register have to be 0 to produce Response Collision Avoidance with n=0. The following sequence assumes that the AS3911B is in the low power Initial NFC Target Mode with the bit rate detection mode selected. Bit nfc_ar in the Mode Definition Register is set (automatic Response RF Collision Avoidance sequence). When the initiator field is detected the following sequence is executed: 1. An IRQ with I_eon flag set is sent to the controller. 2. The controller turns on the oscillator, regulator and receiver. Mask-receive Timer is started by sending direct command Start Mask-Receive Timer. After the Mask Receive Timer expires the receiver output starts to be observed to detect start of the initiator message. 3. Once the start of initiator message is detected, an IRQ due to start of receive is sent, the framing logic switches on a module which automatically recognizes the bit rate of signal sent by the initiator. Once the bit rate is recognized an IRQ with I_nfct flag set is sent and the bit rate is automatically loaded in the NFCIP Bit Rate Detection Display Register. Detection of bit rate is also a condition that automatic Response RF Collision Page 134 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Avoidance sequence is enabled). The received message is decoded and put into the FIFO, IRQ is sent as after any received message. 4. The controller sends direct command Go to Normal NFC Mode, to copy the content of the NFCIP Bit Rate Detection Display Register to the Bit Rate Definition Register and to change the NFCIP-1 target mode to normal (the command Go To Normal Mode and reading of received data can be chained). Since the Tx modulation type depends on bit rate, the Tx modulation type also has to be correctly set at this point. 5. When the External Field Detector detects that the target has switched off its field, it sends an IRQ with I_eof flag set to the controller, and in case bit nfc_ar is set automatically activates the sequence of direct command NFC Response Field ON. Bits nfc_n1 and nfc_n0 of the Auxiliary Definition Register are used to define number n of Response RF Collision Avoidance sequence. In case no collision is detected during RF collision avoidance the field is switched on and an IRQ with I_cat flag set is sent to controller after T ARFG. 6. The reply, which was prepared as in case of reader to tag communication is transmitted using Transmit command. 7. After the message is sent the field is switched off. The time between the end of the message and switching off the field is defined in the General Purpose Timer. (The General Purpose Timer IRQ may be masked since controller does not need this information). From this point on the communication with initiator loops through the following sequence (during this sequence bits nfc_n1 and nfc_n0 of the Auxiliary Definition Register have to be 0 to produce Response RF Collision Avoidance with n=0): 1. After switching off its field the AS3911B starts the No-Response Timer and observes the External Field Detector output to detect the switching on of the initiator field. In case the initiator field is not detected before No-Response Timer timeout, an IRQ due No-Response Timer expire is sent. 2. When initiator field is detected an IRQ with I_eon flag set is sent to controller and Mask-Receive Timer is started. After the Mask Receive Timer expires the receiver output starts to be observed to detect start of the initiator response. The reception process goes on as in case of reader to tag communication. 3. When the External Field Detector detects that the target has switched off its field, it sends an IRQ with I_eof flag set to the controller, and in case bit nfc_ar is set automatically activates the sequence of direct command NFC Response Field ON. In case no collision is detected during RF collision avoidance the field is switched on and an IRQ with I_cat flag set is sent to controller after T ARFG. ams Datasheet [v1-13] 2015-Jun-18 Page 135 Document Feedback AS3911B − Application Information 4. The reply which was prepared as in case of reader to tag communication is transmitted using Transmit command 5. After the message is sent the field is switched off. The time between the end of the message and switching off the field is defined in General Purpose Timer. In case a new command from initiator is expected the General Purpose Timer IRQ may be masked since controller does not need this information. 6. In case a new command from Initiator is expected the sequence loops through point 1. In case the target reply was the last in a sequence (DLS_RES in case of NFCIP-1 protocol) a new command from initiator is not expected. At the moment the field is switched off, a General Purpose Timer IRQ is received and the AS3911B is put back in the low power NFC Target Mode by deactivating the Operation Control Register. NFC mode is changed back to rate detection mode by writing the Mode Definition Register. AM Modulation Depth: Definition and Calibration The AS3911B Transmitter supports OOK and AM modulation. The choice between OOK and AM modulation is done by writing Auxiliary Definition Register bit tr_am. AM modulation is preset by direct command Analog Preset in case the following protocols are configured: • ISO14443B • FeliCa • NFCIP-1 212 and 424 kb/s The AM modulation depth can be automatically adjusted by setting the AM Modulation Depth Control Register and sending the direct command Calibrate Modulation Depth. There is also an alternative possibility where the command Calibrate Modulation Depth is not used and the modulated level is defined by writing the Antenna driver RFO AM Modulated Level Definition Register. Page 136 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information AM Modulation Depth Definition Using the ‘Calibrate Modulation Depth’ Direct Command Before sending the direct command Calibrate Modulation Depth the AM Modulation Depth Control Register has to be configured in the following way: • The bit 7 (am_s) has to be set to 0 to choose definition by the command Calibrate Modulation Depth • Bits 6 to 1 (mod5 to mod0) define target AM modulation depth Definition of Modulation Depth Using Bits mod5 to mod0: The RFID standard documents usually define the AM modulation level in form of the modulation index. The modulation index is defined by formula (a-b)/(a+b) where a is amplitude of the non-modulated carrier and b is the amplitude of the modulated carrier. The modulation index specification is different for different standards. The ISO14443B modulation index is typically 10% with allowed range from 8% to 14%, range from 10 to 30% is defined in the ISO15693 and 8% to 30% in the FeliCa™ and NFCIP-1 212 kb/s and 424 kb/s. The bits mod5 to mod0 are used to calculate the amplitude of the modulated level. The non-modulated level which was before measured by the A/D converter and stored in an 8 bit register is divided by a binary number in range from 1 to 1.98. The bits mod5 to mod0 define binary decimals of this number. Example: In case of the modulation index 10% the modulated level amplitude is 1.2222 times lower than the non-modulated level. 1.2222 converted to binary and truncated to 6 decimals is 1.001110. So in order to define the modulation index 10% the bits mod5 to mod0 have to be set to 001110. The table below depicts setting of the mod bits for some often used modulation indexes. Figure 128: Setting of the mod Bits for Some Often Used Modulation Indexes Modulation Index [%] a/b [dec] a/b [bin] mod5………mod0 8 1.1739 1.001011 001011 10 1.2222 1.001110 001110 14 1.3256 1.010100 010100 20 1.5000 1.100000 100000 30 1.8571 1.110111 110111 33 1.9843 1.111111 111111 ams Datasheet [v1-13] 2015-Jun-18 Page 137 Document Feedback AS3911B − Application Information Execution of Direct Command ‘Calibrate Modulation Depth’: The modulation level is adjusted by increasing the RFO1 and RFO2 driver output resistance. The RFO drivers are composed of 8 binary weighted segments. Usually all these segments are turned on to define the normal, non-modulated level, there is also a possibility to increase the output resistance of the non-modulated state by writing the RFO Normal Level Definition Register. Before sending the direct command Calibrate Modulation Depth the oscillator and regulators have to be turned on. When the direct command Calibrate Modulation Depth is sent the following procedure is executed: • The Transmitter is turned on, non-modulated level is established. • The amplitude of the non-modulated carrier level established on the inputs RFI1 and RFI2 is measured by the A/D converter and stored in the A/D Converter Output Register. • Based on the measurement of the non-modulated level and the target modulated level defined by the bits mod5 to mod0 the target modulated level is calculated. • The output driver control is taken over by the Calibrate Register. Content of the Calibrate Register is modified using successive approximation algorithm as long as long as the measured level is equal or as close as possible to target modulated level calculated in previous step. • Final state of the Calibrate Register is copied in the AM Modulation Depth Display Register. Content of this register is used to define the AM modulated level. Note(s): After this calibration procedure is finished, the content of the RFO Normal Level Definition Register should not be changed. Modification of this register content will change the non-modulated amplitude and therefore the ratio between the modulated and non-modulated level will be changed. Please also note that in case the calibration of antenna resonant frequency in used, command Calibrate Antenna has to be run before AM modulation depth adjustment. AM Modulation Depth Definition using the ‘RFO AM Modulated Level Definition’ Register When the bit 7 (am_s) of the AM Modulation Depth Control Register is set to 1 the AM modulated level is controlled by writing the RFO AM Modulated Level Definition Register. In case setting of the modulated level is already known it is not necessary to run the calibration procedure, the modulated level can simply be defined by writing this register. It is also possible to implement calibration procedure in external controller using the RFO Normal Level Definition Register and the direct command Measure Amplitude. This procedure has to be used in case the target modulation depth is deeper than 33%. Page 138 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information The procedure is the following: • Write the non-modulated level in the RFO Normal Level Definition Register (usually it is all 0 to have the lower possible output resistance). • Switch on the transmitter. • Send the direct command Measure Amplitude. Read result from the A/D Converter Output Register. • Calculate the target modulated level from the target modulation index and result of the previous point. • In the following iterations content of the RFO Normal Level Definition Register is modified, the command Measure Amplitude executed and result compared to the target modulated level as long as the result is not equal or as close as possible to the target modulated level. • At the end the content of the RFO Normal Level Definition Register which results in the target modulated level is written in the RFO AM Modulated Level Definition Register while the RFO Normal Level Definition Register is restored with the non-modulated definition value. Antenna Tuning The AS3911B comprises the building blocks which make possible checking and adjustment of the antenna LC tank resonance frequency. The AS3911B Phase and Amplitude Detector block is used for resonance frequency checking and adjustment. In order to implement the antenna LC tank calibration tuning capacitors have to be connected between the two coil terminals to the pins TRIM1_3 to TRIM1_0 and TRIM2_3 to TRIM2_0. In case single driver is used only the pins TRIM1_3 to TRIM1_0 are used, pins TRIM2_3 to TRIM2_0 are left open. Figure 129 depicts connection of the trim capacitors for both, single and differential driving for the simple case where the antenna LC tank is directly connected to RFO pins. The TRIM pins contain the HVNMOS switching transistors to V SS. The on resistance of TRIM1_0 and TRIM2_0 switch transistors, which are meant to be connected to LSB tuning capacitor is 50 Ω typ. at 3 V VSP_D, the on resistance of other pins is binary weighted (the on resistance of TRIM1_3 and TRIM2_3 is 6.25 Ω typ.) The breakdown voltage of the HVNMOS switch transistors is 25V, which limits the maximum peak to peak voltage on LC tank in case tuning is used. During tuning procedure the resonance frequency is adjusted by connecting some of the tuning capacitors to V SS and leaving others floating. The Switches of the same binary weight are driven from the same source and are both on or off (the switches TRIM1_2 and TRIM2_2 are for example both either on or off ). ams Datasheet [v1-13] 2015-Jun-18 Page 139 Document Feedback AS3911B − Application Information Antenna tuning can be automatically performed by sending direct command Calibrate Antenna or by an algorithm implemented in external controller by performing phase and amplitude measurements and controlling the TRIM switches using Antenna Calibration Control Register. Antenna Tuning Using Direct Command ‘Calibrate Antenna’ In order to perform the antenna LC tank using direct command Calibrate Antenna binary weighted tuning capacitors have to be connected between the two coil terminals to the pins TRIM1_3 to TRIM1_0 and TRIM2_3 to TRIM2_0. During automatic procedure, started by sending the direct command Calibrate Antenna, the AS3911B finds position of TRIM switches at which the phase difference between the RFO output signal and RFI input signal is as close as possible to target phase defined in the Antenna Calibration Target Register. In case the antenna LC tank is directly connected to RFO pins (as in case of Figure 129) there is 90° phase shift between signal on the RFO outputs and the voltage on the RFI inputs when antenna LC tank is in resonance. In case additional EMC filter is inserted between RFO outputs and antenna LC tank the phase shift in case of resonance depends on additional phase shift generated by EMC filter. During execution of the direct command Calibrate Antenna the AS3911B runs several phase measurements and changes configuration of TRIM pins in order to find the best possible setting. Due to this the format of the Antenna Calibration Target Register is the same as the format of direct command Measure Phase result. The TRIM pin configuration which is result of the direct command Calibrate Antenna can be observed by reading the Antenna Calibration Display Register. This register also contains an error flag which is set in case the tuning to target phase was not possible. After the execution of direct command Calibrate Antenna the actual phase can be checked by sending direct command Measure Phase. Page 140 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Figure 129: Connection of Tuning Capacitors to the Antenna LC Tank in Case of Single (left) and Differential Driving (right) Antenna Tuning Using ‘Antenna Calibration Control’ Register There is also a possibility to control the position of the TRIM switches by writing the Antenna Calibration Control Register. When the bit trim_s of this register is set to 1 position of the trim switches is controlled by bits tre_3 to tre_0. Using this register and performing phase and amplitude measurements (using direct commands Measure Phase and Measure Amplitude) different tuning algorithms can be implemented in the external controller. Stream Mode and Transparent Mode Standard and custom 13.56 MHz RFID reader protocols, which are not supported by the AS3911B framing, can be realized using the AS3911B AFE and framing implemented in the external microcontroller. ams Datasheet [v1-13] 2015-Jun-18 Page 141 Document Feedback AS3911B − Application Information Transparent Mode After sending the direct command Transparent Mode the external microcontroller directly controls the transmission modulator and gets the Receiver output (control logic becomes “transparent”). The Transparent Mode is entered on rising edge of signal /SS after sending the command Transparent Mode and is maintained as long as the signal /SS is kept high. Before sending the direct command Transparent Mode the Transmitter and Receiver have to be turned on, the AFE has to be configured properly. While the AS3911B is in the Transparent Mode the AFE is controlled directly through SPI interface: • Transmitter modulation is controlled by pin MOSI (high is modulator on) • Signal rx_on is controlled by pin SCLK (high enables RSSI and AGC) • Output of Receiver AM demodulation chain (digitized sub-carrier signal) is sent to pin MISO • Output of Receiver PM demodulation chain (digitized sub-carrier signal) is sent to pin IRQ By controlling the rx_on advanced Receiver features like the RSSI and AGC can be used. The receiver channel selection bits are valid also in Transparent mode, therefore it is possible to use only one of the two channel outputs. In case single channel is selected it is always multiplexed to MISO, while IRQ is kept low. Configuration bits related to the ISO mode, framing and FIFO are of course meaningless in Transparent Mode, all other configuration bits are respected. Use of Transparent Mode to Implement Active Peer to Peer (NFC) Communication: The framing implemented in the AS3911B supports all active modes according to the NFCIP-1 specification (ISO/IEC 18092:2004). In case any amendments to this specification or some custom active NFC communication need to be implemented Transparent mode can be used. There is no special NFC active communication transparent mode, controlling of the Tx modulation and the Rx is done as described above. The difference comparing to the reader transparent mode is that the emission of the carrier field has to be enabled only during Tx. This is done by writing the Operation Control Register before and after Tx. Since with every SPI command the Transparent mode is lost it has to be re-entered. In order to receive the reply in active NFC communication mode only the AM demodulation channel is used. Due to this the Receiver AM channel has to be enabled, while PM can be disabled. Page 142 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Implementing active communication requires detection of external field. Setting the bit en_fd in the Auxiliary Definition Register enables the External Field Detector with Peer Detection Threshold. When bit en_fd is selected and the AS3911B is in Transparent mode, the External Field Detector output is multiplexed to pin IRQ. This enables detection of external target/initiator field and performing RF collision avoidance. In case timing of the NFC Field ON command is correct for the NFC active protocol which is being implemented, these commands can be used in combination with the Transparent mode. These commands are used to perform the RF collision avoidance, switching on the field and timing out the minimum time from switching on the field to start of transmitting the message. After getting the interrupt, the controller generates the message in the Transparent mode. When bit en_fd is set and all bits of the Operation Control Register are set to 0 the AS3911B is in the low power NFC Target Mode (same as in case of setting of targ bit, (see NFCIP-1 Active Communication Target). In this mode initiator field is detected. After getting an IRQ with I_eon flag set, the controller turns on the oscillator, regulator and receiver and performs reception in the Transparent mode. MIFARE™ Classic Compatibility For communication with MIFARE™ Classic compliant devices the bit6 and bit7 from the register 05h can be used to enable Type A custom frames. Alternatively stream mode of AS3911 can be used to send and receive MIFARE™ Classic compliant or custom frames. Stream Mode Stream mode can be used to implement protocols, where the low level framing needed for ISO14443 receive coding can be used and decoded information can be put in FIFO. The main advantage of this mode over the Transparent mode is that timing is generated in the AS3911B therefore the external controller does not have to operate in real time. The stream mode is selected in the Mode Definition Register, the operating options are defined in the Stream Mode Definition Register. Two different modes are supported for tag to reader communication (Sub-carrier and BPSK Stream Modes). General rule for Stream mode is that the first bit sent/received is put on the LSB position of the FIFO byte. After selecting the stream mode the Receiver and Transmitter have to be configured properly (Analog Preset direct command doesn't apply for stream mode). Sub-Carrier Stream Mode: This mode supports protocols where during the tag to reader communication the time periods with sub-carrier signal are interchanged with time periods without modulation (like in the ISO14443A 106 kbit/s mode). In this mode the sub-carrier ams Datasheet [v1-13] 2015-Jun-18 Page 143 Document Feedback AS3911B − Application Information frequency and number of sub-carrier frequency periods in one reporting period is defined. Sub-carrier frequency in the range from fc/64 (212 kHz) to fc/8 (1695 kHz) are supported. Supported number of sub-carrier frequency periods in one reporting period range from two to eight. Start of receive interrupt is sent and the first data bit is put in FIFO after the first reporting time period with sub-carrier is detected. One bit of FIFO data gives information about status of input signal during one reporting period. Logic 1 means that the sub-carrier was detected during reporting period, while 0 means that no modulation was detected during reporting period. End of receive is reported when no sub-carrier signal in more than eight reporting periods have been detected. Figure below depicts an example for setting scf = 01b and scp = 10b. With this setting the sub-carrier frequency is set to fc/32 (424 kHz) and the reporting period to four sub-carrier periods (128/fc - ~106 μs). Figure 130: Example of Sub-Carrier Stream Mode for scf = 01b and scp = 10b Data in FIFO 1 1 0 1 Input signal 32/fc 128/fc BPSK Stream Mode: This mode supports protocols where during the tag to reader communication BPSK code is used (like in the ISO14443B mode). In this mode the sub-carrier frequency and number of sub-carrier frequency periods in one reporting period is defined. Sub-carrier frequency in the range from fc/16 (848 kHz) to fc/4 (3390 kHz) are supported. Supported number of sub-carrier frequency periods in one reporting period range from one to eight. Start of receive interrupt is sent and the first data bit is put in FIFO after the first reporting time period with sub-carrier is detected. Logic 0 is used for the initially detected phase, while logic 1 indicates inverted phase comparing to the initial phase. End of receive is reported when the first reporting period without sub-carrier is detected. Figure below depicts an example for setting scf = 01b and scp = 01b. With this setting the sub-carrier frequency is set to fc/8 (1695 kHz) and the reporting period to two sub-carrier periods (16/fc - ~1.18μs). Page 144 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Application Information Figure 131: Example of BPSK Stream Mode for scf = 01b and scp = 01b Data in FIFO 0 0 1 0 Input signal 8/fc 16/fc Reader to Tag Communication in Stream Mode: Reader to tag communication control is the same for both stream modes. Reader to tag coding is defined by data put in FIFO. The stx bits of Stream Mode Definition Register define the Tx time period during which one bit of FIFO data define the status of transmitter. In case the data bit is set to logic 0 there is no modulation, in case it is logic 1 the transmitted carrier signal is modulated according to current modulation type setting (AM or OOK). Transmission in stream mode is started by sending direct commands Transmit Without CRC or Transmit With CRC. Figure below depicts an example for setting stx = 000b. With this setting the Tx time period is defined to 128/fc (~9,44 μs). Figure 132: Example of Tx in Stream Mode for stx = 000b and OOK Modulation Data in FIFO 0 0 1 0 Output signal 128/fc ams Datasheet [v1-13] 2015-Jun-18 Page 145 Document Feedback AS3911B − Package Drawings & Markings Package Drawings & Markings The device is available in a 32-pin QFN (5x5mm) package. Figure 133: Package Drawings AS3911B YYWWXZZ @ Symbol Min Nom Max A 0.80 0.90 1.00 A1 0 0.02 0.05 A2 - 0.65 1.00 A3 - 0.20 REF - L 0.35 0.40 0.45 q 0º b 0.18 14º 0.25 D 5.00 BSC E 5.00 BSC e 0.50 BSC D2 3.40 0.30 3.50 3.60 E2 3.40 3.50 3.60 D1 - 4.75 BSC - E1 - 4.75 BSC - aaa - 0.15 - bbb - 0.10 - ccc - 0.10 - ddd - 0.05 - eee - 0.08 - fff - 0.10 - N 32 RoHS Green Note(s) and/or Footnote(s): 1. Dimensioning and tolerances conform to ASME Y14.5M-1994. 2. All dimensions are in millimeters. Angles are in degrees. 3. Co-planarity applies to the exposed heat slug as well as the terminal. 4. Radius on terminal is optional. 5. N is the total number of terminals. 6. This drawing is subject to change without notice. Figure 134: Marking YYWWXZZ YY WW X ZZ @ Year Manufacturing week Plant Identifier Traceability code Sublot Identifier Page 146 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Ordering & Contact Information Ordering & Contact Information Figure 135: Ordering Information Ordering Code Type Marking Delivery Form AS3911B-AQFT Packaged 32-pin QFN (5x5mm) AS3911B Tape & Reel AS3911B-ASWB Sorted wafer n.a. Wafer Box Buy our products or get free samples online at: www.ams.com/ICdirect Technical Support is available at: www.ams.com/Technical-Support Provide feedback about this document at: www.ams.com/Document-Feedback For further information and requests, e-mail us at: [email protected] For sales offices, distributors and representatives, please visit: www.ams.com/contact Headquarters ams AG Tobelbaderstrasse 30 8141 Unterpremstaetten Austria, Europe Tel: +43 (0) 3136 500 0 Website: www.ams.com ams Datasheet [v1-13] 2015-Jun-18 Page 147 Document Feedback AS3911B − RoHS Compliant & ams Green Statement RoHS Compliant & ams Green Statement RoHS: The term RoHS compliant means that ams AG products fully comply with current RoHS directives. Our semiconductor products do not contain any chemicals for all 6 substance categories, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, RoHS compliant products are suitable for use in specified lead-free processes. ams Green (RoHS compliant and no Sb/Br): ams Green defines that in addition to RoHS compliance, our products are free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material). Important Information: The information provided in this statement represents ams AG knowledge and belief as of the date that it is provided. ams AG bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. ams AG has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. ams AG and ams AG suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. Page 148 Document Feedback ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Copyrights & Disclaimer Copyrights & Disclaimer Copyright ams AG, Tobelbader Strasse 30, 8141 Unterpremstaetten, Austria-Europe. Trademarks Registered. All rights reserved. The material herein may not be reproduced, adapted, merged, translated, stored, or used without the prior written consent of the copyright owner. Devices sold by ams AG are covered by the warranty and patent indemnification provisions appearing in its General Terms of Trade. ams AG makes no warranty, express, statutory, implied, or by description regarding the information set forth herein. ams AG reserves the right to change specifications and prices at any time and without notice. Therefore, prior to designing this product into a system, it is necessary to check with ams AG for current information. This product is intended for use in commercial applications. Applications requiring extended temperature range, unusual environmental requirements, or high reliability applications, such as military, medical life-support or life-sustaining equipment are specifically not recommended without additional processing by ams AG for each application. This product is provided by ams AG “AS IS” and any express or implied warranties, including, but not limited to the implied warranties of merchantability and fitness for a particular purpose are disclaimed. ams AG shall not be liable to recipient or any third party for any damages, including but not limited to personal injury, property damage, loss of profits, loss of use, interruption of business or indirect, special, incidental or consequential damages, of any kind, in connection with or arising out of the furnishing, performance or use of the technical data herein. No obligation or liability to recipient or any third party shall arise or flow out of ams AG rendering of technical or other services. Legal Notice: Capacitive wakeup feature is covered by patent US6150948 (LOW-POWER RADIO FREQUENCY IDENTIFICATION READER) for which ams AG is exclusive licensee including, not limited to copyrights, patents, trademarks and trade secrets related thereto. Purchase of ams AG ICs with MIFARE Classic™ compatibility: This ams AG IC offers modes to be compatible with MIFARE™ Classic RFID tags. This allows to build MIFARE™ Classic compatible reader systems. MIFARE™ and MIFARE™ Classic are trademarks of NXP B.V., High Tech Campus 60 NL-5656 AG EINDHOVEN, NL. Purchase of ams AG’s MIFARE™ Classic compatible products does not provide a license of any NXP rights, in particular does not provide the right to use MIFARE™ or MIFARE™ Classic as a trademark to brand such systems. Purchase of ams AG’s ICs with ISO/IEC 14443 type B functionality: This ams AG IC is ISO/IEC 14443 Type B software enabled and is licensed under Innovatron’s Contactless Card patents license for ISO/IEC 14443 B. The license includes the right to use the IC in systems and/or end-user equipment. ams Datasheet [v1-13] 2015-Jun-18 Page 149 Document Feedback AS3911B − Document Status Document Status Document Status Product Preview Preliminary Datasheet Datasheet Datasheet (discontinued) Page 150 Document Feedback Product Status Definition Pre-Development Information in this datasheet is based on product ideas in the planning phase of development. All specifications are design goals without any warranty and are subject to change without notice Pre-Production Information in this datasheet is based on products in the design, validation or qualification phase of development. The performance and parameters shown in this document are preliminary without any warranty and are subject to change without notice Production Information in this datasheet is based on products in ramp-up to full production or full production which conform to specifications in accordance with the terms of ams AG standard warranty as given in the General Terms of Trade Discontinued Information in this datasheet is based on products which conform to specifications in accordance with the terms of ams AG standard warranty as given in the General Terms of Trade, but these products have been superseded and should not be used for new designs ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Revision Information Revision Information Changes from 1-12 (2015-Mar-31) to current revision 1-13 (2015-Jun-18) Page Added Figure 4 4 Updated Figure 5 5 Updated text under Transmitter 14 Updated text under Quartz Crystal Oscillator 30 Updated Figure 135 147 Note(s) and/or Footnote(s): 1. Page and figure numbers for the previous version may differ from page and figure numbers in the current revision. 2. Correction of typographical errors is not explicitly mentioned. ams Datasheet [v1-13] 2015-Jun-18 Page 151 Document Feedback AS3911B − Content Guide Content Guide Page 152 Document Feedback 1 2 3 3 General Description Key Benefits & Features Applications Block Diagram 4 7 Pin Assignment Absolute Maximum Ratings 8 8 8 8 9 9 Electrical Characteristics Operating Conditions DC/AC Characteristics for Digital Inputs and Outputs CMOS Inputs: CMOS Outputs: Electrical Specification 12 12 Typical Operating Characteristics Thermal Resistance and Max. Power Dissipation 13 14 14 14 14 15 15 15 15 16 16 16 16 16 16 Detailed Description Transmitter Receiver Phase and Amplitude Detector A/D Converter Capacitive Sensor External Field Detector Quartz Crystal Oscillator Power Supply Regulators POR and Bias RC Oscillator and Wake-up Timer ISO14443 and NFCIP-1 Framing FIFO Control Logic SPI Interface 17 17 17 19 19 20 21 23 24 25 26 27 28 29 30 30 31 32 32 33 Application Information Operating Modes Transmitter Slow Transmitter Ramping Receiver Demodulation Stage Filtering and Gain Stages Digitizing Stage AGC, Squelch and RSSI Receiver in NFCIP-1 Active Communication Mode Capacitive Sensor Capacitor Sensor Calibration Wake-Up Mode Auto-Averaging Quartz Crystal Oscillator Timers Mask Receive Timer and No-Response Timer General Purpose Timer Wake-Up Timer A/D Converter ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Content Guide 33 33 34 35 35 35 36 38 39 39 39 40 40 42 43 43 44 45 45 46 47 48 49 50 53 53 53 54 55 55 57 57 57 58 58 59 59 59 60 60 60 61 61 61 61 61 63 67 68 69 70 71 ams Datasheet [v1-13] 2015-Jun-18 Phase and Amplitude Detector Phase Detector Amplitude Detector External field Detector Peer Detection Threshold Collision Avoidance Threshold Power Supply System VSP_RF Regulator VSP_A and VSP_D Regulators Power-Down Support Block Measurement of Supply Voltages Communication to External Microcontroller Serial Peripheral Interface (SPI) Writing of Data to Addressable Registers (Write Mode) Reading of Data from Addressable Registers (Read Mode) Loading Transmitting Data into FIFO Reading Received Data from FIFO Direct Command Mode Direct Command Chaining SPI Timing Interrupt Interface FIFO Water Level and FIFO Status Registers Pin MCU_CLK Direct Commands Set Default Clear Transmit Commands NFC Field ON Commands Go to Normal NFC Mode Analog Preset Mask Receive Data and Unmask Receive Data Measure Amplitude Squelch Reset Rx Gain Adjust Regulators Calibrate Modulation Depth Calibrate Antenna Measure Phase Clear RSSI Transparent Mode Calibrate Capacitive Sensor Measure Capacitance Measure Power Supply Start Timers Test Access Test Mode Entry and Access to Test Registers Registers IO Configuration Register 1 IO Configuration Register 2 Operation Control Register Mode Definition Register Bit Rate Definition Register Page 153 Document Feedback AS3911B − Content Guide 72 74 75 76 78 79 80 81 82 83 83 84 84 86 86 87 87 88 89 90 91 92 93 94 95 95 96 96 97 98 98 99 100 100 101 101 104 105 107 109 110 111 111 112 113 114 114 115 116 117 117 118 Page 154 Document Feedback ISO14443A and NFC 106kb/s Settings Register ISO14443B Settings Register 1 ISO14443B and FeliCa Settings Register Stream Mode Definition Register Auxiliary Definition Register Receiver Configuration Register 1 Receiver Configuration Register 2 Receiver Configuration Register 3 Receiver Configuration Register 4 Mask Receive Timer Register No-Response Timer Register 1 No-Response Timer Register 2 General Purpose and No-Response Timer Control Register General Purpose Timer Register 1 General Purpose Timer Register 2 Mask Main Interrupt Register Mask Timer and NFC Interrupt Register Mask Error and Wake-Up Interrupt Register Main Interrupt Register Timer and NFC Interrupt Register Error and Wake-Up Interrupt Register FIFO Status Register 1 FIFO Status Register 2 Collision Display Register Number of Transmitted Bytes Register 1 Number of Transmitted Bytes Register 2 NFCIP Bit Rate Detection Display Register A/D Converter Output Register Antenna Calibration Control Register Antenna Calibration Target Register Antenna Calibration Display Register AM Modulation Depth Control Register AM Modulation Depth Display Register RFO AM Modulated Level Definition Register RFO Normal Level Definition Register External Field Detector Threshold Register Regulator Voltage Control Register Regulator and Timer Display Register RSSI Display Register Gain Reduction State Register Capacitive Sensor Control Register Capacitive Sensor Display Register Auxiliary Display Register Wake-Up Timer Control Register Amplitude Measurement Configuration Register Amplitude Measurement Reference Register Amplitude Measurement Auto-Averaging Display Register Amplitude Measurement Display Register Phase Measurement Configuration Register Phase Measurement Reference Register Phase Measurement Auto-Averaging Display Register Phase Measurement Display Register ams Datasheet [v1-13] 2015-Jun-18 AS3911B − Content Guide 119 Capacitance Measurement Configuration Register 120 Capacitance Measurement Reference Register 120 Capacitance Measurement Auto-Averaging Display Register 121 Capacitance Measurement Display Register 121 IC Identity Register 122 Power-Up Sequence 122 Reader Operation 123 Anticollision – ISO 14443A 125 Setting up AS3911B for ISO 14443A Anticollision 126 REQA and WUPA 127 ANTICOLLISION Procedure 129 FeliCa Reader Mode 129 FeliCa Transmission 129 FeliCa Reception 129 NFCIP-1 Operation 130 NFCIP-1 Passive Communication Initiator 132 NFCIP-1 Active Communication Initiator 134 NFCIP-1 Active Communication Target 136 AM Modulation Depth: Definition and Calibration 137 AM Modulation Depth Definition Using the ‘Calibrate Modulation Depth’ Direct Command 138 AM Modulation Depth Definition using the ‘RFO AM Modulated Level Definition’ Register 139 Antenna Tuning 140 Antenna Tuning Using Direct Command ‘Calibrate Antenna’ 141 Stream Mode and Transparent Mode 142 Transparent Mode 143 MIFARE™ Classic Compatibility 143 Stream Mode 146 147 148 149 150 151 ams Datasheet [v1-13] 2015-Jun-18 Package Drawings & Markings Ordering & Contact Information RoHS Compliant & ams Green Statement Copyrights & Disclaimer Document Status Revision Information Page 155 Document Feedback