AZ DISPLAYS SPECIFICATIONS FOR LIQUID CRYSTAL DISPLAY CUSTOMER APPROVAL ※PART NO. : ATM0700D8B-T (AZ DISPLAYS) VER1.2 APPROVAL COMPANY CHOP CUSTOMER COMMENTS AZ DISPLAYS ENGINEERING APPROVAL DESIGNED BY YGB CHECKED BY APPROVED BY ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 REVISION RECORD REVISION REVISION DATE VER1.0 2012-07-30 VER1.1 2013-05-24 4 VER1.2 2013-07-31 ALL AZ DISPLAYS PAGE CONTENTS FIRST ISSUED CORRECT PIN DEFINITION CHANGE SPEC FORMAT 1 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 ※ CONTENTS 1. GENERAL SPECIFICATIONS 2. PIN ASSIGNMENT 3. OPERATING SPECIFICATIONS 4. OPTICAL SPECIFICATIONS 5. RELIABILITY TEST 6. PRECAUTION FOR USING LCM 7. MECHANICAL DRAWING 8. PACKAGE DRAWING 9. INSPECTION SPECIFICATION AZ DISPLAYS 2 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 1. GENERAL SPECIFICATIONS Item Specification 1. LCD size 7.0 inch(Diagonal) 2. Driver element a-Si TFT active matrix 3. Resolution 800x(RGB) x 480 4. Normally white, Transmissive Display mode 5. Dot pitch (W*H) 0.0642mm(W) x 0.1790mm(H) 6. Pixel pitch(W*H) 0.1926mm(W) x 0.1790mm(H) 7. Active area(W*H) 154.08mm(W) x 85.92mm(H) 8. Module size (W*H) 164.90mm(W) x 100.0mm(H) x 7.1mm(D) 9. Surface treatment Anti-glare 10. Bezel material Remark Note 1 Galvanized sheet 11. Color arrangement RGB-stripe 12. Color 16.7M 13. Interface 24bit RGB interface 14. Weight 206g(Typ.) 15. RoHS ROHS compliant Note 1: Please refer to mechanical drawing. AZ DISPLAYS 3 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 2. PIN ASSIGNMENT TFT LCD Panel Driving Section FPC Connector is used for the module electronics interface. The recommended model is FH12A-50S-0.5SH manufactured by Hirose. Pin No. Symbol Function Level Note 1,2 VLED+ Power for LED backlight(Anode) P 3,4 VLED- Power for LED backlight(Cathode) P 5 GND Power ground P 6 VCOM Common voltage P 7 DVDD Power for digital circuit P 8 MODE DE/SYNC mode select I 9 DE Data input enable I 10 VS Vertical sync input I 11 HS Horizontal sync input I 12~17 B7~B2 Blue data I 18~19 B1~B0 Blue data I 20~25 G7~G2 Green data I 26~27 G1~G0 Green data I 28~33 R7~R2 Red data I 34~35 R1~R0 Red data I 36 GND Power ground P 37 DCLK Sample clock I 38 GND Power ground P 39 L/R Left/Right selection I Note 4,5 40 U/D Up/Down selection I Note 4,5 41 VGH Gate on voltage P 42 VGL Gate off voltage P 43 AVDD Power for analog circuit P 44 RESET Global reset pin I 45 NC No connection -- 46 VCOM Common voltage P 47 DITHB Dithering function I 48 GND Power ground P 49~50 NC No connection -- Note 1 Note 2 Note 2 Note 2 Note 3 Note 6 Note 7 I: input, O: output, P: Power Note 1: DE/SYNC mode select. Normally pull high. When select DE mode, MODE=”1”, VS and HS must pull high. When select SYNC mode, MODE= ”0”, DE must be grounded. Note 2: When input 18 bits RGB data, the two low bits of R,G and B data must be grounded. Note 3: Data shall be latched at the falling edge of DCLK. AZ DISPLAYS 4 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 Note 4: Selection of scanning mode Setting of scan control input U/D L/R GND DVDD GND DVDD DVDD GND GND DVDD Scanning direction Up to down,left to right Down to up,right to left Up to down,right to left Down to up,left to right Note 5: Definition of scanning direction. Refer to the figure as below: Note 6: Global reset pin. Active low to enter reset state. Suggest to connect with an RC reset circuit for stability. Normally pull high. Note 7: Dithering function enable control, normally pull high. When DITHB=”1”,Disable internal dithering function, When DITHB=”0”,Enable internal dithering function, AZ DISPLAYS 5 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 Tout Panel Section FPC Connector is used for the module electronics interface. The recommended model is FH12-4S-1SH manufactured by Hirose. Pin No. Symbol I/O Function Remark 4 Y1 Top Top electrode – differential analog 3 X1 Left Left electrode – differential analog 2 Y2 Bottom Bottom electrode – differential analog 1 X2 Right Right electrode – differential analog Y1 X1 X2 Y2 4 1 TP LAYOUT AZ DISPLAYS 6 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 3. Operating Specification 3.1 ABSOLUTE MAXIMUM RATINGS Item Symbol Values Unit Remark Min. Max. DVDD -0.3 5.0 V AVDD 6.5 13.5 V VGH -0.3 40 V VGL -20 0.3 V VGH-VGL -- 40 V Operation Temperature TOP -20 70 ºC Storage Temperature TST -30 80 ºC LED Reverse Voltage VR - 1.2 V Each LED Note 2 LED Forward Current IF 25 mA Each LED Power Voltage Note 1: The absolute maximum rating values of this product are not allowed to be exceeded at any times. Should a module be used with any of the absolute maximum ratings exceeded, the characteristics of the module may not be recovered, or in an extreme case, the module may be permanently destroyed. Note 2: VR Conditions: Zener Diode 20mA 3.1.1 Typical Operation Conditions Item Values Unit Remark 3.6 V Note 2 10.4 10.6 V 15.3 16.0 16.7 V VGL -7.7 -7 -6.3 V VCOM 3.8 4.0 4.2 V Input Logic High Voltage VIH 0.7DVDD -- DVDD V Note 3 Input Logic Low Voltage VIL 0 -- 0.3DVDD V Note 3 Power Voltage Input Signal Voltage Symbol Min. Typ. Max. DVDD 3.0 3.3 AVDD 10.2 VGH Note 1: Be sure to apply DVDD and VGL to the LCD first, and then apply VGH. Note 2: DVDD setting should match the signals output voltage (refer to Note 3) of customer’s system board. Note 3: DCLK,HS,VS,RESET,U/D, L/R,DE,R0~R7,G0~G7,B0~B7,MODE,DITHB. 3.1.2 Current Consumption Item Power Voltage AZ DISPLAYS Symbol Values Unit Remark 1.0 mA VGH=16.0V 0.2 1.0 mA VGL=-7.0V -- 4.0 10 mA DVDD=3.3V -- 20 50 mA AVDD=10.4V Min. Typ. Max. IGH -- 0.2 IGL -- IDVDD IAVDD 7 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 3.1.3 Backlight driving conditions Item Symbol Voltage for LED Backlight Values Unit Remark 10.5 V Note 1 200 210 mA -- -- Hr Min. Typ. Max. VL 9.0 9.9 Current for LED Backlight IL 190 LED life time -- 30000 Note 2 Note 1: The LED Supply Voltage is defined by the number of LED at Ta=25℃ and IL =200mA. Note 2: The “LED life time” is defined as the module brightness decrease to 50% original brightness at Ta=25℃ and IL =200mA. 3.2 Power Sequence a.Power on: DVDD→VGL→VGH→Data→B/L b.Power off: B/L→Data→VGH→VGL→DVDD Note: Data include R0~R7, B0~B7, GO~G7, U/D, L/R, DCLK, HS,VS,DE. AZ DISPLAYS 8 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 3.3 Timing Characteristics 3.3.1 AC Electrical Characteristics Item Symbol Values Min. Typ. Max. Unit HS Setup Time Thst 8 -- -- ns HS Hold Time Thhd 8 -- -- ns VS Setup Time Tvst 8 -- -- ns VS Hold Time Tvhd 8 -- -- ns Data Setup Time Tdsu 8 -- -- ns Data Hold Time Tdhd 8 -- -- ns DE Setup Time Tesu 8 -- -- ns DE Hold Time Tehd 8 -- -- ns DVDD Power On Slew Time TPOR -- -- 20 ms Reset Pulse Width TRst 1 -- -- ms DCLK Cycle Time Tcoh 20 -- -- ns DCLK Pulse Duty Tcwh 40 50 60 % AZ DISPLAYS Remark From 0 to 90% DVDD 9 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 3.3.2 Data Input Format Figure 3.1 Horizontal input timing diagram. Figure 3.2 Vertical input timing diagram. AZ DISPLAYS 10 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 3.3.3 Timing Item Symbol Values Min. Typ. Max. Unit Horizontal Display Area thd -- 800 -- DCLK DCLK Frequency fclk 26.4 33.3 46.8 MHz th 862 1056 1200 DCLK thpw 1 -- 40 DCLK HS Blanking thb 46 46 46 DCLK HS Front Porch thfp 16 210 354 DCLK One Horizontal Line HS Pulse Width Item Symbol Values Min. Typ. Max. Unit Vertical Display Area tvd -- 480 -- TH VS Period Time tv 510 525 650 TH VS Pulse Width tvpw 1 -- 20 TH VS Blanking tvb 23 23 23 TH VS Front Porch tvfp 7 22 147 TH AZ DISPLAYS Remark Remark 11 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 4.0 OPTICAL SPECIFICATIONS Item Viewing Angle (CR≥10) Response Time Contrast Ratio Symbol Condition θL θR Min. Typ. Max. Φ=180o(9 O'CLOCK) 60 70 -- Φ=0o(3 O'CLOCK) 60 70 -- o Luminance Luminance Uniformity Unit Remark Note 1 degree θT Φ=90 (12 O'CLOCK) 60 70 -- θB Φ=270o(6 O'CLOCK) 40 50 -- TON -- 10 20 msec Note 3 TOFF -- 15 30 msec Note 3 CR 400 500 -- -- Note 4 0.26 0.31 0.36 -- Note 2 0.28 0.33 0.38 -- Normal WX Color Chromaticity Values Θ=Φ=0 WY o L 350 400 -- cd/m YU 75 80 -- % Note 5 Note 6 2 Note 6 Note 7 Test Conditions: 1. IL=200mA (Backlight current), the ambient temperature is 25℃. 2. The test systems refer to Note 2. Note 1: Definition of viewing angle range Figure 4.1 Definition of viewing angle. AZ DISPLAYS 12 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 Note 2: Definition of optical measurement system. The optical characteristics should be measured in dark room. After 30 minutes operation, the optical properties are measured at the center point of the LCD screen. (Response time is measured by Photo detector TOPCON Figure 4.2 Optical measurement system setup Note 3: Definition of Response time The response time is defined as the LCD optical switching time interval between “White” state and “Black” state. Rise time (TON) is the time between photo detector output intensity changed from 90% to 10%. And fall time (TOFF) is the time between photo detector output intensity changed from 10% to 90%. Figure 4.3 Definition of response. AZ DISPLAYS 13 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 Note 4: Definition of contrast ratio Note 5: Definition of color chromaticity (CIE1931) Color coordinates measured at center point of LCD. Note 6: All input terminals LCD panel must be ground while measuring the center area of the panel. Note 7: Definition of Luminance Uniformity Active area is divided into 9 measuring areas (Refer to Fig. 4-4 ).Every measuring point is placed at the center of each measuring area. Figure 4.3 Definition of measuring points. Bmax: The measured maximum luminance of all measurement position. Bmin: The measured minimum luminance of all measurement position. AZ DISPLAYS 14 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 5. RELIABILITY TEST Item High temperature storage Low temperature storage High temperature operation Low temperature operation High temperature/High humidity operation Thermal Shock Vibration test Mechanical shock Package vibration test Package drop test Electro static discharge Test Condition Item Ta= 80 ºC 240hrs Ta=-30 ºC 240hrs Ts= 70 ºC 240hrs Ts=-20 ºC 240hrs 90% RH 60ºC 240hrs -30℃/30 min ~ +80℃/30 min for a total 100 cycles, Start with cold temperature and end with high temperature. Remark Note 1 Note 4 Note 1 Note 4 Note 2 Note 4 Note 1 Note 4 Note 4 Note 4 Freq:10~55~10Hz Amplitude:1.5mm 2 hours for each direction of X,Y,Z (6 hours for total) 100G 6ms,±X, ±Y, ±Z 3 times for each direction Random Vibration : 0.015G*G/Hz from 5-200HZ, -6dB/Octave from 200-500HZ 2 hours for each direction of X. Y. Z. (6 hours for total) Height:60 cm 1 corner, 3 edges, 6 surfaces ± 2KV, Human Body Mode, 100pF/1500Ω Note 1: Ta is the ambient temperature of samples. Note 2: Ts is the temperature of panel’s surface. Note 3: In the standard condition, there shall be no practical problem that may affect the display function. After the reliability test, the product only guarantees operation, but don’t guarantee all of the cosmetic specification. Note 4: Before cosmetic and function test, the product must have enough recovery time, at least 2 hours at room temperature. AZ DISPLAYS 15 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 6. PRECAUTION FOR USING LCM 6. When design the product with this LCD Module, make sure the viewing angle matches to its purpose of usage. 7. As LCD panel is made of glass substrate, Dropping the LCD module or banging it against hard objects may cause cracking or fragmentation. Especially at corners and edges. 8. Although the polarizer of this LCD Module has the anti-glare coating, always be careful not to scratch its surface. Use of a plastic cover is recommended to protect the surface of polarizer. 9. If the LCD module is stored at below specified temperature, the LC material may freeze and be deteriorated. If it is stored at above specified temperature, the molecular orientation of the LC material may change to Liquid state and it may not revert to its original state. Excessive temperature and humidity could cause polarizer peel off or bubble. Therefore, the LCD module should always be stored within specified temperature range. 10. Saliva or water droplets must be wiped off immediately as those may leave stains or cause color changes if remained for a long time. Water vapor will cause corrosion of ITO electrodes. 11. If the surface of LCD panel needs to be cleaned, wipe it swiftly with cotton or other soft cloth. If it is not still clean enough, blow a breath on the surface and wipe again. 12. The module should be driven according to the specified ratings to avoid malfunction and permanent damage. Applying DC voltage cause a rapid deterioration of LC material. Make sure to apply alternating waveform by continuous application of the M signal. Especially the power ON/OFF sequence should be kept to avoid latch-up of driver LSIs and DC charge up to LCD panel. 13. Mechanical Considerations a) LCM are assembled and adjusted with a high degree of precision. Avoid excessive shocks and do not make any alterations or modifications. The following should be noted. b) Do not tamper in any way with the tabs on the metal frame. c) Do not modify the PCB by drilling extra holes, changing its outline, moving its components or modifying its pattern. d) Do not touch the elastomer connector; especially insert a backlight panel (for example, EL). e) When mounting a LCM makes sure that the PCB is not under any stress such as bending or twisting. Elastomer contacts are very delicate and missing pixels could result from slight dislocation of any of the elements. f) Avoid pressing on the metal bezel, otherwise the elastomer connector could be deformed and lose contact, resulting in missing pixels. 14. Static Electricity a) Operator Wear the electrostatics shielded clothes because human body may be statically charged if not ware shielded clothes. Never touch any of the conductive parts such as the LSI pads; the copper leads on the PCB and the interface terminals with any parts of the human body. b) Equipment There is a possibility that the static electricity is charged to the equipment, which has a function of peeling or friction action (ex: conveyer, soldering iron, working table). Earth the equipment through proper resistance (electrostatic earth: 1x108 ohm). Only properly grounded soldering irons should be used. If an electric screwdriver is used, it should be well grounded and shielded from commutator sparks. The normal static prevention measures should be observed for work clothes and working benches; for the latter conductive (rubber) mat is recommended. c) Floor Floor is the important part to drain static electricity, which is generated by operators or equipment. There is a possibility that charged static electricity is not properly drained in case of insulating floor. Set the electrostatic earth (electrostatic earth: 1x108 ohm). d) Humidity Proper humidity helps in reducing the chance of generating electrostatic charges. Humidity should be kept over 50%RH. e) Transportation/storage The storage materials also need to be anti-static treated because there is a possibility that the human body or storage materials such as containers may be statically charged by friction or peeling. The modules should be kept in antistatic bags or other containers resistant to static for storage. f) Soldering Solder only to the I/O terminals. Use only soldering irons with proper grounding and no leakage. Soldering temperature : 280°C ± 10°C Soldering time: 3 to 4 sec. Use eutectic solder with resin flux fill. If flux is used, the LCD surface should be covered to avoid flux spatters. Flux residue should be removed afterwards. g) Others AZ DISPLAYS 16 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 The laminator (protective film) is attached on the surface of LCD panel to prevent it from scratches or stains. It should be peeled off slowly using static eliminator. Static eliminator should also be installed to the workbench to prevent LCD module from static charge. 15. Operation a) Driving voltage should be kept within specified range; excess voltage shortens display life. b) Response time increases with decrease in temperature. c) Display may turn black or dark blue at temperatures above its operational range; this is (however not pressing on the viewing area) may cause the segments to appear “fractured”. d) Mechanical disturbance during operation (such as pressing on the viewing area) may cause the segments to appear “fractured”. 16. If any fluid leaks out of a damaged glass cell, wash off any human part that comes into contact with soap and water. The toxicity is extremely low but caution should be exercised at all the time. 17. Disassembling the LCD module can cause permanent damage and it should be strictly avoided. 18. LCD retains the display pattern when it is applied for long time (Image retention). To prevent image retention, do not apply the fixed pattern for a long time. Image retention is not a deterioration of LCD. It will be removed after display pattern is changed. 19. Do not use any materials, which emit gas from epoxy resin (hardener for amine) and silicone adhesive agent (dealcohol or deoxym) to prevent discoloration of polarizer due to gas. 20. Avoid the exposure of the module to the direct sunlight or strong ultraviolet light for a long time. The brightness of LCD module may be affected by the routing of CCFL cables due to leakage to the chassis through coupling effect. The inverter circuit needs to be designed taking the level of leakage current into consideration. Thorough evaluation is needed for LCD module and inverter built into its host equipment to ensure specified brightness. AZ DISPLAYS 17 AZ DISPLAYS 50 Note:Dimensions marked with "( )" are for reference. Bezel material: stainless steel General tolerance: ± 0.3 1 DISPLAY CENTER Detail A(S = 2:1) 50 1 LABLE ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 7. MECHANICAL DRAWING 18 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 8. PACKAGE DRAWING AZ DISPLAYS 19 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 9.INSPECTION SPECIFICATION 1. SCOPE SPECIFICATIONS CONTAIN 1.1 DISPLAY QUALITY EVALUATION 1.2 MECHANICS SPECIFICATION 2. SAMPLING PLAN UNLESS THERE IS OTHER AGREEMENT, THE SAMPLING PLAN FOR INCOMING INSPECTION SHALL FOLLOW MIL-STD-105E. 2.1 LOT SIZE: QUANTITY PER SHIPMENT AS ONE LOT (DIFFERENT MODEL AS DIFFERENT LOT ). 2.2 SAMPLING TYPE: NORMAL INSPECTION, SINGLE SAMPLING. 2.3 SAMPLING LEVEL: LEVEL II. 2.4 AQL: ACCEPTABLE QUALITY LEVEL MAJOR DEFECT: AQL=0.65 MINOR DEFECT: AQL=1.0 3. PANEL INSPECTION CONDITION 3.1 ENVIRONMENT: ROOM TEMPERATURE: 25±5°C. HUMIDITY: 65±5% RH. ILLUMINATION: 300 ~ 700 LUX. 3.2 INSPECTION DISTANCE: 35±5 CM 3.3 INSPECTION ANGLE: THE VISION OF INSPECTOR SHOULD BE PERPENDICULAR TO THE SURFACE OF THE MODULE. 3.4 INSPECTION TIME: PERCEPTIBILITY TEST TIME: 20 SECONDS MAX. 4. DISPLAY QUALITY 4.1 FUNCTION RELATED: THE FUNCTION DEFECTS OF LINE DEFECT, ABNORMAL DISPLAY, AND NO DISPLAY ARE CONSIDERED MAJOR DEFECTS. 4.2 BRIGHT/DARK DOTS: Note: 1: The definition of dot: The size of a defective dot over 1/2 of whole dot is regarded as one defective dot. Bright dot: Dots appear bright and unchanged in size in which LCD panel is displaying under black pattern. The bright dot defect must be visible through 2% ND filter Dark dot: Dots appear dark and unchanged in size in which LCD panel is displaying under pure red, green, blue pattern. 4.3 Pixel Definition: Note 1: If pixel or partial sub-pixel defects exceed 50% of the affected pixel or sub-pixel area, it shall be considered as1 defect. Note 2: There should be no distinct non-uniformity visible through 2% ND Filter within 2 sec inspection times. AZ DISPLAYS 20 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 4.4Visual Inspection specifications: AZ DISPLAYS 21 ATM0700D8B-T(AZ DISPLAYS) TFT MODULE VER1.2 Note: Extraneous substance and scratch not affecting the display of image, for instance, extraneous substance under polarizer film but outside the display area, or scratch on metal bezel and backlight module or polarizer film outside the display area, shall not be considered as defective or non-conforming. AZ DISPLAYS 22