HEC-100RTA-48QSCA Rev A1.0

HEC-100RTA-48QSCA Rev A1.0
A. Features
High Efficiency (Up to 90%).
Active Power Factor Correction (Typical 0.96).
Isolation Class I (With FG)
All-Round Protection: OVP/SCP/OTP/OPP.
Fully isolated Metal case with IP67 and damp/ wet location.
1-10V, PWM, and resistance dimming function.
B. Description
The HEC-100RTA-48QSCA Series operate from a 90 ~ 305Vac input range. They are designed to be highly efficient
and highly reliable. Features include over voltage protection, short circuit protection, and over temperature protection.
C. Models
Input
Voltage
Range
Output
Voltage
Range
Note 1
Note 4
90 ~ 305Vac
28-48V
Output
Current
2100mA
Max.
Output
Power
Efficiency
Power Factor
Note 2
Note 2
100 W
90%
0.96
Model Number
HEC-100RTA-48QSCA
D. Electronic Specifications
- Input Specifications
Parameter
Min.
Typ.
Max.
Input Voltage (V)
90
-
305
Input Frequency (Hz)
47
Notes
63
-
-
1.5
Measured at full load and 100Vac input.
-
-
0.5
Measured at full load and 277Vac input.
Leakage Current (mA)
-
-
0.7
At 277Vac 60Hz input.
Inrush Current (A)
-
-
40
-
0.16 A2s
At 220Vac input 25°C Cold Start. Duration=100µs,
10%Ipk-10%Ipk.
0.9
-
-
-
20
25
Input AC Current (A)
Inrush Current (I2t)
Power Factor
At 277Vac input, full load.
THD (%)
http://www.hec-group.com.tw/
[email protected]
TEL:+886-6-356-0606
FAX:+886-6-356-0505
1
HEC-100RTA-48QSCA Rev A1.0
- Output Specifications
Parameter
Min.
Typ.
Max.
Notes
Output Current (mA)
Io = 2100 mA
No Load Output Voltage (V)
1995
2205
-
-
Output Ripple Voltage (V)
-
-
Output Voltage Overshoot (%)
-
-
110
Line Regulation (%)
-
-
±3
Load Regulation (%)
-
-
±5
Turn-on Delay Time (s)
-
0.5
1.0
Min.
Typ.
Max.
-
-
-
-
320,000
-
Io = 2100 mA
63
1%
Vo max
There will be no damage or hazardous conditions
occurred with no loading.
Measured by 20 MHz bandwidth oscilloscopes and the
output paralleled a 0.1uF ceramic capacitor and a
10uF electrolytic capacitor.
At full load condition.
Measured at 220Vac input.
- General Specifications
Parameter
Efficiency (%)
Io = 2100 mA
Efficiency (%)
Io = 2100 mA
MTBF (hours)
Life Time (hours)
Case Temperature (°C)
-
Dimensions Millimeters(L × W × H)
88
90
100,000
-
-
85
Notes
Measured at full load and 120Vac input.
Measured at full load and 277Vac input.
Measured at full load 50°C ambient temperature
(MIL-HDBK-217F).
Measured at rated input voltage with full load, Case
temperature=60°C @ Tc point.See life time vs. Tc
curve for the details.
70*ψ130
- Protection Functions
Parameter
Min.
Typ.
Max.
1.50
Over Voltage Protection
Vomax
Notes
In the event of an over-voltage condition, the LED
Drives shall Shut down o/p voltage, re-power on to
recover.
Over Temperature Protection
Shut down o/p voltage with re-power on to recovery.
Short Circuit Protection
No damage shall occur when any output operating in a short circuit condition. The
power supply shall be self-recovery when the fault condition is removed.
http://www.hec-group.com.tw/
[email protected]
TEL:+886-6-356-0606
FAX:+886-6-356-0505
2
HEC-100RTA-48QSCA Rev A1.0
- Environmental Specifications
Parameter
Min.
Typ.
Max.
Notes
Operating Temperature (°C)
-40
-
+70
Humidity: 20% RH to 80% RH; See Derating Curve for
more details.
Storage Temperature (°C)
-40
-
+80
Humidity: 10% RH to 90% RH.
- Safety and EMC Compliance
Safety Category
Standard
UL/CUL
UL8750, UL 1012, CSA C22.2 No. 107.1
CE
EN 61347-1, EN61347-2-13.
EMI Standards
Notes
EN 55015
Conducted emission Test & Radiated emission Test.
EN 61000-3-2
Harmonic current emissions.
EN 61000-3-3
Voltage fluctuations & flicker.
FCC Part 15
FCC 47 CFR Part 15 Subpart B, ICES-003 Issue 4 ANSI C63.4-2003
EMS Standards
Notes
EN 61000-4-2
Electrostatic Discharge (ESD): 8 KV air discharge, 4 KV contact discharge.
EN 61000-4-3
Radio-Frequency Electromagnetic Field Susceptibility Test-RS.
EN 61000-4-4
Electrical Fast Transient / Burst-EFT: Level 2, Criteria A.
EN 61000-4-5
Surge Immunity Test: AC Power Line: line to line 2 KV.
EN 61000-4-6
Conducted Radio Frequency Disturbances Test-CS.
EN 61000-4-8
Power Frequency Magnetic Field Test.
EN 61000-4-11
Voltage Dips.
EN 61547
Electromagnetic Immunity Requirements Applies To Lighting Equipment.
line to group 4 KV.
Notes:
1. Normal input voltage range 100~277Vac.
2. Measured at input 220V with a full load.
3. All specifications are typical at 25 °C unless otherwise stated.
4. Constant current operation region is preferably 50%~100% rated output voltage. This is the suitable operation region for LED related applications, but
please reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static curve for more details.
6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by
the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again
http://www.hec-group.com.tw/
[email protected]
TEL:+886-6-356-0606
FAX:+886-6-356-0505
3
HEC-100RTA-48QSCA Rev A1.0
E. Dimming Control
The dimmer control is operated from an input signal (DC voltage / PWM signal / Variable Resistor). Please refer to the
diagram.
Notes:
1. If the dimming pin is not used, Dimming pin can be open.
Parameter
Min.
Typ.
Max.
1-10V Dimming Voltage (V)
1
-
+ 10.8
PWM Signal
5
10
+ 10.8
0~10K
-0
-
+10K
ΩVariable Resistor (Ω)
http://www.hec-group.com.tw/
[email protected]
TEL:+886-6-356-0606
FAX:+886-6-356-0505
Notes
4
HEC-100RTA-48QSCA Rev A1.0
- DC Voltage Dimming Curve
- PWM Signal Dimming Curve
- Variable Resistor Curve
http://www.hec-group.com.tw/
[email protected]
TEL:+886-6-356-0606
FAX:+886-6-356-0505
5
HEC-100RTA-48QSCA Rev A1.0
F. Electronic Curve
- Derating Curve
- Static Curve
- Power Factor Characteristics Curve
- Efficiency Characteristics Curve
http://www.hec-group.com.tw/
[email protected]
TEL:+886-6-356-0606
FAX:+886-6-356-0505
6
HEC-100RTA-48QSCA Rev A1.0
- Life Time vs. Case Temperature Curve
G. Mechanical Outline
http://www.hec-group.com.tw/
[email protected]
TEL:+886-6-356-0606
FAX:+886-6-356-0505
7
HEC-100RTA-48QSCA Rev A1.0
H. RoHS Compliance Outline
Our products comply with the European Directive 2011/65/EU, calling for the elimination of lead and other hazardous
substances from electronic products.
I. Revision History
Change Date
Description of Change
Rev.
Item
2014-12-08
A1.0
Revised Static Curve
http://www.hec-group.com.tw/
[email protected]
TEL:+886-6-356-0606
FAX:+886-6-356-0505
From
To
/
/
8