2362 SMD 2 FORM C REED RELAY

2362 SMD 2 FORM C REED RELAY
2362 Series SMD 2 Form C Reed Relay
The 2362 is the Surface Mount version of Coto Technology’s popular 2342
2 Form C Pico relay. The 2362 offers a proven reed design with longer life than
competing 2 Form C EMR products. The 2362 is the ideal solution for automated
test, instrumentation and telecommunication applications to increase system reliability and life.
2362 Series Features
u 2 Form C Contacts
u Hermetically Sealed Contacts
u Long Life / High Reliability
u Magnetically Shielding Steel Shell
u Surface Mount Relay
u RoHS compliant
DIMENSIONS
in Inches (Millimeters)
RECOMMENDED LAND PATTERN DIMENSIONS
PER IPC STANDARDS
.700 (17.8)
.500 (12.7)
.300 (7.6)
.100 (2.5)
.080 (2.0)
.110 (2.8)
.190 (4.8)
.030 (0.8) Max.
Ordering Information
Part Number 2362-XX-000
Coil Voltage
05=5 volts
12=12 volts
06222015
tel: (401) 943.2686
|
fax: (401) 942.0920
MODEL NUMBER
Parameters
COIL SPECS.
2362
Test Conditions
Nom. Coil Voltage
Units
2 Form C
VDC
5 12
+/- 10%, 25° C
Ω
175 1000
Operate Voltage
Must Operate by
VDC - Max.
3.8 9.0
Release Voltage
Must Release by
VDC - Min.
0.4 1.0
Switching Voltage
Max DC/Peak AC Resist.
Volts
100
Switching Current
Max DC/Peak AC Resist.
Amps
0.25
Carry Current
Max DC/Peak AC Resist.
Amps
0.5
Max DC/Peak AC Resist.
Watts
3
Coil Resistance
CONTACT RATINGS
Contact Rating
Signal Level 1.0V, 10mA
x 10 Ops.
250
Static Contact
Resistance (max. init.)
50mV, 10mA
Ω
0.200
Dynamic Contact
Resistance (max. init.)
0.5V, 50mA
at 100 Hz, 1.5 msec
Ω
0.250
Insulation Resistance
(minimum)
Between all Isolated Pins
at 100V, 25°C, 40% RH
Ω
109
Capacitance - Typical
Across Open Contacts
No Shield
Shield Guarding
pF
pF
2.0
N/A
Dielectric Strength
(minimum)
Between Contacts
Contacts to Shield
Contacts/Shield to Coil
VDC/peak AC VDC/peak
AC
VDC/peak AC
200
N/A
1000
Operate Time including bounce - Typical
At Nominal Coil Voltage,
30 Hz Square Wave
msec.
1.5
msec.
2.0
Life Expectancy-Typical
1
6
RELAY SPECIFICATIONS
Release Time - Typical
Top View:
Dot stamped on top of relay refers to pin #1 location
Grid = .1”x.1” (2.54mm x 2.54mm)
5
6
4
3
7
8
2
1
Notes:
1
Consult factory for life expectancy at other switching loads.
Environmental Ratings:
Storage Temp: -35°C to +100°C; Operating Temp: -20°C to +85°C
Max Relay Temp During Solder Reflow Process: 260°C for 1 minute maximum
All electrical parameters measured at 25°C unless otherwise specified.
Vibration: 20 G’s to 2000 Hz; Shock: 50 G’s
06222015
For most recent data visit www.cotorelay.com
COTO TECHNOLOGY, INC.