SMB Buccaneer Wiring_iss1
7/12/04
5:03 pm
Page 1
SMB Buccaneer Environmentally Sealed Connector
SPECIFICATION
Electrical (SMB connector):
Impedance:
Frequency Range:
Contact Resistance:
Centre:
Outer:
Insulator Resistance:
50Ω
0-4GHz
6mΩ (max.)
2.5mΩ (max.)
1000MΩ (max.)
Mechanical:
Sealing:
Cable Acceptance:
Insertion/Withdrawal Force:
Insertion Force:
Withdrawal Force:
Cable Retention Force:
Mating Cycles:
Operating Temperature:
IP68, EN 60529
RG-174
8 lbs (max.)
8 lbs (max.)
4 lbs (min.)
500
–40ºC to +80ºC
Material:
400 Series Bodies
Body Mouldings:
Body Mouldings:
Flammability Rating:
UV Resistance:
O Rings:
Chassis Sealing O Ring:
SMB Connector
Body:
Centre Contact:
Plug:
Jack:
Insulator:
Crimp Ferrules:
Polyamide (Flex)
PVC (Chassis)
UL94V-0
To EN 50021:1999
Nitrile
Nitrile
Brass to QQ-B-626, Gold Plated
Brass to QQ-B-626, Gold Plated
Beryllium Copper to QQ-B-530, Gold Plated
Teflon
Annealed Copper
SMB Buccaneer
IP68 Sealed Electrical Cable Connectors
Wiring and Assembly Instructions
for SMB Connector
Leaflet No: 14275 Iss No: 1
www.bulgin.co.uk
SMB Buccaneer Wiring_iss1
7/12/04
5:05 pm
Page 2
SMB Buccaneer Environmentally Sealed Connector
IMPORTANT - PLEASE READ INSTRUCTIONS PRIOR TO ASSEMBLY
Before using the connector, it is important that these instructions are carefully read and understood to ensure the connector system is
completely water tight and electrically safe.
IF IN DOUBT PLEASE CONSULT A QUALIFIED ELECTRICAN.
Body Moulding
The body moulding is snap fit assembly. This is a once only fit to completed after the connector has been wired. Do not snap
on before wiring is complete.
Cable Glands
The cable gland has been determined specifically to suit RG-174 cable. For other cable sizes please contact Bulgin Components.
Panel cut out details for
chassis mounting connector
ASSEMBLY/WIRING INSTRUCTIONS
Locking Ring
Gland
Carrier Housing
SMB Body
Centre
Contact
Crimp Ferrule
Positioner
Spacer
Clamp Nut
Body Moulding
1.
Thread the Clamp Nut, Spacer, Gland, Body Moulding, Positioner and Crimp Ferrule on to the cable. Also thread on the sealing cap retaining straps if using
sealing caps with the flex connectors.
Note: Check the locking ring is fitted over the Carrier Housing.
2.
Strip and prepare cable.
3.
Crimp centre contact using smallest cavity in crimp tool.
Slide SMB Body onto cable ensuring that the cable braid is laying over the crimp section of the barrel, than slide the Crimp Ferrule over braid and crimp using
larger cavity in crimp tool.
4.
Check internal O Ring is in place and correctly seated in the Body Moulding. Bring the Positioner and Body Moulding down the cable and snap firmly over the
Carrier Housing. If using the sealing cap ensure this is in place before fitting the Body Moulding.
5.
Bring the Gland and Spacer down the cable and locate in the Body Moulding. Finally screw the Clamp Nut onto the Body Moulding and tighten as close to the
shoulder as possible.